PROPERTY OF
M. Tiedt Nov. 19, 2001 EB 878G
AP APPROVED DATE Page 1 of 4
E. Wehner Nov. 19, 2001 A1
General
The purpose of this Engineering Bulletin is to provide a cross-reference between current API
6A Material Classes and Trim designations used for Cameron products prior to API 6A 16T h Edition.
This document does not take into account the temperature rating of the equipment. Some of
these old Trim designations included equipment designed for a specific temperature range, and others
included multiple temperature ranges. Please refer to assembly part number description for actual
temperature rating of equipment.
Table I should be used for reference only because materials used in equipment manufactured prior to
API 6A 15th Edition may or may not meet the current requirements of Table I.
Tables
Table I
Notes:
Temperature classes may be combined. For example, P+U = -20 to 250 o F (-20 to 182 o C).
DR DRAWN BY DATE REVISION
PROPERTY OF
M. Tiedt Nov. 19, 2001 EB 878G
AP APPROVED DATE Page 3 of 4
E. Wehner Nov. 19, 2001 A1
Table III
Table VI
Foster Gate Valve Trim and Retained Fluid Designations
API 6A 15th Edition Current
Old Trim Designations
Retained Fluid Class API 6A Material Class
FT-21 A AA
FT-22 B BB
FT-23 C CC
FT-24 E EE
FT-26 F FF
FT-36 A AA
FT-37 E EE
Table VII
GULFCO Gate Valve Trim and Retained Fluid Designations
API 6A 15th Edition Current
Old Trim Designations Retained Fluid Class API 6A Material Class
C-1 A AA
C-2 B BB
C-3 C CC
C-4 E EE
C-5 F FF
C-6 D DD
Table VIII
USV/SSV Service Class Designations
API 14D Service Class Designations
Current
Standard Class Designations Sandy Class Designations API 6A Material Class
1 2 AA
1-3S 2-3S DD
1-3C 2-3C Contact Engineering
1-3S-3C 2-3C Contact Engineering
1-4 2-4 CC
1-3S-4 2-3S-4 FF
1-3C-4 2-3C-4 FF
1-3S-3C-4 2-3S-3C-4 FF or HH
Note: API 14D was withdrawn in 1996. The Surface Safety Valve (SSV) and Underwater Safety
Valve (USV) valve requirements for the US offshore regulatory program are now included in API
6A, Section 10.20. An API 14D Standard Service valve is now designated as API 6A SSV / USV,
PR1, and API 14D Sandy Service valves are now designated as API 6A SSV/USV, PR2. The PR1
and PR2 requirements for SSV’s and USV’s are not the same as for other valves covered by
API spec 6A.