Quick Setup Guide Q 528

tekmarNet®2 Thermostat 528 08/10


Zoning Replaces: 10/09

1. Location 2. Remove Mounting Base


Interior
Wall

5 feet
1.5 m

Exterior
Wall

3. Install Mounting Base 4. Wiring

1023-02
528
tNt 528
One Stage Heat

Mmm YYYY
Lot # 12345
Adaptor ON

Plate 007

Setback
Scene
None
Lock
Thermostat

Switch Settings:

Cool Member 1
Thermostat Base

Canadian ICES
Meets Class B:
FCC Part 15
Base OR

Unlock
For instructions see brochure
Use at least 65°C conductors

Off
Off
Made in
No Power Canada 1 2 3 4
tN2 tN2 Sensor
1 2 3 4
1 2 3 4
Wall

Switch
Box Switch Setting Location

tN2 tN2
Slab Sensor 079, or
tN2 Manager, Module Outdoor Sensor 070, or
or Wiring Center Indoor Sensor 076, 077, 084

5. Switch Settings 6. Close Thermostat


Switch Position Action
SETBACK Allow thermostat to respond to
ON
1 available schedule. Requires Timer 033.
OFF OFF No setback schedule response.
SCENE Allow thermostat to respond to
ON
2 scenes. Requires User Switch 479.
OFF OFF No scene response.
NONE The thermostat is not part of a
ON
cooling group.
3
COOL MEMBER 1 The thermostat is a
OFF
member of cooling group number 1.
ON
LOCK Locked to ‘User’ access level. Set pivot
to Lock when installation completed.
4 tab
UNLOCK Unlock to access all settings.
OFF
Set to Unlock during installation.

1 of 2 © 2010 Q 528 - 08/10


7. User Interface

8. Critical Settings
The following settings are essential to the successful operation of the system.
Important Note: Set switch setting #4 and tekmarNet® system control to Unlock to change Access level to Installer. Return to Lock
setting once installation has been completed.

Press • Press and hold down both the and buttons for 2 seconds to change from one step to the next.
• Release both buttons once the step has been reached.
+ • Press the or the button to change the setting, if available.
• Press and hold down both the and buttons for 2 seconds to go to the next step, OR
Together • After 10 seconds of no button activity, the display goes back to normal operation.

Display Range Access Description Set to

Installer TEMPERATURE UNITS


°F or °C
Default = °F Press the or the button to change from °F to
User °C and vice versa.

ROOM SENSOR
Select whether the built-in air temperature sensor is
On or Off on or off.
Installer Available when:
Default = On
A floor sensor or room sensor is installed on the
auxiliary sensor input.
AUXILIARY SENSOR
Off, Room, Select the type of auxiliary sensor.
Outdoor, Floor dSP = Show floor sensor reading in upper
Installer number field.
Floor, Floor
dSP Available when:
Auxiliary sensor automatically detected.
HEATING SUPPLY PUMP
Select how the system supply pump should operate:
On = system pump on during a call for heat.
OFF, dLy Delay = system pump delayed 3 minutes for thermal
(delay), On Installer motor (wax actuator) zone valves to open.
Default = On Off = system pump not turned on during a call for heat.
Use when a manifold uses a Zone Group Pump.
Available when:
• A reset control is present on the tekmarNet® system.

For a full list of settings and operational details, please refer to the thermostat Installation and Operation Manual
(D528) included with compatible tekmarNet® controls or download the brochure from www.tekmarcontrols.com

tekmar Control Systems Ltd., Canada, tekmar Control Systems, Inc., U.S.A. Head Office: 5100 Silver Star Road,
Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarcontrols.com
Product design, software and literature are Copyright © 2010 by: All specifications are subject to change without notice.
tekmar Control Systems Ltd. and tekmar Control Systems, Inc.