powersolutions.danfoss.com
Technical Information
Series 51 and 51-1 Bent Axis Variable Displ. Motors
October 2017 Modified theor. corner power ratings and updated to Engineering Tomorrow 0401
March 2015 Major update. Corrected DITA CMS structure, layout, colors and all tables. CA
Contents
Contents
Options F1A5, F2A5 – electrohydraulic two-position control for 51 (frame size 160, 250).................................46
F1A5, F2A5 solenoid connectors.........................................................................................................................................47
Options T1**, T2**, T7** – electrohydraulic two-position control for 51-1 (frame size 060, 080, 110)........... 48
Option T*CA: pressure compensator configuration with hydraulic Brake Pressure Defeat..........................49
Options T*D1, T*D2, T* D7: pressure compensator configuration with electric BPD...................................... 49
T1D1, T2D2, T7D7 solenoid connectors...................................................................................................................... 50
Option T*C2: pressure compensator configuration without Brake Pressure Defeat....................................... 50
Options T1**, T2** – electrohydraulic two-position control for 51 (frame size 160, 250)................................... 51
Option T*C0: pressure compensator configuration with hydraulic Brake Pressure Defeat.......................... 52
Option T*C2: pressure compensator configuration without Brake Pressure Defeat....................................... 52
T1C2, T2C2 solenoid connectors................................................................................................................................... 52
Options EP**, EQ** – electrohydraulic proportional control for 51 (all frame sizes)............................................. 53
Pressure Compensator Override (PCOR)..........................................................................................................................54
Options EPA1, EQA1: pressure compensator configuration with Brake Pressure Defeat.............................. 55
Options EPA2, EQA2: pressure compensator configuration without Brake Pressure Defeat....................... 55
Options L1B1, L2B1, L7B1 – electrohydraulic proportional control for 51 (all frame sizes)................................ 56
L1B1, L2B1, L7B1 solenoid connectors..............................................................................................................................57
Options D7M1, D8M1 – electrohydraulic proportional control with PCOR and hydraulic BPD for 51
(all frame sizes)........................................................................................................................................................................ 58
Options D7M1, D8M1: pressure compensator configuration with hydraulic Brake Pressure Defeat........59
D7M1, D8M1 solenoid connector..................................................................................................................................59
Options HS** – hydraulic proportional control for 51 (all frame sizes)...................................................................... 60
Pressure Compensator OverRide (PCOR).........................................................................................................................60
Option HSA1: pressure compensator configuration with Brake Pressure Defeat.............................................61
Option HSA2: pressure compensator configuration without Brake Pressure Defeat......................................61
Option HZB1 – hydraulic proportional control for 51 (all frame sizes).......................................................................62
General dimensions – frame size 060
SAE flange design per ISO 3019/1............................................................................................................................................64
DIN flange design per ISO 3019/2............................................................................................................................................67
Cartridge flange..............................................................................................................................................................................70
General dimensions – frame size 080
SAE flange design per ISO 3019/1............................................................................................................................................73
DIN flange design per ISO 3019/2............................................................................................................................................76
Cartridge flange..............................................................................................................................................................................79
General dimensions – frame size 110
SAE flange design per ISO 3019/1............................................................................................................................................82
DIN flange design per ISO 3019/2............................................................................................................................................85
Cartridge flange..............................................................................................................................................................................88
General dimensions – frame size 160
SAE flange design per ISO 3019/1............................................................................................................................................91
DIN flange design per ISO 3019/2............................................................................................................................................93
Cartridge flange..............................................................................................................................................................................95
General dimensions – frame size 250
SAE flange design per ISO 3019/1............................................................................................................................................97
Dimension – Controls
Options TA** for 51-1 – Pressure Compensator Control (Frame Size: 060, 080, 110)........................................... 99
Options TA** for 51 – Pressure Compensator Control (Frame Size: 160, 250)...................................................... 100
Options TH** for 51-1 – Hydraulic Two-Position Control (Frame Size: 060, 080, 110)........................................101
Options TH** for 51 – Hydraulic Two-Position Control (Frame Size: 160, 250)..................................................... 102
Options E*B1, F*B1 for 51-1 – Electrohydraulic Two-Position Control (Frame Size: 060, 080, 110)...............103
Options E*A5, F*A5 for 51 – Electrohydraulic Two-Position Control (Frame Size: 160, 250)........................... 104
Options T1**, T2**, T7** for 51-1 – Electrohydraulic Two-Position Control (Frame Size: 060, 080, 110).....105
Options T1C2, T2C2 for 51 – Electrohydraulic Two-Position Control (Frame Size: 060, 080, 110)................. 106
Options EPA1, EQA1 for 51 – Electrohydraulic Two-Position Control (All Frame Sizes).................................... 107
Options L1B1, L2B1, L7B1 for 51 – Electrohydraulic Two-Position Control (All Frame Sizes).......................... 108
Options D7M1, D8M1 for 51 – Electrohydraulic Two-Position Control (Frame Size: 060, 080, 110)............. 109
Contents
Options D7M1, D8M1 for 51 – Electrohydraulic Two-Position Control (Frame Size: 160, 250).......................110
Option HSA* for 51 – Hydraulic Proportional Control (All Frame Sizes)..................................................................111
Option HZB1 for 51 – Hydraulic Proportional Control (All Frame Sizes)................................................................. 112
Series 51 and 51-1 variable displacement motors are bent axis design units, incorporating spherical
pistons.
These motors are designed primarily to be combined with other products in closed circuit systems to
transfer and control hydraulic power. Series 51 and 51-1 motors have a large maximum / minimum
displacement ratio (5:1) and high output speed capabilities. SAE, cartridge, and DIN flange configurations
are available.
A complete family of controls and regulators is available to fulfill the requirements of a wide range of
applications.
Motors normally start at maximum displacement. This provides maximum starting torque for high
acceleration.
The controls may utilize internally supplied servo pressure. They may be overridden by a pressure
compensator which functions when the motor is operating in motor and pump modes. A defeat option is
available to disable the pressure compensator override when the motor is running in pump mode.
The pressure compensator option features a low pressure rise (short ramp) to ensure optimal power
utilization throughout the entire displacement range of the motor. The pressure compensator is also
available as a stand-alone regulator.
• The series 51 and 51-1 motors – Advanced technology
• The most technically advanced hydraulic units in the industry
• SAE, cartridge, and DIN flange motors
• Cartridge motors designed for direct installation in compact planetary drives
• Large displacement ratio (5:1)
• Complete family of control systems
• Proven reliability and performance
• Optimum product configurations
• Compact, lightweight
4 8 9 10 11 12
6 5
1
3 7 P001196
Legend:
1 – Piston
2 – Flange
3 – Servo piston
4 – Electric proportional control
5 – Synchronizing shaft
6 – Speed sensor
7 – Charge pressure relief valve
8 – Minimum displacement limiter
9 – Valve segment
10 – Bearing plate
11 – Speed pickup ring
12 – Tapered roller bearings
8 9 10 11 12
6 5
3 1
7 4 P001831
Legend:
1 – Piston
2 – Flange
3 – Servo piston
4 – Electrohydraulic two-position control
5 – Synchronizing shaft
6 – Speed sensor
7 – Charge pressure relief valve
8 – Minimum displacement limiter
9 – Valve segment
10 – Bearing plate
11 – Speed pickup ring
12 – Tapered roller bearings
Pictorial diagram
Displacement
Control handle control valve Heat exchanger
Bypass valve
Reservoir
M3 L2 M4 M3 N
A A
M1 M1
n
M4
max.
disp.
M5
T3
T2
T7 T8
T1 M5
M2
B B M2
S L2 L1 X1 M7
Signal pressure supply
P001833E
Above schematic shows the function of a hydrostatic transmission using a Series 90 Axial Piston Variable
Displacement Pump with manual displacement control (MA) and a Series 51 Bent Axis Variable
Displacement Motor with hydraulic two-position control (HZ).
Neumünster/Germany Ident
number
Model No./Ident. No. 5084092
Model
Model Code 51V080 RS1N
code L1B1 WB31 ADA
051AAF0 D400 Serial
number
Serial No. N982211215
Barcode
serial number
Made in Germany
Place of manufacture
P001 832E
508 4092
Neumünster/Germany Ident
number
Model No./Ident. No. 511685
Model
Model Code 51D110-1-RD4N
code E1B1 NNU2 ADD
030AAA3 0000 Serial
number
Serial No. N973212355
Barcode
serial number
Made in Germany
Place of manufacture
P001 832E
511 685
Technical specifications
General specifications
Most specifications for bent axis variable displacement motors are listed on these pages. For definitions
of the various specifications, see the related pages in this publication. Not all hardware options are
available for all configurations; consult the series 51 and 51-1 model code supplement or price book for
more information.
General specifications
Design Axial piston motor with variable displacement, bent axis design
Recommended installation Discretionary, the housing must always be filled with hydraulic fluid
Other system requirements Independet braking system, circuit overpressure protection, suitable reservoir
Specific data
Physical properties
Size
Features Unit
060 080 110 160 250
Theor. flow at at rated speed l/min 216 [57] 250 [66] 308 [81] 402 [106] 550 [145]
max. displ. at max. speed [US gal/min] 264 [71] 323 [85] 396 [105] 515 [136] 675 [178]
Technical specifications
Fluid specifications
Fluid specifications
Features Unit All sizes
2) Minimum: cold start, short term t<3 min, p<50 bar, n<1000 rpm.
Technical specifications
Vg • n Vg • n
Qe = Qe =
1000 • v 231 • v
Vg • p • Vg • p •
Me = mh
Me = mh
20 • 2•
Me • n Q • p• Vg • n • p •
Pe = = e t
Pe = t
Qe • 1000 • Qe • 231 •
n = v
n = v
Vg Vg
Where: Where:
Case pressure
Under normal operating conditions, case pressure must not exceed the rated pressure. Momentary case
pressure exceeding this rating is acceptable under cold start conditions, but still must stay below the
maximum pressure rating.
The minimum pressure provides proper lubrication at high speeds.
