OF COMFORT
OUR HISTORY ................................................................. 4
WORLD WIDE LOCATIONS ................................................ 6
GLOBAL BUSINESS ACTIVITIES ......................................... 8
PROJECT REFERENCE ..................................................... 10
GLOBAL DEVELOPMENT & PRODUCTION BASES .............. 12
HIGH QUALITY DEVELOPMENT &
PRODUCTION FACILITIES ................................................ 14
AIRSTAGETM Solutions
OUR SOLUTION FOR ALL PROPERTIES ............................ 16
Light Commercial Solutions ......................................... 18
Commercial Solutions .................................................. 26
The AIRSTAGE series provides high energy savings, comfort, and reliability to the end user. The design, installation,
TM
and servicing were developed based on the concepts of high flexibility and simplicity. We offer an abundant VRF AIRSTAGETM CORE TECHNOLOGY
system lineup to match regional and customer needs by providing the best combination from low to high capacities HIGH ENERGY EFFICIENCY ............................................ 30
and from giving priority to conserving installation space to giving priority to high efficiency. MORE COMFORT ........................................................... 32
HIGH RELIABILITY ........................................................ 34
DESIGN FLEXIBILITY ..................................................... 36
EASY INSTALLATION ..................................................... 38
EASY SERVICE & MAINTENANCE .................................... 40
AIRSTAGETM SERIES
AIRSTAGETM LINE-UP ..................................................... 44
HEAT PUMP TYPE AIRSTGAETM J-IIIL ............................... 46
HEAT PUMP TYPE AIRSTGAETM J-III ................................ 52
HEAT PUMP TYPE AIRSTGAETM J-IIS ............................... 56
HEAT RICOVERY TYPE AIRSTAGETM VR-II ......................... 60
HEAT PUMP TYPE AIRSTAGETM V-III ............................... 68
For SMALL BUILDING For LARGE BUILDING HEAT PUMP TYPE AIRSTAGETM V-III TROPICAL series....... 74
14HP - 16HP
AIRSTAGETM CONTROL SYSTEMS
8HP - 12HP BEST CONTROL SOLUTION FOR EACH PROPERTY............ 116
CONTROL SYSTEM OVERVIEW ...................................... 118
Heat Pump type Heat Pump type Heat Pump type Heat Recovery Modular type Heat Pump Modular type Heat Pump Modular type
for heating or cooling operation for heating or cooling operation for heating or cooling operation for simultaneous heating and cooling operation for heating or cooling operation for heating or cooling operation COMPARISON TABLE OF CONTROLLERS ....................... 120
,QGLYLGXDO&RQWUROOHU
&HQWUDOL]HG&RQWUROOHU
Production by order &RQYHUWRU$GDSWRU
8 HP - 12 HP 3 Models 4 HP - 6 HP 6 Models 4 HP - 6 HP 3 Models 8 HP - 48 HP 34 Models 8 HP - 54 HP 39 Models 8 HP - 54 HP 39 Models
14 HP - 16 HP 2 Models 6LQJOHSKDVHSKDVH 6LQJOHSKDVH 6SDFHVDYLQJFRPELQDWLRQ+3WR+3PRGHOV 6SDFHVDYLQJFRPELQDWLRQ+3WR+3PRGHOV 6SDFHVDYLQJFRPELQDWLRQ+3WR+3PRGHOV VENTILATION
SKDVH (QHUJ\HIILFLHQF\FRPELQDWLRQ+3WR+3PRGHOV (QHUJ\HIILFLHQF\FRPELQDWLRQ+3WR+3PRGHOV (QHUJ\HIILFLHQF\FRPELQDWLRQ+3WR+3PRGHOV Energy Recovery Ventilator ......................................... 150
DX-Kit for air handling applications ............................ 152
SUPPORT
AIRSTAGE™ SUPPORT .................................................. 168
AIRSTAGE™ / RAC SUPPORT TOOL ................................ 170
QUICK SERVICE & MAINTENANCE ................................. 172
SERVICE TOOL ............................................................. 174
WEB MONITORING TOOL ............................................. 176
2 3
OUR MESSAGE
NEW
OUR HISTORY
Overseas Air Conditioning Business since 1971
VRF Business since 2001
J-IIIL series
High efficiency and compact design model
10HP to 16HP / Heat pump
FUJITSU GENERAL’s VRF AIRSTAGETM Series has been developed based on our long-term
air-conditioning technology know-how and was first provided 14 years ago.
P46
We have offered a series of products from large homes to large-scale buildings to meet the
various market needs.
14HP - 16HP
8HP - 12HP
For Commercial Use
VR-II series V-II TROPICAL series J-IIS series V-III series J-III series V-III TROPICAL series
High efficiency and Tropical spec model High efficiency and High efficiency and large High efficiency and Extensive lineup from
Compact design model Extensive lineup from 8HP compact design model capacity model. Extensive small capacity model 8HP to 54HP in 2HP increment /
V-II series J-II series 8 to 48HP / Heat Recovery to 42HP in 2HP increment / 4HP to 6HP / Heat pump lineup from 8HP to 54HP in 4HP to 6HP / Heat pump Heat pump
High efficiency and High efficiency and Heat pump 2HP increment / Heat pump
Compact design model small capacity model
Extensive lineup from 8HP to 48HP 4HP to 6HP / Heat pump
in 2HP increment / Heat pump P60 P56 P68 P52 P74
J series V series
6HP / Heat pump 8 to 42HP /
10HP / Heat recovery Heat pump
Established as 8,10HP / Heat pump
S series
Yaou Shouten Ltd. & Cooling
10HP / Heat recovery
Air conditioner & Heat pump
exports to
Middle East.
4 5
OUR MESSAGE
:25/':,'(/2&$7,216
Promoting Globalization from a global perspective while emphasizing the actual local situation in
the field under the aim of advancing our five-base system (Europe, Middle East, Asia & Oceania,
Americas, and Japan)
$LUFRQGLWLRQHUVROXWLRQFHQWHU
´7+($,567$*(µLQ0DQKDWWDQ1HZ<RUN
)XMLWVX*HQHUDO/LPLWHG
)XMLWVX*HQHUDO$PHULFD,QF )XMLWVX*HQHUDO2ULHQW,QWHUQDWLRQDO
(OHFWURQLFV6DOHV6KDQJKDL&R/WG
)XMLWVX*HQHUDO$XVW
3W\/LPLWHG
-$3$1+HDG2IILFH )XMLWVX*HQHUDO
1HZ=HDODQG
/LPLWHG
13
)XMLWVX*HQHUDO
$VLD3WH/WG
)XMLWVX*HQHUDO
Overseas Sales Companies 0LGGOH(DVW)=(
)XMLWVX*HQHUDO7DLZDQ&R/WG )XMLWVX*HQHUDO7KDLODQG&R/WG )XMLWVX*HQHUDO$VLD37(/WG )XMLWVX*HQHUDO$XVW3W\/WG )XMLWVX*HQHUDO1HZ=HDODQG/WG )XMLWVX*HQHUDO0LGGOH(DVW)=(
%DQJNRN2IILFH 6LQJDSRUH $XVWUDOLD 1HZ=HDODQG 8$(
)XMLWVX*HQHUDO2ULHQW
,QWHUQDWLRQDO(OHFWURQLFV6DOHV )8-,768*(1(5$/62/87,21
6KDQJKDL&R/WG&KLQD )XMLWVX*HQHUDO(852*PE+ )XMLWVX*HQHUDO8.&R/WG8. )XMLWVX*HQHUDO$LU&RQGLWLRQLQJ )XMLWVX*HQHUDO'R%UDVLO/WGD%UDVLO )XMLWVX*HQHUDO$PHULFD,QF &(17(5´7+($,567$*(µ
8./LPLWHG
6 7
OUR MESSAGE
*/2%$/%86,1(66$&7,9,7,(6
We are engaging in advertising, human resource development, CS activities, and social contribution
activities worldwide. These activities have been recognized throughout different regions by the
awards we have been honored with.
1RUWK6RXWK
$PHULFD 0LGGOH(DVW (XURSH 2FHDQLD $VLD
,QWHUQDWLRQDODXWKRULWDWLYHGHVLJQDZDUGV
7KHL)3URGXFW'HVLJQ$ZDUG 7KHSURGXFWGHVLJQ
&RROZRUOG,QGXVWU\
´'HDOHU'HVLJQ$ZDUGVµ LVJLYHQHDFK\HDUE\´L) FRPSHWLWLRQKDVH[LVWHGVLQFH &KLQD6WDWH&RQVWUXFWLRQ
$ZDUGV
RI´WKH1(:6µ ,QWHUQDWLRQDO)RUXP'HVLJQ ,WVDZDUGWKH´UHG (QJLQHHULQJ/XEDQ3UL]H
0RVW(IILFLHQW$LU
*PE+µIRULQGXVWULDOSURGXFWV GRWµLVDQLQWHUQDWLRQDOO\
&RQGLWLRQHU
IURPDURXQGWKHZRUOG UHFRJQL]HGTXDOLW\VHDO
*ROG$ZDUG&DWHJRU\
+9$& 3/80%,1*LQ
5HDGHU·V&KRLFH$ZDUGV
7KH*RRG'HVLJQ$ZDUGLV
&DQVWDU%OXH0RVW VSRQVRUHGE\WKH-DSDQ,QVWLWXWH
6DWLVILHG RI'HVLJQ3URPRWLRQDQGLV
7232)0,1'µ)LUVWSUL]H &XVWRPHUV$ZDUG DZDUGHGRQFHD\HDUIRUDQLWHP
LQ´0$5&$'((48,3$0(172'( RIH[FHOOHQWGHVLJQ
$5&21',&,21$'2µFDWHJRU\RI
´&/,0$7,=$&$2µGLYLVLRQ
8 9
OUR MESSAGE
352-(&75()(5(1&(
Our product is popular because of its high quality, energy saving, and easy installation, and so has
been installed in a wide range of building types including high-rise office buildings, stores, hotels,
public facilities, schools, hospitals and residential.
)XMLWVX*HQHUDO·V3URGXFWVKDYHEHHQLQVWDOOHGLQ
RYHUFRXQWULHVZRUOGZLGH
2 7
)RU&200(5&,$/
7 Office in Europe
8 Office in Europe
9
9 Hotel in Asia
10
5 12
)RU/,*+7&200(5&,$/
1 Shop in Asia
)RU5(6,'(17,$/
2 Restaurant in Middle East
3 Office in Europe 10 Residential in Europe
4 Hotel in Oceania 11 Residential in Europe
13
5 School in U.S.A. 12 Residential in Oceania
6 Hospital in Asia 12 Residential in Middle East
10 11
OUR MESSAGE
*/2%$/'(9(/230(17 352'8&7,21%$6(6
R&D centers are set up in five countries of Japan, Europe, Asia, China and North America in the
world. We pursue the environmental property and comfort to meet each area needs.
Overseas
0DQXIDFWXULQJ
Companies
)*/6(OHFWULF&R/WG
)*/6(OHFWULF&R/WG
)XMLWVX*HQHUDO/LPLWHG
5 '&HQWHU
)XMLWVX*HQHUDO$PHULFD,QF )XMLWVX*HQHUDO&HQWUDO$LUFRQGLWLRQHU
5 '&HQWHU :X[L&R/WG
5
5 '&HQWHU
)*$7KDLODQG&R/WG 7&)*&RPSUHVVRU7KDLODQG&R/WG
7&)*&RPSUHVVRU7KDLODQG&R/WG
5 '&HQWHU
-$3$1+HDG2IILFH
5 '&HQWHUDQGP+HLJKW'LIIHUHQFH
7HVWLQJ7RZHU
12 13
OUR MESSAGE
+,*+48$/,7<'(9(/230(17 352'8&7,21)$&,/,7,(6
Fujitsu General is one of Japan’s leading manufacturers with an R&D Center in Japan.
We provide customers with the highest quality and performance using these facilities.
,62
$&48,6,7,212),62 ,62
1XPEHURIFRPSDQLHV
Testing RI,62DQG,62LQGLYLGXDOO\
Middle East
Sales subsidiary (1)
Japan
+HDGRIILFH
,QRYHUVHDVVDOHVEDVHVFRPSDQLHV 0DQXIDFWXULQJVXEVLGLDU\
DFTXLUHGWKHFHUWLILFDWLRQRI,62
South America
$LU9ROXPH0HDVXUHPHQW5RRP &DORULPHWHU 6LOHQW5RRP Sales subsidiary (1)
Oceania
0HDVXUHDLUYROXPHVRIWKHDLU 0HDVXUHWKHFRROLQJKHDWLQJ 0HDVXUHWKHRSHUDWLQJVRXQGVRI 6DOHVVXEVLGLDU\
FRQGLWLRQHUVIURPFRPSDFW5$& FDSDFLW\E\PHDVXULQJWKH DLUFRQGLWLRQHUVZLWKWKHVRXQG
PRGHOVWR95) LQOHWDQGRXWOHWWHPSHUDWXUHV UHIOHFWLRQSURRIZDOOVDQGFHLOLQJ
KXPLGLW\DQGDLUYROXPHRIWKH
DLUFRQGLWLRQHU
4XDOLW\$VVXUDQFH %DODQFHULQVSHFWLRQ
5R+6LQVSHFWLRQ
3DUWVYLVXDOLQVSHFWLRQ
3DUWVVSHFLILFDWLRQV
&RQVWDQW7HPSHUDWXUH5RRP 3UDFWLFDO7HVW5RRP 6KRZHU7HVW5RRP LQVSHFWLRQ
7HVWLQJ/DERUDWRU\ P+HLJKW'LIIHUHQFH
LQVSHFWLRQ
6WULQJHQWTXDOLW\LQVSHFWLRQLVFDUULHGRXW
YLVXDOLQVSHFWLRQ
7HVWLQJ7RZHU
DWDOOSURGXFWLRQSURFHVVHV+LJKTXDOLW\ Packing
2EMHFWLYHLVWRFRQILUPRLOFLUFXODWLRQRI
)XMLWVX*HQHUDO(0&/DERUDWRU\/LPLWHG LVPDLQWDLQHGE\VWULQJHQWFKHFNVE\
FRPSUHVVRUIRUUHOLDELOLW\
LQVSHFWRUVDQGUHSHWLWLYHLQVSHFWLRQ
Completed product inspection
6DPSOLQJLQVSHFWLRQ
3HUIRUPDQFH 9LVXDOLQVSHFWLRQ
LQVSHFWLRQ :DWHULQMHFWLRQ
LQVSHFWLRQ
9LEUDWLRQGURSWHVW
14 15
AIRSTAGE™ Solutions
28562/87,21)25$//3523(57,(6
Fujitsu General provides the best solutions suitable for properties.
16 17
AIRSTAGE™ Solutions
60$//2)),&(6
Fujitsu General provides perfect total air conditioning systems that
take into account energy saving, low noise, comfortable airflow,
small room application and Centralized control for small-sized office
buildings with many small rooms.
1(W
&HQWUDOL]HGFRQWURORI 1HZGHVLJQSDQHOVLGHDOIRU
ERWKDLUFRQGLWLRQLQJ JULGFHLOLQJ
DQGYHQWLODWLRQ :HKDYHHTXLSSHGDQHZPPVTXDUHGHVLJQSDQHOWKDWLV
HTXLSPHQW LGHDOIRUWKHJULGFHLOLQJIRXQGLQPDQ\RIILFHVLQ(XURSH(DV\
LQVWDOODWLRQDQGILQLVKHGEHDXW\DUHHQKDQFHGE\WKHVHQHZ
,WLVSRVVLEOHWRSHUIRUPFHQWUDOL]HGFRQWURO SDQHOV
WRVWRSWKHRSHUDWLRQRIOLJKWLQJDQG
YHQWLODWLRQHTXLSPHQWLQDGGLWLRQWRDLU
FRQGLWLRQHUV7KLVLVXVHIXOLQHQHUJ\VDYLQJ
J-IIIL
J-III J-IIIL High capacity model
PDQDJHPHQWRYHUWKHZKROHEXLOGLQJ 1(W
PP
$,567$*(70 J-Series Compact Cassette
8SWR+3E\FRPSDFWRXWGRRUXQLW VRF Grid Type
indoor units
6PDOO95)V\VWHPLVVXLWDEOHIRUWKHEXLOGLQJVZLWKPDQ\VPDOOURRPV0D[
LQGRRUXQLWVFDQEHFRQQHFWHG
2QO\-,,,/+3PRGHO
Facilities
Lightning Ventilation Energy Recovery N:SHUVRQDODLU
Ventilator
J-IIIL
FRQGLWLRQLQJ Wall Mounted
(QHUJ\VDYLQJVROXWLRQVXLWDEOH &RPSDFWDQGORZQRLVHGHVLJQ 9DULRXVUDQJHRIORZFDSDFLW\N:
IRUPHHWLQJURRPVDQGEXVLQHVV RXWGRRUXQLW LQGRRUXQLWVWRVXLWVPDOOURRPVRU
GLVFXVVLRQURRPV VSDFHV
7KLVFRPSDFWRXWGRRUXQLWGRHVQ·WWDNHXS
:KHQWKHUHDUHQRSHRSOHLQWKHURRPVDYH PXFKVSDFHHYHQLILQVWDOOHGLQDPDFKLQH
RSHUDWLRQVWDUWVDXWRPDWLFDOO\WRSUHYHQW URRPRURQWKHURRIWRS7KLVXQLWVHFXUHV
XQQHFHVVDU\SRZHUFRQVXPSWLRQE\OLQNLQJ HQRXJKVWDWLFSUHVVXUHHYHQLIWKHUHDUH
XSZLWKDKXPDQVHQVRUDQGH[WHUQDOLQSXW ORXYHUV/RZQRLVHRSHUDWLRQLVSRVVLEOHDW
RXWSXWNLW QLJKWWLPHE\DORZQRLVHPRGH System Controller Lite Compact Floor
18 19
AIRSTAGE™ Solutions
Light Commercial
HOTELS
*XHVWURRPDLUFRQGLWLRQLQJ
ZLWKH[FHOOHQWFRPIRUWHQHUJ\
VDYLQJDQGHDV\LQVWDOODWLRQ
1(W
&DUGNH\VZLWFKDYDLODEOH &RPIRUWDEOHDLUIORZWKDW
8VLQJWKHFDUGNH\SUHYHQWV\RX VZLWFKHVXSDQGGRZQDLU
IURPIRUJHWWLQJWRVZLWFKRIIWKH GLUHFWLRQV
DLUFRQGLWLRQHU 7KH$XWR/RXYHU*ULOOH.LW
DFKLHYHVFRPIRUWDEOHDLUIORZE\
DGMXVWLQJWKHDLUGLUHFWLRQ
J-IIIL
High capacity model
J-III J-IIIL
$,567$*(70 J-Series
Use of an external Auto Louver Grille Kit
$SSHDUDQFH connect switch
RULHQWHGFRPSDFW
RXWGRRUXQLW
'XHWRWKHORZHVWDQGPRVWFRPSDFW
GHVLJQLQWKHLQGXVWU\WKHDSSHDUDQFH 9HQWLODWLRQRI
RIKRWHOLVQRWGDPDJHGHYHQZKHQ
LQVWDOOHGRQWKHEXLOGLQJ WKHZKROHKRWHO
VXSSRUWHG
2XWGRRUDLUSURFHVVLQJLVHVVHQWLDOLQ
KRWHOVSDFHVZLWKDKLJKGHJUHHRI
DLUWLJKWQHVV7KH';.LWFDQOLQNXSZLWK System controller
DLUFRQGLWLRQHUVWRHQVXUHVXIILFLHQW
/DUJHVSDFHDLU YHQWLODWLRQ
7KLVV\VWHPFDQEHH[SDQGHG
&HQWUDOL]HGFRQWURO
FRQGLWLRQLQJLQWKH RIDLUFRQGLWLRQLQJ
6LPSOH5HPRWH&RQWUROOHUZLWK
UHFHSWLRQDQGOREE\ LQVKDUHGVSDFHV
VRSKLVWLFDWHGGHVLJQ
8OWUDODUJHGXFWW\SHVLQJOHVSOLWV\VWHP $LUFRQGLWLRQLQJLQVKDUHGVSDFHVVXFK
VXLWDEOHIRUODUJHVSDFHVZLWKKLJK DVOREELHVDQGKDOOZD\VLVFRQWUROOHG 6XLWDEOHIRUKRWHOVRURIILFHVDVLWLVHDVLO\RSHUDWHGZLWKQRFRPSOH[
FHLOLQJV FHQWUDOO\7HPSHUDWXUHDQGRSHUDWLQJ IXQFWLRQV
FRQGLWLRQVFDQEHPDQDJHGZLWKRXWWKH /DUJH/&'VFUHHQ VLPSOHRSHUDWLRQEXWWRQV:KLWHFRORUHGEDFNOLJKW
((9XQLW &RQWUROXQLW DGMXVWPHQWE\JXHVWV RQPRQLWRUHQDEOHHDV\RSHUDWLRQLQGDUN
20 21
AIRSTAGE™ Solutions
Light Commercial
SCHOOL
Fujitsu General provides the optimal number of connected indoor units
for mid-sized educational institutions. The degree of freedom of the
installation location selection is improved with a compact design that
minimizes the installation area. Even one outdoor unit can cover the
entire school building.
&RPIRUWDEOHURRPDLUFRQGLWLRQLQJZLWKRXW
DLUIORZIHHOLQJ
&LUFXODU$LUIORZ&DVVHWWH
EORZVRXWLQDOOGLUHFWLRQV
ZLWKRXWWHPSHUDWXUH
XQHYHQQHVV
Mini Duct
/$1
PC ,QGLYLGXDODLUIORZGLUHFWLRQFRQWUROWRSUHYHQWSHRSOHIURP
EHLQJH[SRVHGWRDLUIORZ
Touch Panel Controller UTY-DTGYZ1
Wireless )L[HG,3,3IRUZDUGLQJ
DQGRSHQ3RUWUHTXLUHG
/$1
INTERNET
1HZFHQWUDOL]HGUHPRWH Router Tablet PC Energy Recovery Ventilator
FRQWUROOHUZLWKLPSURYHG Smartphone
L26$QGURLGDQGRU:LQGRZV
RSHUDELOLW\ &RQWURODQG
(QHUJ\VDYLQJRSHUDWLRQZKHQWKHUH
DUHQRSHRSOHE\OLQNLQJXSZLWK
KXPDQVHQVRU
7HPSHUDWXUHPDQDJHPHQWRIHDFKFODVVURRPDQGRQH PRQLWRULQJ
ZHHNRSHUDWLRQFRQWUROPDQDJHPHQWVHWWLQJVDUH
VXSSRUWHGHDVLO\7KLVFRQWUROOHUPDNHVHQHUJ\VDYLQJ
9DULRXVLQGRRUXQLWV
7KHVDPHPDQDJHPHQWDVZLWKWKH
PDQDJHPHQWSRVVLEOHZLWKXSSHUORZHUWHPSHUDWXUH PDLQXQLWLVSRVVLEOHHYHQLI\RXDUHDW :HKDYHDOLQHXSRILQGRRUXQLWVWKDWFDQDOVRVXSSRUW 3.2 m
OLPLWVHWWLQJVDQGRSHUDWLRQSURKLELWHGVHWWLQJV \RXUGHVN1RQDGPLQLVWUDWRUVFDQDOVR FRPSOH[DSSOLFDWLRQV²IURPQRUPDOFODVVURRPVWRVSHFLDO
RSHUDWHWKHDLUFRQGLWLRQHUVZLWKD3& FODVVURRPVDQGDXGLWRULXPV$LUFRQGLWLRQHUVFDQEHDOVR 8.8 m Human sensor
DGGHGHDVLO\ (Option)
6PDUWSKRQHRUWDEOHW
22 23
AIRSTAGE™ Solutions
Light Commercial
5(67$85$176+236
Fujitsu General provides perfect total air conditioning systems that offer smooth
support by tenant, by purpose and by customer visit frequency in shops and
restaurants with multiple lighting and a high density of customers.
RESTAURANT
SHOPS
$SSURSULDWHDLU
FRQGLWLRQLQJLQWKH /RZRXWVLGHDLUWHPSHUDWXUH
DWULXPVSDFH FRROLQJDLUFRQGLWLRQLQJVXSSRUW
Cassette Circular Flow Series
$SSURSULDWHDLUFRQGLWLRQLQJRIWKHKLJK /RZRXWVLGHDLUWHPSHUDWXUHFRROLQJRSHUDWLRQLVQHFHVVDU\LQZLQWHU
For bright Interior rooms etc.
