2 The Completer Kits provide all the basic components Size 200 Bar
necessary to operate the Argonite cylinders. The kits 15.9 L 4.5 kg
consist of hoses, connection fittings, pressure 66.7 L 19.1 kg
gauges, actuation devices required to operate the 80 L 22.5 kg
cylinder valve and warning signs to be displayed in
the area(s) protected by an Argonite fire extinguish- Area Coverage @ 38%
ing system . Concentration/70°F
Cylinder
3 The Control Panels vary in features and complexity 2900 psi
(200 bar)
but in all cases are used to monitor the detection,
actuate the alarms, initiate the agent discharge and 15.9 L 236 ft3 (6.7 M3)
control auxiliary functions such as shut down of vital 66.7 L 1003 ft3 (28.4 M3)
equipment and ventilation dampers.
80 L 1181 ft3 (33.4 M3)
4 The Detection and Alarm devices provide fire detec-
tion by means of thermal or smoke detectors, audible
and visual pre-alarm warnings and annunciation of
the Argonite discharge.
EQUIPMENT DESCRIPTION
The Chemetron ARGONITE Fire Protection Systems can
be released electrically, manually, or pneumatically. The
ARGONITE following is a description of the various components
associated with the systems.
Agent Description
Argonite is a mixture of 50% pure Nitrogen and 50% pure Cylinder and Valve Assembly
Argon. Argonite contains only naturally occurring sub- Argonite cylinders are available in three different sizes.
stances, and as such, has no ozone depletion potential The 200 bar cylinders are uniquely color coded to allow
and no direct global warming risk. for quick and easy identification. The cylinders are red
with black at the cylinder shoulder.
Argonite extinguishes by means of reducing the oxygen
content within a room to the point at which fire can no
© 2002 Chemetron Fire Systems. All rights reserved (1/2002). Chemetron Fire Systems and Argonite are registered trademarks.
ARGONITE ® Fire Protection Systems
Because Argonite is stored as a gas, the cylinders have no • Pressure Gauge and Supervisory Pressure Switch
dip tube and can be mounted in either the vertical or for slave actuator connections.
horizontal position.
3 Discharge Outlet: The cylinder valve outlet is con-
nected to the distribution piping by a flexible hose
The cylinder valve, required for all
with 1/2" steel fittings.
system cylinders, allows for con-
nection of the cylinders into the
Additional features of the valve include a Bursting Disk,
system. The valve provides con-
designed to rupture upon excessive internal pressure, and
nections for electric, pneumatic
an external Bleeder Valve with indicator that acts as a
and manual release of the cylinder
pressure relief valve.
contents, as well as a discharge
outlet, connected by a discharge
hose, to the distribution piping. PNEUMATIC PRESSURE GAUGE
ACTUATOR OR PRESSURE
GAUGE/SOLENOID
CYLINDER VALVE ASSEMBLY
The actuator operates on a 1 to 10 VALVE
ACTUATOR
ratio requiring only 300 psi for the HOSE
200 bar system to operate the
valve. The following are the con-
nections provided on the valve. DISCHARGE
HOSE
Cylinder
Dimension A Dimension B
Size
15.9 L 2' 7-5/16" (795 mm) 8" Dia (204 mm)
66.7 L 5' 3-3/16" (1605 mm) 10-1/2" Dia (267 mm)
80 L 6' 1-1/4" (1860 mm) 10-1/2" Dia (267 mm)
BRACKET
1 Manual/Pneumatic Actuator Connection: Each cy-
linder valve must be fitted with either a Pilot or
ARGONITE
Slave type actuator. CYLINDER
The Pilot actuator provides a manual (pull pin - turn Argonite Cylinder Valve Assembly
handle) actuator and connections from an electrical
solenoid and pressure switch assembly. The pilot
actuator also has connections to adjacent slave Description Stock #
cylinder actuators to discharge entire groups of
80 Liter Cylinder Assembly (filled cylinder/valve)
cylinders virtually simultaneously.
200 bar DOT & TC Version 10980002
The Slave actuator is purely pneumatic - it receives 66.7 Liter Cylinder Assy (filled cylinder/valve)
pressure from the pilot actuator and opens its
associated cylinder valve. 200 bar DOT & TC Versions 10980001
15.9 Liter Cylinder Assy (filled cylinder/valve)
2 Solenoid Valve, Pressure Gauge and Supervisory
200 bar DOT & TC Versions 10980000
Pressure Switch Connection: This is a threaded port
that serves for the connection of one of the follow- D.O.T. = Department of Transportation (US)
ing: TC = Transportation Canada
© 2002 Chemetron Fire Systems. All rights reserved (1/2002). Chemetron Fire Systems and Argonite are registered trademarks.
ARGONITE ® Fire Protection Systems
MANUAL/
PNEUMATIC
ACTUATOR
MANUAL/PNEUMATIC
CONNECTION TO ACTUATOR
CYLINDER VALVE
SOLENOID
TO BLEEDER
VALVE OR
SLAVE
CYLINDER
TEE PIECE TEE PIECE
FRONT VIEW
© 2002 Chemetron Fire Systems. All rights reserved (1/2002). Chemetron Fire Systems and Argonite are registered trademarks.
ARGONITE ® Fire Protection Systems
Tee Piece for Hose Connections (S/N 70981004)
The tee piece is supplied with each of the completer kits.
It provides the interface with the pilot assembly (through
a high-pressure flex hose) to simultaneously operate the
slave cylinder pneumatically.
© 2002 Chemetron Fire Systems. All rights reserved (1/2002). Chemetron Fire Systems and Argonite are registered trademarks.
ARGONITE ® Fire Protection Systems
Selector/Directional Valve
Restrictor Female NPT/Female NPT - Sizes 1/2" to 2"
Nozzles
Flow Restrictor
Pipe Diameter Standard The brass discharge nozzles are available in four basic
(NPT) FNPT x FNPT sizes - 1/2", 3/4", 1" and 1-1/2". Each is fitted with a drilled
orifice to assure proper flow rates, agent quality and prop-
1/2" (12.7 mm) 70984004
er discharge timing as determined by flow calculations.
1" (25.4 mm) 70984005 Maximum nozzle spacing for room mounted nozzles
1-1/2" (38.1 mm) 70984006 should not exceed 19.6 feet (6 M) square. Nozzle height
2" (50 mm) 70984007
should not exceed 16
feet (4.9 M) from a single
layer of nozzles.
Selector Valves/Directional Valves
Argonite systems are particularly suited to the use of
selector valves, where one central storage of agent is used
to provide protection to two or more hazard areas.
© 2002 Chemetron Fire Systems. All rights reserved (1/2002). Chemetron Fire Systems and Argonite are registered trademarks.
ARGONITE ® Fire Protection Systems
DISCHARGE HOSE
BLEEDER VALVE
MANUAL RELEASE
PILOT HOSE #1
PILOT HOSE #2
DISCHARGE HOSE
PILOT HOSE #3
PRESSURE GAUGE WITH
SUPERVISORY PRESSURE
SWITCH
The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchan-
tability and fitness for a particular purpose, except as expressly stated in seller's sales contract or sales acknowledgment
form. Every attempt is made to keep our product information up-to-date and accurate. All specific applications cannot
be covered, nor can all requirements be anticipated. All specifications are subject to change without notice.
© 2002 Chemetron Fire Systems. All rights reserved (1/2002). Chemetron Fire Systems and Argonite are registered trademarks.