Operation with case pressure in excess of these limits may result in external leakage due to damage to
seals, gaskets, and/or housings.
Case pressure
Parameter Unit All sizes
Rated 3 [44]
Speed range
Rated speed is the speed limit recommended at full power condition and is the highest value at which
normal life can be expected.
Maximum speed is the highest operating speed permitted and cannot be exceeded without reduction
in the life of the product or risking immediate failure and loss of driveline power (which may create a
safety hazard). In the range between rated and maximum speed please contact your Danfoss Power
Solutions representative.
W Warning
The loss of hydrostatic drive line power in any mode of operation (e.g., forward, reverse, or “neutral”) may
cause the loss of hydrostatic braking capacity. A braking system, redundant to the hydrostatic
transmission must, therefore, be provided which is adequate to stop and hold the system should the
condition develop.
Speed limits
Size
Features Unit
060 080 110 160 250
Speed limits
Maximim speed
at min. displacement Curve determined by rated flow
Maximum speed
at max. displacement
Rated speed
at min. displacement
For operation within the range above the acceptable range contact Danfoss Power Solutions
representative.
Pressure limits
System pressure is the dominant operating variable affecting hydraulic unit life. High pressure, which
results from high load, reduces expected life in a manner similar to the affects of high load on other
mechanical assemblies such as engines and gear boxes. There are load-to-life relationships for the
rotating group and for the shaft anti-friction bearings.
Continuous pressure is the pressure at which the hydrostatic system could operate continuously and still
achieve acceptable hydrostatic life. This pressure level varies depending on operating speed, and on the
life requirements for a particular application. While most mobile applications require system pressure to
vary widely during operation, a “weighted average” pressure can be derived from a machine duty cycle.
(A duty cycle is a means of quantifying the pressure and speed demands of a particular system on a
percent time basis). Once a duty cycle has been determined or estimated for a specific application,
contact your Danfoss representative for system life ratings for the application.
Maximum delta pressure is the highest intermittent pressure allowed, and is the relief valve setting. It is
determined by the maximum machine load demand. For most systems, the load should move at this
pressure.
Maximum pressure is assumed to occur a small percentage of operating time, usually less than 2 % of
the total. Both the continuous and maximum pressure limits must be satisfied to achieve the expected
life.
Minimum low pressure must maintained under all operating conditions to avoid cavitation.
Loop flushing
An integral non-adjustable loop flushing valve is incorporated into all these motors. Installations that
require fluid to be removed from the low pressure side of the system circuit because of cooling
requirements or contamination removal will benefit from loop flushing.
The integral loop flushing valve is equipped with an orificed charge pressure relief valve designed with a
cracking pressure of 16 bar [232 psi].
Valves are available with several orifice sizes to meet the flushing flow requirements of all system
operating conditions.
The total system charge pump flow should be of sufficient volume to accommodate:
• The number of motors in the system
• System efficiency under worst case conditions
• Pump control requirements
• External needs
Although charge pump sizing requires the consideration of many system variables, the following table
gives a recommendation of what charge pump displacement may be required to accommodate the
flushing flow of each available charge relief valve orifice.
W Warning
The loss of hydrostatic drive line power in any mode of operation (e.g., forward, reverse, or “neutral”
mode) may cause the loss of hydrostatic braking capacity. A braking system, redundant to the hydrostatic
transmission must, therefore, be provided which is adequate to stop and hold the system should the
condition develop.
Loop flushing valve
Loop flushing shuttle spool
Hydraulic schematic
A B
P001 830
Equation:
Where:
QFlush – flushing flow per motor
QCharge – charge flow at operating speed
kMo – number of motors feeded by one pump
QLeak – sum of external leakages
QLeak includes:
• motor leakage
• pump leakage + internal consumers:
‒ 8 l/min [2.11 US gal/min] for displacement control pumps or
‒ for non-feedback controlled pumps at 200 bar [2900 psi]
• external consumers:
‒ e.g. brakes, cylinders, and other pumps
Hydraulic fluids
Ratings and data are based on operating with hydraulic fluids containing oxidation, rust and foam
inhibitors. These fluids must possess good thermal and hydrolytic stability to prevent wear, erosion and
corrosion of the internal components.
Fire resistant fluids are also suitable at modified operating conditions. Please see Danfoss literature
Technical Information Hydraulic Fluids and Lubricants for more information.
For more information contact your Danfoss representative.
C Caution
2) Minimum: cold start, short term t<3 min, p<50 bar, n<1000 rpm.
Filtration system
To prevent premature wear, ensure that only clean fluid enters the hydrostatic transmission circuit. A
filter capable of controlling the fluid cleanliness to ISO 4406, class 22/18/13 (SAE J1165) or better, under
normal operating conditions, is recommended.These cleanliness levels cannot be applied for hydraulic
fluid residing in the component housing/case or any other cavity upon delivery from the factory.
The filter may be located on the pump (integral) or in another location (remote or suction). The integral
filter has a filter bypass sensor to signal the machine operator when the filter requires changing. Filtration
strategies include suction or pressure filtration. The selection of the filter strategy depends on a number
of factors including the contaminant ingression rate, the generation of contaminants in the system, the
required fluid cleanliness, and the desired maintenance interval. Filters are selected to meet the above
requirements using rating parameters of efficiency and capacity.
Filter efficiency can be measured with a Beta ratio (βX). For simple suction-filtered closed circuit
transmissions and open circuit transmissions with return line filtration, a filter with a β-ratio within the
range of β35-45 = 75 (β10 ≥ 2) or better has been found to be satisfactory. For some open circuit systems,
and closed circuits with cylinders being supplied from the same reservoir, a higher filter efficiency is
recommended. This also applies to systems with gears or clutches using a common reservoir. For these
systems, a charge pressure or return filtration system with a filter β-ratio in the range of β15-20 = 75 (β10 ≥
10) or better is typically required.
Because each system is unique, only a thorough testing and evaluation program can fully validate the
filtration system. For more information, see Design Guidelines for Hydraulic Fluid Cleanliness, Technical
Information BC00000095.
Filter βx-ratio is a measure of filter efficiency defined by ISO 4572. It is defined as the ratio of the number
of particles greater than a given diameter (“x” in microns) upstream of the filter to the number of these
particles downstream of the filter.
Fluid selection
Ratings and performance data are based on operating with hydraulic fluids containing oxidation, rust
and foam inhibitors. These fluids must possess good thermal and hydrolytic stability to prevent wear,
erosion, and corrosion of motor components.
C Caution
Never mix hydraulic fluids of different types.
Fire resistant fluids are also suitable at modified operating conditions. For more information, see
Hydraulic Fluids and Lubricants, Technical Information BC00000093.
Reservoir
The function of the reservoir is to remove air and to provide make up fluid for volume changes associated
with fluid expansion or contraction, possible cylinder flow, and minor leakage.
The reservoir should be designed to accommodate maximum volume changes during all system
operating modes and to promote deaeration of the fluid as it passes through the tank.
A minimum reservoir volume equal to 1/2 to 1 1/2 times charge pump flow/min is suggested. This allows
30 seconds fluid dwell for removing entrained air at the maximum return flow. This is usually adequate to
allow for a closed reservoir (no breather) in most applications. The reservoir outlet to the charge pump
inlet should be above the bottom of the reservoir to take advantage of gravity separation and prevent
large foreign particles from entering the charge inlet line.
The reservoir inlet (fluid return) should be positioned so that the flow to the reservoir is discharged below
the normal fluid level, and also directed into the interior of the reservoir for maximum dwell and efficient
deaeration.
W Warning
The loss of hydrostatic drive line power in any mode of operation (e.g., forward, reverse, or “neutral”
mode) may cause the loss of hydrostatic braking capacity. A braking system, redundant to the hydrostatic
transmission must, therefore, be provided which is adequate to stop and hold the system should the
condition develop.
Lifetimes for speeds other than 1500 min-1 (rpm) can be calculated from:
L1 • 1500
L2 = hours
n2
Where: Units:
L1 = Rated L10 life at 1500 min-1 (rpm) hours
n2 = Operating speed min-1 (rpm)
Contact your Danfoss Power Solutions representative for bearing life values at other pressure and angle.
Fr
Fa
X1
Fr
Fa
X1
Fr
Fa
P001 166E
Max. allowable bending moment M N•m 252 307 766 805 970
[lb•in] [2230] [2717] [6780] [7125] [8585]
Max. allowable axial load at pressure N/bar 10.4 12.6 15.2 19.2 26.4
Fa/∆p [161] [195] [236] [298] [409]
[lb/1000 psi]
Distance SAE mounting flange 33.6 33.6 62.7 52.7 45.3
[1.32] [1.32] [2.47] [2.07] [1.78]
Distance DIN mounting flange 57.2 57.6 94.7 84.7
X1 –
[2.25] [2.27] [3.73] [3.33]
mm [in]
Distance Cartridge mount. flange 117.6 136.1 177.5
– –
[4.63] [5.36] [7.0]
Basic distance A 25.2 25.6 54.7 44.7 37.3
[0.99] [1.01] [2.15] [1.76] [1.47]
– = not available
The values in the table are maximum values and are not allowed under continuous load conditions.
Allowable external shaft load, when shaft load distance is different from standard
Use this formula to calculate maximum allowable radial load when max. shaft load distance X2 is different
from X1:
X2 is the actual distance of Fr from the mounting flange to the load for a given application. If X2< X1, Fr
could also be calculated by the first equation, but in addition the bearing life has to be checked.
Contact your Danfoss representative for load ratings of specific shafts or when the load orientation
deviates more than 35° in either direction from the optimum.
ar [6090 psi]
η v = 420 b
95
] tota
0 psi η = l efficie
Efficiency %
9
[60 t 210 ncy
bar bar
90 0 [30
42 5 0p
= si]
η
t
85
80
0 25 50 75 100
Speed % of rated speed P001 155E
This graph shows typical overall efficiencies for Series 51 and 51-1 motors operating at maximum
displacement and system pressures up to 420 bar [6090 psi], and a fluid viscosity of 8.2 mm²/s [53 SUS].
These efficiencies can be used for all frame sizes.