FHLOLQJDQGJODVVVLGHGDWULXPVSDFH LQVWRUHVZLWKDORWRIKHDWLQVLGH$LUFRQGLWLRQLQJV\VWHPFDQEH
ZLWKDODUJHGXFWV\VWHP VXSSRUWHGIOH[LELOLW\WRDOORZFRROLQJRSHUDWLRQDW&
&RORUYDULDWLRQVE\
High Static Pressure Duct WZRSDQHOV
%RWKEODFNDQGZKLWHSDQHOVDUH
DYDLODEOHIRU&DVVHWWHW\SH%ODFNSDQHO
Medium Static Pressure Duct
LVVXLWDEOHIRUWKHGDUNSODFHVXFKDV
30-150 Pa
DUHVWDXUDQWZLWKDWPRVSKHUH:KLWH
SDQHOLVXVXDOO\XVHGDWEULJKWDUHDV
VXFKDVRIILFHV$YDLODEOHWRVLQJOHVSOLW
DQG95)LQGRRUXQLWV
24 25
AIRSTAGE™ Solutions
Commercial
/$5*(%8,/',1* &HQWUDOL]HGFRQWURO
1RWRQO\LQGRRUXQLWVLQWKHEXLOGLQJEXWDOVRIDFLOLWLHVVXFKDV
YHQWLODWLRQFDQEHFRQWUROOHGHDVLO\E\DQ\RQH
Fujitsu General provides modular type VRF systems that seek high 6\VWHP&RQWUROOHU
efficiency, comfort, design freedom, easy installation and reliability 87<$3*;=
5HPRWH
VRF 0RQLWRULQJVLGH
indoor units
INTERNET
Facilities
Lightning Ventilation Energy Recovery
Ventilator
Router
Smartphone
$EXQGDQWOLQHXSVXLWDEOH /LQNXSZLWKDYDULHW\RI%06
WRPDWFKWKHRSHUDWLQJ
&HQWUDOL]HGFRQWUROLQFOXGLQJIDFLOLWLHVDQGHTXLSPHQWLQ
HQYLURQPHQW DGGLWLRQWRDLUFRQGLWLRQLQJLVSRVVLEOHE\OLQNLQJXSZLWK
02'%86%$&QHW.1;DQGRWKHUYDULRXVLQWHUIDFHV
95)VHULHVOLQHXSWRPHHWYDULRXVQHHGVVXFKDVHQHUJ\VDYLQJ
RULHQWDWHGPRGHOVDQGPRGHOVFRPSDWLEOHZLWKDKLJKRXWGRRU
DLUWHPSHUDWXUHRI&
,QGLYLGXDODLUFRQGLWLRQLQJV\VWHPIRU
ODUJHEXLOGLQJV
&DSDFLWLHVFDQEHH[SDQGHGXSWR
VLPXOWDQHRXVFRROLQJDQGKHDWLQJZLWK
PD[LPXP+3/DUJHLQGLYLGXDODLU
FRQGLWLRQLQJLVVXSSRUWHG
Installation
Example
+LJKV\VWHP 5DSLGVHUYLFHVXSSRUW
IOH[LELOLW\ 7KHDLUFRQGLWLRQLQJRIWKHHQWLUHEXLOGLQJFDQEHPRQLWRUHG
)OH[LEOHLQVWDOODWLRQRQHDFKIORRUDQG UHPRWHO\ZLWK:HE0RQLWRULQJ7RRODQG6\VWHP&RQWUROOHU
LQVWDOODWLRQRIGLYHUVHLQGRRUXQLWVDUH 5DSLGUHVSRQVHIRUHPHUJHQF\LVSRVVLEOHE\DVHOIGLDJQRVLVLQ
SRVVLEOHWKURXJKWKHLQGXVWU\·VWRSFODVV DGYDQFHLQFRRSHUDWLRQZLWKDPDQDJHPHQWFRPSDQ\
KLJKVWDWLFSUHVVXUHORQJSLSLQJGHVLJQ
DQGFRQQHFWLRQFDSDFLW\
Remote Monitoring
6PDUWDQGFXWWLQJHGJHGHVLJQ([WHQVLYHOLQHXSIURP+3WR Internet Web
or Monitoring
+3LQ+3LQFUHPHQW&RQQHFWDEOHLQGRRUXQLWFDSDFLW\UDWLR Public Telephone Tool
Line
XSWR
+3+30RGHOV +3+30RGHOV
3D
3DIRU95,,
UTY-AMGXZ1
Software
6SDFHVDYLQJFRPELQDWLRQ+3WR+3PRGHOV 6SDFHVDYLQJFRPELQDWLRQ+3WR+3PRGHOV
(QHUJ\HIILFLHQF\FRPELQDWLRQ+3WR+3PRGHOV (QHUJ\HIILFLHQF\FRPELQDWLRQ+3WR+3PRGHOV
26 27
AIRSTAGETM VRF SYSTEMS CAN BE DESIGNED TO
CREATE AN AIR CONDITIONING SOLUTION TO
SUIT MOST BUILDINGS REQUIREMENTS.
AIRSTAGE
TM
HIGH ENERGY EFFICIENCY
CORE TECHNOLOGY
MORE COMFORT
HIGH RELIABILITY
DESIGN FLEXIBILITY
EASY INSTALLATION
EASY SERVICE & MAINTENANCE
28 29
AIRSTAGE CORE TECHNOLOGY
TM
limitation 28
26
The minimum and maximum temperature ranges can
be limited, which provide further energy saving while 24
Auto-off timer
New wired remote controller is equipped with an OFF timer
function that automatically stops operation when a fixed time
has elapsed from the start of operation. This prevents waste of
energy.
Furthermore a new wired remote controller can set up the
interval of time in case operation stops. Set interval time hour (17:00 to 24:00)
ON Auto OFF
31%UP!
7%UP! 35%UP!
(Screen image is Energy manager software(Option))
8%UP!
5 4.84
4.23 4.31 4.3
4 3.71 3.95
3.7
3.94 3.71
3.45 Capacity save operation Capacity
3.2 3.1
Setting
range
Capacity save
3 Operation capacity can be set in 5 steps for rated capability.
The power consumption at peak is cut down and the maximum
100% Setting
2 load is suppressed. level
80%
1 60%
40%
0
0%
J-II J-III J-II J-III V V-III V V-III S VR-II S VR-II
series series series series series series series series series series series series Time
30 31
AIRSTAGE CORE TECHNOLOGY
TM
MORE COMFORT
High
Precision refrigerant flow control
Hot
Hot ± 0.5°C
Precise and smooth refrigerant flow control is achieved by using Set temp.
a DC Inverter control in conjunction with individual indoor unit
electronic expansion valve control. This allows high precision C ld
Co
comfortable temperature control of ±0.5°C.
Low
Thermal change of the room
*Simulation in heating operation.
Comfortable operation is
Reach the set achieved due to a small variation of
temperature quickly room temperature
Quiet operation
Low noise mode
Two low noise modes can be selected automatically by quiet priority setting and capacity priority
setting depending on the indoor environment and outside temperature load. This feature can be
controlled via outdoor unit external input and/or system controller.
Quiet priority setting Capacity priority setting
Air Air
conditioning conditioning
load factor Heat load load factor Heat load
32 33
HIGH RELIABILITY
Backup operation
If one compressor fails, backup operation will be performed by
the remaining compressors*.
*: Note: Backup operation may not be possible depending on the trouble state.
Outdoor unit rotational operation ensure no liquid refrigerant is being fed into the compressor.
Large sized
Accumulator
The compressor starting order is rotated so that the running time is shared.
Rotation
Liquid refrigerant
(stays inside of
accumulator)
DC DC DC DC DC DC
DC
1 2 3 1 2 3
Corrosion resistant of the heat exchanger has been improved Cobalt Blue protection
by the introduction of blue fin treatment to the outdoor unit’s Standard chromate protection
heat exchanger.
Aluminium base material
Rotation Rotation
DC DC DC Hydrophilic coating
1 2 3
Note: Rotational operation is alternated by the start / stop timing of the compressor.
34 35
AIRSTAGE CORE TECHNOLOGY TM
DESIGN FLEXIBILITY
Overall piping length 1,000m Total pipe length
High capacity connection
1,000m max. AIRSTAGETM VR-II series AIRSTAGETM V-III series AIRSTAGETM V-III tropical series
Heat Recovery type Heat Pump type Heat Pump type
8HP-48HP 8HP-54HP 8HP-54HP
Connectable indoor unit Connectable indoor unit Connectable indoor unit
capacity range capacity range capacity range
Actual pipe length
50% to 150%*1 50% to 150%*3 50% to 130%
165m Height difference
(VR-II, V-III, V-III tropical) between outdoor and Connectable indoor Connectable indoor Connectable indoor
indoor units unit number unit number unit number
50m max. up to 64 up to 64 up to 64
For the outdoor unit installed below
the indoor units: 40m max.
AIRSTAGETM J-IIIL series AIRSTAGETM J-IIIL series
Heat Pump type Heat Pump type
14HP-16HP 8HP-12HP
Connectable indoor unit Connectable indoor unit
capacity range capacity range
Pipe length from first
*1. Conditions of maximum connectable indoor unit
separation tube to the Height difference
between indoor and
50% to 150%*1 50% to 150% capacity ratio is as the chart below.
farthest indoor unit
indoor units *2. Only 4HP is 46%
60m max. 15m max.
Connectable indoor
unit number
Connectable indoor
unit number
*3. Max. capacities in the combinations including the
(VR-II) 18HP outdoor unit fall below 150%.
up to 40 up to 30 Maximum connectable
90m* max. Series
indoor unit capacity ratio
(V-III, V-III tropical) Without 1.1kW With 1.1kW
models models*4
AIRSTAGE J-III series
TM AIRSTAGE J-IIS series
TM
AIRSTAGETM VR-II series AIRSTAGETM V-III series AIRSTAGETM V-III tropical series
Heat Recovery type Heat Pump type Heat Pump type
(°C) (°C) (°C)
Cooling
60 Cooling 60 Cooling 60
52°C
50 46°C 50 46°C 50
40
Cooling & 40 40
Heating Heating Heating Heating
30 30 30
21°C 21°C 21°C 21°C *5. Note : When a multiple outdoor unit
20 20 20
10 10 10
connection is used, operating range is
0 0 0
from -5°C to 46°C in cooling.
-10 -10 -10 *6. Note : Only when all indoor units are
Large diameter fan and DC motor has been utilized allowing an external static -20 -10°C -10°C -20 -15°C* 5 -20 -15°C* 6 5.6 kW or more in the system, the
pressure of 80Pa to 82Pa. This is approximately 2.6 times greater than the previous model. -20°C -20°C -20°C operation range is -15 to 46ºC.
36 37
AIRSTAGE CORE TECHNOLOGY
TM
EASY INSTALLATION
Easily transported Simple wiring work
Easily craned using lifting belt hooks Installation of the wiring systems is made easier as the
communication wiring can be installed continuously between
Design of outdoor unit allows for lifting
the indoor, outdoor and RB units.
straps to be used
or
Transporting by forklift
Transport with forklift is possible.
Easy evacuation - using vacuum Air Air
mode function
The vacuum mode function enables all expansion valves of
indoor units to be fully opened, making it easy to evacuate all
the air inside pipe lines and indoor units.
Air
Outdoor unit Vacuum pump
Can be transported in
a small elevator Automatic address setting
The address of the indoor unit, RB unit and signal amplifier can be set through the automatic function setting on the outdoor unit PCB.
1 Signal Amplifier
RB unit 3 7 1 0
Flexible installation by
4 way pipe direction
(J-IIIL is 3 way pipe direction.)
38 39
AIRSTAGE CORE TECHNOLOGY
TM
Service Tool
UTY-ASGXZ1
Outdoor unit Software
Transmission line
USB adaptor
(Locally purchased)
7-segment LED
Web
Monitoring Tool
Error code
Unit number
Error and
quantity Indoor unit
Wired Remote Controller annunciation
(Touch panel)
Error status / Error history
Error code
Abnormal indoor
unit address
40 41
The AIRSTAGE 6 Series has a total of 126 models
to meet the environmental and
building size requirements.
The AIRSTAGE series outdoor units were developed with structural designs and
AIRSTAGE
TM
AIRSTAGE™ LINE-UP
SERIES
HEAT PUMP TYPE AIRSTAGE J-IIIL
HEAT PUMP TYPE AIRSTAGE J-III
HEAT PUMP TYPE AIRSTAGE J-IIS
HEAT RECOVERY TYPE AIRSTAGE VR-II
HEAT PUMP TYPE AIRSTAGE V-III
HEAT PUMP TYPE AIRSTAGE V-III TROPICAL Series
42 43
AIRSTAGE Series TM
AIRSTAGE™ LINE-UP
Fujitsu General provides multi air conditioning systems for buildings AIRSTAGE Series
matched to the size and application of the property.
kW class 12.1 14.0 15.5 22.4 28.0 33.5 40.0 45.0 50.4 55.9 61.5 67.0 73.5 78.5 85.0 90.0 95.0 100.5 107.0 112.0 118.5 123.5 130.0 135.0 139.0 143.0 147.0
Space
saving
Heat Pump
AJY072LELAH AJY090LELAH AJY108LELAH AJY126LELAH AJY144LELAH
High
Efficiency
(Single phase)
AJY040LBLAH AJY045LBLAH AJY054LBLAH
Heat Pump
High
Efficiency
(3 phase)
AJY040LELAH AJY045LELAH AJY050LELAH
Space
Heat Pump saving
AJY040LCLAH AJY045LCLAH AJY054LCLAH
Space
saving
AJYA72GALH AJYA90GALH AJY108GALH AJY126GALH AJY144GALH AJY162GALH AJY180GALH AJY198GALH AJY216GALH AJY234GALH AJY252GALH AJY270GALH AJY288GALH AJY306GALH AJY324GALH AJY342GALH AJY360GALH AJY378GALH AJY396GALH AJY414GALH AJY432GALH
Heat Recovery
High
Efficiency
AJY144GALHH AJY198GALHH AJY216GALHH AJY234GALHH AJY252GALHH AJY270GALHH AJY288GALHH AJY306GALHH AJY324GALHH AJY342GALHH AJY360GALHH AJY378GALHH AJY396GALHH
Space
saving
AJY072LALBH AJY090LALBH AJY108LALBH AJY126LALBH AJY144LALBH AJY162LALBH AJY180LALBH AJY198LALBH AJY216LALBH AJY234LALBH AJY252LALBH AJY270LALBH AJY288LALBH AJY306LALBH AJY324LALBH AJY342LALBH AJY360LALBH AJY378LALBH AJY396LALBH AJY414LALBH AJY432LALBH AJY450LALBH AJY468LALBH AJY486LALBH
Heat Pump
High
Efficiency
AJY144LALBHH AJY162LALBHH AJY180LALBHH AJY216LALBHH AJY234LALBHH AJY252LALBHH AJY270LALBHH AJY288LALBHH AJY306LALBHH AJY324LALBHH AJY342LALBHH AJY360LALBHH AJY378LALBHH AJY396LALBHH AJY414LALBHH
Space
saving
AJY072LNLBH AJY090LNLBH AJY108LNLBH AJY126LNLBH AJY144LNLBH AJY162LNLBH AJY180LNLBH AJY198LNLBH AJY216LNLBH AJY234LNLBH AJY252LNLBH AJY270LNLBH AJY288LNLBH AJY306LNLBH AJY324LNLBH AJY342LNLBH AJY360LNLBH AJY378LNLBH AJY396LNLBH AJY414LNLBH AJY432LNLBH AJY450LNLBH AJY468LNLBH AJY486LNLBH
Heat Pump
High
Efficiency
AJY144LNLBHH AJY162LNLBHH AJY180LNLBHH AJY216LNLBHH AJY234LNLBHH AJY252LNLBHH AJY270LNLBHH AJY288LNLBHH AJY306LNLBHH AJY324LNLBHH AJY342LNLBHH AJY360LNLBHH AJY378LNLBHH AJY396LNLBHH AJY414LNLBHH
44 45
Features
System Outline
Compact Outdoor unit
The compact and low sound level enable the units to be
installed to various environment with restriction and/or 8HP 10HP 12HP 14HP 16HP
limited spaces such as mechanical rooms and or rooftops.
Quiet design
Top class low sound operation has been achieved. This Advanced high efficiency technology
allows installation of the units to various places without a
special sound prevention work.
570mm
Large propeller
ll ffan DC inverter control
The high efficiency and the low sound Efficiency is improved by mounting of new
operation are mutually realized by active filter module.
reduction of a draft loss which are enabled
by the Fujitsu General's original blade
design and a large diameter propeller fan.
Small Office System configuration example
• This system is used for small and medium-sized buildings. 1
refrigerant system is used for each outdoor unit.
• Connection of multiple indoor units using separation tubes and
headers.
Subcool heat exchanger
Cooling performance is improved by
DC fan motor mounting of dual tube heat exchanger.
Miniaturized, low noise, high efficiency,
Pressure
Outdoor unit
Outd multi-stage DC fan motor is mounted.
effect
Enthalpy
Indoor unit
Liquid pipe Scroll compressor
Scro
Gas pipe The e
equipment of scroll compressor with a
Large heat exchanger wide range of rotational frequency from 15
Heat exchange performance is substantially 15-120
20 rps to 120
12 rps together with Fujitsu General's
unique sensorless sine wave control method
uniqu
improved by mounting of 2.6-row large
heat exchanger. which smoothly control the input power run
Indoor unit into the
t motor realized a mutual
impro
improvement on the energy efficient
opera
operation and the low sound operation.
46 47
Features
Height difference
Compact Design
-262 mm
Compared with current 8 HP model
NEW
8/10/12 HP model
14/16 HP model
1,690 mm
1,428 mm
765 mm
Current model
AIRSTAGETM V-Series
outdoor unit
14/16 HP model
480 mm Current model
AIRSTAGETM V-Series
outdoor unit
8/10 HP model
Depth difference Space area Space area
-285 mm
J-IIIL all models
-45% !
Compared with
-26% !
Compared with
Compared with current all models current 14/16 HP model current 8/10 HP model
Inhouse installation
Space saving
Due to compact and thin model, direct ground installation or wall mounted installation is
possible even at narrow off-street.
48 49
Features
90m max. 50m* max. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
* The cooling operation range of -15 to 46°C is allowed only when all of the indoor units connected to the system are higher than capacity of 5.6kW.
(515.5)
40.5
(515.5)
40.5
Top view
1638
to densely populated areas thanks to their low operating
1428
sound.
1102
1017
66 dB(A)
B(A) 77dB(A)
23.5
-1
11dB(A)
447
479
Current model (8HP) Bottom view Bottom view
50 51
Features
5.01
Fujitsu General provides air conditioning systems 4.70
4.86 7 % UP
for a wide range of applications 4.33 4.41 4.51 8 % UP
4.17 4.23 4.23
4.05 3.92 3.95
from small office buildings and stores to large houses. 3.88
3.71 3.71
3.45
System Outline
High Energy Efficiency
Heat pump inverter control is used to achieve an efficient 4HP 5HP 6HP 4HP 5HP 6HP J-II J-III J-II J-III
cooling and heating operation in any indoor unit
combination.
DC fan motor
Miniaturized, low noise, high efficiency,
multi-stage DC fan motor is mounted.
Pressure
effect
Large heat exchanger
Outdoor unit
Heat exchange performance is substantially
improved by mounting of 3-row large heat
Separation tube Header
exchanger.
Compressor
efficiency
Highly accurate parts
DC Twin Rotary compressor
Indoor unit
52 53
Long piping capability Specifications
Total pipe length
Our advanced refrigerant control technology allows us
180m max.
Rating Capacity range HP 4 5 6 4 5 6
to achieve a total refrigerant piping length of 180m. This Model name AJY040LBLAH AJY045LBLAH AJY054LBLAH AJY040LELAH AJY045LELAH AJY054LELAH
opens up new possibilities in system design. Maximum Connectable Indoor Unit 1-9 1-10 1-13 1-9 1-10 1-13
43(Liquid)
51(Gas)
A comfortable room condition is maintained during oil recovery Previous model
(410)
J-III series (Heating operation)
370
mode because the product continues to operate without
40
stopping the cooling or heating operation.
32
36
970 32 370 12
ON ON
OFF
Time Time
Terminal blocks (Power)
1334
Easier Installation
1000
907
3-Way valve (Liquid)
111
wiring connection and address setting are correct by a
70
le port)
(Liquid valve)
(Gas valve)
ab
Ø28 (C
quick check run function.
297
279
120
21
25
95
155
142
131
87
Ø28 (Cable port) Ø28 (Cable port)
50
50
50
Ø28 (Cable port) 89 Pipe port 21 55 Ø28 (Cable port) 21 65 Ø28 (Cable port)
Pipe port Pipe port
A
Detail A
65 15
227
305
14
341
50
• Display connected indoor unit numbers
50
• Duplicately set address number of indoor unit can be 438 Pipe & cable port
displayed 622
54 55
Features
Height difference
998 mm
Ÿ25%
System Outline Low sound level design
Significantly low sound level is improved by using
Light weight
Space saving and low sound level design DC twin rotary compressor, inverter technology, and
Economical individual air conditioning is realized by ALL-DC 87 kg advanced airflow structure design.
technology, large capacity DC twin rotary compressor, and
Cooling 56
3-row heat exchanger though the size is compact.
dB(A)
54
53
Flexible systems for homes, shops,
small-size buildingss air conditioning 51
Due to compact size design and flexible piping design,
J-IIS series can be installed easily at the place where the 4 HP 5 HP 6 HP 6 HP
installation space is limited such as homes, shops, and small
Previous model
offices. Multiple indoor units of various capacities and types
can be connected.
Advanced high efficiency technology
Outdoor unit
High efficiency
compressor motor
Separation tube Header DC fan motor
Miniaturized, low noise, high Optimized refrigerant
efficiency, multi-stage DC fan flow design
motor is mounted.
Highly accurate
parts
Indoor unit
Compact and
Liquid pipe high performance
Smooth airflow grille
Gas pipe
This grille was aerodynamically designed for
DC twin rotary compressor
good efficiency with little blow loss. Efficiency in all load regions is good.
Especially good performance from low
to medium at normal operation.
Indoor unit Large heat exchanger
Heat exchange performance is High
substantially improved by
mounting of 3-row large heat
Compressor
efficiency
exchanger.
56 57
Features
Piping length from first Note : Specifications are based on the following conditions.
separation tube to the Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
farthest indoor unit Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
40m max. Height difference between The protective function may work when using it outside the operation range.
indoor and indoor units
ON ON
OFF
Time Time
Easier Installation
Connection check function : Possible to confirm whether Front view
wiring connection and address setting are correct by a Rear view
quick check run function. Side view
Bottom view
• Display connected indoor unit numbers
• Duplicately set address number of indoor unit can be
displayed Detail A
58 59
Features
(COP) 5
4.39 4.30 4.34 4.30
4.13 4.07 4.05 4.01 4.01 4.00 4.00
3.90 3.92 3.90 3.91 3.92 3.90 3.91 3.91 3.98 3.92
4
Space saving
Smart and cutting edge design
combination 3
Extensive lineup from 8HP to 48HP in 2HP increment
Connectable indoor unit capacity ratio up to 150%
2
8 10 12 14 16 18 20 22 24* 26 28 30 32 34 36 38 40 42 44 46 48 (HP)
System Outline 4
4.39
4.22
4.39 4.35 4.32 4.30
4.24 4.23 4.18 4.17
4.08 4.13 4.05
Space saving Energy efficiency
Energy efficiency
Simultaneous cooling and heating operation combination 3
using 1 refrigerant system
Cooling and heating can be freely selected for each indoor COP 12.6% UP
2
unit to provide simultaneous cooling and heating in rooms 16 22 24* 26 28 30 32 34 36 38 40 42 44 (HP)
with large temperature differences.
60 61
Features
RB Unit RB Unit
(Single type) (Multi type)
Capacity
speed control Max.3 or 8
Max. 8 indoor unit
indoor units
Comfortable space with 0.1Hz
small room temperature
changes and little energy Single Group Single
&
Group RB Unit less
loss is created by 0.1Hz connection connection connection connection connection*2
• The RB unit can be freely positioned between the first branch and the indoor unit.
• The maximum height difference between RB units is 15 m.
* 2. RB Unit is not necessary for cooling only use.
Inverter frequency
Small intake
airflow Heat •Up to 2 units can be
EEV exchanger
Distributor connected in series. RB unit Ceiling
Heat exchanger
Outdoor unit
62 63
Outdoor units lineup
• Combinations other than the followings are not recommended.
