Sunteți pe pagina 1din 2

1 2 3 4 5 6 7 8 9 10 KEY

A
N
38,912

962 27,500 9,100 1,350

A-02
A-03 200 762 200 3,300 200 3,600 200 3,400 150 1,450 200 3,500 200 1,025
150
1,025 200 3,500 200 1,450 150 3,400 200 5,000 200 3,550 150 1,200 150
150
962 1,100 1,500 1,100 3,600 1,050 1,500 1,400 900 1,550 1,500 1,200 1,025 1,025 1,200 1,500 1,450 900 1,500 1,500 850 1,498 1,000 1,000 3,452 1,000 1,000 150 1,350

A A

100

100
200 3,600 200 3,400 150 1,450 200 3,500 200 1,025 1,025 200 3,500 200 1,450 150 3,400 200 5,000 200 3,550 150 1,350

200

200

200
150

BATHS BATHS

2,750
DINING KITCHEN

2,750
200
KITCHEN

4,100
KITCHEN

3,500

4,200
4,200

150
BEDROOM BEDROOM BEDROOM

10

12

13

14

15

16

17

18
11
3,400
KITCHEN

1,100
WC

1,450
200

200
Closet Closet

B B

200

200

200
150

900
200 1,100 200 3,600 200 3,400 150 1,450 200 3,500 200 1,025 10 1,025 200 3,500 200 1,450 150 1,200 200 2,000 200 5,000 200 3,550 150 1,350

700
Closet 9 Closet
BATHS
11

1,500
2,200

2,200
8
BATHS

200

200
12
7

800
13
6

2,000
14
5 15

5,400

5,400

150
950
4

4,600
Closet

4,600
16

1,800 200

200

150
LOUNGE 3
LOUNGE
17

MASTER 2
MASTER LOUNGE

3,800
18

BATHS BATHS

800
1
BDERM BDERM

1,800
19

900
BATHS

3,350
2,500

1,750
200 1,450 150 3,400 200

1,650
200

200
200 3,600 200 3,400 150 1,450 200 3,500 200

C C

7,300
LOUNGE

200
200

200

200

200
GUEST RM

2,300
2,300

2,200

200 1,800
1,500

2,100

21,300
4,000

4,000
21,300

MASTER
D BDERM
D

400
1,250

1,200
200

300 400
1,200

300
NOTES;
E E
200

200

200

625 2,200 200

200
1 Read only figured dimensions.

2,400
2,400

10

12

13

14

15

16

17

18
11
2,200

2,200
2,200
All construction work is to comply with the
9

1
2
3,700

latest B.S standard codes of practice, Local


F F Authority By-Laws and Fire regulations.
200

200

200
3 P.V denotes permanent ventilation and must

2,200
1,000
be provided above all doors and windows
2,200

2,000

BATHS KITCHEN
where indicated or shown.

GROUND FLOOR PLAN scale 1:100

2,850
900

2,850

1,000
G G 4 All walls less than 200mm thick to be reinforced
with hoop iron at every altimate course.
200

200

200 5 Water Meter to be 300mm above G.L.

625

200
LOUNGE
6 D.p.c denotes one layer of bituminous felt to be

4,200
4,200

4,000

BEDROOM provided under all walls atleast 150mm above


4,200

3,150

3,150
3,150

TERRACE ground level.

7 All reinforced concrete works to structural


engineers details and specifications.
H H 8 Provide one row of 600 x 600 x 50mm th. pre-cast
100

200

100
200

200

200
or insitu concrete paving slabs around the building
200
1,362 1,000 1,000 1,100 1,000 1,000 1,000 1,000 1,200 1,000 1,000 1,600 200 3,500 200 2,200 200 3,500 200 1,600 700 1,000 1,000 700 200 4,400 800 750 1,000 1,000 750 600 950 as splash apron unless otherwise stated.
A-04

250 150
200 4,262 200 3,600 200 1,200 200 2,150 1,450 200 3,500 200 2,200 200 3,500 200 1,450 150 3,400 200 4,400 800 3,500 200 800 150 9 Contractors must verify all dimentions and levels
on site before commencement of works. Any
1,062 3,500 3,800 5,200 3,700 2,400 3,700 5,200 5,200 3,700 1,450 discrepancies must be reported to the Architect
before work is put in hand.
38,912
A-01 10 All levels shown are finished levels unless
otherwise stated.
1 2 3 4 5 6 7 8 9 10 11 All surface beds to be cast on well compacted
and well consolidated murram or sand infill
where aplicably stated.
12 Depth of foundation trenches to be at a min.
of 750mm below reduced ground level.

A 13 All pipes and services to be at a min. of 450mm


below reduced ground level.
No. Revision

10 9 8 7 6 5 4 3 2 1 A B C D E F G H Architect GINA NALUYIMA


REG NO. 185
P.O.Box 30452
KAMPALA
Tel 0782 500 708 PC. NO. 2424
4,200 4,600 2,300 1,200 2,400 2,200 4,200
3,700 5,200 5,200 3,700 2,400 3,700 5,200 3,800 3,500
Architect's Signature & Stamp

Client ATUHAIRE CATHERINE


P.O BOX 25439 KAMPALA
TEL: 0773836968

Client's Signature

Project
PROPOSED RESIDENTIAL HOUSE AT PLOTS
3302 & 3305, BLOCK 180 AT -KITUKUTWE
KYADONDO COUNTY,
WAKISO DISTRICT

Work stage

APPROVAL SUBMISSION DOCUMENTATION

Title

ELEVATION -A03 scale 1:100 ELEVATION -A04 scale 1:100


Drawn by Date
M.E JULY 2019
Checked by Scale
G.N AS SHOWN ON PAPER

02
Drawing no. Owners signature

GSPublisherEngine 0.1.100.100
1 2 3 4 5 6 7 8 9 10 KEY
A 38,912

962 27,500 9,100 1,350


N

A-02
A-03 200 762 200 3,300 200 3,600 200 3,400 150 1,450 200 3,500 200 1,025
150
1,025 200 3,500 200 1,450 150 3,400 200 5,000 200 3,550 150 1,200 150
150
962 1,100 1,500 1,100 3,600 1,050 1,500 1,400 900 1,550 1,500 1,200 1,025 1,025 1,200 1,500 1,450 900 1,500 1,500 850 1,498 1,000 1,000 3,452 1,000 1,000 150 1,350