Overall efficiency at maximum displacement
420
[6090]
280
System pressure bar [psi]
[4060] 94.5%
93.5%
140
[2030] 90.5%
84.5%
74.5%
0
0 25 50 75 100
Speed % of rated speed
P001 137E
This graph shows typical overall efficiencies for Series 51 and 51-1 motors operating at 30% of maximum
displacement and system pressures up to 420 bar [6090 psi], and a fluid viscosity of 8.2 mm²/s (53 SUS).
These efficiencies can be used for all frame sizes.
95
volumetric efficiency η v = 210 bar [3050 psi]
90
η v = 420 bar [6090 psi]
85
Efficiency %
70
65
60
0 25 50 75 100
Speed % of rated speed P001 156E
This graph shows typical overall efficiencies for Series 51 and 51-1 motors operating at 30% of maximum
displacement and system pressures up to 420 bar [6090 psi], and a fluid viscosity of 8.2 mm²/s (53 SUS).
These efficiencies can be used for all frame sizes.
Overall efficiency at 30% of maximum displacement
420
[6090]
bar [psi]
280
[4060]
81%
System pressure
80%
140
[2030] 77%
71%
61%
0
0 25 50 75 100
Speed % of rated speed P001 138E
Speed sensor
An optional speed sensor for direct measurement of speed is available. This sensor may also be used to
sense the direction of rotation. A special magnetic speed pick-up ring is pressed onto the outside
diameter of the shaft and a Hall effect sensor is located in the motor housing. The sensor accepts supply
voltage and outputs a digital pulse signal in response to the speed of the ring. The output changes its
high/low state as the north and south poles of the permanently magnetized speed ring pass by the face
of the sensor. The digital signal is generated at frequencies suitable for microprocessor based controls.
The sensor is available with different connectors (see below). The SAE and DIN flange motors use a flat
end speed sensor. The cartridge flange motors use a conical end speed sensor.
Pulze/Rev 45 49 54 61 71
P001 492
P002 108E
Packard Weather-Pack
4 pin A
(Supplied Connector) B
Mating Connector C
No.: K03379 D
P001 758E
Id.-No.: 505341
Roller compactor1)
Paver wheeled1)
Paver tracked1)
Sweeper1)
Trencher1)
Excavator wheeled1)
Agricultural1)
Forestry1)
Telehandler1)
Railroad1)
Snow groomer1)
Snow blower2)
Crane3)
Suitable configuration
1) Propel function
3) Winch function
The table above is provided to assist in selecting controls and regulators for various applications. These
recommendations are based on experience with a wide range of applications.
Contact your Danfoss Power Solutions representative for more information on control selection.
Option N1NN – hydraulic two-position control for 51-1 (frame size: 060, 080, 110)
L2 N
A
n
min.
disp.
T3
T2
X1 M5
(M3) B
L1 M4 P001 779E
Displacement changes from maximum displacement to minimum displacement position, under load, as
control pressure at port X1 (M3) is equal to low pressure or higher.
Control pressure on port X1 (M3)
No pressure on port = maximum displacement
Control pressure on port = minimum displacement
Maximum control pressure = 50 bar [725 psi]
The graph shows the necessary external and internal (= low system pressure) control pressure X1, which
is needed to stroke the motor depending on high system pressure.
Control N1NN necessary control pressure
30
[435]
Servo pressure bar [psi]
20
[290]
0
0 100 200 300 400
[1450] [2900] [4350] [5800]
System pressure bar [psi]
P001 877E
Control pressure
min max
Displacement
P001 875E
Option HZB1 – hydraulic two-position control for 51 (frame size: 160, 250)
L2 M4 M3 N
A
M1
n
max.
disp.
T3
T2
T7 T8
T1
M5
B M2
L1 X1 M7 P100 177E
Displacement can be changed hydraulically under load from minimum displacement to maximum
displacement and vice versa by control pressure to port X1. For proportional control see Option HZB1 –
hydraulic proportional control for 51 (all frame sizes) on page 62
Control pressure on port X1
Options TA** – pressure compensator control for 51-1 (frame size: 060, 080, 110)
Circuit diagram–motor with pressure compensator control TA**
L2 N
XB XA A
n
min.
disp.
T3 T3 T3
M3 M3 M3
with Electric with Hydraulic without B
brake pressure brake pressure Brake pressure L1 M4
defeat defeat defeat P001 834E
Ports:
min max
Displacement
P001 173E
Option TACA: pressure compensator configuration with hydraulic Brake Pressure Defeat
A shuttle valve ahead of the pressure compensator prevents operation in the deceleration direction
(when motor is running in pump mode). This is designed to prevent rapid or uncontrolled deceleration
while the vehicle/machine is slowing down. Pressure compensator override with brake pressure defeat is
mainly used in systems with pumps having electric or hydraulic proportional controls or automotive
controls.
The shuttle valve must be controlled by a 2-line external signal, based on direction of motor rotation,
based on the following table:
Motor rotation High pressure port Control pressure on port* PCOR function
CW A XA yes
CW A XB no
CCW B XA no
CCW B XB yes
* Differencial control pressure between port XA/XB:
∆pmin = 0.5 bar [7 psi]
∆pmax = 50 bar [725 psi]
Options TAD1, TAD2, TAD7: pressure compensator configuration with electric BPD
A solenoid-switched valve ahead of the pressure compensator prevents operation in the deceleration
direction (when motor is running in pump mode). This is designed to prevent rapid or uncontrolled
deceleration while the vehicle/machine is slowing down.
The solenoid valve must be controlled by an external electric signal, based on direction of motor rotation,
see the following table:
Options TA** – pressure compensator controls for 51 (frame size 160, 250)
Circuit Diagram–Motor with Pressure Compensator Control TA**
L2 M4 M3 N
XA A
X4 X4
M1
n
max.
disp.
T2 T3
(X3)
T1 T7 T8 M5
XB B M2
with without
Brake pressure Brake pressure L1 P001 836E
defeat defeat
Ports:
Regulator start
Setting range
P001 173E
Option TAC0: pressure compensator configuration with hydraulic Brake Pressure Defeat
A shuttle valve ahead of the pressure compensator prevents operation in the deceleration direction
(when motor is running in pump mode). This is designed to prevent rapid or uncontrolled deceleration
while the vehicle/machine is slowing down.
Pressure compensator override with brake pressure defeat is mainly used in systems with pumps having
electric or hydraulic proportional controls or automotive controls.
The shuttle valve must be controlled by a 2-line external signal, based on direction of motor rotation, see
the following table.
Motor rotation High pressure port Control pressure on port* PCOR function
CW A XA no
CW A XB yes
CCW B XA yes
CCW B XB no
* Differencial control pressure between port XA/XB:
∆pmin = 0.5 bar [7 psi]
∆pmax = 50 bar [725 psi]
Options TH** – hydraulic two-position control for 51-1 (frame size: 060, 080, 110)
Circuit diagram – motor with two-position control TH**
L2 N
A
XB XA
min.
disp.
T3 T3 T3
X1 M3 X1 M3 X1 M3
B
with Electric with Hydraulic without
brake pressure brake pressure Brake pressure L1 M4
defeat defeat defeat P001 835E
Ports:
Displacement can be changed hydraulically under load from minimum displacement to maximum
displacement and vice versa.
Pressure on port X1 must be equal to the pressure of the motor case ± 0.2 bar [3.0 psi] this keeps the
motor at minimum displacement.
Pressure from 10 bar [145 psi] to 35 bar [510 psi] above case pressure on port X1 strokes the motor to
maximum displacement.
Pressure compensator
override bar, [psi]
setting range
PCOR start
130 370 [5370]
Hydraulic
two-position-
control
[1890]
[145 psi]
min. 10 bar
[510 psi]
Ramp < 10
[145]
max. 35 bar
min. max.
Displacement
P001 776E
Option THCA: pressure compensator configuration with hydraulic Brake Pressure Defeat
A shuttle valve ahead of the pressure compensator prevents operation in the deceleration direction
(when motor is running in pump mode). This is designed to prevent rapid or uncontrolled deceleration
while the vehicle/machine is slowing down. Pressure compensator override with brake pressure defeat is
mainly used in systems with pumps having electric or hydraulic proportional controls or automotive
controls. The shuttle valve must be controlled by a 2-line external signal, based on direction of motor
rotation, based on the following table:
Options THD1, THD2, THD7: pressure compensator configuration with electric BPD
A solenoid-switched valve ahead of the pressure compensator prevents operation in the deceleration
direction (when motor is running in pump mode). This is designed to prevent rapid or uncontrolled
deceleration while the vehicle/machine is slowing down. The solenoid valve must be controlled by an
external electric signal, based on direction of motor rotation, see the following table:
Options TH** – hydraulic two-position control for 51 (frame size 160, 250)
Circuit diagram – motor with two-position control TH**
L2 M4 M3 N
A
XA X4 X4 M1
n
max.
disp.
T2 T3
X1 X1 T1 T7 T8 (X3)
M5
XB
B M2
with without
Brake pressure Brake pressure L1
P001 837E
defeat defeat
Ports:
Pressure compensator
override bar, [psi]
setting range
PCOR start
130 370 [5370]
Hydraulic
two-position-
control
[1890]
[145 psi]
min. 10 bar
[510 psi]
Ramp < 10
[145]
max. 35 bar
min. max.
Displacement
P001 776E
Options E1B1, E2B1, E7B1 – electrohydraulic two-position control for 51-1 (frame size 060, 080, 110)
Circuit diagram – motor with EH two-position control E1B1, E2B1, E7B1
L2 N
A
n
min.
disp.
T3
T2
M5 M3
B
L1 M4 P001 780E
Displacement can be changed electrohydraulically under load from maximum displacement to minimum
displacement and vice versa, by using a built-in solenoid valve.
Control operation E1B1, E2B1, E7B1
Electrohydraulic
two-position control
Control voltage
12V
/24V
min max
Displacement
P001 870E
Options:
Solenoid off = max. displacement
Solenoid on = min. displacement
Pilot pressure for solenoid:
internal = low pressure
The graph shows the necessary servo pressure (= low pressure), which is needed to stroke the motor,
depending on high system pressure and the pump or motor mode.