80 530
(Bolt pitch) 8-12 × 17 (Hole)
765 930
78.5kW (28HP) 85.0kW (30HP) 90.0kW (32HP) 95.0kW (34HP) 100.5kW (36HP)
1690
1576
1339
AJY252GALH AJY270GALH AJY288GALH AJY306GALH AJY324GALH
UNIT : AJY144/108GALH UNIT : AJY144/126GALH UNIT :AJY144/144GALH UNIT : AJY108/108/A90GALH UNIT : AJY108/108/108GALH
106.5kW (38HP) 112.0kW (40HP) 118.0kW (42HP) 123.5kW (44HP) 130.0kW (46HP)
B A C
765 1240
44.8kW (16HP) 62.4kW (22HP) 67.2kW (24HP) 72.8kW (26HP) 78.4kW (28HP)
1690
AJY144GALHH AJY198GALHH AJY216GALHH AJY234LALHH AJY252GALHH
UNIT : AJYA72/A72GALH UNIT : AJY126/A72GALH UNIT : AJYA72/A72/A72GALH UNIT : AJYA90/A72/A72LALH UNIT : AJYA90/A90/A72GALH
84.0kW (30HP) 90.4kW (32HP) 96.0kW (34HP) 102.4kW (36HP) 108.0kW (38HP)
B A C
80
Power supply
cable port Ø 43.7
Ø 22.2 Power supply cable port
Transmission cable port
82
Ø 22.2
95
Ø 22.2
75
64 65
Outdoor units specifications
Model name AJYA72GALH AJYA90GALH AJY108GALH AJY126GALH AJY144GALH AJY162GALH AJY180GALH AJY198GALH AJY216GALH AJY234GALH AJY252GALH AJY270GALH AJY288GALH AJY306GALH AJY324GALH AJY342GALH AJY360GALH AJY378GALH AJY396GALH AJY414GALH AJY432GALH
Unit 1 AJYA72GALH AJYA90GALH AJY108GALH AJY126GALH AJY144GALH AJYA90GALH AJYA90GALH AJY108GALH AJY108GALH AJY144GALH AJY144GALH AJY144GALH AJY144GALH AJY108GALH AJY108GALH AJY144GALH AJY144GALH AJY144GALH AJY144GALH AJY144GALH AJY144GALH
Unit 2 AJYA72GALH AJYA90GALH AJYA90GALH AJY108GALH AJYA90GALH AJY108GALH AJY126GALH AJY144GALH AJY108GALH AJY108GALH AJY108GALH AJY108GALH AJY144GALH AJY144GALH AJY144GALH AJY144GALH
Unit 3 AJYA90GALH AJY108GALH AJYA90GALH AJY108GALH AJYA90GALH AJY108GALH AJY126GALH AJY144GALH
Maximum Connectable Indoor Unit*1 15 16 17 21 24 32 30 32 35 39 42 45 48 50 53 57 60 63 64 64 64
Indoor unit connectable capacity Cooling kW 11.2-33.6 14.0-42.0 16.8-50.2 20.0-60.0 22.5-67.5 25.2-75.6 28.0-84.0 30.8-92.2 33.5-100.5 36.5-109.5 39.3-117.7 42.5-127.5 45.0-135.0 47.5-142.5 50.3-150.7 53.3-159.7 56.0-168.0 59.0-177.0 61.8-185.2 65.0-195.0 67.5-202.5
Power source 3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
Cooling 22.4 28.0 33.5 40.0 45.0 50.4 56.0 61.5 67.0 73.0 78.5 85.0 90.0 95.0 100.5 106.5 112.0 118.0 123.5 130.0 135.0
Capacity kW
Heating 25.0 31.5 37.5 45.0 50.0 56.5 63.0 69.0 75.0 81.5 87.5 95.0 100.0 106.5 112.5 119.0 125.0 131.5 137.5 145.0 150.0
Cooling 5.45 7.11 9.75 11.34 13.61 12.56 14.22 16.86 19.50 20.72 23.36 24.95 27.22 26.61 29.25 30.47 33.11 34.33 36.97 38.56 40.83
Input power kW
Heating 5.70 7.33 9.62 10.90 12.77 13.03 14.66 16.95 19.24 20.10 22.39 23.67 25.54 26.57 28.86 29.72 32.01 32.87 35.16 36.44 38.31
EER Cooling 4.11 3.94 3.44 3.53 3.31 4.01 3.94 3.65 3.44 3.52 3.36 3.41 3.31 3.57 3.44 3.50 3.38 3.44 3.34 3.37 3.31
W/W
COP Heating 4.39 4.30 3.90 4.13 3.92 4.34 4.30 4.07 3.90 4.05 3.91 4.01 3.92 4.01 3.90 4.00 3.91 4.00 3.91 3.98 3.92
Air flow rate High m3/h 11,100 11,100 11,100 13,000 13,000 11,100×2 11,100×2 11,100×2 11,100×2 13,000+11,100 13,000+11,100 13,000×2 13,000×2 11,100×3 11,100×3 13,000+11,100×2 13,000+11,100×2 13,000×2+11,100 13,000×2+11,100 13,000×3 13,000×3
Model name AJY144GALHH AJY198GALHH AJY216GALHH AJY234GALHH AJY252GALHH AJY270GALHH AJY288GALHH AJY306GALHH AJY324GALHH AJY342GALHH AJY360GALHH AJY378GALHH AJY396GALHH
Unit 1 AJYA72GALH AJY126GALH AJYA72GALH AJYA90GALH AJYA90GALH AJYA90GALH AJY126GALH AJY126GALH AJY126GALH AJY126GALH AJY144GALH AJY126GALH AJY144GALH
Unit 2 AJYA72GALH AJYA72GALH AJYA72GALH AJYA72GALH AJYA90GALH AJYA90GALH AJYA90GALH AJYA90GALH AJY126GALH AJY126GALH AJY126GALH AJY126GALH AJY126GALH
Unit 3 AJYA72GALH AJYA72GALH AJYA72GALH AJYA90GALH AJYA72GALH AJYA90GALH AJYA72GALH AJYA90GALH AJYA90GALH AJY126GALH AJY126GALH
Maximum Connectable Indoor Unit*1 24 33 36 39 42 45 48 51 54 57 60 64 64
Indoor unit connectable capacity Cooling kW 22.4-67.2 31.2-93.6 33.6-100.8 36.4-109.2 39.2-117.6 42.0-126.0 45.2-135.6 48.0-144.0 51.2-153.6 54.0-162.0 56.5-169.5 60.0-180.0 62.5-187.5
Power source 3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
Cooling 44.8 62.4 67.2 72.8 78.4 84.0 90.4 96.0 102.4 108.0 113.0 120.0 125.0
Capacity kW
Heating 50.0 70.0 75.0 81.5 88.0 94.5 101.5 108.0 115.0 121.5 126.5 135.0 140.0
Cooling 10.90 16.79 16.35 18.01 19.67 21.33 23.90 25.56 28.13 29.79 32.06 34.02 36.29
Input power kW
Heating 11.40 16.60 17.10 18.73 20.36 21.99 23.93 25.56 27.50 29.13 31.00 32.70 34.57
EER Cooling 4.11 3.72 4.11 4.04 3.99 3.94 3.78 3.76 3.64 3.63 3.52 3.53 3.44
W/W
COP Heating 4.39 4.22 4.39 4.35 4.32 4.30 4.24 4.23 4.18 4.17 4.08 4.13 4.05
Air flow rate High m3/h 11,100×2 13,000+11,100 11,100×3 11,100×3 11,100×3 11,100×3 13,000+11,100×2 13,000+11,100×2 13,000×2+11,100 13,000×2+11,100 13,000×2+11,100 13,000×3 13,000×3
66 67
Features
combination 3
Excellent energy saving
Heat pump inverter type realizes the highly energy COP 17% UP
2
saving air conditioning for individual cooling and heating 16 18 20 24* 26 28 30 32 34 36 38 40 42 44 48 (HP)
operation by all inverter technology for seasonal efficiency.
High design flexibility for Energy saving technology that boosted operation efficiency
various building air conditioning
High design flexibly meets the various needs of high-rise Powerful large propeller fan
building air conditioning such as outdoor unit roof top By using CFD*1 technology, a newly designed fan achieves high performance
concentrated installation and each floor installation by and low noise operation. *1. CFD = Computational Fluid Dynamics
large capacity combination, sufficient connection capacity,
and high static pressure design.
3 phase DC fan motor
Efficiency is substantially improved by high efficient motor with sophisticated
driver control. In addition, low noise is realized by DC fan motor.
Easy installation and maintenance
The flexible communication method and piping
connections makes installation and maintenance easy Subcool heat exchanger
even for large systems. High Heat Exchange efficiency is achieved by using an internal projection
shape double pipe construction.
0.1Hz
Capacity
Large Office System configuration example ALL DC inverter compressor
• This system is used for medium-sized and large buildings. Large capacity high efficient DC twin rotary compressor
Connecting each outdoor unit makes it possible to create a high- with 0.1Hz steps compressor speed control Inverter frequency
capacity system.
• Connection of multiple indoor units using separation tubes and 4-face heat exchanger
headers. Heat exchange efficiency is significantly improved by the introduction of a
new 4-face heat exchanger that increases effective surface area.
Outdoor unit
Front intake port (corner cut air inhaling structure)
Separation tube Header
Larger
g
refrigerant flow
Large intake airflow
68 69
Outdoor units lineup
• Combinations other than the followings are not recommended.
80 530
(Bolt pitch) 8-12 × 17 (Hole)
765 930
78.0 kW (28HP) 85.0 kW (30HP) 90.0 kW (32HP) 95.0 kW (34HP) 100.0 kW (36HP)
1690
1576
1339
AJY252LALBH AJY270LALBH AJY288LALBH AJY306LALBH AJY324LALBH
UNIT : AJY162/090LALBH UNIT : AJY144/126LALBH UNIT : AJY144/144LALBH UNIT : AJY162/144LALBH UNIT : AJY162/162LALBH
106.0 kW (38HP) 113.0 kW (40HP) 118.0 kW (42HP) 123.0 kW (44HP) 128.0 kW (46HP)
B A C
765 1240
44.8 kW (16HP) 50.4kW (18HP) 55.9 kW (20HP) 67.2 kW (24HP) 72.8 kW (26HP)
1690
AJY144LALBHH AJY162LALBHH AJY180LALBH AJY216LALBHH AJY234LALBHH
UNIT : AJY072/072LALBH UNIT : AJY090/072LALBH UNIT : AJY108/072LALBH UNIT : AJY072/072/072LALBH UNIT : AJY090/072/072LALBH
78.3 kW (28HP) 84.8 kW (30HP) 89.4 kW (32HP) 95.9 kW (34HP) 100.5 kW (36HP)
B A C
80
Power supply
cable port Ø 43.7
Ø 22.2 Power supply cable port
Transmission cable port
82
Ø 22.2
95
Ø 22.2
75
UNIT : AJY126/108/108LALBH UNIT : AJY126/126/108LALBH UNIT : AJY126/126/126LALBH UNIT : AJY144/126/108LALBH UNIT : AJY144/144/126LALBH 199
70 71
Outdoor units specifications
Model name AJY072LALBH AJY090LALBH AJY108LALBH AJY126LALBH AJY144LALBH AJY162LALBH AJY180LALBH AJY198LALBH AJY216LALBH AJY234LALBH AJY252LALBH AJY270LALBH AJY288LALBH AJY306LALBH AJY324LALBH AJY342LALBH AJY360LALBH AJY378LALBH AJY396LALBH AJY414LALBH AJY432LALBH AJY450LALBH AJY468LALBH AJY486LALBH
Unit 1 AJY072LALBH AJY090LALBH AJY108LALBH AJY126LALBH AJY144LALBH AJY162LALBH AJY090LALBH AJY126LALBH AJY126LALBH AJY144LALBH AJY162LALBH AJY144LALBH AJY144LALBH AJY162LALBH AJY162LALBH AJY162LALBH AJY144LALBH AJY144LALBH AJY162LALBH AJY162LALBH AJY144LALBH AJY162LALBH AJY162LALBH AJY162LALBH
Unit 2 AJY090LALBH AJY072LALBH AJY090LALBH AJY090LALBH AJY090LALBH AJY126LALBH AJY144LALBH AJY144LALBH AJY162LALBH AJY090LALBH AJY126LALBH AJY144LALBH AJY144LALBH AJY162LALBH AJY144LALBH AJY144LALBH AJY162LALBH AJY162LALBH
Unit 3 AJY090LALBH AJY090LALBH AJY090LALBH AJY090LALBH AJY090LALBH AJY144LALBH AJY144LALBH AJY144LALBH AJY162LALBH
Maximum Connectable Indoor Unit*1 17 21 26 30 34 39 43 47 52 56 60 64 64 64 64 64 64 64 64 64 64 64 64 64
Indoor unit connectable capacity Cooling kW 11.2-33.6 14.0-42.0 16.8-50.2 20.0-60.0 22.5-67.5 25.0-67.5 28.0-84.0 31.2-93.6 34.0-102.0 36.5-109.5 39.0-109.5 42.5-127.5 45.0-135.0 47.5-135.0 50.0-135.0 53.0-151.5 56.5-169.5 59.0-177.0 61.5-177.0 64.0-177.0 67.5-202.5 70.0-202.5 72.5-202.5 75.0-202.5
Power source 3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
Cooling 22.4 28.0 33.5 40.0 45.0 50.0 56.0 62.4 68.0 73.0 78.0 85.0 90.0 95.0 100.0 106.0 113.0 118.0 123.0 128.0 135.0 140.0 145.0 150.0
Capacity kW
Heating 25.0 31.5 37.5 45.0 50.0 50.0 63.0 70.0 76.5 81.5 81.5 95.0 100.0 100.0 100.0 113.0 126.5 131.5 131.5 131.5 150.0 150.0 150.0 150.0
Cooling 5.20 7.28 8.96 10.96 13.01 16.56 14.56 16.16 18.24 20.29 23.84 23.97 26.02 29.57 33.12 31.12 31.25 33.30 36.85 40.40 39.03 42.58 46.13 49.68
Input power kW
Heating 5.17 7.25 8.65 11.17 13.63 13.63 14.50 16.34 18.42 20.88 20.88 24.80 27.26 27.26 27.26 28.13 32.05 34.51 34.51 34.51 40.89 40.89 40.89 40.89
EER Cooling 4.31 3.85 3.74 3.65 3.46 3.02 3.85 3.86 3.73 3.60 3.27 3.55 3.46 3.21 3.02 3.41 3.62 3.54 3.34 3.17 3.46 3.29 3.14 3.02
W/W
COP Heating 4.84 4.35 4.34 4.03 3.67 3.67 4.34 4.28 4.15 3.90 3.90 3.83 3.67 3.67 3.67 4.02 3.95 3.81 3.81 3.81 3.67 3.67 3.67 3.67
13,700+13,000+
Air flow rate High m3/h 11,100 11,100 13,000 13,000 13,700 13,700 11,100×2 13,000+11,100 13,000+11,100 13,000+11,100 13,700+11,100 13,700+13,000 13,700×2 13,700×2 13,700×2 13,700+11,100×2 13,700×2+11,100 13,700×2+11,100 13,700×2+11,100 13,700×3 13,700×3 13,700×3 13,700×3
11,100
Liquid 12.70 12.70 12.70 12.70 12.70 15.88 15.88 15.88 15.88 15.88 15.88 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05
Connection pipe diameter mm
Discharge Gas 22.22 22.22 28.58 28.58 28.58 28.58 28.58 34.92 34.92 34.92 34.92 34.92 34.92 34.92 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27
Cooling -15 to 46 -15 to 46 -15 to 46 -15 to 46 -15 to 46 -15 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46
Operation range ˚C
Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21
Model name AJY144LALBHH AJY162LALBHH AJY180LALBHH AJY216LALBHH AJY234LALBHH AJY252LALBHH AJY270LALBHH AJY288LALBHH AJY306LALBHH AJY324LALBHH AJY342LALBHH AJY360LALBHH AJY378LALBHH AJY396LALBHH AJY414LALBHH
Unit 1 AJY072LALBH AJY090LALBH AJY108LALBH AJY072LALBH AJY090LALBH AJY108LALBH AJY126LALBH AJY108LALBH AJY126LALBH AJY108LALBH AJY126LALBH AJY126LALBH AJY126LALBH AJY144LALBH AJY144LALBH
Unit 2 AJY072LALBH AJY072LALBH AJY072LALBH AJY072LALBH AJY072LALBH AJY072LALBH AJY072LALBH AJY108LALBH AJY108LALBH AJY108LALBH AJY108LALBH AJY126LALBH AJY126LALBH AJY126LALBH AJY144LALBH
Unit 3 AJY072LALBH AJY072LALBH AJY072LALBH AJY072LALBH AJY072LALBH AJY072LALBH AJY108LALBH AJY108LALBH AJY108LALBH AJY126LALBH AJY126LALBH AJY126LALBH
Maximum Connectable Indoor Unit*1 34 39 43 52 56 60 64 64 64 64 64 64 64
Indoor unit connectable capacity Cooling kW 22.4-67.2 25.2-75.6 28.0-83.8 33.6-100.8 36.4-109.2 39.2-117.4 42.4-127.2 44.7-134.1 48.0-143.8 50.3-150.7 53.5-160.5 56.8-170.2 60.0-180.0 62.5-187.5 65.0-195.0
Power source 3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
Cooling 44.8 50.4 55.9 67.2 72.8 78.3 84.8 89.4 95.9 100.5 107.0 113.5 120.0 125.0 130.0
Capacity kW
Heating 50.0 56.5 62.5 75.0 81.5 87.5 95.0 100.0 107.5 112.5 120.0 127.5 135.0 140.0 145.0
Cooling 10.40 12.48 14.16 15.60 17.68 19.36 21.36 23.12 25.12 26.88 28.88 30.88 32.88 34.93 36.98
Input power kW
Heating 10.34 12.42 13.82 15.51 17.59 18.99 21.51 22.47 24.99 25.95 28.47 30.99 33.51 35.97 38.43
EER Cooling 4.31 4.04 3.95 4.31 4.12 4.04 3.97 3.87 3.82 3.74 3.70 3.68 3.65 3.58 3.52
W/W
COP Heating 4.84 4.55 4.52 4.84 4.63 4.61 4.42 4.45 4.30 4.34 4.21 4.11 4.03 3.89 3.77
72 73
Features
combination 3
High ambient
operation design 52 °C
ambient
COP 17% UP
2
Possible to operate cooling up to 16 18 20 24* 26 28 30 32 34 36 38 40 42 44 48 (HP)
Cooling operation range
52ºC outdoor temperature
50 40 30
52
Outdoor temperature (°C)
0.1Hz
Capacity
Large Office
ice
c System configuration example DC inverter compressor
• This system is used for medium-sized and large buildings. Large capacity high efficient DC twin rotary compressor
Connecting each outdoor unit makes it possible to create a high- with 0.1Hz steps compressor speed control Inverter frequency
capacity system.
• Connection of multiple indoor units using separation tubes and 4-face heat exchanger
headers. Heat exchange efficiency is significantly improved by the introduction of a
new 4-face heat exchanger that increases effective surface area.
Outdoor unit
Front intake port (corner cut air inhaling structure)
Separation tube Header
Larger
g
refrigerant flow
Large intake airflow
74 75
Outdoor units lineup
• Combinations other than the followings are not recommended.