A A

100

100
TERRACE

200

200

200

200

200

200

200
1,200
STUDY RM

TERRACE
BATHS BATHS

2,750
BED RM

2,750
200
KITCHEN

3,000

3,000
4,100
KITCHEN

3,500

3,500

4,200
4,200
STAIRS

150
BEDROOM BEDROOM BEDROOM

4,600

10

12

13

14

15

16

17

18
11
KITCHEN

3,400

1
BATHS

1,100
1,450
200

200
Closet Closet

B B

200

200

200
150

900
200 2,000 200 1,100 200 3,600 200 3,400 150 1,450 200 3,500 200 1,025 10 1,025 200 3,500 200 1,450 150

700
Closet 9 Closet
BATHS STAIRS
11

1,500
2,200

2,200
8
BATHS

200

200
12
7

800
13
6

2,000
14
5 15

5,400

5,400

150
950
4

4,600
Closet
4,600
16

1,800 200

200
LOUNGE 3
LOUNGE
17

MASTER 2
MASTER MASTER

3,800
18

Closet
BATHS BATHS

800
1
BDERM BDERM BDERM

1,800
19

900
BATHS

3,350
1,750
200 1,450 150
1,650
200

200
200 3,300 200 3,600 200 3,400 150 1,450 200 3,500 200

C C

7,300
LOUNGE

200
BED RM

200

200

200

2,300
2,300

2,200

200 1,800
1,500

2,100
TERRACE TERRACE

21,300
4,000
21,300

4,000

MASTER
TERRACE
D BDERM TERRACE
D

400
1,250

1,200
200

300 400
1,200

300
E E NOTES;
200

200

200

625 2,200 200

200

2,400
1 Read only figured dimensions.
2,400

10

12

13

14

15

16

17

18
11
2,200

2,200
2,200
9

1
3,700

2 All construction work is to comply with the

F F latest B.S standard codes of practice, Local


Authority By-Laws and Fire regulations.
200

200

200
3 P.V denotes permanent ventilation and must

2,200
1,000
2,200

2,000

BATHS KITCHEN be provided above all doors and windows

2,850
900

2,850
where indicated or shown.

1,000
G
FIRST FLOOR PLAN scale 1:100 G 4 All walls less than 200mm thick to be reinforced
200

200

with hoop iron at every altimate course.


200

625

200
5 Water Meter to be 300mm above G.L.
LOUNGE

4,200
4,200

6 D.p.c denotes one layer of bituminous felt to be


4,000

BEDROOM
4,200

provided under all walls atleast 150mm above

3,150

3,150
3,150

TERRACE
ground level.

7 All reinforced concrete works to structural


H H engineers details and specifications.
100

200

100
200

200

200
8 Provide one row of 600 x 600 x 50mm th. pre-cast
1,362 1,000 1,000 1,100 1,000 1,000 1,000 1,000 1,200
200
1,000 1,000 1,600 200 3,500 200 2,200 200 3,500 200 1,600 700 1,000 1,000 700 200 4,400 800 750 1,000 1,000 750 600 950
or insitu concrete paving slabs around the building
A-04

250 150
as splash apron unless otherwise stated.
200 4,262 200 3,600 200 1,200 200 2,150 1,450 200 3,500 200 2,200 200 3,500 200 1,450 150 3,400 200 4,400 800 3,500 200 800 150
9 Contractors must verify all dimentions and levels
1,062 3,500 3,800 5,200 3,700 2,400 3,700 5,200 5,200 3,700 1,450 on site before commencement of works. Any
discrepancies must be reported to the Architect
38,912
A-01 before work is put in hand.
10 All levels shown are finished levels unless
1 2 3 4 5 6 7 8 9 10 otherwise stated.

11 All surface beds to be cast on well compacted


and well consolidated murram or sand infill
where aplicably stated.
12 Depth of foundation trenches to be at a min.
of 750mm below reduced ground level.
A 13 All pipes and services to be at a min. of 450mm
below reduced ground level.
No. Revision

1 2 3 4 5 6 7 8 9 10 H G F E D C B A
Architect GINA NALUYIMA
REG NO. 185
P.O.Box 30452
4,200 2,200 2,400 1,200 2,300 4,600 4,200 KAMPALA
3,500 3,800 5,200 3,700 2,400 3,700 5,200 5,200 3,700 Tel 0782 500 708 PC. NO. 2424

Architect's Signature & Stamp

Client ATUHAIRE CATHERINE


P.O BOX 25439 KAMPALA
TEL: 0773836968

Client's Signature

Project
PROPOSED RESIDENTIAL HOUSE AT PLOTS
3302 & 3305, BLOCK 180 AT -KITUKUTWE
KYADONDO COUNTY,
WAKISO DISTRICT

Work stage

APPROVAL SUBMISSION DOCUMENTATION

Title

ELEVATION -A01 scale 1:100 ELEVATION -A02 scale 1:100


Drawn by Date
M.E JULY 2019
Checked by Scale
G.N AS SHOWN ON PAPER

03
Drawing no. Owners signature

GSPublisherEngine 0.1.100.100

S-ar putea să vă placă și