20
[290]
10
[145] min. pilot pressure at all other
conditions motor and pump mode
in both directions
0
0 100 200 300 400
[1450] [2900] [4350] [5800]
System pressure bar [psi] P001 878E
Options E1A5, E2A5 – electrohydraulic two-position control for 51 (frame size 160, 250)
Circuit diagram – motor with control options: E1A5, E2A5
L2 M4 M3 N
A
M1
n
max.
disp.
T2 T3
T1 T7 T8
M5
B M2
L1 M8 M7 P100 180E
Ports:
Displacement can be changed electrohydraulically under load from maximum displacement to minimum
displacement and vice versa, by using a built-in solenoid valve.
Control operation E1A5, E2A5
Electrohydraulic
two-position control
Control voltage
12V
/24V
min max
Displacement
P001 870E
Options:
Solenoid off = max. displacement
Solenoid on = min. displacement
Pilot pressure for solenoid:
Options F1B1, F2B1 – electrohydraulic two-position control for 51-1 (frame size 060, 080, 110)
Circuit diagram – motor with control options: F1B1, F2B1
L2 N
A
n
min.
disp.
T3
T2
M5 M3
B
L1 M4 P001 867E
Ports:
Displacement can be changed electrohydraulically under load from maximum displacement to minimum
displacement and vice versa, by using a built-in solenoid valve.
Control operation F1B1, F2B1
Electrohydraulic
two-position control
Control voltage
12V
/24V
min max
Displacement
P001 871E
Options:
Solenoid off = min. displacement
Solenoid on = max. displacement
Pilot pressure for solenoid:
internal = low pressure
The graph shows the necessary servo pressure (= low pressure), which is needed to stroke the motor,
depending on high system pressure and the pump or motor mode.
10
[145] min. pilot pressure at all other
conditions motor and pump mode
in both directions
0
0 100 200 300 400
[1450] [2900] [4350] [5800]
System pressure bar [psi] P001 879E
Options F1A5, F2A5 – electrohydraulic two-position control for 51 (frame size 160, 250)
Circuit diagram – motor with control options: F1A5, F2A5
L2 M4 M3 N
A
M1
n
max.
disp.
T2 T3
T1 T7 T8
M5
B M2
L1 M8 M7 P001 874E
Ports:
Displacement can be changed electrohydraulically under load from maximum displacement to minimum
displacement and vice versa, by using a built-in solenoid valve.
Control operation F1A5, F2A5
Electrohydraulic
two-position control
Control voltage
12V
/24V
min max
Displacement
P001 871E
Options:
Solenoid off = min. displacement
Solenoid on = max. displacement
Pilot pressure for solenoid:
Options T1**, T2**, T7** – electrohydraulic two-position control for 51-1 (frame size 060, 080, 110)
Circuit diagram – motor with electrohydraulic two-position control T1**, T2**, T7**
L2 N
XB XA A
n
min.
disp.
T3 T3 T3
M3 M3 M3
B
with Electric with Hydraulic without
brake pressure brake pressure Brake pressure L1 M4
P001 784E
defeat defeat defeat
Ports:
Displacement can be changed electrohydraulically under load from minimum displacement to maximum
displacement and vice versa, by using a solenoid. When the solenoid is energized the motor has
maximum displacement and the pressure compensator does not function.
Solenoid not energized = minimum displacement
Solenoid energized = maximum displacement
Pressure Compensator Override (PCOR)
The control can be overridden by PCOR using high loop pressure. When the PCOR activates, the motor
displacement increases toward maximum. Pressure ramp from PCOR start pressure (with motor at
minimum displacement) until maximum displacement is reached is less than 10 bar [145 psi]. This
ensures optimal power utilization throughout the entire displacement range of the motor.
PCOR start pressure is adjustable from 130 to 370 bar [1890 to 5370 psi].
Pressure compensator
override bar, [psi]
setting range
Electrohydraulic
370 [5 370]
PCOR start
two-position-
control
[1890]
130
12V/24V
10 [145]
Ramp <
min. max.
Displacement
P001 872E
Option T*CA: pressure compensator configuration with hydraulic Brake Pressure Defeat
A shuttle valve ahead of the pressure compensator prevents operation in the deceleration direction
(when motor is running in pump mode). This is designed to prevent rapid or uncontrolled deceleration
while the vehicle/machine is slowing down.
Pressure compensator override with brake pressure defeat is mainly used in systems with pumps having
electric or hydraulic proportional controls or automotive controls.
The shuttle valve must be controlled by a 2-line external signal, based on direction of motor rotation, see
the following table:
Motor rotation High pressure port Control pressure on port* PCOR function
CW A XA yes
CW A XB no
CCW B XA no
CCW B XB yes
* Differencial control pressure between port XA/XB:
∆pmin = 0.5 bar [7 psi]
∆pmax = 50 bar [725 psi]
Options T*D1, T*D2, T* D7: pressure compensator configuration with electric BPD
A solenoid-switched valve ahead of the pressure compensator prevents operation in the deceleration
direction (when motor is running in pump mode). This is designed to prevent rapid or uncontrolled
deceleration while the vehicle/machine is slowing down.
The solenoid valve must be controlled by an external electric signal, based on direction of motor rotation,
see the following table:
P001751
Options T1**, T2** – electrohydraulic two-position control for 51 (frame size 160, 250)
Circuit diagram – motor with electrohydraulic two-position control T1**, T2**
L2 M4 M3 N
A
XA X4 X4
M1
n
max.
disp.
T2 T3
T1 T7 T8
M5
XB
B M2
with without
L1 P001 785E
Brake pressure Brake pressure
defeat defeat
Ports:
Displacement can be changed electrohydraulically under load from minimum displacement to maximum
displacement and vice versa, by using a solenoid. When the solenoid is energized the motor has
maximum displacement and the pressure compensator does not function.
Solenoid not energized = minimum displacement
Solenoid energized = maximum displacement
Pressure Compensator OverRide (PCOR)
The control can be overridden by PCOR using high loop pressure. When the PCOR activates, the motor
displacement increases toward maximum. Pressure ramp from PCOR start pressure (with motor at
minimum displacement) until maximum displacement is reached is less than 10 bar [145 psi]. This
ensures optimal power utilization throughout the entire displacement range of the motor.
PCOR start pressure is adjustable from 130 to 370 bar [1890 to 5370 psi].
Pressure compensator
override bar, [psi]
setting range
Electrohydraulic
370 [5 370]
PCOR start
two-position-
control
[1890]
130
12V/24V
10 [145]
min. max. Ramp <
Displacement
P001 872E
Option T*C0: pressure compensator configuration with hydraulic Brake Pressure Defeat
A shuttle valve ahead of the pressure compensator prevents operation in the deceleration direction
(when motor is running in pump mode). This is designed to prevent rapid or uncontrolled deceleration
while the vehicle/machine is slowing down. Pressure compensator override with brake pressure defeat is
mainly used in systems with pumps having electric or hydraulic proportional controls or automotive
controls.
The shuttle valve must be controlled by a 2-line external signal, based on direction of motor rotation, see
the following table:
Motor rotation High pressure port Control pressure on port* PCOR function
CW A XA no
CW A XB yes
CCW B XA yes
CCW B XB no
* Differencial control pressure between port XA/XB:
∆pmin = 0.5 bar [7 psi]
∆pmax = 50 bar [725 psi]
Options EP**, EQ** – electrohydraulic proportional control for 51 (all frame sizes)
Circuit diagram – motor with electrohydraulic proportional control EP**, EQ**
L2 M4 M3 N
A
M1
n
T4
max.
disp.
T5 T5
U7 U6 U7 U6 T2 T3
T6
T1 T7 T8
M5
XA XB
B M2
WITH WITHOUT
BRAKE PRESSURE BRAKE PRESSURE
DEFEAT DEFEAT
L1 M7 X1 M8 P001 786E
Ports:
Displacement can be changed under load in response to an electrical signal between maximum
displacement and minimum displacement and vice versa.
Control start = maximum displacement
Control end = minimum displacement
Control supply pressure (port X1)
pmin = 20 bar [290 psi]
pmax allowable = 70 bar [1015 psi]
setting range
J K
[1890] PCOR start
370 [5370]
High pressure Dp bar [psi]
setting range
Control start
50
85
130
Current mA
Ramp < 10 bar
15
50
[145 psi]
min max
Ramp
Connectors
Options EPA1, EQA1: pressure compensator configuration with Brake Pressure Defeat
A shuttle valve ahead of the pressure compensator prevents operation in the deceleration direction
(when motor is running in pump mode). This is designed to prevent rapid or uncontrolled deceleration
while the vehicle/machine is slowing down.
Pressure compensator override with brake pressure defeat is mainly used in systems with pumps having
electric or hydraulic proportional controls or automotive controls.
The shuttle valve must be controlled by a 2-line external signal, based on direction of motor rotation, see
the following table:
Options EPA2, EQA2: pressure compensator configuration without Brake Pressure Defeat
The pressure compensator override functions when the motor is running in motor mode as well as in
pump (deceleration) mode.
Options L1B1, L2B1, L7B1 – electrohydraulic proportional control for 51 (all frame sizes)
Circuit diagram – motor with electrohydraulic propor. control L1B1, L2B1, L7B1
L2 M4 M3 N
A
M1
n
max.
disp.
T2 T3
T1 T7 T8 M5
B M2
L1 P001 787E
Ports:
Displacement can be changed electrohydraulically under load in response to an electrical signal from
minimum displacement to maximum displacement and vice versa. The displacement changes
proportional to the electrical signal. The electrical signal must be a pulse-width modulated (PWM) signal,
(f = 100...200 Hz).
Control start = maximum displacement
Control end = minimum displacement
Control operation L1**, L2**, L7**
L7** L8**
1290 645
Control current (mA)
440 220
0 0
20% 100%
min max
Displacement
P001 777E
Solenoid plug face DIN 46350 (Supplied) AMP Junior Timer two-pin (Supplied)
2 1
A B
P001752 P001751
Solenoid data
Configuration Voltage Nominal Control current Connector
resistance 20 °C
Start End Max.