80 530
(Bolt pitch) 8-12 × 17 (Hole)
765 930
78.0 kW (28HP) 85.0 kW (30HP) 90.0 kW (32HP) 95.0 kW (34HP) 100.0 kW (36HP)
1690
1576
1339
AJY252LNLBH AJY270LNLBH AJY288LNLBH AJY306LNLBH AJY324LNLBH
UNIT : AJY162/090LNLBH UNIT : AJY144/126LNLBH UNIT : AJY144/144LNLBH UNIT : AJY162/144LNLBH UNIT : AJY162/162LNLBH
106.0 kW (38HP) 113.0 kW (40HP) 118.0 kW (42HP) 123.0 kW (44HP) 128.0 kW (46HP)
B A C
765 1240
44.8 kW (16HP) 50.4kW (18HP) 55.9 kW (20HP) 67.2 kW (24HP) 72.8 kW (26HP)
1690
AJY144LNLBHH AJY162LNLBHH AJY180LNLBHH AJY216LNLBHH AJY234LNLBHH
UNIT : AJY072/072LNLBH UNIT : AJY090/072LNLBH UNIT : AJY108/072LNLBH UNIT : AJY072/072/072LNLBH UNIT : AJY090/072/072LNLBH
78.3 kW (28HP) 84.8 kW (30HP) 89.4 kW (32HP) 95.9 kW (34HP) 100.5 kW (36HP)
B A C
80
Power supply
cable port Ø 43.7
Ø 22.2 Power supply cable port
Transmission cable port
82
Ø 22.2
95
Ø 22.2
75
UNIT : AJY126/108/108LNLBH UNIT : AJY126/126/108LNLBH UNIT : AJY126/126/126LNLBH UNIT : AJY144/126/126LNLBH UNIT : AJY144/144/126LNLBH 199
76 77
Outdoor units specifications
Model name AJY072LNLBH AJY090LNLBH AJY108LNLBH AJY126LNLBH AJY144LNLBH AJY162LNLBH AJY180LNLBH AJY198LNLBH AJY216LNLBH AJY234LNLBH AJY252LNLBH AJY270LNLBH AJY288LNLBH AJY306LNLBH AJY324LNLBH AJY342LNLBH AJY360LNLBH AJY378LNLBH AJY396LNLBH AJY414LNLBH AJY432LNLBH AJY450LNLBH AJY468LNLBH AJY486LNLBH
Unit 1 AJY072LNLBH AJY090LNLBH AJY108LNLBH AJY126LNLBH AJY144LNLBH AJY162LNLBH AJY090LNLBH AJY126LNLBH AJY126LNLBH AJY144LNLBH AJY162LNLBH AJY144LNLBH AJY144LNLBH AJY162LNLBH AJY162LNLBH AJY162LNLBH AJY144LNLBH AJY144LNLBH AJY162LNLBH AJY162LNLBH AJY144LNLBH AJY162LNLBH AJY162LNLBH AJY162LNLBH
Unit 2 AJY090LNLBH AJY072LNLBH AJY090LNLBH AJY090LNLBH AJY090LNLBH AJY126LNLBH AJY144LNLBH AJY144LNLBH AJY162LNLBH AJY090LNLBH AJY126LNLBH AJY144LNLBH AJY144LNLBH AJY162LNLBH AJY144LNLBH AJY144LNLBH AJY162LNLBH AJY162LNLBH
Unit 3 AJY090LNLBH AJY090LNLBH AJY090LNLBH AJY090LNLBH AJY090LNLBH AJY144LNLBH AJY144LNLBH AJY144LNLBH AJY162LNLBH
Maximum Connectable Indoor Unit 13 16 19 23 26 29 33 36 40 43 46 50 53 55 55 55 55 55 55 55 55 55 55 55
Indoor unit connectable capacity Cooling kW 11.2-29.1 14-36.4 16.8-43.5 20-52 22.5-58.5 25-65 28-72.8 31.2-81.1 34-88.4 36.5-94.9 39-101.4 42.5-110.5 45-117 47.5-123.5 50-130 53-137.8 56.5-146.9 59-153.4 61.5-159.9 64-166.4 67.5-175.5 70-182 72.5-188.5 75-195
Power source 3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
Cooling 22.4 28.0 33.5 40.0 45.0 50.0 56.0 62.4 68.0 73.0 78.0 85.0 90.0 95.0 100.0 106.0 113.0 118.0 123.0 128.0 135.0 140.0 145.0 150.0
kW
Heating 25.0 31.5 37.5 45.0 50.0 50.0 63.0 70.0 76.5 81.5 81.5 95.0 100.0 100.0 100.0 113.0 126.5 131.5 131.5 131.5 150.0 150.0 150.0 150.0
Capacity
Cooling 76400 95500 114300 136500 153500 170600 191000 212900 232000 249000 266100 290000 307000 324100 341200 361600 385500 402500 419600 436700 460500 477600 494700 511800
Btu/h
Heating 85300 107500 128000 153500 170600 170600 215000 238800 261000 278100 278100 324100 341200 341200 341200 385600 431600 448700 448700 448700 511800 511800 511800 511800
Cooling 5.20 7.28 8.96 10.96 13.01 16.56 14.56 16.16 18.24 20.29 23.84 23.97 26.02 29.57 33.12 31.12 31.25 33.30 36.85 40.40 39.03 42.58 46.13 49.68
Input power kW
T1 Heating 5.17 7.25 8.65 11.17 13.63 13.63 14.50 16.34 18.42 20.88 20.88 24.80 27.26 27.26 27.26 28.13 32.05 34.51 34.51 34.51 40.89 40.89 40.89 40.89
condition Cooling 9.2 12.0 15.0 17.7 20.7 26.1 - - - - - - - - - - - - - - - - - -
Current A
Heating 9.2 12.2 14.6 18.2 21.5 21.5 - - - - - - - - - - - - - - - - - -
EER Cooling 4.31 3.85 3.74 3.65 3.46 3.02 3.85 3.86 3.73 3.60 3.27 3.55 3.46 3.21 3.02 3.41 3.62 3.54 3.34 3.17 3.46 3.29 3.14 3.02
W/W
COP Heating 4.84 4.35 4.34 4.03 3.67 3.67 4.34 4.28 4.15 3.90 3.90 3.83 3.67 3.67 3.67 4.02 3.95 3.81 3.81 3.81 3.67 3.67 3.67 3.67
EER Cooling 14.7 13.1 12.8 12.5 11.8 10.3 13.1 13.2 12.7 12.3 11.2 12.1 11.8 11.0 10.3 11.6 12.3 12.1 11.4 10.8 11.8 11.2 10.7 10.3
Btu/h/W
COP Heating 16.5 14.8 14.8 13.7 12.5 12.5 14.8 14.6 14.2 13.3 13.3 13.1 12.5 12.5 12.5 13.7 13.5 13.0 13.0 13.0 12.5 12.5 12.5 12.5
kW 20.2 25.2 28.5 32 35.1 35.2 50.4 52.2 57.2 60.3 60.4 67.1 70.2 70.3 70.4 85.6 92.3 95.4 95.5 95.6 105.3 105.4 105.5 105.6
Capacity
Btu/h 68900 86000 97200 109200 119800 120100 172000 178100 195200 205800 206100 229000 239600 239900 240200 292100 315000 325600 325900 326200 359400 359700 360000 360300
T3 Input power kW 6.73 9.20 9.34 10.70 11.82 12.35 18.39 17.44 19.90 21.02 21.55 22.52 23.64 24.17 24.70 30.75 31.72 32.83 33.37 33.90 35.45 35.99 36.52 37.05
Cooling
condition Current A 10.8 14.5 14.7 16.9 18.6 19.2 - - - - - - - - - - - - - - - - - -
W/W 3.00 2.74 3.05 2.99 2.97 2.85 2.74 2.99 2.87 2.87 2.80 2.98 2.97 2.91 2.85 2.78 2.91 2.91 2.86 2.82 2.97 2.93 2.89 2.85
EER
Btu/h/W 10.23 9.35 10.40 10.20 10.14 9.72 9.35 10.21 9.81 9.79 9.56 10.17 10.14 9.93 9.72 9.50 9.93 9.92 9.77 9.62 10.14 10.00 9.86 9.72
Power factor % 90 92 92 92 92 93 - - - - - - - - - - - - - - - - - -
13,700+13,000+
Air flow rate High m3/h 11,100 11,100 13,000 13,000 13,700 13,700 11,100×2 13,000+11,100 13,000+11,100 13,700+11,100 13,700+11,100 13,700+13,000 13,700×2 13,700×2 13,700×2 13,700+11,100×2 13,700×2+11,100 13,700×2+11,100 13,700×2+11,100 13,700×3 13,700×3 13,700×3 13,700×3
11,100
Sound pressure level*2 / Cooling 56 / 77 58 / 79 57 / 78 60 / 81 62 / 83 63 / 84 61 / 82 61 / 82 62 / 83 63 / 84 64 / 85 64 / 85 65 / 88 66 / 87 66 / 87 65 / 86 65 / 86 66 / 87 66 / 87 67 / 87 67 / 88 67 / 88 67 / 88 68 / 89
dB (A)
Power level Heating 58 / 80 59 / 81 60 / 83 62 / 84 64 / 86 64 / 86 62 / 84 63 / 85 64 / 86 65 / 87 65 / 87 66 / 88 67 / 89 67 / 89 67 / 89 66 / 88 67 / 89 68 / 90 68 / 90 68 / 90 69 / 91 69 / 91 69 / 91 69 / 91
Maximum external static pressure Pa 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82
Compressor motor output kW 7.5 7.5 11 11 11 11 7.5×2 11.0+7.5 11.0+7.5 11.0+7.5 11.0+7.5 11.0×2 11.0×2 11.0×2 11.0×2 11.0+7.5×2 11.0×2+7.5 11.0×2+7.5 11.0×2+7.5 11.0×2+7.5 11.0×3 11.0×3 11.0×3 11.0×3
Heat exchanger fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin
Height 1690 1690 1690 1690 1690 1690 1690×2 1690×2 1690×2 1690×2 1690×2 1690×2 1690×2 1690×2 1690×2 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3
Dimensions Width mm 930 930 1240 1240 1240 1240 930×2 1240+930 1240+930 1240+930 1240+930 1240×2 1240×2 1240×2 1240×2 1240+930×2 1240×2+930 1240×2+930 1240×2+930 1240×2+930 1240×3 1240×3 1240×3 1240×3
Depth 765 765 765 765 765 765 765×2 765×2 765×2 765×2 765×2 765×2 765×2 765×2 765×2 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3
Weight kg 255 255 279 279 279 279 255×2 279+255 279+255 279+255 279+255 279×2 279×2 279×2 279×2 279+255×2 279×2+255 279×2+255 279×2+255 279×2+255 279×3 279×3 279×3 279×3
Type (Global Warming Potential) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088)
Refrigerant 11.8+11.7 11.8+11.7 11.8+11.7 11.8+11.7 11.8+11.7×2 11.8×2+11.7 11.8×2+11.7 11.8×2+11.7 11.8×2+11.7
Charge kg(CO2eq-T) 11.7(24.4) 11.7(24.4) 11.8(24.6) 11.8(24.6) 11.8(24.6) 11.8(24.6) 11.7×2(24.4×2) 11.8×2 (24.6×2) 11.8×2 (24.6×2) 11.8×2 (24.6×2) 11.8×2 (24.6×2) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3)
(24.6+24.4) (24.6+24.4) (24.6+24.4) (24.6+24.4) (24.6+24.4×2) (24.6×2+24.4) (24.6×2+24.4) (24.6×2+24.4) (24.6×2+24.4)
Liquid 12.70 12.70 12.70 12.70 12.70 15.88 15.88 15.88 15.88 15.88 15.88 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05
Connection pipe diameter mm
Discharge Gas 22.22 22.22 28.58 28.58 28.58 28.58 28.58 34.92 34.92 34.92 34.92 34.92 34.92 34.92 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27
Cooling -15 to 52 -15 to 52 -15 to 52 -15 to 52 -15 to 52 -15 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52
Operation range ˚C
Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21
Model name AJY144LNLBHH AJY162LNLBHH AJY180LNLBHH AJY216LNLBHH AJY234LNLBHH AJY252LNLBHH AJY270LNLBHH AJY288LNLBHH AJY306LNLBHH AJY324LNLBHH AJY342LNLBHH AJY360LNLBHH AJY378LNLBHH AJY396LNLBHH AJY414LNLBHH
Unit 1 AJY072LNLBH AJY090LNLBH AJY108LNLBH AJY072LNLBH AJY090LNLBH AJY108LNLBH AJY126LNLBH AJY108LNLBH AJY126LNLBH AJY108LNLBH AJY126LNLBH AJY126LNLBH AJY126LNLBH AJY144LNLBH AJY144LNLBH
Unit 2 AJY072LNLBH AJY072LNLBH AJY072LNLBH AJY072LNLBH AJY072LNLBH AJY072LNLBH AJY072LNLBH AJY108LNLBH AJY108LNLBH AJY108LNLBH AJY108LNLBH AJY126LNLBH AJY126LNLBH AJY126LNLBH AJY144LNLBH
Unit 3 AJY072LNLBH AJY072LNLBH AJY072LNLBH AJY072LNLBH AJY072LNLBH AJY072LNLBH AJY108LNLBH AJY108LNLBH AJY108LNLBH AJY126LNLBH AJY126LNLBH AJY126LNLBH
Maximum Connectable Indoor Unit 26 29 33 39 43 46 50 52 55 55 55 55 55 55 55
Indoor unit connectable capacity Cooling kW 22.4-58.2 25.2-65.5 28-72.6 33.6-87.3 36.4-94.6 39.2-101.7 42.4-110.2 44.7-116.2 48-124.6 50.3-130.6 53.5-139.1 56.8-147.5 60-156 62.5-162.5 65-169
Power source 3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
Cooling 44.8 50.4 55.9 67.2 72.8 78.3 84.8 89.4 95.9 100.5 107.0 113.5 120.0 125.0 130.0
kW
Heating 50.0 56.5 62.5 75.0 81.5 87.5 95.0 100.0 107.5 112.5 120.0 127.5 135.0 140.0 145.0
Capacity
Cooling 152800 171900 190700 229200 248300 267100 289300 305000 327200 342900 365100 387300 409500 426500 443500
Btu/h
Heating 170600 192800 213300 255900 278100 298600 324100 341300 366800 384000 409500 435000 460500 477600 494700
Cooling 10.40 12.48 14.16 15.60 17.68 19.36 21.36 23.12 25.12 26.88 28.88 30.88 32.88 34.93 36.98
Input power kW
T1 Heating 10.34 12.42 13.82 15.51 17.59 18.99 21.51 22.47 24.99 25.95 28.47 30.99 33.51 35.97 38.43
condition Cooling - - - - - - - - - - - - - - -
Current A
Heating - - - - - - - - - - - - - - -
EER Cooling 4.31 4.04 3.95 4.31 4.12 4.04 3.97 3.87 3.82 3.74 3.70 3.68 3.65 3.58 3.52
W/W
COP Heating 4.84 4.55 4.52 4.84 4.63 4.61 4.42 4.45 4.30 4.34 4.21 4.11 4.03 3.89 3.77
EER Cooling 14.7 13.8 13.5 14.7 14.0 13.8 13.5 13.2 13.0 12.8 12.6 12.5 12.5 12.2 12.0
Btu/h/W
COP Heating 16.5 15.5 15.4 16.5 15.8 15.7 15.1 15.2 14.7 14.8 14.4 14.0 13.7 13.3 12.9
kW 40.4 45.4 48.7 60.6 65.6 68.9 72.4 77.2 80.7 85.5 89.0 92.5 96.0 99.1 102.2
Capacity
Btu/h 137800 154900 166100 206700 223800 235000 247000 263300 275300 291600 303600 315600 327600 338200 348800
T3 Input power kW 13.47 15.93 16.08 20.20 22.66 22.81 24.17 25.42 26.78 28.03 29.39 30.75 32.11 33.22 34.34
Cooling
condition Current A - - - - - - - - - - - - - - -
W/W 3.00 2.85 3.03 3.00 2.89 3.02 3.00 3.04 3.01 3.05 3.03 3.01 2.99 2.98 2.98
EER
Btu/h/W 10.23 9.72 10.33 10.23 9.87 10.30 10.22 10.36 10.28 10.40 10.33 10.26 10.20 10.18 10.16
Power factor % - - - - - - - - - - - - - - -
13,000+ 13,000+ 13,000×2+ 13,000×2+
Air flow rate High m3/h 11,100×2 11,100×2 13,000+11,100 11,100×3 11,100×3 13,000×3 13,000×3 13,000×3 13,000×3 13,700+13,000×2 13,700×2+13,000
11,100×2 11,100×2 11,100 11,100
Sound pressure level*2 / Cooling 59 / 80 60 / 81 60 / 81 61 / 82 62 / 83 61 / 82 63 / 84 61 / 82 63 / 84 62 / 83 63 / 84 64 / 85 65 / 88 66 / 87 66 / 87
dB (A)
Power level Heating 61 / 83 62 / 84 62 / 85 63 / 85 63 / 85 64 / 86 65 / 87 64 / 87 65 / 88 65 / 88 66 / 88 66 / 88 67 / 89 68 / 90 68 / 90
Maximum external static pressure Pa 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82
Compressor motor output kW 7.5×2 7.5×2 11.0+7.5 7.5×3 7.5×3 11.0+7.5×2 11.0+7.5×2 11.0×2+7.5 11.0×2+7.5 11.0×3 11.0×3 11.0×3 11.0×3 11.0×3 11.0×3
Heat exchanger fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin
Height 1690×2 1690×2 1690×2 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3
Dimensions Width mm 930×2 930×2 1240+930 930×3 930×3 1240+930×2 1240+930×2 1240×2+930 1240×2+930 1240×3 1240×3 1240×3 1240×3 1240×3 1240×3
Depth 765×2 765×2 765×2 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3
Weight kg 255×2 255×2 279+255 255×3 255×3 279+255×2 279+255×2 279×2+255 279×2+255 279×3 279×3 279×3 279×3 279×3 279×3
Type (Global Warming Potential) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088)
Refrigerant 11.8+11.7 11.8+11.7×2 11.8+11.7×2 11.8×2+11.7 11.8×2+11.7 Note: Specifications are based on the following conditions.
Charge kg(CO2eq-T) 11.7×2 (24.4×2) 11.7×2 (24.4×2) 11.7×3 (24.4×3) 11.7×3 (24.4×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3)
(24.6+24.4) (24.6+24.4×2) (24.6+24.4×2) (24.6×2+24.4) (24.6×2+24.4) Cooling(T1): Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB
Liquid 12.70 15.88 15.88 15.88 15.88 15.88 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05
Connection pipe diameter mm Cooling(T3): Indoor temperature of 29°CDB / 19°CWB, and outdoor temperature of 46°CDB / 24°CWB
Discharge Gas 28.58 28.58 28.58 34.92 34.92 34.92 34.92 34.92 34.92 41.27 41.27 41.27 41.27 41.27 41.27
Cooling -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 Heating: Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Operation range ˚C
Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 Pipe length: 7.5m. Height difference between outdoor and indoor unit: 0m.
78 79
15 Type and 91 models available to meet
the requirements of any building design.
The AIRSTAGE indoor units were developed to be highly efficient, compact, low noise
and to have user friendly operation. With a variety of indoor units and capacities
available, Fujitsu General has an indoor unit to match any requirement which is easy
AIRSTAGE
TM
INDOOR UNITS LINE-UP
INDOOR UNITS
Compact Cassette (Grid type / Standard type)
4-way Flow Cassette
Circular Flow Cassette
Mini Duct
Slim Duct / Slim Concealed Floor
Medium Static Pressure Duct
High Static Pressure Duct
Large Airflow Duct
Compact Floor
Floor / Ceiling
Ceiling
Wall Mounted (EEV Internal / external)
80 81
AIRSTAGE Indoor units
TM
Capacity range (kW) 1.1 2.2 2.8 3.6 4.5 5.6 7.1 9.0 10.0 11.2 12.5 14.0 18.0 22.4 25.0 28.0
Compact Cassette
Grid type / Standard type AUXB04GBLH AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXB24GALH
(Slim type)
AUXD18GALH AUXD24GALH
4-way Flow
(Slim type)
AUXM018GLAH AUXM024GLAH AUXM030GLAH
Circular Flow
(Large type)
AUXK018GLAH AUXK024GLAH AUXK030GLAH AUXK034GLAH AUXK036GLAH AUXK045GLAH AUXK054GLAH
Mini Duct
(With drain pump)
ARXK04GCLH ARXK07GCLH ARXK09GCLH ARXK12GCLH ARXK14GCLH ARXK18GCLH ARXK24GCLH
Slim Duct
(With drain pump)
ARXD04GALH*3 ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH
(Compact type)
(Large type)
ARXN18GATH*2 ARXN24GATH*2 ARXN30GATH*2 ARXN34GATH*2 ARXN36GATH*2 ARXN45GATH*2
Floor
(Same as Ceiling models)
ABYA12GATH ABYA14GATH ABYA18GATH ABYA24GATH
Compact Floor
AGYA004GCAH AGYA007GCAH AGYA009GCAH AGYA012GCAH AGYA014GCAH
Ceiling Ceiling
ABYA12GATH ABYA14GATH ABYA18GATH ABYA24GATH ABYA30GATH ABYA36GATH ABYA45GATH ABYA54GATH
Wall Mounted
ASYA004GTAH ASYA007GTAH ASYA009GTAH ASYA012GCAH ASYA014GCAH ASYA18GBCH ASYA24GBCH ASYA030GTAH ASYA034GTAH
Wall Mounted
Wall Mounted With this model,
connection of
(EEV external) EV kit is necessary.
ASYE004GTAH ASYE007GTAH ASYE009GTAH ASYE012GCAH ASYE014GCAH
82 83
AIRSTAGE Indoor units
TM
Specifications
Model name AUXB04GBLH AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXB24GALH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8 3.6 4.5 5.6 7.1
Capacity kW
Heating 1.3 2.8 3.2 4.1 5.0 6.3 8.0
Compact and stylish panel design Flexible installation Input power W 23 25 25 29 35 36 84
High 530 540 550 600 680 710 1,030
&RPSDFWDQGVW\OLVKSDQHOGHVLJQÀWVWKHJULGW\SHFHLOLQJ,WLVDOLQHDU It is suitable for ceiling of
Airflow rate Med m3/h 420 / 450*1 450 450 530 590 580 830
design suitable for grid shape of 620mm × 620mm grid ceiling. grid type and it has high
Low 300 / 350*1 350 350 390 390 400 450
degree of freedom of
High 34 34 35 37 38 41 50
installation and it can be Sound pressure dB
Med 28 / 30*1 30 30 34 34 35 44
installed beside lighting level (A)
Low 21 / 25*1 25 25 27 27 27 30
and ventilation opening.
Dimensions (H × W × D) mm 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570
Weight kg 15 15 15 15 15 17 17
Connection Liquid (Flare) 6.35 6.35 6.35 6.35 6.35 9.52 9.52
pipe diameter
620mm
Gas (Flare) mm 9.52 12.70 12.70 12.70 12.70 15.88 15.88
Drain hose diameter (I.D./O.D.) 25 / 32
Model name UTG-UFYE-W / UTG-UFYC-W
Flexible installation Cassette Grille Dimensions (H×W×D) mm 49 × 620 × 620 / 49 × 700 × 700
Weight kg 2.3 / 2.6
Ceiling panel Note : Specifications are based on the following conditions. *1: This value is under cooling operation.
Max.
700mm &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
+HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
620
12 2.7 3.0
14 2.7 3.0
18 2.7 3.0
75
24 2.7 3.0
620
The air inlet grill can be installed in various directions, 135 250
Bottom view Top view
so maintenance is easy.
40 99
135 250
116
102
30
49
Optional parts
262
108
222
146
30
40
245
Air Outlet Shutter Plate: UTR-YDZB Side view
Flesh Air Intake Kit: UTZ-VXAA
124
30
58
Insulation Kit for High Humidity: UTZ-KXGC Control box Ceiling
Casette Grille: UTG-UFYC-W, UTG-UFYE-W Liquid pipe Gas pipe Side view
84 85
AIRSTAGE Indoor unitsTM
Specifications
Model name AUXD18GALH AUXD24GALH AUXA18GALH AUXA24GALH AUXA30GALH AUXA34GALH AUXA36GALH AUXA45GALH AUXA54GALH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 5.6 7.1 9.0 10.0 11.2 12.5 14.0
Capacity kW
Heating 6.3 8.0 6.3 8.0 10.0 11.2 12.5 14.0 16.0
High efficiency turbo fan with 3-dimensional blade Input power W 39 46 51 51 59 77 80 99 119
High 1,150 1,280 1,420 1,420 1,600 1,750 1,800 1,900 2,000
High efficiency airflow distribution has been achieved by the introduction of a 3
Previous turbo fan Airflow rate Med m3/h 940 1,040 1,230 1,230 1,300 1,300 1,300 1,370 1,370
dimensional blade which increases the air passing over the heat exchanger.
Air passing through the heat exchanger was uneven and the air would only flow Low 870 870 1,100 / 1,000*1 1,100 / 1,000*1 1,100 1,100 1,100 1,100 1,100
close to the ceiling. High 36 38 40 40 40 43 44 46 47
500mm 450mm
Sound pressure
Med
dB
30 33 36 36 38 38 38 39 39
level (A)
Low 29 29 33 / 31*1 33 / 31*1 33 33 33 33 33
Previous blade
3-dimensional blade Dimensions (H × W × D) mm 246 × 840 × 840 246 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840
Weight kg 22 22 27 27 27 27 27 27 27
Heat exchanger Connection Liquid (Flare) 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52
Heat exchanger < Motor side > Separation pipe diameter Gas (Flare) mm 15.88 15.88 15.88 15.88 15.88 19.05 19.05 19.05 19.05
< Motor side > phenomenon of
Wind velocity
Fast Quiet airflow
Drain hose diameter (I.D./O.D.)
Model name
25 / 32
UTG-UGYA-W
causes noise
No airflow separation Cassette Grille Dimensions (H×W×D) mm 50 × 950 × 950
Uneven airflow
Slow Weight kg 5.5
Note : Specifications are based on the following conditions. *1: This value is under cooling operation.
: Spin direction : Airflow direction : Turbulent flow noise &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
+HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Rear part
Ceiling opening
Bottom view Round louver happens by spreading airflow widely
860 to 910
950
699
420
Adjustment of hanger position is High ceiling mode
607
possible after installation This cassette can be installed up to a height of 4.2m (36/45/54). Drain hose
358
The maximum height from floor to ceiling (m) (Control) Box
Model code
Detachable Standard mode High ceiling mode 358 278 60
Grille corner 18 3.0 3.5 40
24 3.0 3.5
289(256)
30 3.2 3.6
200
34 3.2 3.6
Adjustment can be done
just taking off the corner part 36 3.2 4.2
142
142
10
140
44
45 3.2 4.2 Ceiling Liquid pipe Gas pipe
54 3.2 4.2 Wire hole
86 87
AIRSTAGE Indoor unitsTM
Specifications
Model name AUXM018GLAH AUXM024GLAH AUXM030GLAH AUXK018GLAH AUXK024GLAH AUXK030GLAH AUXK034GLAH AUXK036GLAH AUXK045GLAH AUXK054GLAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 9.0 5.6 7.1 9.0 10.0 11.2 12.5 14.0
Capacity kW
Heating 6.3 8.0 10.0 6.3 8.0 10.0 11.2 12.5 14.0 16.0
ble!
Weight kg 6.0
orta
Comf
Note : Specifications are based on the following conditions. When AUX*018GLAH is connected to the outdoor unit other than J-IIIL, pipe diameter should
&RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:% be Ø9.52/Ø15.88 (Liq/Gas)
+HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:% When AUXK036GLAH, AUXK045GLAH, and AUXK054GLAH are connected to the outdoor unit
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. other than J-IIIL, gas pipe diameter should be Ø19.05.
768
768
950
* Touch Panel Wired RC *Touch Panel Wired RC
950
298
200-205
200
256
Air Outlet Shutter Plate: UTR-YDZK
Efficient air conditioning based on the Insulation Kit for High Humidity: UTZ-KXRA Ceiling
39
39
Ceiling Liquid pipe Liquid pipe
room layout
Casette Grille: UTG-UKYC-W, UTG-UKYA-B Gas pipe Wire hole Gas pipe
88 89
AIRSTAGE Indoor units
TM
20 dB(A)
Auto Louver Grille Kit (Option)
7KLQGHVLJQSURYLGHVDFRPIRUWDEOH
this model to install in a quiet location. living environment over a wide area.
at 04 model $XWRPDWLFORXYHUJULOOHSURYLGHV
6-Step Speed comfortable air conditioning all the
Models (With drain pump)
High way down to the floor and matches
ARXK04GCLH the interior design well. (Optional)
ARXK07GCLH Med-H
ARXK09GCLH Med
ARXK04 ARXK07 ARXK09 ARXK12 ARXK14 ARXK18
ARXK12GCLH Med-L
Optional parts
ARXK14GCLH Low Remote Sensor Unit : UTY-XSZX
ARXK18GCLH IR Receiver Unit : UTB-YWC
Quiet
ARXK24GCLH Auto Louver Grille Kit : UTD-GXTA-W (for ARXK04/07/09/12/14GCLH)
* Compatible Remote Controller is as follows:
UTY-RNRYZ2 / UTY-RLRY / UTY-RSRY / UTY-RHRY / UTY-DCGY / UTY-DTGYZ1 / UTY-ALGXZ1 / UTY-APGXZ1 UTD-GXTB-W (for ARXK18GCLH)
UTD-GXTC-W (for ARXK24GCLH)
ARXK24
Specifications
Model name ARXK04GCLH ARXK07GCLH ARXK09GCLH ARXK12GCLH ARXK14GCLH ARXK18GCLH ARXK24GCLH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8 3.6 4.5 5.6 7.1
Capacity kW
Heating 1.3 2.8 3.2 4.0 5.0 6.3 8.0
Large living space available Input power W 26 28 28 35 66 73 80
High 460 460 460 550 760 930 1,160
,QVWDOODWLRQVSDFHFDQEHUHGXFHGGRZQWRPLQLPXP Med-H 440 Ƥ Ƥ Ƥ Ƥ Ƥ Ƥ
depth 450mm height 198 mm and compact design (Unit: mm)
Airflow rate
Med
m3/h
420 420 420 480 560 740 960
0LQLPXPVL]H'HSWKPP+HLJKWPP9ROXPH Med-L 400 Ƥ Ƥ Ƥ Ƥ Ƥ Ƥ
Low 370 370 370 410 410 540 750
30% down compared with current model
Quiet 340 Ƥ Ƥ Ƥ Ƥ Ƥ Ƥ
/LJKWZHLJKWNJGRZQ
Static pressure range 0 to 30 0 to 30 0 to 30 0 to 30 0 to 50 0 to 50 0 to 50
450
Pa
Standard static pressure 10 10 10 10 15 15 15
High 25 26 26 29 34 33 32
Med-H 24 25 25 27 31 30 30
Optimum airflow path and low noise operation Easy design and maintenance for drain Dimensions (Unit: mm)
775 52
Low noise is realized drastically by stabilized airflow design By using the DC fan motor, it is possible to change the static pressure
range from 0 to 50 Pa*.