L1B1 DIN 46350
12 VDC 5.7 Ω 440 mA 1290 mA 1500 mA
L7B1 AMP Junior Timer
L2B1 24 VDC 21.3 Ω 220 mA 645 mA 750 mA DIN 46350
Options D7M1, D8M1 – electrohydraulic proportional control with PCOR and hydraulic BPD for 51 (all frame sizes)
Circuit diagram – motor with EH prop. control D7M1, D8M1
L2 M4 M3 N
A
XB XA
M1
n
T4
max.
disp.
U7
T6 T2 T3
T1
T7 T8
(M5)
X3
M7
B M2
L1 P001 869E
Ports:
Displacement can be changed electrohydraulically under load in response to an electrical signal from
minimum displacement to maximum displacement and vice versa. The displacement changes
proportional to the electrical signal. The electrical signal must be a pulse-width modulated (PWM) signal,
(f = 100...200 Hz).
Solenoid not energized = maximum displacement
Solenoid energized = minimum displacement
Servo pressure supply = external pressure at port X3
Min. pressure = 25 bar [360 psi]
Max. pressure = 50 bar [725 psi]
Pressure compensator
override
setting range
PCOR start
Electrohydr.
prop. control
370 bar D8M1 D7M1
[5370 psi]
(ratio 5:1)
320 640
[145 psi]
start-current
min max
Displacement
P001 873E
Options D7M1, D8M1: pressure compensator configuration with hydraulic Brake Pressure Defeat
A shuttle valve ahead of the pressure compensator prevents operation in the deceleration direction
(when motor is running in pump mode). This is designed to prevent rapid or uncontrolled deceleration
while the vehicle/machine is slowing down.
Pressure compensator override with brake pressure defeat is mainly used in systems with pumps having
electric or hydraulic proportional controls or automotive controls.
The shuttle valve must be controlled by a 2-line external signal, based on direction of motor rotation, see
the following table:
Motor rotation High pressure port Control pressure on port* PCOR function
CW A XA no
CW A XB yes
CCW B XA yes
CCW B XB no
* Differencial control pressure between port XA/XB:
∆pmin = 0.5 bar [7 psi]
∆pmax = 50 bar [725 psi]
A
M1
n
T4
max.
disp.
T5
T5
U7 U6 U7 U6 T2 T3
T6
T1 T7 T8
M5
XA XB
B M2
with without
Brake pressure Brake pressure L1 X1 M7 P001 788E
defeat defeat
Displacement can be changed in response to a hydraulic signal under load between maximum
displacement and minimum displacement and vice versa.
Control start = maximum displacement
Control end = minimum displacement
Control pressure (Port X1)
External = absolute pressure
Control ramp
From 100% to 20% displacement 7 bar [102 psi]
From 100% to 20% displacement 14 bar [203 psi]
power utilization throughout the entire displacement range of the motor. PCOR start pressure is
adjustable from 130 to 370 bar [1890 to 5370 psi].
Control Operation HS**
Pressure compensator Proportional
override control
A B C
Ramp
Motor rotation High pressure port Control pressure on port* PCOR function
CW A XA no
CW A XB yes
CCW B XA yes
CCW B XB no
* Differencial control pressure between port XA/XB:
∆pmin = 0.5 bar [7 psi]
∆pmax = 50 bar [725 psi]
A
M1
n
max.
disp.
T2 T3
T1 T7 T8 M5
B M2
L1 X1 M7 P001 880E
Displacement can be changed in response to a hydraulic signal under load between maximum
displacement and minimum displacement and vice versa.
Control start = maximum displacement
Control end = minimum displacement
Control pressure on port X1
External = absolute pressure
Proportional
control
A B C
Control start
min Displacement max version
P001 881E
Control ramp
From 100% to 20% displacement 7 bar [102 psi]
From 100% to 20% displacement 14 bar [203 psi]
Y W
Loop flushing
X shuttle valve
Charge pressure W
215.0
relief valve
[8.45] Gauge port “M4”
M4
88.5 System pressure max. angle
[3.48] 0.5625-18UNF-2B
[9/16 -18UNF-2B]
Case drain “L1”
1.0625-12UN-2B B A
[1 1/16 -12UN-2B] 23.8
]
[0.94
[8.21]
208.5
Y
70.0
[2.93]
74.5
]
[2.76 Gauge port “M2”
50.8
[2.00
[1.57].
70.0
40.0
0.875-14UNF-2B
[7/8 -14UNF-2B]
Gauge port “M1”
[2.93]
74.5
0.875-14UNF-2B
[7/8 -14UNF-2B]
Alternate position
Case drain “L2” Split flange boss “A”+”B”
1.0625-12UN-2B min. angle stop
[1 1/16 -12UN-2B] DN 19 typ II 40 MPa series
adjustment per ISO 6162 [SAE 0.75]
88.5 4 thread: 0.375-16UNC-2B
[3/8 -16UNC-2B]
[3.48] 19 [0.75] min.
260.1 max. full thread depth
[10.24 max.]
Y W
X
242.0
W
[9.53] Gauge port “M4”
M4
Y
[4.05]
103.0
47.0
[1.94]
47.0 [1.85
DN 19 typ II 40 MPa series ] 73.0
per ISO 6162 [SAE 0.75] [1.85 ]
4 thread: 0.375-16UNC-2B .0 [2.87
7 3
] Split flange boss “B”
[3/8 -16UNC-2B] [2.87
19 [0.75] min. DN 19 typ II 40 MPa series
full thread depth per ISO 6162 [SAE 0.75]
4 thread: 0.375-16UNC-2B
Gauge ports “M1”+”M2” [3/8 -16UNC-2B]
19 [0.75] min.
System pressure “A”+”B” full thread depth
0.5625-18UNF-2B
[9/16 -18UNF-2B] P001 790E
51V060 Proportional and Two Position Control, HZB1 (Side port on top, Axial port below)
Y 66
X [2.60
]
66
]
[2.60
Gauge port “M4”
217 Gauge port “M3”
[8.53] Servo pressure max. angle
Servo pressure min. angle 0.5625-18UNF-2B
Loop flushing 0.5625-18UNF-2B [9/16 -18UNF-2B]
[9/16 -18UNF-2B]
shuttle valve
Charge pressure W
relief valve
M4
Control start
88.5 adjustment
[3.48]
M3
L1
M1
0.5625-18UNF-2B
[2.00
[1.60]
41
[9/16 -18UNF-2B]
[2.93]
74.5
98 max.
M5
[9/16 -18UNF-2B]
[3.77]
96
L2
Alternate position
Case drain “L2” min. angle stop Control mounting U
1.0625-12UN-2B
adjustment surface
[1 1/16 -12UN-2B] Gauge port “M7” U M7
Control pressure Split flange boss “A”+”B”
0.5625-18UNF-2B DN 19 typ II 40 MPa series Shaft centerline
X1
88.5 [9/16 -18UNF-2B] per ISO 6162 [SAE 0.75]
[3.48]
[1.93]
4 thread: 0.375-16UNC-2B
49.0
294.0 [3/8 -16UNC-2B]
19 [0.75] min.
[11.56] full thread depth Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 70.0
]
[2.76
70.0
] 45.0
[2.76 .0 ]
Gauge port “M1”+”M2” 45 [1.77
]
System pressure “A”+”B” [1.77
X 0.5625-18UNF-2B
Gauge port “M4”
[9/16 -18UNF-2B]
Servo pressure max. angle
0.5625-18UNF-2B
263.0 [9/16 -18UNF-2B]
M3
[10.35]
W
M4
0
23.8 ]
[0.94
121.0
[4.77]
50.8 ]
[2.00
B
M4
W
0
A
Y
M5
[4.05]
103.0
L1
Supply pressure
[2.22]
Shuttle valve
56.0
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Split flange boss “A” Split flange boss “B”
DN 19 typ II 40 MPa series DN 19 typ II 40 MPa series
per ISO 6162 [SAE 0.75] per ISO 6162 [SAE 0.75]
L2 4 thread: 0.375-16UNC-2B 4 thread: 0.375-16UNC-2B
[3/8 -16UNC-2B] [3/8 -16UNC-2B]
19 [0.75] min. 19 [0.75] min.
full thread depth full thread depth
P001 965E
[5.75 ± 0.06]
146.0 ± 1.6
Z
Ø103.4
Ø44.45
Ø80.0
[4.07]
[1.75]
[3.15]
ØD
ØA
ØG
H Ø19.5 [0.77]
other side max
screw head space
12.45 18.0
[0.49] [0.71]
C 57.25 ± 0.2 57.25 ± 0.2
Coupling may not protrude [2.25 ± 0.01] [2.25 ± 0.01]
beyond this surface 146.0 ± 1.6
P001 809E
[5.75 ± 0.06]
Y W
Loop flushing
X shuttle valve
190.0
Charge pressure W
relief valve
[7.49]
Gauge port “M4”
M4
59.0 System pressure max. angle
[2.32] 0.5625-18UNF-2B
[9/16 -18UNF-2B]
Case drain “L1”
1.0625-12UN-2B
23.8
B A
[1 1/16 -12UN-2B] ]
[0.94
[8.21]
208.5
Y
[3.05]
70.0
77.5
]
[2.76
50.8
[1.57]
40.0
0.875-14UNF-2B
[7/8 -14UNF-2B]
Gauge port “M1”
[2.97]
75.5
0.875-14UNF-2B
[7/8 -14UNF-2B]
Alternate position
Case drain “L2” min. angle stop
1.0625-12UN-2B adjustment Split flange boss “A”+”B”
[1 1/16 -12UN-2B] DN 19 typ II 40 MPa series
90.0 per ISO 6162 [SAE 0.75]
4 thread: 0.375-16UNC-2B
[3.54] [3/8 -16UNC-2B]
234.1 max. 19 [0.75] min.
[9.22 max.] full thread depth
Y W
X
W
218.0
[8.57] Gauge port “M4”
M4
Y
[3.70]
94.0
47.0
[1.94]
]
47.0 [1.85
DN 19 typ II 40 MPa series ] 73.0
per ISO 6162 [SAE 0.75] [1.85 ]
[2.87
4 thread: 0.375-16UNC-2B 73.0
[3/8 -16UNC-2B] ] Split flange boss “B”
19 [0.75] min. [2.87
DN 19 typ II 40 MPa series
full thread depth per ISO 6162 [SAE 0.75]
4 thread: 0.375-16UNC-2B
Gauge ports “M1”+”M2” [3/8 -16UNC-2B]
19 [0.75] min.
System pressure “A”+”B” full thread depth
0.5625-18UNF-2B
[9/16 -18UNF-2B]
P001 791E
51D060 proportional and two position control, HZB1 (Side port on top, Axial port below)
M4
shuttle valve [9/16 -18UNF-2B]
Charge pressure
relief valve
Control start
59.0 adjustment
[2.32] W
M3
A
Y Gauge port “M1” Shuttle valve
0.5625-18UNF-2B
L1 System pressure “A” [9/16 -18UNF-2B]
0.5625-18UNF-2B
[3.05]
M1
77.5
[9/16 -18UNF-2B]
50.8 ]
[2.00
[1.60]
41.0
[9/16 -18UNF-2B]
M5
[3.89]
[3.77]
99.0
96.0
L2
U
Alternate position M7
Case drain “L2” min. angle stop Control mounting
1.0625-12UN-2B adjustment surface
[1 1/16 -12UN-2B] Gauge port “M7” U Shaft centerline
X1
Control pressure Split flange boss “A”+”B”
[1.93]
49.0
0.5625-18UNF-2B DN 19 typ II 40 MPa series
90.0 [9/16 -18UNF-2B] per ISO 6162 [SAE 0.75]
[3.54] 4 thread: 0.375-16UNC-2B
270.0 [3/8 -16UNC-2B] Control pressure port “X1”
19 [0.75] min. 0.5625-18UNF-2B
[10.64] full thread depth [9/16 -18UNF-2B]
Y 70.0
]
[2.76
70.0
] .0
[2.76 45
]
Gauge port “M1”+”M2” 45.0 [1.77
]
System pressure “A”+”B” [1.77
X 0.5625-18UNF-2B Gauge port “M4”
[9/16 -18UNF-2B] Servo pressure max. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
238.0
M3
[9.39]
W
M4
0
23.8 ]
[0.94
87.0
[3.45]
50.8 ]
[2.00
B
W
M4
A
0
Y
M5
Supply pressure
L1
[3.70]
94.0
Shuttle valve
[2.22]
56.0
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Split flange boss “A” Split flange boss “B”
DN 19 typ II 40 MPa series DN 19 typ II 40 MPa series
per ISO 6162 [SAE 0.75] per ISO 6162 [SAE 0.75]
4 thread: 0.375-16UNC-2B 4 thread: 0.375-16UNC-2B
L2 [3/8 -16UNC-2B] [3/8 -16UNC-2B]
19 [0.75] min. 19 [0.75] min.
full thread depth full thread depth
P001 966E
E 6.0
[0.24] Ø14.0 ± 0.2
B [0.55 ± 0.01]
R1.6
[2.23]
56.57
[0.06] .0
10
[5.91 ± 0.06]
Ø1 33]
Ø125.0 - 0.063
150.0 ± 1.6
[4.921 - 0.002]
Z .
Ø44.45
[ 4
Ø85.0
[3.35]
[1.75]
ØD
ØA
[2.23]
56.57
ØG
Ø19.5 [0.77]
other side max.
9.0 17.0 screw head space
[0.35] [0.67]
C 32.5 56.57 56.57
Coupling may not protrude [1.28] [2.23] [2.23]
beyond this surface 150.0 ± 1.6
[5.91 ± 0.06] P001 810E
Cartridge flange
51C060-1 two-position control, N1NN (Side port on top, Axial port below)
Y W
Loop flushing
X shuttle valve
Charge pressure W
130.0
[5.13] relief valve
Gauge port “M4”
M4
System pressure max. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Case drain “L1”
1.0625-12UN-2B
[1 1/16 -12UN-2B] B A
23.8
]
[0.94
[8.21]
208.5
Y
L1
70
]
[2.76
50.8
[1.57]
70
39.0 39.0
40.0
0.875-14UNF-2B
Gauge port “M1” [7/8 -14UNF-2B]
System pressure “A”
0.875-14UNF-2B
[3.91]
99.4
[7/8 -14UNF-2B]
Speed pick-up
Alternate position
Case drain “L2” min. angle stop Split flange boss “A”+”B”
1.0625-12UN-2B adjustment
50.0 DN 19 typ II 40 MPa series
[1 1/16 -12UN-2B] per ISO 6162 [SAE 0.75]
[1.97] 4 thread: 0.375-16UNC-2B
174.3 max. [3/8 -16UNC-2B]
[6.86 max.] 19 [0.75] min.
full thread depth
Y W
X
W
158.0
[6.21] Gauge port “M4”
M4
Y
L1
]
49.0
51C060 proportional and two-position control, HZB1 (Side port on top, Axial port below)
Y 66.0
Gauge port “M4”
X [2.60
] Servo pressure max. angle
66.0 0.5625-18UNF-2B
]
[2.60 [9/16 -18UNF-2B]
132.0 Gauge port “M3”
[5.21]
Servo pressure min. angle
W
Loop Flushing 0.5625-18UNF-2B
M4
shuttle valve [9/16 -18UNF-2B]
Charge pressure
relief valve
Control Start
[1 1/16 -12UN-2B]
[6.77]
Supply pressure
172.0
A Shuttle valve
L1 Y Gauge port “M1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
System pressure “A”
M1
0.5625-18UNF-2B
50.8 ]
[9/16 -18UNF-2B]
[2.00
[1.60]
[1.54] [1.54]
41.0
39.0 39.0
[9/16 -18UNF-2B]
[3.89]
[3.77]
99.0
96.0
L2
Alternate position
Case drain port “L2” min. angle stop Control mounting
1.0625-12UN-2B
adjustment surface
U
[1 1/16 -12UN-2B]
Gauge port “M7” U M7
Control pressure Split flange boss “A”+”B”
50.0 0.5625-18UNF-2B DN 19 typ II 40 MPa series Shaft centerline
X1
[1.97] [9/16 -18UNF-2B] per ISO 6162 [SAE 0.75]
4 thread: 0.375-16UNC-2B
[1.93]
49.0
209.0 [3/8 -16UNC-2B]
[8.24] 19 [0.75] min.
full thread depth
Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 70.0 ]
[2.76
70.0 ]
[2.76 .0 45.0
]
Gauge port “M1”+”M2” 45 [1.77
]
System pressure “A”+”B” [1.77
X 0.5625-18UNF-2B
Gauge port “M4”
Servo pressure max. angle
[9/16 -18UNF-2B]
0.5625-18UNF-2B
[9/16 -18UNF-2B]
179.0
W
M3
[7.03]
M4
0
23.8 ]
[0.94
W
B
50.8 ]
M4
[2.00
A
Y
0
L1
M5
Supply pressure
Shuttle valve
0.5625-18UNF-2B
[2.22]
56.0
P001 967E
R1.6
[0.06]
Ø160.0 - 0.025
[6.299 - 0.001]
M3
Z
Ø44.45
Ø134.0
Ø106.0
Ø90.0
[1.75]
[5.28]
[4.17]
[3.54]
ØD
ØA
H
ØG
[3.13]
79.5
Clea
min rance
.Ø
[9.53242.0
]
Y W
Loop flushing
X shuttle valve
Charge pressure
235.0 relief valve W
[9.27]
Gauge port “M4”
M4
94.0 System pressure max. angle
[3.69] 0.5625-18UNF-2B
[9/16 -18UNF-2B]
Case drain “L1”
1.0625-12UN-2B 6
[8.62]
27.7 ]
218.9
[1 1/16 -12UN-2B]
B A
[1.09
Y
[3.37]
76.0
85.5
[2.99
[2.25
[1.76]
45.0
]
19° [2.99 1.0625-12UNF-2B
[1 1/16 -12UNF-2B]
Gauge port “M1”
System pressure “A”
[3.15]
80.0
1.0625-12UNF-2B
[4.20]
106.7
[1 1/16 -12UNF-2B]
Alternate position
Case drain “L2” min. angle stop Split flange boss “A”+”B”
1.0625-12UN-2B DN 25 typ II 40 MPa series
[1 1/16 -12UN-2B] adjustment
per ISO 6162 [SAE 1.00]
93.7 4 thread: 0.4375-14UNC-2B
[3.69] [7/16 -14UNC-2B]
278.2 max. 27 [1.06] min.
[10.95 max.] full thread depth
Y W
X
261.0 W
[10.28]
Gauge port “M4”
M4
Y
[4.58]
116.0
]
DN 25 typ II 40 MPa series 50.0 [1.97
] 79.0
per ISO 6162 [SAE 1.00] [1.97 ]
4 thread: 0.4375-14UNC-2B [3.11
[7/16 -14UNC-2B] 79.0
]
27 [1.06] min. [3.11
Split flange boss “B”
full thread depth
DN 25 typ II 40 MPa series
per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
Gauge ports “M1”+”M2” [7/16 -14UNC-2B]
27 [1.06] min.