174
The change of static pressure range is possible by remote controller.
153
72
*: 0 to 30 Pa. (12) Rear view
295
30
Air Stabilizer
450
Parts can be replaced from the
150
182
193
10
side of the body where
maintenance is easier 1 Refrigerant pipe flare connection (Liquid)
View A
30
A
B 49 2 Refrigerant pipe flare connection (Gas)
High efficient DC fan motor
Lower power consumption C 56 78 3 Drain hose connection
49 66
Top view Side view
85 92
V-shape heat exchanger
169 ARXK04-14 ARXK18 ARXK24
57
43
A P100×6=600 P100×8=800 P100×10=1000
198
168
150 B 650 850 1050
78
(Drain hose) C 752 952 1152
33
D D 650 850 1050
E
E 665 864 1064
F
F 700 900 1100
Front view
90 91
AIRSTAGE Indoor units
TM
Slim Duct / Slim Concealed Floor Auto Louver Grille Kit (Option)
Simple flat Auto Louver will provide comfort airflow and harmonize
Optional parts
Remote Sensor Unit : UTY-XSZX
IR Receiver Unit : UTB-YWC
with luxury interior.
Auto Louver Grille Kit : UTD-GXTA-W (for ARXD04/07/09/12/14GALH)
Slim Duct Auto Louver Grille UTD-GXTB-W (for ARXD18GALH)
Models (With drain pump) UTD-GXTC-W (for ARXD24GALH)
ARXD04GALH
ARXD07GALH
ARXD09GALH ARXD04 ARXD07 ARXD09 ARXD12 ARXD14 ARXD18
ARXD12GALH
ARXD14GALH
ARXD18GALH
ARXD24GALH ARXD24
Wired Remote Wireles Remote
Controller Controller
Slim Concealed Floor
Specifications
Model name ARXD04GALH ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8 3.6 4.5 5.6 7.1
Capacity kW
Heating 1.3 2.8 3.2 4.0 5.0 6.3 8.0
Slim design Selectable with a wide range of Input power W 38 44 50 54 92 83 122
With a slim indoor design, this indoor can static pressure High 510 550 600 600 800 940 1,330
Airflow rate Med m3/h 400 / 470*1 490 550 510 710 840 1,240
be installed in narrow ceiling spaces. By using DC fan motor, it is possible to Low 320 / 440*1 440 480 450 610 750 1,100
Drain port change of static pressure range 0 to 90Pa. Static pressure range 0 to 90 0 to 90 0 to 90 0 to 90 0 to 90 0 to 90 0 to 50
Pa
The change of static pressure range is Standard static pressure 25 25 25 25 25 25 25
possible by remote controller. Static pressure range High 26 28 29 30 34 34 35
Height Sound pressure dB
198mm 0 to 90 Pa level
Med
(A)
21 / 25*1 25 26 27 32 32 32
Low 20 / 22*1 22 24 24 28 28 29
*24 model is 0 to 50Pa
Dimensions (H × W × D) mm 198 × 700 × 620 198 × 700 × 620 198 × 700 × 620 198 × 700 × 620 198 × 700 × 620 198 × 900 × 620 198 × 1,100 × 620
Drain pump
Drain pump built-in Weight kg 17 17 17 18 18 22 26
Connection Liquid (Flare) 6.35 6.35 6.35 6.35 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 12.70 12.70 12.70 12.70 12.70 15.88 15.88
High lift drain pump Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions. *1: This value is under cooling operation.
Air-intake &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
+HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Max. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Air intake direction can be selected
to match the installation site. 850mm
Bottom side Back side *Service accessibility must be allowed for when installing the product.
Please consult the installation manual for the necessary service access size.
Filter (Accessory) 51 G
174
152
71
30
ARXD04 / 07 / 09 / 12 / 14 / 18 ARXD24
Flexible installation (2pcs.) (3pcs.)
(Bolt pitch)
377
Ceiling concealed 82
48
30
F E
(All surroundings) D
C
(Bolt pitch) ARXD04-14 ARXD18 ARXD24
43 10
Floor concealed A 700 900 1100
163
119
198
168
89
78
55
47
78
92 93
AIRSTAGE Indoor units
TM
Models
ARXA24GBLH Duct indoor unit
ARXA30GBLH Two-direction drain piping
ARXA36GBLH
ARXA45GBLH
Easy setting by using remote controller Optional parts
Remote Sensor Unit : UTY-XSZX Flange (Round) : UTD-RF204
The change of static pressure
Long Life Filter : UTD-LF25NA IR Receiver Unit : UTB-YWC
range is possible by remote
Flange (Square) : UTD-SF045T Drain Pump Unit : UTZ-PX1NBA
controller
Specifications
Model name ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 7.1 9.0 11.2 12.5
Capacity kW
Heating 8.0 10.0 12.5 14.0
Slim & Compact design Input power W 94 108 194 240
1,200 1,135mm High 1,280 1,410 1,840 1,970
In the case of bottom return air connection, not only does the
Control box is now included as Airflow rate Med m3/h 990 1,280 1,600 1,860
indoor unit design allow for installation in a narrow ceiling
part of the main chassis Low 840 1,150 1,470 1,640
space of up to 270mm, Further space savings have been
Static pressure range 0 to 150 0 to 150 0 to 150 0 to 150
achieved by mounting the electrical control box internally Pa
270mm Standard static pressure 40 50 50 60
inside the chassis.
High 31 34 37 41
Sound pressure dB
Med 27 32 35 38
level (A)
Low 23 29 33 36
One touch operating and easy to Dimensions (H × W × D) mm 270 × 1,135 × 700 270 × 1,135 × 700 270 × 1,135 × 700 270 × 1,135 × 700
install long life filter (Optional Parts)
Weight kg 36 40 40 40
Connection Liquid (Flare) 9.52 9.52 9.52 9.52
pipe diameter Gas (Flare) mm 15.88 15.88 19.05 19.05
Drain hose diameter (I.D./O.D.) 25 / 32
Low energy consumption by high Easy maintenance Note : Specifications are based on the following conditions.
efficiency DC fan motor See below for the case of rear suction type
&RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
+HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Improved motor efficiency 1
from previous model. Previous model 3
24 model 30 / 36 / 45 model
168
32 32
high-rise condominiums by low static ø200
(knock 1
pressure design. out hole)
240
240
138
281
264 264 264
New model 1 3
447(Bolt pitch)
82
138
700
4
It can also be installed in wide spade 3
2
when high static pressure is required,
such as for offices.
161
75
173
3 ø205 hole
1.Control box 2
2.Fan casing Front view
3.Fan
Bottom panel: P.C.D. ø225
4.Motor 240
2 pieces 1015 107
270
121 1135
94 95
AIRSTAGE Indoor units
TM
High Static Pressure Duct Easy installation (Compact size & Lightweight)
A compact size and lightweight (Unit:mm)
indoor unit has been developed
by reducing the basic chassis
Models Models and the overall material weight.
400
550
Models
450
ARXC36GBTH ARXC72GBTH ARXC96GATH
ARXC45GATH ARXC90GBTH 1,050 500 1,587 700
1,587 700
ARXC60GATH (ARXC36 / 45 / 60 type) (ARXC72 / 90 type) (ARXC96 type)
Optional parts
Long-Life Filter : UTD-LF60KA (For ARXC36 / 45 / 60)
IR Receiver Unit : UTB-YWC
Remote Sensor Unit : UTY-XSZX
ARXC96
Specifications
Model name ARXC36GBTH ARXC45GATH ARXC60GATH* ARXC72GBTH* ARXC90GBTH* ARXC96GATH*
Feature Power source Single - phase, ~230V, 50Hz
Cooling 11.2 12.5 18.0 22.4 25.0 28.0
Capacity kW
Heating 12.5 14.0 20.0 25.0 28.0 31.5
Static pressure selection Input power W 207 715 730 681 819 838
High 1,990 3,500 3,500 3,900 4,300 4,850
By using DC fan motor, it is possible to change static pressure range from 0 to 200Pa (ARXC36) / 300Pa (ARXC72 / 90 / 96).
Airflow rate Med m3/h 1,680 3,000 3,000 3,300 4,000 4,250
Low 1,330 2,460 2,460 3,000 3,500 3,600
>3D@
Static pressure range 0 to 200 100 to 250 100 to 250 0 to 300 0 to 300 0 to 300
RU MAX. Pa
Standard static pressure 100 100 100 150 150 150
200 Pa High 42 49 49 47 48 48
Sound pressure dB
Med 36 45 45 43 46 45
(ARXC36 / 45 / 60 type) level (A)
Low 32 42 42 40 44 42
Dimensions (H × W × D) mm 400 × 1,050 × 500 400 × 1,050 × 500 400 × 1,050 × 500 450 × 1,587 × 700 450 × 1,587 × 700 550 × 1,587 × 700
MAX. Weight kg 40 46 46 84 84 105
300 Pa Connection
pipe diameter
Liquid
Gas mm
9.52 (Flare)
19.05 (Flare)
9.52 (Flare)
19.05 (Flare)
9.52 (Flare)
19.05 (Flare)
12.70 (Brazing)
22.22 (Brazing)
12.70 (Brazing)
22.22 (Brazing)
12.70 (Brazing)
22.22 (Brazing)
(ARXC72 / 90 type) Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions. *: ARXC60/72/90/96G cannot be connected to J-III series.
&RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
MAX. +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
0
[m3K@
300 Pa Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
fan casing, has enabled less turbulent air flow. Low noise is realized from previous model.
527
427
504
404
by adopting a plastic case and a plastic fan.
411
311
327
227
71 Rear view 81 Rear view 81
Rear view
42
42
371 1587 1587
400 1,080(Bolt pitch) 356 450 8 1410(BOLT PITCH) 550 1410 (BOLT PITCH)
324 1,000 208 370 15 470 15 8
14 1250 149 1250 149
38
65 65
38
862 108
29
123
139
(ARXC36 type) (ARXC72 / 90 / 96 type)
653(BOLT PITCH) 29
41
653(BOLT PITCH)
25
50
New model 500(Bolt pitch)
50
25
1
700
700
585
2
(ARXC36GBTH)
50
25
3
50
25
4 P160×2 Ø3 150×7=1050 75 P160×2 P150×7=1050 75
Side view (R) =320 15 Side view (R) =320 15 1200 125
851 1200 125
295 350 35 1450 117 350 35 1450 117
1,050 85
Side view (L) Top view Side view (L) Top view Side view (L) Top view
96 97
AIRSTAGE Indoor units
TM
ARXN018
ARXN024 ARXN030
Specifications
Model name ARXN018GLBH ARXN024GTBH ARXN030GTBH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 9.0
Capacity kW
Heating 6.3 8.0 10.0
Large airflow volume Input power W 173 180 273
High 1,720 2,100 2,700
It can be installed in places such as early replacement of air Med-H - 2,050 2,390
required by large airflow volume. Airflow rate
Med
m3/h
1,470 1,860 2,080
Med-L - 1,660 1,770
Low 1,360 1,470 1,470
Quiet - 1,260 1,260
Static pressure range 0 to 80 0 to 100 0 to 100
Pa
Standard static pressure 50 50 50
High 36 37 41
Med-H - 35 38
Sound pressure Med dB 33 33 34
level Med-L (A) - 31 31
Low 30 28 28
Quiet - 26 26
Dimensions (H × W × D) mm 270 × 1,135 × 700 300 × 1,400 × 700 300 × 1,400 × 700
Weight kg 40 48 48
Connection Liquid (Flare) 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 12.70 15.88 15.88
Slim & Compact design Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions.
It can be installed in places such as early replacement of air required &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
by large airflow volume. +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
(unit: mm) Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
168
Outlet 1295
32 32
ARXN018 ARXN024 / 030 ø200
Ø125
(knock 1
out hole)
240
240
281
3 Gas pipe
447(Bolt pitch)
Liquid pipe
Quiet operation
631
700
700
3
2 Air
Multistep airflow speed control allows this model
161
173
to install in a quiet location. Low noise
6-Step Speed
26 dB(A)
P.C.D. ø225 1015 107 240 1162
121 1135 270 1400 Drain port Drain port
High
Side view (L) Top view Side view (R) Side View (L) Top View Side View (R)
98
at 024/030 models Med-H
217
Med
Rear view Front View
Med-L
98 99
AIRSTAGE Indoor units
TM
Specifications
Model name ARXN18GATH ARXN24GATH ARXN30GATH ARXN34GATH ARXN36GATH ARXN45GATH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 9.0 10.0 11.2 12.5
Capacity kW
Heating 6.3 8.0 10.0 11.2 12.5 14.0
Large airflow volume Input power W 154 205 306 432 572 572
High 2,280 2,640 3,200 3,720 4,120 4,120
It can be installed in places such as early replacement of air
Airflow rate Med m3/h Ƅ Ƅ Ƅ Ƅ Ƅ Ƅ
required by large airflow volume.
Low Ƅ Ƅ Ƅ Ƅ Ƅ Ƅ
Static pressure range 50 to 100 50 to 150 50 to 250 50 to 250 50 to 300 50 to 300
Pa
Standard static pressure 50 50 50 50 60 60
High 35 37 40 43 45 45
Sound pressure dB
Med Ƅ Ƅ Ƅ Ƅ Ƅ Ƅ
level (A)
Low Ƅ Ƅ Ƅ Ƅ Ƅ Ƅ
Dimensions (H × W × D) mm 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700
Weight kg 84 84 84 84 84 84
Connection Liquid (Flare) 9.52 9.52 9.52 9.52 9.52 9.52
pipe diameter Gas (Flare) mm 15.88 15.88 15.88 15.88 19.05 19.05
Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions. Large Airflow Duct can be connected to V-III series only.
&RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
+HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Rear view
50 to 250 Pa 50 to 300 Pa
(30 / 34class) (36 / 45class) Air Flow
Top view
Optional parts
Remote Sensor Unit : UTY-XSZX Front view
100 101
AIRSTAGE Indoor units TM
Compact floor
Models (EEV internal) Models (EEV external)
AGYA004GCAH AGYE004GCAH
AGYA007GCAH AGYE007GCAH
AGYA009GCAH AGYE009GCAH
AGYA012GCAH AGYE012GCAH
AGYA014GCAH AGYE014GCAH
Specifications
Model name AGYA004GCAH AGYA007GCAH AGYA009GCAH AGYA012GCAH AGYA014GCAH AGYE004GCAH AGYE007GCAH AGYE009GCAH AGYE012GCAH AGYE014GCAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8 3.6 4.0 1.1 2.2 2.8 3.6 4.0
Capacity kW
Heating 1.3 2.8 3.2 4.0 4.5 1.3 2.8 3.2 4.0 4.5
2-Fan & Wide airflow Flexible & easy installation Input power W 12 / 14 16 17 22 29 12 / 14 16 17 22 29
High 380 / 430 470 500 590 670 380 / 430 470 500 590 670
Individual vertical airflow by 2-fan can control the whole room Due to compact and whole surface suction method model, floor, Med-H 350 420 450 520 590 350 420 450 520 590
comfortably. concealed, half concealed, or wall mounted installation can be Med 320 390 400 470 520 320 390 400 470 520
Airflow rate m3/h
available to match the room layout. Med-L 310 360 360 420 450 310 360 360 420 450
Low 280 330 330 390 390 280 330 330 390 390
Cooling Prevents cold air Beneath standard window Standard concave portion Quiet 210 270 270 340 340 210 270 270 340 340
from falling
(unit:mm) Min.900
High 35 / 36 37 38 42 46 35 / 36 37 38 42 46
Med-H 33 35 36 39 42 33 35 36 39 42
at stable
operation Min. 730 Max.
Max. 150 80 Dimensions (Unit: mm)
200
600
Med-H
Back view
Med
Med-L
1 6
Low
2 5
Quiet 3 Drain hose 4
Piping 740
* Compatible Remote Controller is as follows:
UTY-RNRYZ2 / UTY-RLRY / UTY-RSRY / UTY-RHRY / UTY-DCGY / UTY-DTGYZ1 / UTY-ALGXZ1 / UTY-APGXZ1 Front view Side view
102 103
AIRSTAGE Indoor units
TM
Models
ABYA12GATH
ABYA14GATH Super vane
ABYA18GATH 655 Double Louvre Super vane with newly developed special
ABYA24GATH configuration boosts airflow sending cool air quickly to every corner
of the room.
Floor standing
990
199
Specifications
Model name ABYA12GATH ABYA14GATH ABYA18GATH ABYA24GATH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 3.6 4.5 5.6 7.1
Capacity kW
Heating 4.0 5.0 6.3 8.0
Flexible installation Input power W 30 42 74 99
High 660 780 1,000 1,000
Example for floor installation Example for ceiling installation
Airflow rate Med m3/h 570 640 720 820
Floor console Under ceiling Low 490 550 580 680
High 36 40 46 47
Sound pressure dB
Med 32 36 39 42
level (A)
Low 28 34 35 37
Dimensions (H × W × D) mm 199 × 990 × 655 199 × 990 × 655 199 × 990 × 655 199 × 990 × 655
Weight kg 25 26 26 27
Connection Liquid (Flare) 6.35 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 12.70 12.70 15.88 15.88
Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions.
&RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
+HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
5 steps selectable
3 2
1
4
104 105
AIRSTAGE Indoor unitsTM
Fresh Max.
Models air
500mm
ABYA30GATH Indoor Outdoor
ABYA36GATH
ABYA45GATH
ABYA54GATH
Slim & Compact design
Specifications
Model name ABYA30GATH ABYA36GATH ABYA45GATH ABYA54GATH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 9.0 11.2 12.5 14.0
Capacity kW
Heating 10.0 12.5 14.0 16.0
Installation Input power W 66 85 131 180
High 1,630 1,690 2,010 2,270
Open Concealed Wall mounted Airflow rate Med m3/h 1,370 1,400 1,600 1,780
(Field Supplied)
Low 1,140 1,170 1,230 1,280
High 42 45 48 51
Sound pressure dB
Med 38 38 42 45
level (A)
Low 33 34 35 36
Dimensions (H × W × D) mm 240 × 1,660 × 700 240 × 1,660 × 700 240 × 1,660 × 700 240 × 1,660 × 700
Weight kg 46 48 48 48
Connection Liquid (Flare) 9.52 9.52 9.52 9.52
pipe diameter Gas (Flare) mm 15.88 19.05 19.05 19.05
Drain hose diameter (I.D./O.D.) 25 / 32
General installation pattern Installation pattern where part Installation which fixes the indoor unit to the
Note : Specifications are based on the following conditions.
which suspends the indoor of the indoor unit is embedded wall by the use of wall brackets (Field supplied). &RROLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
unit from the ceiling. into the ceiling. This type of installation can be used +HDWLQJ,QGRRUWHPSHUDWXUHRIÝ&'%Ý&:%DQGRXWGRRUWHPSHUDWXUHRIÝ&'%Ý&:%
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
when the ceiling space is insufficient.
low
air-f
nce
gd ista
Lon
5 steps selectable
High power DC fan motor
+LJKSRZHU:LGHURWDWLRQUDQJH+LJKHIILFLHQF\
Up and down
3
1 Refrigerant piping flare connection (Liquid)
4 2 Refrigerant piping flare connection (Gas) 3
4 steps selectable 3 Drain piping connection 2 1 3
106 107
AIRSTAGE Indoor units TM
Wall Mounted
Models (EEV internal) Models (EEV external)
ASYA004GTAH ASYE004GTAH
ASYA007GTAH ASYE007GTAH
ASYA009GTAH ASYE009GTAH
Specifications
Model name ASYA004GTAH ASYA007GTAH ASYA009GTAH ASYE004GTAH ASYE007GTAH ASYE009GTAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8 1.1 2.2 2.8
Capacity kW
Heating 1.3 2.8 3.2 1.3 2.8 3.2
High efficient compact design Input power W 13 19 34 13 19 34
High 430 550 720 430 550 720
Ø5mm high density heat exchanger is mounted for the first time in the industry. Med-H 420 460 570 420 460 570
Med 390 420 500 390 420 500
Airflow rate m3/h
Med-L 380 390 410 380 390 410
Low 360 360 360 360 360 360
Quiet 330 330 330 330 330 330
High 31 35 43 31 35 43
High density heat exchanger Med-H 30 32 38 30 32 38
Sound pressure Med dB 28 30 34 28 30 34
Making the tube thin: level Med-L (A) 26 27 29 26 27 29
7 mm 5 mm Dimensions (H × W × D)
Low
Quiet
mm
24
22
262×820×206
24
22
262×820×206
24
22
262×820×206
24
22
262×820×206
24
22
262×820×206
24
22
262×820×206
Increase of heat exchanger volume
Weight kg 7.5 7.5 7.5 7 7 7.5
by high density and adopting sub
Connection Liquid (Flare) 6.35 6.35 6.35 6.35 6.35 6.35
heat exchanger pipe diameter Gas (Flare) mm 9.52 9.52 9.52 9.52 9.52 9.52
Drain hose diameter (I.D./O.D.) 13.8 / 15.8 to 16.7
EV Kit (option) - - - UTR-EV09XB UTR-EV09XB UTR-EV09XB
Note : Specifications are based on the following conditions. When ASY*004GTAH, ASY*007GTAH, ASY*009GTAH are connected to the outdoor unit
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. other than J-IIIL, gas pipe diameter should be Ø12.70.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Med-H 262
Med
Med-L
Low
Quiet
Optimized design matches to a small room
* Compatible Remote Controller is as follows:
Efficient operation and refrigerant saving are realized by optimum
UTY-RNRYZ2 / UTY-RLRY / UTY-RSRY / UTY-RHRY / UTY-DCGY / UTY-DTGYZ1 / UTY-ALGXZ1 / UTY-APGXZ1 heat exchanger design suited for small rooms.
108 109
AIRSTAGE Indoor units TM
Wall Mounted
Models (EEV internal) Models (EEV external)
ASYA012GCAH ASYE012GCAH
ASYA014GCAH ASYE014GCAH
Specifications
Model name ASYA012GCAH ASYA014GCAH ASYE012GCAH ASYE014GCAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 3.6 4.0 3.6 4.0
Capacity kW
Heating 4.0 4.5 4.0 4.5
High efficient compact design Human sensor increases Input power W 25 36 25 36
High efficient compact design is realized by mounting a high density more energy saving High
Med-H
690
610
800
740
690
610
800
740
and large heat exchanger. Med 560 680 560 680
Energy saving operation starts automatically by Airflow rate m3/h
Compact body makes it possible to install inconspicuously even in a Med-L 530 610 530 610
detecting the motion of a person. 2 modes of save
meeting or office room and comfortable air conditioning is provided. Low 470 550 470 550
operation mode and stop mode can be selected. Human sensor
Quiet 330 330 330 330
High 40 44 40 44
People go out. People come back. Med-H 37 42 37 42
Sound pressure Med dB 35 40 35 40
level Med-L (A) 33 37 33 37
Low 30 34 30 34
Quiet 24 24 24 24
Dimensions (H × W × D) mm 268 × 840 × 203 268 × 840 × 203 268 × 840 × 203 268 × 840 × 203
Weight kg 8.5 8.5 8.5 8.5
Connection Liquid (Flare) 6.35 6.35 6.35 6.35
pipe diameter Gas (Flare) mm 12.70 12.70 12.70 12.70
Drain hose diameter (I.D./O.D.) 13.8 / 15.8 to 16.7
EV Kit (option) - - UTR-EV14XB UTR-EV14XB
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
High density heat exchanger
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Even temperature 6 Fan Speed Control
7 mm 5 mm
Making the Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
tube thin: Fan speed Low noise
Multistep airflow control
Increase of heat exchanger volume by high
density and adopting sub heat exchanger
Improved
heat exchanger is possible to suit the Quiet 24 dB(A) Dimensions (Unit: mm)
effectiveness
environment.