System pressure “A”+”B” full thread depth
0.5625-18UNF-2B
[9/16 -18UNF-2B] P001 793E
51V080 Proportional and Two-Position Control, HZB1 (Side port on top, Axial port below)
Gauge port “M4”
Servo pressure max. angle
Y 74.0
]
0.5625-18UNF-2B
[9/16 -18UNF-2B]
[2.91
X 74.0
] W
[2.91
M4
Gauge port “M3”
235.0 Servo pressure min. angle
[9.27] 0.5625-18UNF-2B
Loop flushing [9/16 -18UNF-2B]
shuttle valve
Charge pressure W
relief valve Control start
94.0 adjustment Supply pressure
[3.69] Shuttle valve
M3
57.1 ]
[2.25
[1.76]
45.0
19°
M5
[4.20]
107.0
[4.00]
102.0
U
Alternate position
M7
Case drain “L2”
1.0625-12UN-2B min. angle stop Control Mounting
[1 1/16 -12UN-2B] adjustment Gauge port “M7” Surface Shaft centerline
X1
Control pressure U Split flange boss “A”+”B”
[1.93]
49.0
0.5625-18UNF-2B DN 25 typ II 40 MPa series
93.7 [9/16 -18UNF-2B]
[3.69] per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
318.0 [7/16 -14UNC-2B] Control pressure port “X1”
[12.52] 27 [1.06] min. 0.5625-18UNF-2B
full thread depth [9/16 -18UNF-2B]
Y 81.0
]
[2.01
81.0 51.0 Gauge port “M4”
]
[2.01 1.0 [2.01
]
Servo pressure max. angle
Gauge port “M1”+”M2” 5
]
System pressure “A”+”B” [2.01 0.5625-18UNF-2B
[9/16 -18UNF-2B]
X 0.5625-18UNF-2B
[9/16 -18UNF-2B]
W
M4
282.0
M3
[11.09]
134.0
[5.26] 6 W
27.7 ]
[1.09
57.1 ]
[2.25
B
M4
Supply pressure
5
A
Shuttle valve
Y 0.5625-18UNF-2B
M5
[9/16 -18UNF-2B]
[4.58]
116.0
[2.39]
61.0
P001 794E
B
O-ring 3.00x116.00 FPM
[0.12x4.57]
R3.0
[0.12]
[2.25]
4x Ø14.5 ± 0.2
57.25
Ø126.975 ± 0.025
[0.57 ± 0.01]
[4.999 ± 0.001]
[5.91 ± 0.06]
150.0 ± 1.6
Z
Ø44.0
[1.75]
Ø80.0
[3.15]
ØD
ØA
[2.25]
57.25
Ø19.5 [0.77]
ØG
H
other side max.
screw head space
12.0 20.0
[0.49] [0.79]
C 57.25 57.25
[2.25] [2.25]
Coupling may not protrude
beyond this surface 150.0 ± 1.6
[5.91 ± 0.06] P001 812E
Y W
Loop flushing
X shuttle valve
Charge pressure
211.0 relief valve W
[8.33]
Gauge port “M4”
M4
System pressure max. angle
70.0 0.5625-18UNF-2B
[2.75] [9/16 -18UNF-2B]
Case drain “L1”
1.0625-12UN-2B
6
[8.62]
218.9
Y
76.0
[3.44]
87.5
[1.76]
45.0
]
19° [2.99 1.0625-12UNF-2B
[1 1/16 -12UNF-2B]
Gauge port “M1”
[3.01]
76.5
[1 1/16 -12UNF-2B]
Alternate position
Case drain “L2” min. angle stop Split flange boss “A”+”B”
1.0625-12UN-2B adjustment DN 25 typ II 40 MPa series
[1 1/16 -12UN-2B] per ISO 6162 [SAE 1.00]
109.8 4 thread: 0.4375-14UNC-2B
[4.32] [7/16 -14UNC-2B]
27 [1.06] min.
252.7 max. full thread depth
[9.95 max.]
W
Y
X
W
237.0
[9.33] Gauge port “M4”
M4
Y
[4.40]
112.0
]
DN 25 typ II 40 MPa series 50.0 [1.97
] 79.0
per ISO 6162 [SAE 1.00] [1.97 ]
4 thread: 0.4375-14UNC-2B
9 .0 [3.11
[7/16 -14UNC-2B] 7
]
27 [1.06] min. [3.11 Split flange boss “B”
full thread depth DN 25 typ II 40 MPa series
per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
[7/16 -14UNC-2B]
Gauge ports “M1”+”M2” 27 [1.06] min.
System pressure “A”+”B” full thread depth
0.5625-18UNF-2B
[9/16 -18UNF-2B] P001 795E
51D080 Proportional and two position control, HZB1 (Side port on top, Axial port below)
Y 74.0
]
[2.91
X 74.0
]
[2.91
Gauge port “M4”
211.0 Gauge port “M3”
Servo pressure max. angle
[8.33] Servo pressure min. angle 0.5625-18UNF-2B
Loop flushing 0.5625-18UNF-2B [9/16 -18UNF-2B]
shuttle valve [9/16 -18UNF-2B]
Charge pressure W
M4
relief valve
66.65 Control start
[2.62] adjustment
W
M3
[7.19]
183.0
Y System pressure “A”
0.5625-18UNF-2B Supply pressure
[9/16 -18UNF-2B]
M1
[3.44]
Shuttle valve
87.5
0.5625-18UNF-2B
57.1 ]
[2.25
[1.76]
[9/16 -18UNF-2B]
45.0
19°
M5
[4.00]
102.0
[4.20]
107.0
Alternate position U
Case drain “L2” Control mounting M7
1.0625-12UN-2B min. angle stop Gauge port “M7” surface
[1 1/16 -12UN-2B] adjustment Control pressure
0.5625-18UNF-2B U Split flange boss “A”+”B” Shaft centerline
X1
109.8 [9/16 -18UNF-2B] DN 25 typ II 40 MPa series
[1.93]
[4.32] per ISO 6162 [SAE 1.00]
49.0
294.0 4 thread: 0.4375-14UNC-2B
[11.58] [7/16 -14UNC-2B]
27 [1.06] min.
full thread depth Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
81.0
]
[3.19
81.0
] 51
[3.19 ]
Gauge port “M1”+”M2” 51 [2.01 Gauge port “M4”
]
System pressure “A”+”B” [2.01 Servo pressure max. angle
0.5625-18UNF-2B 0.5625-18UNF-2B
[9/16 -18UNF-2B]
X [9/16 -18UNF-2B]
258.0
W
M3
M4
[10.15]
96.0
[3.80]
6
27.7 ] W
[1.09
57.1 ]
[2.25
B
M4
5
A
Y Supply pressure
M5
Shuttle valve
0.5625-18UNF-2B
[4.40]
112.0
[9/16 -18UNF-2B]
Split flange boss “A”
[2.39]
61.0
P001 796E
R1.6
[0.06] 4x Ø14.0 ± 0.2
[2.5]
63.6
[0.55 ± 0.01]
Ø140.0 - 0.063
[5.512 - 0.002]
.0
[6.61 ± 0.06]
168.0 ± 1.6
10
Z ∅45.0
[1.75] Ø1 .33]
[4
ØD
ØA
ØG
[2.5]
63.6
H
10.0 19.0
Ø19.5 [0.77]
[0.39] [0.75]
other side max.
C 32.1 63.6 63.6 screw head space
[1.26] [2.5] [2.5]
Coupling may not protrude
beyond this surface 168.0 ± 1.6
[6.61 ± 0.06] P001 813E
Cartridge flange
51C080-1 two-position control, N1NN (Side port on top, Axial port below)
Y W
Loop flushing
X shuttle valve
Charge pressure
133.0 relief valve W
[5.24]
Gauge port “M4”
M4
System pressure max. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Case drain “L1”
1.0625-12UN-2B
[1 1/16 -12UN-2B] 6
[8.62]
27.7 ]
218.9
B A
[1.09
L1
Y
76.0
57.1 ]
]
[2.25
[2.99
[1.77]
[1.77]
45.0
45.0
76.0
2
1.0625-12UNF-2B
45.0
[1 1/16 -12UNF-2B]
Speed pick-up
W
Y
X
W
159.0
[6.25] Gauge port “M4”
M4
Y
2
]
53.0
51C080 proportional and two-position control, HZB1 (Side port on top, Axial port below)
Y 74.0
]
[2.91
74.0
]
[2.91
X Gauge port “M3”
Gauge port “M4”
Servo pressure max. angle
Servo pressure min. angle 0.5625-18UNF-2B
133.0 0.5625-18UNF-2B [9/16 -18UNF-2B]
[9/16 -18UNF-2B]
[5.24]
Loop flushing
shuttle valve
W
48.0
M4
Charge pressure Control start
[1.98]
relief valve adjustment
M3
Y W
L1
Supply pressure
M1
Shuttle valve
57.1 ]
45.0
45.0
[9/16 -18UNF-2B]
5
[1.09
45.0
107.0
[9/16 -18UNF-2B]
Speed pick-up
Alternate position Control mounting
Case drain “L2”
1.0625-12UN-2B
Gauge port “M7”
U
surface U
[1 1/16 -12UN-2B] Control pressure Split flange boss “A”+”B”
0.5625-18UNF-2B M7
[9/16 -18UNF-2B] DN 25 typ II 40 MPa series
min. angle stop per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B Shaft centerline
X1
adjustment
215.0 [7/16 -14UNC-2B]
[1.93]
27 [1.06] min. 49.0
[8.45]
full thread depth
Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 81.0
]
[3.19
81.0
[3.19
] 51.0
]
51.0 [2.01
Gauge port “M1”+”M2” ]
[2.01
System pressure “A”+”B” Gauge port “M4”
0.5625-18UNF-2B
X [9/16 -18UNF-2B]
Servo pressure max. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
179.0
W
M3
[7.07]
M4
6
27.7 ]
[1.09 B
M4
57.1 ]
W
[2.25
A
Y
5
L1
M5
Supply pressure
Shuttle valve
Split flange boss “A” 0.5625-18UNF-2B
[2.39]
61.0
[9/16 -18UNF-2B]
19° DN 25 typ II 40 MPa series Split flange boss “B”
per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B DN 25 typ II 40 MPa series
[7/16 -14UNC-2B] per ISO 6162 [SAE 1.00]
27 [1.06] min. 4 thread: 0.4375-14UNC-2B
full thread depth [7/16 -14UNC-2B]
27 [1.06] min.
full thread depth
P001 798E
[3.33]
84.5
R1.6
[0.06]
Ø190.0 - 0.029
[7.48 - 0.001]
M3
Z
Ø44.45
Ø108.0
Ø112.0
Ø143.0
Ø90.0
[1.75]
[4.25]
[4.41]
[3.54]
[5.71]
ØA
ØD
28.0
ØG
[1.10]
[3.35]
84.5
Clea
min rance
.Ø
[10.5267.5
3]
Y W
Loop flushing
X shuttle valve
Charge pressure
254.0
relief valve W
[10.01]
Gauge port “M4”
M4
System pressure max. angle
101.0 0.5625-18UNF-2B
[3.98] [9/16 -18UNF-2B]
[9.16]
[1 1/16 -12UN-2B] 27.7 ] 232.6
[1.09
B A
Y
[3.43]
87.0
57.1 ]
[2.25
77.0
48.0
2
]
19° [3.03 System pressure “B”
77.0 1.0625-12UNF-2B
]
[3.03 [1 1/16 -12UNF-2B]
Gauge port “M1”
[3.54]
90.0
1.0625-12UNF-2B
[1 1/16 -12UNF-2B]
Alternate position
Case drain “L2” min. angle stop
Split flange boss “A”+”B”
1.0625-12UN-2B adjustment
[1 1/16 -12UN-2B] DN 25 typ II 40 MPa series
per ISO 6162 [SAE 1.00]
101.0 4 thread: 0.4375-14UNC-2B
[3.98] [7/16 -14UNC-2B]
143.0 27 [1.06] min.