6-Step Speed
High
Heating Low
Vertical airflow provides Quiet
powerful floor level heating
268
* Compatible Remote Controller is as follows:
Power diffuser UTY-RNRYZ2 / UTY-RLRY / UTY-RSRY / UTY-RHRY / UTY-DCGY / UTY-DTGYZ1 / UTY-ALGXZ1 / UTY-APGXZ1
Cooling
Horizontal airflow does not blow
cool air directly at the occupants
Optional parts
in the room. Wired Remote Controller: UTY-RNRYZ2, UTY-RLRY
Wireless Remote Controller: UTY-LNHY
Power diffuser
Simple Remote Controller: UTY-RSRY, UTY-RHRY
110 111
AIRSTAGE Indoor units
TM
Wall Mounted
Models Models
ASYA18GBCH ASYA030GTAH
ASYA24GBCH ASYA034GTAH
ASYA18 ASYA24
ASYA030 ASYA034
Specifications
Model name ASYA18GBCH ASYA24GBCH ASYA030GTAH ASYA034GTAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 9.0 10.0
Capacity kW
Heating 6.3 8.0 10.0 11.2
Powerful & Comfort airflow Input power W 32 60 74 103
High 840 1,100 1,440 1,620 / 1,520
Powerful Airflow Power diffuser
Med-H - - 1,200 1,300
(ASYA030GTAH) (ASYA18/24GBCH) Med 770 910 1,050 1,120
Airflow rate m3/h
Med-L - - 940 980
Vertical airflow Horizontal airflow Low 690 730 890 890
(24) (24) Quiet - - 700 700
High 41 48 53 55 / 54
Med-H - - 49 51
Airflow Med 39 43 45 47
Sound pressure dB
20% up! level Med-L (A) - - 42 43
320
340
Drastic low noise is realized by new
airflow structure. In addition, multistep -2 dB(A) High
25
Low
Quiet
1 Refrigerant piping flare connection (Liquid)
Current model New model 2 Refrigerant piping flare connection (Gas)
* Compatible Remote Controller is as follows:
(030/034class) UTY-RNRYZ2 / UTY-RLRY / UTY-RSRY / UTY-RHRY / UTY-DCGY / UTY-DTGYZ1 / UTY-ALGXZ1 / UTY-APGXZ1 3 Drain piping connection
112 113
User friendly control system
provides individual control to centralized control
The AIRSTAGE control system can perform air conditioning control of individual
application, such as linking with the building control system, linking with a single split
AIRSTAGE
TM
CONTROL SYSTEM
CONTROL SYSTEMS
CONTROL SYSTEM OVERVIEW
INDIVIDUAL CONTROLLER
CENTRALIZED CONTROLLER
CONVERTOR / ADAPTOR
114 115
AIRSTAGE Control Systems TM
SHOP OFFICE
Individual Individual
Type Control
Centralized Control Integrating Control (Interface) Type Control
Centralized Control Integrating Control (Interface)
UTY-RNRYZ2, UTY-APGXZ1, UTY-VMSX, UTY-VKGX, UTY-RNRYZ2, UTY-RSRY, UTY-APGXZ1, UTY-ABGXZ1, UTY-VMSX UTY-VKGX
UTY-CGGY UTY-DCGY UTY-DTGYZ1 UTY-VLGX UTY-LNHY UTY-CGGY UTY-DCGY UTY-DTGYZ1 UTY-VLGX UTY-TERX
UTY-RLRY UTY-ALGXZ1 UTY-VMGX UTY-VKSX UTY-RLRY UTY-RHRY UTY-ALGXZ1 UTY-VBGX UTY-VMGX UTY-VKSX
Remote Management
116 117
AIRSTAGE Control Systems
TM
BACnet® Gateway
(Field supplied)
Max. controllable UTY-VBGX Hardware
Wired Remote Controller
UTY-RNRY System Controller Software 1600
Indoor units
*
BMS/BAS *2
UTY-APGXZ1 / UTY-ALGXZ1 (Lite edition)
Network Convertor For LONWORKS®
*: Lite edition is max. controllable 400 indoor units
UTY-VLGX
Remote/
Monitoring side
Simple Remote Controller
UTY-RSRY Internet or MODBUS® Convertor
UTY-RHRY Public
Without operation mode Telephone UTY-VMGX
Line
BMS, Home automation system
Max. controllable MODBUS® Interface
Wireless
Remote Controller Touch Panel Controller 400
Indoor units
FJ-RC-MBS-1
or
UTY-DTGYZ1
UTY-LNHY
KNX® Convertor For VRF *1. USB Adaptor: Echelon® U10 USB Network Interface
Central Remote UTY-VKGX *2. BMS/BAS: Building Management System/Building Automation System
Max. controllable
Controller
IR Receiver Unit
UTB-YWC For Duct type
UTY-DCGY 100
Indoor units KNX® Interface
UTY-LRHYB1 For Cassette type FJ-RC-KNX-1i
For Duct For Cassette
Signal Amplifier
UTY-VSGXZ1
118 119
AIRSTAGE Control Systems TM
Item
Wired Remote Controller Wired Remote Simple Remote Simple Remote Wireless Remote Group Remote Central Remote Touch Panel System Controller Lite System Controller
(Touch panel) Controller Controller Controller*1 Controller Controller Controller Controller Software Software
Model name UTY-RNRYZ2 UTY-RLRY UTY-RSRY UTY-RHRY UTY-LNHY UTY-CGGY UTY-DCGY UTY-DTGYZ1 UTY-ALGXZ1 UTY-APGXZ1
Max. controllable remote controller groups 1 1 1 1 1 8 100 400 400 1600
Max. controllable indoor units 16 16 16 16 16 128 100 400 400 1600
Max. controllable groups — — — — — — 16 400 400 1600
On / Off z z z z z z z z z z
Operation mode setting z z z — z z z z z z
Fan speed setting z z z z z z z z z z
Air conditioning control function
Address display z z z z — z z z z z
Room temp z — z z — — — z — —
Multi language z — — — — — z z z z
Summer time z — — — — — z z z z
Name registration z — — — — — z z z z
Backlight z — z z — — z z — —
'ÁRRUOD\RXW'EXLOGLQJGLVSOD\ — — — — — — — — — z
Refrigerant leakage detection function — — — — — — — z z z
Period Week Week — — — Week Week Year Year Year
Schedule timer On/off, Temp, Mode,
8 4 — — — 4 20 20 144 144
Times per day
On/off timer z z — — z — — — — —
Timer
Sleep timer — — — — z — — — — —
Program timer — — — — z — — — — —
Auto off timer z z — — — — — z — —
Day off z z — — — — z z z z
Min. unit of timer setting (Minutes) — — 5 10 10 10 10 10
Status monitoring system — — — — — — z z z z
Electricity charge apportionment — — — — — — — { { z
Error history z z — — — z z z z z
Emergency stop — — — — — — z*2 z*2 — —
Control
Remote management — — — — — — — z { z
Energy saving management — — — — — — — — { {
(PDLOQRWLÀFDWLRQIRUPDOIXQFWLRQ — — — — — — — z z z
z z z z z z z
Key lock — — —
Child lock Child lock Child lock Password setting Password setting Password setting Password setting
Low noise mode — — — — — — — z — —
*1 “Operation mode” setting is not available for this model. *2 This function is available only through external input control. z: Supported {: Optional function — : Not supported yet
120 121
AIRSTAGE Control Systems Individual Controller
TM
0DLQWDLQVVHSDUDWHVHWSRLQWVIRUKHDWLQJDQGFRROLQJ 7KHIDXOW\ZLULQJFDQEHSUHYHQWHGE\XVLQJQRQSRODUZLUH
87<515<= $XWRPDWLFDOO\FKDQJHVPRGHEHWZHHQKHDWLQJDQGFRROLQJ
* This function is not available for some models.
Easy operation by high-definition large STN-LCD touch panel screen I.U. Y1Y2 Y3 I.U. Y1Y2 Y3
Cooling set temp. 27ÝC, Heating set temp. 26ÝC
(DV\ILQJHUWRXFKRSHUDWLRQZLWK/&'SDQHO
%XLOWLQZHHNO\'DLO\WLPHU212))7HPS0RGH
%DFNOLJKWHQDEOHVHDV\RSHUDWLRQLQDGDUNHQHGURRP
5RRPWHPSHUDWXUHGLVSOD\ non-polar
Auto 2-wire
&RQWUROXSWRLQGRRUXQLWV
Operation Start
Changeover
&RUUHVSRQGVWRGLIIHUHQWODQJXDJHV
Change over
(English, Chinese, French, German, Spanish, Russian, Polish, Italian, Greek, Portuguese, Turkish and Dutch) OK OK
Cooling Set Point
ZLUHW\SH
Heating Set Point
Change over
Ex)
Easy Maintenance
Error History Display
7KHHUURUVWKDWRFFXULQWKHLQGRRUXQLWRU
Child lock
remote controller are saved as a history.
/RFNXQORFNPHWKRG3XVKWKH21 $PD[LPXPRIHUURULQFLGHQWVFDQEH
OFF button and the screen (4 seconds) saved.
Set Temperature Auto Return
7KHVHWWLQJWHPSHUDWXUHDXWRPDWLFDOO\UHWXUQVWRWKHSUHYLRXV
setting temperature.
7KHWLPHUDQJHLQZKLFKWKHVHWWHPSHUDWXUHFDQEHFKDQJHGLVWR
120 minutes.
Room temperature sensor Room temperature
display Set Temperature Upper and Lower Limit Setting
7KHVHWWHPSHUDWXUHUDQJHFDQEHVHWIRUHDFKRSHUDWLRQPRGH
Name Registration
(Cooling / Heating / Auto).
Backlight 5HPRWHFRQWUROOHUQDPHVFDQEH Initial Setting Page 1/ 3
)RUWKHOLJKWLQJWLPHRI%DFNOLJKW Specifications
the room.
or 60 seconds can be set.
Model name 87<515<=
%DFNOLJKWDFWLYDWHVZKLOHWKHEXWWRQV
Power Supply DC 12V
DUHRSHUDWHGDQGJRHVRIIRU
Dimensions (H x W x D) mm 120 × 120 × 20.4
seconds after the operation stops.
Weight g 220
DC12V is supplied by indoor unit.
122
AIRSTAGE Control Systems Individual Controller
TM
16 16
indoor units indoor units
87<5/5< 87<565<
87<5+5< (Without Operation mode)
9DULRXVWLPHUVHWXS212)):((./<DUHSRVVLEOH
7KHURRPWHPSHUDWXUHFDQEHFRQWUROOHGE\GHWHFWLQJWKHWHPSHUDWXUHDFFXUDWHO\ZLWK%XLOWLQWKHUPRVHQVRU
:KHQDIDLOXUHRFFXUVWKHHUURUFRGHLVGLVSOD\HG Compact remote controller provides access to basic functions
(UURUKLVWRU\/DVWHUURUFRGHVFDQEHDFFHVVHG
8SWRLQGRRUXQLWVFDQEHFRQWUROOHGZLWKRQHUHPRWHFRQWUROOHU
ZLUHW\SH
6XLWDEOHIRUKRWHOVRURIILFHVDVLWLVHDVLO\RSHUDWHGZLWKQRFRPSOH[IXQFWLRQV
6W\OLVKGHVLJQ6LPSOHGHVLJQWRPDWFKWKHVW\OLVKLQWHULRU
/DUJH/&'VFUHHQ VLPSOHRSHUDWLRQEXWWRQV
%DFNOLJKW:KLWHFRORUHGEDFNOLJKWRQPRQLWRUHQDEOHHDV\RSHUDWLRQLQGDUN
ZLUHW\SH
UTY-RSRY UTY-RHRY
Without Operation mode
Functions Functions
High performance and compact size High visibility and Corresponding to various applications
In addition to the individual control, weekly timer, and various energy easy operation 9HUWLFDOORXYHUFRQWURO
saving controls can be realized using only one remote controller. ´0RGHµ´6HW7HPSµDQG´)DQµDUH Vertical air flow direction can be adjusted for Duct types with
displayed at large size on the top screen. auto louver and Cassette types, which are installed in hotels and
(DFKIXQFWLRQWREHVHWLVLQGLFDWHGE\ conference rooms, can be adjusted.
Individual Thermo Weekly Auto OFF an icon. Sophisticated control buttons
control sensor timer timer Simple operation with easy
&RQWUROJXLGHLVGLVSOD\HGDQGRSHUDWLRQ
4-way navigation pad
is simple and straightforward.
Set contents can be displayed
clearer with large LCD.
Weekly timer function Set temperature upper and lower limit setting
1RWRQO\WLPHVHWWLQJ2Q2IIEXWDOVRVHWWLQJRIWKHRSHUDWLRQ 7KHVHWWHPSHUDWXUHUDQJHFDQEHVHWIRUHDFKRSHUDWLRQPRGH
Room temperature
mode and set temperature can be set by Weekly timer function. (Cooling / Heating / Auto)
sensor
ON OFF ON OFF During Cooling During Heating
24°C 30°C 30°C
25°C
Working hour Working hour 25°C
Specifications Specifications
Model name 87<5/5< Model name 87<565< 87<5+5<
Power Supply DC 12V Power Supply DC 12V
Dimensions (H x W x D) mm 120 × 120 × 17 Dimensions (H x W x D) mm 120 × 75 × 19.4
Weight g 170 Weight g 120
DC12V is supplied by indoor unit. DC12V is supplied by indoor unit.
124 125
AIRSTAGE Control Systems Individual Controller
TM
16 4
indoor units daily timers
87</1+< 87%<:&
Simple and sophisticated operations Duct type* indoor units can be controlled with Wireless Remote Controller
with a choice of 4 daily timers *Only Large Airflow Duct can not be connected to IR Receiver Unit.
$VLQJOHFRQWUROOHUFRQWUROVXSWRLQGRRUXQLWV 8SWRLQGRRUXQLWVFDQEHFRQWUROOHGZLWKRQHUHPRWHFRQWUROOHU
6XLWDEOHIRUKRWHOVRURIILFHVDVLWLVHDVLO\RSHUDWHGZLWKQRFRPSOH[IXQFWLRQV
Functions
Wiring connection
Functions
7 imer setting
60min.
IR Receiver Unit
Address setting 87</5+<%
2Ý&
1Ý& During installation work, address setting can be performed using the
Wireless Remote Controller, thus eliminating manual switch setting. Cassette type indoor unit can be controlled
with Wireless Remote Controller
Heating operation
Transmission line
When the sleep timer is set, the set temperature automatically drops
Ý&HYHU\PLQXWHV7KHVHWWHPSHUDWXUHFDQGURSWRDPD[RIÝ&
Indoor unit
Outdoor unit
1Ý&
2Ý&
Functions
Ý& Wireless
Ý& Remote Controller
PLQ
60min.
90min.
7 imer setting Wireless
Remote Controller
Specifications Specifications
Model name 87</1+< Model name 87</5+<%
Power Supply 95/5$$$î Power Supply DC 5V
Dimensions (H x W x D) mm 170 × 56 × 19 Dimensions (H x W x D) mm îî
Weight g 85 Weight g 140
126 127
AIRSTAGE Control Systems Centralized Controller
TM
8 92 indoor units in
2 100 16
remote controller
groups 8 Groups
refrigerant
circuits
indoor units groups
87<&**<87<9**;= 87<'&*<
Group control of indoor units with simple operation Central control of small- and medium-sized buildings and tenants. The operation
8SWRUHPRWHFRQWUROOHUJURXSVFDQEHFRQWUROOHGE\RQH*URXS5HPRWH&RQWUROOHU
status of all connected indoor units can be viewed at a glance on a large LCD monitor
8SWR*URXS5HPRWH&RQWUROOHUVFDQEHFRQQHFWHGLQRQH95)QHWZRUNV\VWHP to simplify individual control to batched control.
1HWZRUN&RQYHUWRULVUHTXLUHGWRFRQQHFW*URXS5HPRWH&RQWUROOHUVWRD95)
network system. (Network Convertor allows up to 4 Group Remote Controllers) ,QGLYLGXDOFRQWURODQGPRQLWRURILQGRRUXQLWV
ZLUHW\SH LQFK7)7FRORUVFUHHQ
8VHUIULHQGO\YLHZDQGHDV\RSHUDWLRQ
([WHUQDOLQSXWRXWSXWFRQWDFW
'HWDFKDEOHSRZHUVXSSO\XQLW
Group Remote Controllers Network Convertor &RUUHVSRQGVWRGLIIHUHQWODQJXDJHV(QJOLVK&KLQHVH)UHQFK*HUPDQ6SDQLVK5XVVLDQ3ROLVK
UTY-CGGY UTY-VGGXZ1
For Group Remote Controller
Functions Functions
Group : 3F
Single Group Remote Controller controls and monitors up to 8 remote controller groups. ,WDOORZVPXOWLSOHLQGRRU
Group : Division A Group : Division B Group : Division C
units grouping (Max.16
Refrigerant Refrigerant groups controlled)
system 1 system 2 ,QWHUORFNZLWKH[WHUQDO
device
Hotel Group : 2F
Restaurant
Lounge
Functions
Office room
'LYHUVHFRQWURORILQGRRUXQLWV 5HPRWHFRQWUROOHUSURKLELWLRQ :HHNO\WLPHU (UURUKLVWRU\ $XWRPDWLFFORFNDGMXVWPHQW
Network (All, On / Off, Mode, Temp, Timer, Filter)
Lobby Convertor
Group Remote Controller 1:
To control office room, lounge,
Restaurant restaurant and lobby
(8 remote controller groups)
Easy Installation
7KHFRQWUROSDQHODQGSRZHUVXSSO\XQLWFDQEHLQVWDOOHGVHSDUDWHO\ $XWRPDWLFRUPDQXDOLQGRRUXQLWUHJLVWUDWLRQ
)RUIOH[LELOLW\LQLQVWDOODWLRQWKH&RQWUROSDQHOFDQEHEXLOWLQWRWKH
High performance and compact size %XLOWLQZHHNO\WLPHUV wall or fix on the wall. Indoor unit registration
ON / OFF, Operating mode, Room temperature and Fan speed setting The weekly timer is provided as a standard function. Setting pattern 1 Setting pattern 2
can be controlled / monitored centrally or individually. Ceiling
Indoor unit registration
SW BOX start
Power supply unit
Power supply unit
Specifications
Model name 87<'&*<
Specifications
Control Panel Power Supply Unit
Model name 87<&**< Model name 87<9**;= Power Supply DC 5 V 100-240V, 50-60Hz, Single phase
Power Supply DC 12V Power Supply 208-240V 50/60Hz, Single phase Dimensions (H x W x D) mm 120 x 162 x 25.7 [[
Dimensions (H x W x D) mm 120 × 120 × 18 Input power W 8.5 Weight g
Weight g 200 Dimensions (H x W x D) mm 67 × 288 × 211 <PACKING LIST>
DC12V is supplied by indoor unit. Weight g 1,500 Packing List Control Panel / Power Supply Unit / Connecting cable, etc.
128 129
AIRSTAGE Control Systems Centralized Controller
TM
Internet. Nexus 6P (Android 7.1.1) Google Chrome 5.5 ipad Pro 9.7inch (iOS 10.2.1) Safari 10
HTXLSPHQWE\WKHLU3&RUWDEOHWIURPDQ\ZKHUH
(UURUFRQWHQWVDUHQRWLILHGDXWRPDWLFDOO\E\(PDLODW
error occurrence to handle the trouble promptly.
Flexible access permission for Point each level user.
Administrator can register multiple user to permit which indoor
unit(s) and which function can access.
AIRSTAGE Control Systems Centralized Controller
TM
FUNCTIONS SUMMARY
100% down Various energy saving control - z Emergency stop z*2 z*2
Capacity
0 Economy mode setting z z Remote management - z
Block (Tenant) A
Operating 58dB Human sensor control - z Energy saving management - -
sound
0 Display E-mail notification for malfunction - z
Block (Tenant) B
time
Quiet priority low noise mode Error z z z
Key lock -
Defrosting z z Password setting
Day of week z z
9DULRXVHQHUJ\VDYLQJFRQWURO
R.C. prohibition z z
Custom Auto Cooling set temp. 28ÝC, Heating set temp. 18ÝC
Cooling/heating priority z z
0DLQWDLQVVHSDUDWHVHWSRLQWVIRUKHDWLQJDQGFRROLQJ
$XWRPDWLFDOO\FKDQJHVPRGHEHWZHHQKHDWLQJDQGFRROLQJ Address display z z
Multi language z z
Auto
Operation Start
Changeover Summer time z z
Change over
Time zone setting z z
Cooling Set Point
Name registration z z
Heating Set Point
Backlight z z
Change over
Language setting 7 7+other
Memory operation z z
Refrigerant leakage detection function z : Supported : Optional function - : Not supported yet
*1 Only setting cancellation can be operated.
The refrigerant leak condition is indicated by the management *2 This function is available only through external input control.
HTXLSPHQWDQGLIUHIULJHUDQWOHDNDJHRFFXUVLWLVGLVSOD\HGDVD
pop-up, the user is notified, and the refrigerant is shut off.
Specifications
Model name 87<'7*<=
Power Supply 100-240V 50/60Hz, Single phase
Dimensions (H x W x D) mm 260 × 246 × 54
Weight g 2,150
Pop-up highlighting Interface Transmission / LAN / USB / EXT IN / EXT OUT / Reset SW
AIRSTAGE Control Systems Centralized Controller
TM
When Modbus Adaptor (locally purchased) is connected to PC, the electric facilities supported by Modbus can be controlled centrally.
87<$3*;= Wasteful electricity charge by forgetting to turn off and patrol activities can be reduced in the entire building.
6\VWHP&RQWUROOHUUHDOL]HVWKHDGYDQFHGLQWHJUDWHGPRQLWRULQJ FRQWURORI
VRF network system from small scale buildings to large scale buildings.
VRF Network
8SWRDPD[LPXPRI95)QHWZRUNV\VWHPVLQGRRUXQLWVDQGRXWGRRUXQLWV
can be controlled.
,QDGGLWLRQWRDLUFRQGLWLRQLQJSUHFLVLRQFRQWUROIXQFWLRQFHQWUDOUHPRWHFRQWURO Remote I/O Facilities
electricity charge calculation, schedule management, and energy saving functions are devices Energy recovery ventilator system
strengthened and building manager and owner needs are met.
Supported Modbus
communication Air handling unit (DX kit)
(Field supply)
Supply & Exhaust fan
87<$/*;=
3D display of external equipment
System Controller Lite has standard functions sufficient for air 'GLVSOD\LVDOVRHQDEOHGIRUUGSDUW\GHYLFHV 3D display operation
conditioner management in small and medium scale buildings. so Installation location and operation status 4F Outdoor unit
can be checked at a glance and the operation
8SWRDPD[LPXPRI95)QHWZRUNV\VWHPLQGRRUXQLWVDQGRXWGRRUXQLWVFDQ
can be managed easily.
be controlled. New
,QDGGLWLRQWRDLUFRQGLWLRQLQJSUHFLVLRQFRQWUROIXQFWLRQDYDULHW\RIPDQDJHPHQW UGSDUW\GHYLFH
software is available as an option to give customers a wide range of choice. 3F
Indoor unit
Functions 2F
Click & Operate the whole building ! Properties can be shown using one of the four
displays of site, building, floor, or list.
Click & Operate any specified unit(s)! Diverse operation management &
Data management
Schedule management
The display is easily changed by pressing the button. $QQXDOVFKHGXOHVFDQEHVHWIRUHDFKUHPRWHFRQWUROOHUJURXSXVHUGHILQHGJURXS
6WDUWVWRSRSHUDWLQJPRGHUHPRWHFRQWUROOHUSURKLELWLRQDQGWHPSHUDWXUH
VHWWLQJVFDQEHVHWXSWRWLPHVSHUGD\DWPLQXWHLQWHUYDOVIRUXSWR
configurations for each remote controller group.
6HWWLQJVFDQEHPDGHIRUSHULRGVVWUDGGOLQJPLGQLJKW
$OORZVSURJUDPPLQJRIVSHFLDOVHWWLQJVIRUKROLGD\VLQFOXGLQJSXEOLFKROLGD\VIRU
Site view List view
a complete year.
/RZQRLVHRSHUDWLRQRIRXWGRRUXQLWFDQEHVFKHGXOHG
AIRSTAGE Control Systems Centralized Controller
TM
Functions Remote management for System Controller for System Controller Lite UTY-PLGXA2
Building
communicate with the VRF Controller. Management Company B
(In charge of the night shift) Internet Office Management Center
or
VRF Controller and VRF Explorer program VRF Explorer
Telephone Line
or VRF Controller Internet
or
LAN
may run in a single PC or in different Telephone Line
or
WAN*2 (Intranet)
LAN
PCs separated by network. By using VRF VRF Explorer
ON/OFF Explorer software, one PC can perform
Security Company
Headquarters
Temperature setting central control of 10 VRF system sites with Management Center
Suppose you want to find the power consumed by the air Electricity charges (air conditioning)
conditioners of each tenant from the electricity charge
Electric power
company RB Unit Signal transmission line Peak cut operation
for each month. With electricity charge apportionment System Controller A power meter is connected to detect the total power consumption
function, used energy apportionment ratio will be provided,
PPow r
Powe while shifting the indoor unit set temperature, set the indoor unit
calculating in detail the energy consumed by the units used
distribu
ribu
bution
tion Tenant A-1 Tenant A-2 Tenant A-3 forced thermostat off, and taking other measures to carefully control
by each tenant. This information is then used to calculate the boardd
Energy saving graph data: This graph compares the the power consumed while
charges for the electricity consumed for air conditioning by Forced thermostat off range
PPow r
Powe electricity consumption with the previous month and maintaining comfort and Outdoor unit stop range Target power consumption
each tenant from the total electricity charges in the bill from distribu
ibu
bution
tion previous year to make it easy to analyze the energy
Outdoor Tenant A-4 Tenant A-5 Tenant A-6 conducting control to
the electric power company. (See figure at right) boardd saving effect.
unit maintain the target power
The detailed calculation takes into consideration such things
consumption set for each
as unused rooms and nighttime electricity charges and
time. The indoor units to
shows them in a charges calculation sheet. Tenant B-1 Tenant B-2 Tenant B-3 Ideal control line
be controlled can be freely (Use of average
power consumption)
grouped and the control
3Ø, 4 wire 400V, 50Hz level can be set. Shows change in power consumption by time
Tenant C-1 Tenant C-2 Tenant C-3 1Ø, 2wire 230V, 50Hz
Power consumption
charges. summer capacity
Tenant A Tenant B Indoor unit energy used upper limit
Tenant A Tenant B
Apportioned energy Tenant A Tenant B Tenant C
Electric Electric Electric Cold day of
Tenant C Tenant C Indoor unit Bill Bill Bill winter
total energy used Outdoor unit capacity
control screen Time
AIRSTAGE Control Systems Centralized Controller
TM
Set the temperature to start cooling and the temperature to start Custom Auto operation display System
Max. indoor unit / remote controller groups per VRF network
Max. outdoor units per System controller
400
100
400
100
specification
heating, and perform the cooling / heating operation according to Max. indoor units / remote controller groups per System controller
Max. outdoor units per System controller
1600
400
400
100
the room temperature. When the room temperature is between Multi site display 10 10
Number of building / 1 site 20
the cooling set temperature and the heating set temperature, Number of floor per 1 site 200
since air conditioning is not performed, energy saving performance Site
Number of floor per 1 building 50
z
'JUDSKLFDOOD\RXWYLHZ
is improved. supervision
2D graphical layout view z
List display z z
Tree display z z
Group display z z
Cooling set temp. 28ÝC, Heating set temp. 18ÝC Error
Error notification z z
Audible alarm z z
management
Error e-mail notification z z
Error history z z
History Operation history z z
Control history z z
On/Off z z
Custom Auto operation display Operation mode z z
Room temperature z z
Auto Individual
Fan speed z z
Operation Start
Changeover control
Air flow direction
Economy mode
z
z
z
z
Room temperature set point limitation z z
Change over Operation
Antifreeze z z
control
Outdoor unit low noise setting z z
Cooling Set Point Remote control prohibition setting z z
Individual
Temperature upper and lower limit setting z z
Heating Set Point management
Filter sign reset z z
Memory operation z z
Change over Other Pattern operation z z
Web operation z z
Annual Schedule z z
Special day setting z z
Room temperature On /off per day 72 72
Schedule On / off per week 504 504
Day off z z
Min. unit of timer setting (Minutes) 10 10
*This function can display only the indoor unit that supports Custom Auto Function. Low noise mode Weekly schedule z z
Web Operation z z
Remote Remote monitoring z z
managemment Remote operation control z z
Remote function setting z z
Operating & control record Energy saving function Graphic accelerator 0LFURVRIW'LUHFW;FFRPSDWLEOH
Software $GREH5HDGHURUODWHU
Displays the history of operation status Energy saving operation (FKHORQ886%1HWZRUN,QWHUIDFH²73)7&KDQQHO0RGHOQXPEHU55HTXLUHGIRUHDFK95)1HWZRUNUH
and indications. considering comfort by <PACKING LIST>
economy setting, temperature For System controller For System controller Lite
set point limitation, etc.
Type System controller System Controller Lite
Energy manager Remote access Electricity charge apportionment Energy saving Central Control
AIRSTAGE Control Systems Convertor / Adaptor
TM
87<$%*;= 87<9%*;
,WLVSRVVLEOHWRFRQQHFWPHGLXPWRODUJHVL]HG%06WR95)QHWZRUNV\VWHPYLD%$&QHWDJOREDO %$&QHW*DWHZD\HQDEOHVWRFRQQHFWD%06DQG)*95)V\VWHP
standard for open networks. $PD[LPXPRILQGRRUXQLWVDQGUHIULJHUDQWV\VWHPFDQEHFRQQHFWHGWRD
$PD[LPXPRILQGRRUXQLWVZLWK95)QHWZRUNV\VWHPVDPD[LPXPRILQGRRUXQLWV VLQJOH%$&QHW*DWHZD\
BACnet is a registered trademark of ASHRAE. ASHRAE does not
RXWGRRUXQLWVIRURQHQHWZRUNV\VWHPFDQEHFRQQHFWHGWRRQH%$&QHW*DWHZD\ &RPSDWLEOHZLWK%$&QHW$16,$6+5$(DSSOLFDWLRQVSHFLILF endorse, approve or test products for compliance with ASHRAE
standards. Compliance of listed products to the requirements
,WLVSRVVLEOHWRFRQWURORUPRQLWRU95)QHWZRUNV\VWHPIURP%06YLD%$&QHW*DWHZD\ BACnet is a registered trademark of ASHRAE. ASHRAE does not
endorse, approve or test products for compliance with ASHRAE
controller (B-ASC). RI$6+5$(6WDQGDUGLVWKHUHVSRQVLELOLW\RI%$&QHW
International (BI). BTL is a registered trademark of BACnet
&RPSDWLEOHZLWK%$&QHW$16,$6+5$(DSSOLFDWLRQVSHFLILFFRQWUROOHU%$6& standards. Compliance of listed products to the requirements
RI$6+5$(6WDQGDUGLVWKHUHVSRQVLELOLW\RI%$&QHW
&RPSDWLEOHZLWK%$&QHW,3RYHU(WKHUQHW International.
Security system
BACnet® Operator
Workstation (B-OWS) Automatic fire alarm interface
VRF network system 1 BACnet®
®
BACnet BACnet ® Operator
Windows bind VRF Outdoor unit
Lighting facilities Number of controllable indoor units 128 Power Supply 100-240V 50/60Hz, single phase
Number of controllable refrigerant system Power Consumption W 4.6 (max)
VRF network system 2
Number of controllable VRF network 1 Dimensions (H x W x D) mm 59.6 × 270.4 × 176
Security system Number of connectable units / one VRF etwork 4 Weight g 1,200
USB adaptor
(Field supplied)
BACnet® Gateway Automatic fire alarm interface
Indoor unit Outdoor unit (UTY-ABGXZ1)
Security system
HDD 40 GB or more of free space General-purpose
Display 1024 x 768 or higher resolution building control computer Automatic fire alarm interface LONWORKS®
(LONWORKS® device)
(WKHUQHWSRUWIRUJHWWLQJDFFHVVWRWKH,QWHUQHWXVLQJ/$1 Network VRF Outdoor unit
Windows bind
86%SRUWV0D[LPXPRISRUWV
Interface 86%SRUWLVUHTXLUHGIRU:+,7(86%.(<:LEX.H\FRQQHFWLRQ
0D[LPXPRI86%SRUWVDUHUHTXLUHGIRU(FKHORQ886%1HWZRUN,QWHUIDFH
0D[LPXPQXPEHURIUHTXLUHG86%SRUWVGHSHQGVRQWKHDSSOLFDEOHV\VWHPFRQILJXUDWLRQV Specifications Transmission specifications (BMS side)
Software $GREH5HDGHURUODWHU
Model name 87<9/*; Transmission speed 78 kbps
(FKHORQ886%1HWZRUN,QWHUIDFH²73)7&KDQQHO0RGHOQXPEHU55HTXLUHGIRUHDFK95)1HWZRUN
Power Supply 208-240V 50/60Hz, Single phase Transceiver )7;(FKHORQ&RUSRUDWLRQ
<PACKING LIST> Power Consumption W 4.5 Transmission way form Free topology
Name and shape Quantity Application Dimensions (H x W x D) mm 67 × 288 × 211 None
Terminal resistor
WHITE-USB-KEY 1 ,QFOXGHVWKHVRIWZDUHDQGPDQXDOVOLFHQVHIRU%$&QHW*DWHZD\ Weight g 1,500 (It attaches at the terminal of a network.)
140 141
AIRSTAGE Control Systems Convertor / Adaptor
TM
87<90*; 87<9.*;
The MODOBUS Convertor allows a complete integration of air conditioners into MODBUS Networks. It is possible to control the VRF system from central / home controller via KNX network.
&RPSDFWDQGOLJKWZHLJKWGHVLJQ 1HZ.1;&RQYHUWRUHQDEOHVWRFRQQHFWFHQWUDOKRPHFRQWUROOHUDQG)*95)V\VWHP
'LUHFWFRQQHFWLRQWR02'%861HWZRUN $PD[LPXPRILQGRRUXQLWVDQGRXWGRRUXQLWVFDQEHFRQQHFWHGWRVLQJOH.1;&RQYHUWRU
8SWRLQGRRUXQLWVFDQEHFRQWUROOHGLQRQH02'%86&RQYHUWRU
7KH02'%86&RQYHUWRUSHUPLWVFHQWUDOPRQLWRULQJDQGFRQWURORIDLUFRQGLWLRQHUVIURP%06RU&HQWUDO&RQWUROOHU
Functions Functions
Controller
MODBUS Convertor
BMS/Central Lighting facilities
for VRF VRF Indoor unit VRF Indoor unit
Controller Security system
Central / Home
Automatic fire alarm interface VRF Outdoor unit Registrable
Controller
Windows bind
128 indoor units
* BMS : Bulding Management System 100 outdoor units
Specifications Specifications
Model name 87<90*; Model name 87<9.*;
Power Supply 220-240V 50/60Hz Power Supply 220-240V 50/60Hz
Input power W Max. 2 Input power W 1.5
Dimensions (H x W x D) mm 54 × 260 × 150 Dimensions (H x W x D) mm 54 × 260 × 150
Weight g 1,100 Weight g 1,200
1 1
Single indoor unit group
)-5&0%6 )-5&.1;L
The Modbus Interface allows a complete integration of The KNX Interface allows a complete integration of air
air conditioners into Modbus Networks. conditioners with KNX Network systems.
6LPSOHLQVWDOODWLRQGXHWRVPDOODQGFRPSDFWVL]H 6LPSOHLQVWDOODWLRQGXHWRVPDOODQGFRPSDFWVL]H
1RVHSDUDWHH[WHUQDOSRZHUVXSSO\UHTXLUHG 1RVHSDUDWHH[WHUQDOSRZHUVXSSO\UHTXLUHGMXVW.1;EXVSRZHU
7KH0RGEXV,QWHUIDFHSHUPLWVFHQWUDOPRQLWRULQJDQGFRQWURORIDLUFRQGLWLRQHUVIURP%06 &DQEHXVHGIRUVLQJOHLQGRRUXQLWVDQGJURXSFRQWUROOHGXSWRLQGRRUXQLWV
Functions Functions
Max. 63
Modbus Network KNX Network
Modbus Interface The Modbus Interface can be used with
The KNX Interface can be used with or
or without Wired Remote Controller.
without Wired Remote Controller.
BMS/Central Home Controller
Specifications Specifications
Model name )-5&0%6 Model name )-5&.1;L
142
AIRSTAGE Control Systems Convertor / Adaptor
TM
1 1
Single indoor unit Single indoor unit
87<7)6;= )-5&:,),
,WLVWKHPRVWDGYDQFHGVROXWLRQWRUHPRWHO\PDQDJHDQ$LU&RQGLWLRQLQJV\VWHPXVLQJ ,WLVWKHPRVWDGYDQFHGVROXWLRQWRUHPRWHO\PDQDJHDQ$LU&RQGLWLRQLQJV\VWHPXVLQJ
all sort of mobile devices such as Smartphones, and tablets. all sort of mobile devices such as Smartphones, Tablets and PC
1RVHSDUDWHH[WHUQDOSRZHUVXSSO\UHTXLUHG 1RVHSDUDWHH[WHUQDOSRZHUVXSSO\UHTXLUHG
&DQEHXVHGIRUVLQJOHLQGRRUXQLWVDQGPXOWLV\VWHPLQGRRUXQLWV &DQEHXVHGIRUVLQJOHLQGRRUXQLWVDQGJURXSFRQWUROOHGXSWRLQGRRUXQLWV
Functions Functions
Download Free
Indoor unit
Internet Smartphone
Wireless LAN
Interface
Wireless LAN
Internet
Indoor unit Interface Tablet
Tablet
Router
(Field supplied)
PC
Router
Smartphone (Locally purchased)
Smartphone
Indoor unit
Internet
Advanced control (Optional functions) Notifications and History
Router
(Locally purchased) &OLPDWHZRUNLQJPRGHV(&2&RPIRUW3RZHUIXOIXWXUHUHOHDVH $OHUWVHPDLOQRWLILFDWLRQIXWXUHUHOHDVH
6FKHGXODEOHIXQFWLRQDOLWLHV212))0RGHV6HWSRLQWWHPSHUDWXUH $LUFRQGLWLRQLQJPDOIXQFWLRQDOHUWV
Indoor unit
Fan Speed, Louver position) &RQQHFWLYLW\PRQLWRULQJDQGDOHUWV
Multiple air conditioning management 6HWWHPSHUDWXUHOLPLWDWLRQIXWXUHUHOHDVH +LVWRU\IXWXUHUHOHDVH
0XOWLSOH6FHQHV 7LPHUVDQG&DOHQGDUIXQFWLRQ
Outdoor unit Smartphone 0XOWLSOHDLUFRQGLWLRQLQJPDQDJHPHQWDWGLIIHUHQFHORFDWLRQV
Specifications Specifications
Model name 87<7)6;= Model name )-5&:,),
Dimensions (H x W x D) mm îî Dimensions (H x W x D) mm 108 × 70 × 28
Weight g Weight g 80
144 145
AIRSTAGE Control Systems Convertor / Adaptor
TM
16 100 1
single indoor units Network Convertors group
UTY-VTGX
DC power supply type
UTY-VTGXV
AC power supply type Installation example
Human sensor catches movements of
Functions people in a room, and operates with lower
capacity when people come back to the
SAVE ! AUTO RESTART
room, it automatically returns to previous +2°C *Max. 30°C
Installation example operation mode.
Cooling/Dry
Set temp. Human sensor equipment needs to be
purchased locally. The above example
W\SHVRIUHPRWHFRQWUROOHUW\SHDQGUHPRWHFRQWUROOHUVW\SHDUHDYDLODEOH Heating indicated that a signal is sent to this
3RZHUVXSSO\$&9+]LVUHTXLUHGIRUUHPRWHFRQWUROOHUVW\SH External Switch Controller if human
Set temp. -4°C *Max. 16°C
sensor does not detect for 20 minutes.
Human sensor is not mounted on the
Normal operation Saving operation Normal operation External Switch Controller.
VRF network System
Specifications
Model name 87<7(5;
Network Convertors Network Convertors Power Supply DC 6.5-16V
(for 1 remote controller) (for 2 remote controllers) Dimensions (H x W x D) mm îî
Weight g 250
AC230V
DC12V is supplied by indoor unit.
Signal Amplifier
87<96*;=
ZLUHDQGZLUHW\SHRIWKHZLUHGUHPRWHFRQWUROOHUFDQEH $FHQWUDOFRQWUROFDQEHSURYLGHGIRUWKHVLQJOHVSOLWV\VWHPV8SWR 7UDQVPLVVLRQ/LQHOHQJWKFDQEHH[WHQGHGXSWRPZLWKPXOWLSOH6LJQDO$PSOLILHUV
connectable. 100 units of Network Convertor is connectable in one VRF network 8SWRVLJQDODPSOLILHUVFDQEHLQVWDOOHGLQD95)QHWZRUNV\VWHP
3RZHUVXSSO\$&9+]LVUHTXLUHGIRUUHPRWH system) $VLJQDODPSOLILHULVUHTXLUHG
controllers type. (1) When the total wiring length of the transmission line exceeds 500m.
(2) When the total number of units on the transmission line exceeds 64.
VRF network System VRF network System
Functions
Up to 100 units of
Network Converter
Installation example
B
C
A D
Signal Amplifier
Specifications Specifications
Model name 87<97*; 87<97*;9 Model name 87<96*;=
Power Supply SRODUZLUH'&9 non-polar 2-wire DC12V 220-240V 50/60Hz, Single phase Power Supply 208-240V 50/60Hz, Single phase
Input power W Max. 1.2 0D[ Input power W 4.5
Dimensions (H x W x D) mm îî 54 × 260 × 150 Dimensions (H x W x D) mm 67 × 288 × 211
Weight g 250 1,100 Weight g 1,500
146 147
EFFECTIVE HEAT EXCHANGE AND
SIMULTANEOUS FRESH AIR VENTILATION
High Efficiency and low noise levels are achieved by using a highly efficient heat
selecting whether to use heat exchange or normal ventilation setting, according to the
VENTILATION
Energy Recovery Ventilator
DX-Kit for airhandling applications
148 149
Ventilation
Specifications
Rated flow rate 250 m3/h 350 m3/h 500 m3/h 800 m3/h 1000 m3/h
Feature Model name UTZ-BD025C UTZ-BD035C UTZ-BD050C UTZ-BD080C UTZ-BD100C
3RZHUVRXUFH 220 - 240V, 50Hz
Input power Extra high / High / Low W 128 / 123 / 96 190 / 185 / 168 289 / 225 / 185 418 / 378 / 295 464 / 432 / 311
Heat exchange ventilation and normal ventilation Air flow rate Extra high / High / Low m3/h 250 / 250 / 190 350 / 350 / 240 500 / 500 / 440 800 / 800 / 630 1000 / 1000 / 700
HEAT EXCHANGE
External static pressure Extra high / High / Low 3D 105 / 95 / 45 140 / 60 / 45 120 / 60 / 35 140 / 110 / 55 105 / 80 / 75
VENTILATION
Heat exchange ventilation Adopts a highly efficient counter-flow
Temperature Exchange
When a room is cooled or heated, the exhausted cooling / heating heat exchange element Efficiency
Extra high / High / Low % 75 / 75 / 77 75 / 75 / 78 75 / 75 / 76 75 / 75 / 76 75 / 75 / 79
energy is recovered by heat-exchange ventilation. Heat exchanger Energy Exchange
Outside air Extra high / High / Low % 63 / 63 / 65 66 / 66 / 71 62 / 62 / 64 65 / 65 / 68 65 / 65 / 70
Exhaust air Efficiency Cooling
Normal ventilation Energy Exchange
Extra high / High / Low % 70 / 70 / 72 69 / 69 / 73 67 / 67 / 69 71 / 71 / 74 71 / 71 / 76
Efficiency Heating
The operation is used during periods when the room space requires
Sound pressure level Extra high / High / Low dB* 31.5 / 30.5 / 26.5 33.0 / 31.0 / 25.5 37.5 / 35.5 / 32.5 37.5 / 37.0 / 34.5 38.5 / 37.5 / 34.5
no cooling or heating effect, i.e. when there is minimal temperature
Input power Extra high / High / Low W 128 / 123 / 96 190 / 185 / 168 289 / 225 / 185 418 / 378 / 295 464 / 432 / 311
VENTILATION
difference between the indoor and outdoor environments.
NORMAL
Supply air Air flow rate Extra high / High / Low m3/h 250 / 250 / 190 350 / 350 / 240 500 / 500 / 440 800 / 800 / 630 1000 / 1000 / 700
Room air
External static pressure Extra high / High / Low 3D 105 / 95 / 45 140 / 60 / 45 120 / 60 / 35 140 / 110 / 55 105 / 80 / 75
Sound pressure level Extra high / High / Low dB* 31.5 / 30.5 / 26.5 33.0 / 31.0 / 25.5 38.5 / 38.0 / 32.5 37.5 / 37.0 / 34.5 40.5 / 39.5 / 36.5
Dimensions (W × D × H) mm 882 × 599 × 270 1050 × 804 × 317 1090 × 904 × 317 1322 × 884 × 388 1322 × 1134 × 388
Weight kg 29 49 57 71 83
Outlet duct diameter mm 150 150 200 250 250
Energy efficiency and ecology Reverse mountable direct air supply / Operation range °C -10 to 40 -10 to 40 -10 to 40 -10 to 40 -10 to 40
Features of heat exchange element Since each unit can be mounted in reverse position, only one
Dimensions (Unit: mm)
inspection hole is needed for two units:
With the cross-flow element, air moves in a straight line across the
element. With the counter-flow element , air flows through the Two units can share one inspection hole so duct work is easier and
element for a longer time (longer distance) ,so the heat-exchange more flexible.
effect remains unchanged.
150 151
Ventilation
EEV unit
UTP-VX30A Control unit
UTY-VDGX
UTP-VX60A
Installation Limitation
UTP-VX90A
the air handling unit and fan coil unit. [For 2EEV units connection (option)]
Arrangement as part of a VRF system 6HSDUDWLRQ7XEH873/;$ 50%–RIRXWGRRUXQLWFDSDFLW\
AHU Thermistor
Transmission line
When connecting to an air handling unit, Indoor
Piping and wiring length
unit
the supply air temperature is controlled
DX-Kit by the discharge sensor. Air Handling Unit
((9XQLW
VRF system
0D[SLSLQJOHQJWKP &RQWUROXQLW
0D[ZLULQJOHQJWKP
Air Handling
FCU Unit
When connecting to a fan coil unit, the Control unit 0D[ZLULQJOHQJWKP
room temperature is controlled by the EEV unit
return air temperature sensor. DX-Kit
DX-Kit Thermistor Wired R.C.
Thermistor
Specifications
EEV unit UTP-VX30A UTP-VX60A UTP-VX90A UTP-VX90A×2
Supports a wide range of capacity classes A variety of controls to match the application 3RZHUVRXUFH V/Ø/Hz 230/1/50
Connectable capacity class kW 5.0 6.3 8.0 10.0 12.5 14.0 20.0 25.0 40.0 50.0
((9XQLWVFDQEHFRQQHFWHGLQSDUDOOHODQGXSWR+3N: &HQWUDOFRQWUROXVLQJRXU95)FRQWUROOHUVRUFHQWUDOPDQDJHPHQW 5.6 6.3 8 10 12.5 14 22.4 25 40 50.4
Cooling
ODUJHFDSDFLW\XQLWV6HSDUDWLRQ7XEHRI873/;$LVUHTXLUHG controllers (5.1-5.9) (6.0-7.1) (7.2-9.0) (9.1-11.1) (11.2-13.2) (13.3-18.0) (18.1-23.7) (23.8-28.0) (28.1-44.7) (44.8-50.4)
Capacity kW
&RQQHFWDEOHFDSDFLW\UDQJHN:WRN: Heating
6.3 7.1 9 11.2 14 16 25 28 45 56.5
(5.7-6.7) (6.8-8.0) (8.1-10.0) (10.1-12.4) (12.5-15.0) (15.1-20.0) (20.1-26.5) (26.6-31.5) (31.6-49.9) (50.0-56.5)
EEV unit Transmission line Airflow Rate(Reference value) m3/h 1,060 1,200 1,520 1,600 2,000 2,240 3,560 4,000 6,400 8,000
External I/O
Dimensions (H × W × D) mm 160 × 220 × 90 (160 × 220 × 90)× 2
Interface Thermistor Weight kg 2 2×2
Piping (Option)
EEV unit DX-Kit Connection
AHU or FCU AHU or FCU Liquid mm 9.52 9.52 9.52 9.52 9.52 9.52 12.70 12.70 12.70 12.70
(40 – 50 kW class) pipe diameter
VRF Controller Modbus network
152 153
Auto Louver Grille Kit
Models
UTD-GXTA-W
UTD-GXTB-W
UTD-GXTC-W
)HDWXUH
AIRSTAGE
TM
2SHUDWLRQZLWKLQGRRUXQLW W2
Fitting Flame
Auto Louver can be operated by synchronizing remote controller of
indoor unit. Grille
83DQG'RZQDXWRVZLQJ
OPTION
$XWRDLUIORZGLUHFWLRQDQGDXWRVZLQJ
VWHSVVHOHFWDEOH H1 H2
$XWRFORVLQJORXYHU
W1 D1 D2
:KHQRSHUDWLRQRILQGRRUXQLWLVVWRSSHGWKHORXYHUZLOO
automatically close.
Unit: mm
6SHFLILFDWLRQV
Model name UTD-GXTA-W UTD-GXTB-W UTD-GXTC-W
ARXD04/07/09/12/14GALH ARXD18GALH ARXD24GALH
Applicable Indoor Unit
ARXK04/07/09/12/14GCLH ARXK18GCLH ARXK24GCLH
3RZHUVRXUFH &RQQHFWLQJZLWK&RQWUROER[RILQGRRUXQLW
)L[LQJRI$XWR/RXYHU*ULOOH 6FUHZÀ[LQJWR)ODQJHRU6TXDUH'XFW
([WHQVLRQ6TXDUH'XFW/LPLW P0D[GXFWOHQJWKEHWZHHQLQGRRUXQLWDQG*ULOOH
'LPHQVLRQV+î:î' mm îî îî îî
Net 2.0 2.5
Weight kg
Gross 4.0
Color White
Louver Motor Stepping Motor
Accessories Fitting Flame, etc.
°C WR
Operation Cooling
5+ 80% or less
Range
+HDWLQJ °C WR
7KH$XWR/RXYHU*ULOOH.LWFDQDOVREHLQVWDOOHGWR$5;'/$7+UHYLVLRQFRGH%PRGHOV3OHDVHUHIHUWRWKH'HVLJQ 7HFKQLFDOPDQXDOIRUµUHYLVLRQFRGH´GHWDLOV
154 155
AIRSTAGE 2SWLRQ TM
&RQWUROOHUV,QWHUIDFH Others
,QGRRUXQLW ,QGRRUXQLW
&DVVHWWH 'XFW Floor :DOO0RXQWHG &DVVHWWH 'XFW Floor :DOO0RXQWHG
Compact Mini Slim Medium &HLOLQJ Compact Mini Slim Medium &HLOLQJ
EEV Ceiling EEV EEV EEV Ceiling EEV EEV
*ULG ZD\ &LUFXODU)ORZ (With drain (With drain Static +LJK6WDWLF3UHVVXUH - Floor - - - *ULG ZD\ &LUFXODU)ORZ (With drain (With drain Static +LJK6WDWLF3UHVVXUH - Floor - - -
H[WHUQDO H[WHUQDO H[WHUQDO H[WHUQDO H[WHUQDO H[WHUQDO
6WDQGDUG SXPS SXPS Pressure 6WDQGDUG SXPS SXPS Pressure
Type Type
$8;% $8;%
AUXK AUXK
*%/+ AUXA ARXK $5;' $5;& $5;& AGYA AGYE ASYA ASYE *%/+ AUXA ARXK $5;' $5;& $5;& AGYA AGYE ASYA ASYE
$8;' AUXM ARXA $%<$ $%<$ ASYA ASYE ASYA ASYA $8;' AUXM ARXA $%<$ $%<$ ASYA ASYE ASYA ASYA
$8;% *%7+ *%7+ $8;% *%7+ *%7+
$5;& $5;& $5;& $5;&
*$/+ */$+ *%/+ *$7+ *$7+ *&$+ *&$+ *%&+ *7$+ *$/+ */$+ *%/+ *$7+ *$7+ *&$+ *&$+ *%&+ *7$+
*$/+ *&/+ *$/+ *$7+ *$7+ *&$+ *&$+ *7$+ *7$+ *$/+ *&/+ *$/+ *$7+ *$7+ *&$+ *&$+ *7$+ *7$+
*/$+ */$+
*$/+ *$/+
Controllers
2WKHUV
+XPDQ
UTY-RNRYZ2 Sensor Kit 87<6+=;&
Wired
Remote
Controller
Remote
UTY-RLRY Sensor
Unit
1HZDPHQLW\VSDFHFDQEH UTY-XSZX
offered by installing the
Remote sensor.
Simple
Remote
Controller 87<565<87<5+5<87<56.<87<5+.<
ZLUHW\SH ZLUHW\SH
Wireless UTG-UFYE-W
Remote
Controller 87</1+<
UTG-UFYC-W UTG-
Group
Cassette UFYE-W
Remote UTG-UKYC-W
87<&**<87<9**;= Grille UTG-
Controller 87*8.<$%
UFYC-W
Central UTG-UKYC-W
Remote
Controller 87<'&*<
Touch 87*8.<$%
Panel
Controller 87<'7*<=
System Auto
Controller, Louver 87'*;7$:
Grille Kit 87'*;7%:
System
Controller UTY-APGXZ1, UTY-ALGXZ1 87'*;7&:
Lite
Long Life
IR Receiver 87' 87'
Filter
Unit 87</5+<% 87</%+;' 87%<:& LF25NA /).$
,QWHUIDFH
%$&QHW 87'
*DWHZD\ Flange SF045T 87'
87<$%*;=87<9%*;
87' RF204
RF204
1HWZRUN
Convertor 'UDLQ
for UTY-VLGX Pump UTZ- UTR-
LONWORKS Unit 3;1%$ '3%7
02'%86
Interface FJ-RC- (mm)
)-5&0%6 )-5&0%6 )-5&0%6
0%6 Panel 242
Spacer 87*%.;$:
87*%.;$:
87*%*<$:
Panel spacer
KNX
Convertor UTY-VKGX
Fresh Air
Intake Kit UTZ-
For Compact For Cassette UTZ-VXRA UTZ-VXRA
Cassette
VXAA
KNX
Interface FJ-RC-
FJ-RC-KNX-1i FJ-RC-KNX-1i FJ-RC-KNX-1i
KNX-1i
Air Outlet For Compact Cassette
Shutter UTR-
Plate 875<'=. 875<'=.
<'=%
UTY- For Cassette
UTY-TFSXZ1 UTY-TFSXZ1 UTY-TFSXZ1
Wireless TFSXZ1
LAN Insulation
Interface IRU+LJK UTZ- UTZ- UTZ-
+XPLGLW\ UTZ-KXRA
FJ-RC- )RU&RPSDFW&DVVHWWHW\SH KXGC KXRA KXRA
FJ-RC-WIFI-1 FJ-RC-WIFI-1 FJ-RC-WIFI-1 Cassette type
WIFI-1
+DOI
([WHUQDO
Concealed This kit is used to half
6ZLWFK UTR-STA
UTY-TERX Kit conceal floor type indoor
Controller
XQLWLQWRWKHZDOO
AIRSTAGE 2SWLRQ TM
OPTIONAL PARTS
Controllers &RQYHUWRUV$GDSWRUV
UTY-PTGXA
UTY-PLGXR2 UTY-PEGXZ1
UTY-PLGXA2
UTY-PLGXE2
UTY-PLGXX2
158
AIRSTAGE 2SWLRQ TM
OPTIONAL PARTS
3DQHOV 2WKHUV
&DVVHWWH*ULOOH &DVVHWWH*ULOOH
/RQJ/LIH)LOWHU $XWR/RXYHU*ULOOH.LW 'UDLQ3XPS8QLW
UTG-UKYC-W 87*8.<$%
87'/)1$ 87'/).$ 87'*;7$: IRU$5;'$5;. 87=3;%%$
)RU&LUFXODU)ORZ&DVVHWWHW\SH 87'*;7%: IRU$5;'$5;.
)RU&LUFXODU)ORZ&DVVHWWHW\SH )RU0HGLXP6WDWLF )RU+LJK6WDWLF )RU/RZ6WDWLF3UHVVXUH'XFWW\SH
3UHVVXUH'XFWW\SH 3UHVVXUH'XFWW\SH 87'*;7&: IRU$5;'$5;.
)RU6OLP'XFWW\SH0LQL'XFWW\SH 87=3;1%$
)RU0HGLXP6WDWLF3UHVVXUH'XFW
2WKHUV
Panel 600 50
600 (mm) Panel spacer UTY-XWZXZC UTY-XWZXZF
87<;:=;=% UTY-XWZXZ8
* Not applicable for VRF V-II tropical and V-III tropical series
UTY-XWZXZA
AIRSTAGE 2SWLRQ TM
FUNCTION LIST
([WHUQDO,QSXWDQG2XWSXW)XQFWLRQ([WHUQDO&RQQHFW.LW&RPPXQLFDWLRQ.LW
,QGRRUXQLW ,QGRRUXQLW 2XWGRRUXQLW Controller 2WKHU
&DVVHWWH 'XFW Floor :DOO0RXQWHG
&RPSDFW Mini Slim V-III &HQWUDO5HPRWH 7RXFK3DQHO
+LJK6WDWLF EEV )ORRU&HLOOLQJ EEV J-IIIL J-III J-IIS V-III VR-II RB Unit
*ULGW\SH ZD\ &LUFXODU)ORZ :LWKGUDLQ :LWKGUDLQ 0HGLXP6WDWLF Ƥ Ƥ Ƥ 7URSLFDO Controller Controller
3UHVVXUH 3UHVVXUH H[WHUQDO H[WHUQDO
6WDQGDUGW\SH SXPS SXPS
Type ARXC
AUXM
$8;% $8;' *%7+ AJY
ASYA ASYE
*%/+ *$/+ ARXK $5;' ARXC AGYA AGYE AJG AJY AJY AJYA 8735;$+
*/$+ ARXA $%<$ $%<$ AJY
$8;% AUXA *$7+ ASYA ASYA /%/$+ 8735;%+
AUXK *7$+ *7$+ 87<'&*< 87<'7*<=
ARXC *%&+ *7$+ AJY 8735;&+
*%/+ *$7+ *$7+ ASYA ASYE /(/$+
/&/$+
/1/%+ /$/%+ *$/+ 8735;%+
*&/+ *$/+ *%7+ *&$+ *&$+
*&$+ *&$+
*$/+ *$/+ ARXC /(/$+
*/$+
*$7+
,QSXW
z87<;:=;=' z87<;:=;='
2SHUDWLRQ6WRS
{87<;:=;=% {87<;:=;=%
z87<;:=;= z*2
$OO2Q$OO2II
{UTY-XWZXZ8 {*2
%DWFK6WRS z87<;:=;=
z87<;:=;=' z87<;:=;='
Forced Stop
{87<;:=;=% {87<;:=;=%
Forced
zUTY-XWZXZE zUTY-XWZXZE
Thermostat
{87<;:=;= {87<;:=;=
off
/RZ1RLVH0RGH2SHUDWLRQ z87<;:=;=
&RROLQJ z87<;:=;=
z87<;:=;=
+HDWLQJ3ULRULW\ {87<;:=;=%
3RZHU8VDJH,QIRUPDWLRQ
z*2
from zUTY-XWZXZF
{*2
Electricity Meter
2XWSXW
$X[LOLDU\+HDWHU2XWSXW zUTY-XWZXZC
*2: Touch Panel Controller has these functions for Dry contact and Apply voltage, however, above External Connect Kit is not necessary 'U\&RQWDFW : Apply Voltage
because Touch Panel Controller has an external input terminal block.
AIRSTAGE 2SWLRQ TM
&RQQHFWLRQ8QLWV 6SHFLILFDWLRQV
+HDGHU
%UDQFKHV 875+/ 875+/
873%;$ 873%;$ 873%;$ UTP-LX180A IRU';.LW Model name
%UDQFKHV UTR-H0908L UTR-H1808L
Suction Suction Suction
Gas Pipe Gas Pipe Gas Pipe Total cooling capacity of indoor unit kW 28.0 or less WR
+HDGHU 2XWGRRUXQLW%UDQFKNLW
Model name 873&;$IRU9,,,9,,,7URSLFDO 873';$IRU95,,
875+/875+/ 875+/875+/ 873-$873-$ 873-$873-$
2 outdoor units 1
Suction Suction
Model name
Gas Pipe Gas Pipe
Gas Pipe Gas Pipe RXWGRRUXQLWV 2
'LVFKDUJH 'LVFKDUJH
Gas Pipe Gas Pipe
EV Kit
/LTXLG3LSH /LTXLG3LSH
/LTXLG3LSH /LTXLG3LSH Model name UTR-EV09XB UTR-EV14XB
$6<(*7$+ $*<(*&$+
$6<(*&$+ $*<(*&$+
Application Model $6<(*7$+ $*<(*&$+
$6<(*&$+ $*<(*&$+
$6<(*7$+ $*<(*&$+
2XWGRRU8QLW%UDQFK.LW
873&;$ 873';$
5%8QLW
Suction Gas Pipe
Gas Pipe Model name 6LQJOHW\SH 0XOWLW\SH
,QSXWSRZHU W 24
/LTXLG3LSH
/LTXLG3LSH
Number of branches 1 1 1 4
0D[LPXPFDSDFLW\RIFRQQHFWDEOH
kW Q 8.0 Q 18.0 Q 28.0 Q
1
LQGRRUXQLWV4
EV Kit 5%8QLW 0D[LPXPFDSDFLW\RIFRQQHFWDEOH
kW Q 8.0 Q 18.0 Q 28.0 Q 18.0
LQGRRUXQLWVSHUEUDQFK4
Model code 875(9;% Model code 875(9;% 8735;$+8735;%+ 8735;%+ 0D[LPXPQXPEHURIFRQQHFWDEOH
8 8 8
indoor units per branch
Model code 875(9;% Model code 875(9;% 8735;&+ 0XOWLW\SH
'LPHQVLRQV+î:î' mm îî îî îî îî
)RU&RPSDFW:DOO0RXQWHGW\SH )RU&RPSDFW)ORRUW\SH 6LQJOHW\SH
,QFDVHRIWZR5%XQLWVFRQQHFWHGLQVHULHVWRWDOEUDQFKHVPD[LPXPFDSDFLW\RIFRQQHFWDEOHLQGRRUXQLWVLVXSWRN:
SUPPORT
Our know-how supports you not only during the
product release but also from guiding implementation
to product maintenance.
AIRSTAGE™ SUPPORT
AIRSTAGE™ / RAC SUPPORT TOOL
QUICK SERVICE & MAINTENANCE
SERVICE TOOL
WEB MONITORING TOOL
Product news
Brochures
Operating Manual
Certificate Data
2D CAD Data
Installation Manual
Service Manual
CFD Simulation
Mobile Technician
Product Training
Model Selection
Design
Verification
Installation
166 167
Support
AIRSTAGE™ SUPPORT
Fujitsu General provides a variety of product and technical information to engineers and consultants, and
also conducts new product research and design support activities.
We provide a wide range of support to maintain high quality from design to installation.
Product information
New product information is provided in the form of documents and
movies for every new model released. These can be downloaded from
a private section of our website. To access this website, please contact
your Fujitsu representative.
Features
Head Office Training Center: Japan
3URGXFW1HZV
%URFKXUHV $OO0DQXDOV
)HDWXUH3URPRWLRQ0RYLH
Technical support
Technical support is provided at every stage from design
Europe Training Center: Germany Europe Training Center: U.K. to installation to assist in providing the most suitable air
conditioning solution.
Features
&)'6LPXODWLRQ
*XLGHOLQH
52.000
&RPPLVVLRQLQJ6XSSRUW
47,750
43.500
39.250
China Training Center: China Asia Training Center: Singapore CFD Simulation
35.000
America Training Center: U.S.A. Middle East Training Center: UAE Oceania Training Center: Australia
Commissioning Support
168 169
Support
Installation limitation
The equipment installation limitation range is shown.
Installation requirements, such as distance from the wall, is
automatically displayed to make it easy to produce highly
reliable layout designs.
Output the format that
matches the application
The information specific to your project can be exported in a
number of industry standard file formats.
170 171
Support
Mobile troubleshooting tool for iPhone & Android Easy maintenance & monitoring
2SHUDWLRQPRGHVWDWXV
'LVFKDUJHWHPSHUDWXUH3UHVVXUHVWDWXV Wired Remote Controller (Touch panel) Wired Remote Controller
&RPSUHVVRURSHUDWLRQLQGLFDWLRQ Error status/Error history
System number
$GGUHVV7\SH1XPEHURIRXWGRRUXQLW 001: Controller
002: Indoor unit Error code
(UURUFRGH
Unit number
Transmission line
We will release an App of troubleshooting tool for iPhone, iPod touch 2SHUDWLRQVWDWXVFRQWURO
and other Apple products. This application is a troubleshooting tool 0RQLWRULQJRSHUDWLQJFRQGLWLRQ
for Fujitsu General air conditioner (RAC/PAC, VRF) 0RQLWRULQJVHQVRUGDWD
,QGLFDWLRQRIWUHQGJUDSK
It helps you to check air conditioner condition. Error code check, (UURUKLVWRU\ Indoor unit
Troubleshooting, and Sensor check are available. ,QGLFDWLRQRIUHIULJHUDQWFLUFXLWGLDJUDP (Locally purchased)
$XWRPDWLFRSHUDWLRQFKHFNIRUUHIULJHUDWLRQF\FOH Service Tool
USB adaptor UTY-ASGXZ1
(Locally purchased) Software
Remote monitoring
VRF system operating status and trouble status details can be
Remote Monitoring
constantly and remotely monitored over the Internet, etc.
Internet Web
Rapid cooperation with the service personnel are also possible. or Monitoring
Public Telephone Tool
Line UTY-AMGXZ1
Software
172 173
Support
UTY-ASGXZ1
Functions
Function summary
VRF System
UTY-ASGXZ1
Service Tool Interchangeability of equipment
(UTY-ASGXZ1)
Monitoring Side Indication of equipment list
Operation control
Indication of refrigerant circuit diagram
Internet Commissioning tool
Storage and CSV output of operating history (sensor data)
: Transmission line Indication of trend graph
: Refrigerant piping USB adaptor Printing of trend graph
(Locally purchased) Monitoring and screen display of abnormalities
E-mail automatic transmission of abnormalities -
Network Topology Analyzer
Remote Setting
Automatic operation check for refrigeration cycle System Time Setting
Central Release
After product installation, operation check can be performed automatically. Self-diagnosis function automatically judges whether each sensor Model Name Writer
value is normal, so the operation check work can be reduced. The diagnosis can also be output as a report. Error Memory Reader
Time Guard Information
Automatic operation check for refrigeration cycle
Whether each sensor value is normal is Many different kinds of graph display
judged automatically. Automatic update of software
Custom Auto function
Discharge temperature normal value OK Display of individual louver control function
Super heat volume normal value OK Display of human sensor control function
High pressure pipe normal value OK Refrigerant leakage detect function (Europe only)
distant place. When visiting for troubleshooting on site, operation However, multiple graphs can be displayed in new Service Tool CPU 1 GHz or higher
status can be shared in real time and get assistance easily. Online depending on the situation. The refrigeration cycle can be checked in Memory
*%RUPRUHIRU:LQGRZV>ELW@:LQGRZV>ELW@DQG:LQGRZV>ELW@
*%RUPRUHIRU:LQGRZV>ELW@:LQGRZV>ELW@DQG:LQGRZV>ELW@
chat function helps to support on site staff. detail.
HDD 40 GB or more of free space
Display 1366 x 768 or higher resolution
An error occurs at local system.
Interface 86%SRUWIRU886%1HWZRUN,QWHUIDFHDQG6RIWZDUHSURWHFWLRQNH\
Distant place
ERROR Software Internet Explorer® 11 or Microsoft Edge
(FKHORQ886%1HWZRUN,QWHUIDFH²73)7&KDQQHO0RGHOQXPEHU55HTXLUHGIRUHDFK95)1HWZRUN
<PACKING LIST>
Internet
Name and shape Quantity Application
:+,7(86%.(< Software protection key to be connected to USB port on the Service Tool-installed PC.
1
Technical support Installer / Administrator (Software protection key) These products run only on a PC with WibuKey.
3HUVRQDOFRPSXWHUWKDWVDWLVILHVWKHIROORZLQJV\VWHPUHTXLUHPHQWV
174 175
Support
WEB MONITORING TOOL Custom Auto Function Refrigerant leakage detect Function
UTY-AMGXZ1
Product features
7URXEOHVKRRWLQJLVSHUIRUPHGE\PRQLWRULQJHDFKDLUFRQGLWLRQLQJXQLWUHPRWHO\GXULQJSHULRGLFDOV\VWHPFKHFNV
(UURUQRWLILFDWLRQFDQEHDXWRPDWLFDOO\WUDQVPLWWHGWRVHYHUDOORFDWLRQVXVLQJWKHLQWHUQHW
1.
5HTXLUHVHLWKHUDGHGLFDWHGLQWHUQHWFRQQHFWLRQRUSXEOLFWHOHSKRQHOLQH
'HWHUPLQDWLRQRIDQHUURURFFXUUHQFHFDQEHPDGHWKURXJKHUURUZDUQLQJVDQGHTXLSPHQWVWDWXVLQIRUPDWLRQREWDLQHGIURPDUHPRWHORFDWLRQ
7KHPRQLWRULQJGDWDLQDUHPRWHVLGHFDQEHRSWLRQDOO\GRZQORDGHG$QGWKLVGDWDFDQEHGLVSOD\HGLQRIIOLQHPRGHRIWKHVHUYLFHWRRO Custom Auto operation display
0RQLWRULQJVLGHFRPSXWHULVQRWUHTXLUHGWRLQVWDOOVSHFLDOVRIWZDUHUHTXLUHVRQO\JHQHUDOZHEEURZVHU
Refrigerant leak alart display
8VHRILQWHUQHWPDLOV\VWHPUHTXLUHG
Functions
176 177
http://www.fujitsu-general.com/
6SHFLILFDWLRQVDQGGHVLJQDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFHIRUIXWXUHLPSURYHPHQW
)RUIXUWKHUGHWDLOVSOHDVHFKHFNZLWKRXUDXWKRULVHGGHDOHU
&RROLQJ+HDWLQJFDSDFLWLHVDUHEDVHGRQWKHIROORZLQJFRQGLWLRQV
,QGRRUWHPS&'%&:% ,QGRRUWHPS&:%
&RROLQJ 2XWGRRUWHPS&'%&:% +HDWLQJ
2XWGRRUWHPS&'%&:%
3HUIRUPDQFHWHVWLVLQDFFRUGDQFHZLWK(1
6HDVRQDOHIILFLHQF\WHVWLVRQDFFRUGDQFHZLWK(1
6RXQGSRZHUWHVWLVLQDFFRUGDQFHZLWK(1
SATISFACTION
Fujitsu General (Thailand) Co., Ltd.
FOR
Fujitsu General (Shanghai) Co., Ltd.
ALL CUSTOMERS
01 100 79269 CNBJ312244-UK
6SHFLILFDWLRQVDQGGHVLJQDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFHIRUIXWXUHLPSURYHPHQW
7KHSURGXFWVRUHTXLSPHQWVLQWKLVFDWDORJXHFRQWDLQIOXRULQDWHGJUHHQKRXVHJDVHV
´ µLVDZRUOGZLGHWUDGHPDUNRI)8-,768*(1(5$//,0,7('DQGLVDUHJLVWHUHGWUDGHPDUN
LQ-DSDQDQGRWKHUFRXQWULHVRUDUHDV
´ µLVDZRUOGZLGHWUDGHPDUNRI)8-,768*(1(5$//,0,7('
L3KRQHDQGL3DGDUHWUDGHPDUNVRI$SSOH,QFUHJLVWHUHGLQWKH86DQGRWKHUFRXQWULHV
´%$&QHWµLVDWUDGHPDUNRUUHJLVWHUHGWUDGHPDUNRIWKH$PHULFDQ6RFLHW\RI+HDWLQJ5HIULJHUDWLQJDQG
$LU&RQGLWLRQLQJ(QJLQHHUV,QF
´02'%86µLVDUHJLVWHUHGWUDGHPDUNRI6FKQHLGHU(OHFWULF
´/ONWORKSµDQG(FKHORQDUHWUDGHPDUNVRI(FKHORQ&RUSRUDWLRQUHJLVWHUHGLQWKH8QLWHGVWDWHVDQG
RWKHUFRXQWULHV
2WKHUFRPSDQ\DQGSURGXFWQDPHVPHQWLRQHGKHUHLQPD\EHUHJLVWHUHGWUDGHPDUNVWUDGHPDUNVRU
WUDGHQDPHVRIWKHLUUHVSHFWLYHRZQHUV
$FWXDOSURGXFWV·FRORUVPD\EHGLIIHUHQWIURPWKHFRORUVVKRZQLQWKLVSULQWHGPDWHULDO
178 179
Variable Refrigerant Flow System
Distributed by :