[5.63] full thread depth
301.2 max.
[11.82 max.]
Y W
X
281.0
[11.05]
W
Gauge port “M4”
M4
Y
2
[4.74]
121.0
51V110 Proportional and Two-Position Control, HZB1 (Side port on top, Axial port below)
Y 77.0
]
[3.03
X 77.0
]
[3.03
Gauge port “M3” Gauge port “M4”
254.0 Servo pressure min. angle Servo pressure max. angle
[10.01] 0.5625-18UNF-2B 0.5625-18UNF-2B
Loop flushing [9/16 -18UNF-2B] [9/16 -18UNF-2B]
shuttle valve
Charge pressure W
relief valve
M4
101.0 Control start
[3.98] adjustment
Case drain “L”
M3
1.0625-12UN-2B
[1 1/16 -12UN-2B]
W
A
[7.30]
185.0
Y
Supply pressure
Shuttle valve
[3.43]
M1
87.0
[9/16 -18UNF-2B]
[4.00]
103.0
Alternate position
U
Case drain “L2” min. angle stop Control mounting M7
1.0625-12UN-2B adjustment Gauge port “M7” surface
[1 1/16 -12UN-2B]
Control pressure U Shaft centerline
X1
Split flange boss “A”+”B”
0.5625-18UNF-2B
101.0
[1.93]
DN 25 typ II 40 MPa series
49.0
[9/16 -18UNF-2B]
[3.98] per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
143.0 [7/16 -14UNC-2B]
[5.63] Control pressure port “X1”
27 [1.06] min.
337.0 full thread depth 0.5625-18UNF-2B
[13.25] [9/16 -18UNF-2B]
Y 80.0
]
[3.15
80.0
] 50.0
[3.15 .0 ]
50 [1.97
]
[1.97
Gauge port “M1”+”M2”
X System pressure “A”+”B”
0.5625-18UNF-2B
Gauge port “M4”
Servo pressure max. angle
[9/16 -18UNF-2B] 0.5625-18UNF-2B
[9/16 -18UNF-2B]
M3
300.0
[11.8] BA W
M4
134.0
6
[5.27] 27.7 ]
[1.09
57.1 ]
[2.25
M4
W
5
Y
M5
[4.74]
121.0
Supply pressure
Shuttle valve
Split flange boss “A”
[2.53]
0.5625-18UNF-2B
64.0
P001 800E
F Speed pick-up
E
Ø20.5 ± 0.2
B [0.81 ± 0.01]
O-ring 3.00x142.00 FPM
[0.12x5.59]
[3.18 ± 0.01]
80.8 ± 0.2
R3.0
[0.12]
Ø152.375 ± 0.025
[5.999 ± 0.001]
[7.87 ± 0.07]
200.0 ± 1.8
Z
Ø128.1
Ø100.0
[5.04]
[3.94]
Ø55.0
[2.17]
ØD
ØA
[3.18 ± 0.01]
80.8 ± 0.2
ØG
H
Ø30.0 [1.18]
other side max.
screw head space
12.45 22.0
[0.49] [0.87] 80.8 ± 0.2 80.8 ± 0.2
C [3.18 ± 0.01] [3.18 ± 0.01]
Loop flushing Y W
shuttle valve
X
Charge pressure
relief valve
223.0 W
[8.77]
Gauge port “M4”
M4
69.05 System pressure max. angle
[2.72] 0.5625-18UNF-2B
[9/16 -18UNF-2B]
Case drain “L1”
1.0625-12UN-2B
6
27.7 ]
[9.16]
232.8
[1 1/16 -12UN-2B]
[1.09
B A
Y
[3.68]
93.5
57.1 ]
[2.25
77.0
[1.92]
49.0
]
[3.03
2
19° 77.0
]
[3.03 Gauge port “M2”
Gauge port “M1” System pressure “B”
[3.48]
1.0625-12UNF-2B
88.5
1.0625-12UNF-2B
[1 1/16 -12UNF-2B]
Alternate position
min. angle stop
Case drain “L2” Split flange boss “A”+”B”
1.0625-12UN-2B adjustment
DN 25 typ II 40 MPa series
[1 1/16 -12UN-2B] per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
107.05 [7/16 -14UNC-2B]
[4.21] 27 [1.06] min.
268.2 max. full thread depth
[10.56 max.]
Y W
X
249.0 W
[9.81]
Gauge port “M4”
M4
Y
2
[4.99]
127.0
[2.27]
58.0
50.0
]
50.0 [1.97
Split flange boss “A” ]
[1.97 80.0
DN 25 typ II 40 MPa series ]
[3.15
per ISO 6162 [SAE 1.00] 80.0
]
4 thread: 0.4375-14UNC-2B [3.15 Split flange boss “B”
[7/16 -14UNC-2B]
27 [1.06] min. DN 25 typ II 40 MPa series
full thread depth per ISO 6162 [SAE 1.00]
Gauge ports “M1”+”M2” 4 thread: 0.4375-14UNC-2B
[7/16 -14UNC-2B]
System pressure “A”+”B” 27 [1.06] min.
0.5625-18UNF-2B full thread depth
[9/16 -18UNF-2B]
P001 801E
51D110 proportional and two position control, HZB1 (Side port on top, Axial port below)
Y 77.0
]
[3.03
X 77.0
]
[3.03
Gauge port “M4”
222.0 Gauge port “M3” Servo pressure max. angle
[8.75] Servo pressure min. angle 0.5625-18UNF-2B
Loop flushing 0.5625-18UNF-2B [9/16 -18UNF-2B]
[9/16 -18UNF-2B]
shuttle valve
Charge pressure W
relief valve
M4
69.05 Control start
[2.72] adjustment
M3
Shuttle valve
M1
0.5625-18UNF-2B
57.1 ]
[2.25
[9/16 -18UNF-2B]
49.0
5
0.5625-18UNF-2B
6 Gauge port “M1” Gauge port “M2”
27.7 ] [9/16 -18UNF-2B]
[1.09 System pressure “A” System pressure “B”
0.5625-18UNF-2B 0.5625-18UNF-2B
[3.48]
88.5
Alternate position
Case drain “L2” min. angle stop Gauge port “M7”
Control mounting
surface
U
1.0625-12UN-2B Control pressure
[1 1/16 -12UN-2B]
adjustment
0.5625-18UNF-2B U Split flange boss “A”+”B”
M7
[9/16 -18UNF-2B] DN 25 typ II 40 MPa series
107.05
per ISO 6162 [SAE 1.00] Shaft centerline
X1
[4.21]
305.0 4 thread: 0.4375-14UNC-2B
[1.93]
49.0
[12.00] [7/16 -14UNC-2B]
27 [1.06] min.
full thread depth
Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 80.0
]
[3.15
80.0
[3.15
] 50.0
]
50.0 [1.97
]
Gauge port “M1”+”M2” [1.97
System pressure “A”+”B”
0.5625-18UNF-2B Gauge port “M4”
X [9/16 -18UNF-2B] Servo pressure max. angle
0.5625-18UNF-2B
268.0 [9/16 -18UNF-2B]
M3
[10.54]
W
BA
M4
111.0
[4.35]
6
27.7 ]
[1.09
57.1 ]
[2.25
M4
5
Y W
M5
[4.94]
125.0
Supply pressure
Split flange boss “A” Shuttle valve
[2.53]
64.0
P001 802E
X Speed pick-up
Mounting flange surface
flange 160 B4 HL
per ISO 3019/2
F
E 13.5
[0.53]
B
Ø18.0 ± 0.2
R2.5 [0.71 ± 0.01]
[2.78]
70.7
[0.10]
Ø160.0 - 0.063
[6.299 - 0.002]
[7.48 ± 0.07]
Z
190.0 ± 1.8
Ø116.0
Ø55.0
[4.57]
[2.17]
ØA
ØD
H
[2.78]
ØG
70.7
Ø30.0 [1.18]
other side max.
screw head space
9.0 22.0
[0.35] [0.87]
70.7 70.7
C 40.3 [2.78] [2.78]
Coupling may not protrude [1.59]
190.0 ± 1.8
beyond this surface [7.48 ± 0.07] P001 816E
Cartridge flange
51C110-1 two-position control, N1NN (Side port on top, Axial port below)
Y W
Loop flushing
X shuttle valve
Charge pressure
relief valve
W
140.0
[5.51] Gauge port “M4”
M4
System pressure max. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
B A
[1.09
L1
Y
57.1 ]
[2.25
77.0
[1.92]
[1.89]
49.0
48.0
]
[3.03
2
1.0625-12UNF-2B
[1 1/16 -12UNF-2B]
Speed pick-up
Alternate position
Case drain “L2” min. angle stop
1.0625-12UN-2B Split flange boss “A”+”B”
adjustment
[1 1/16 -12UN-2B] DN 25 typ II 40 MPa series
48.0 per ISO 6162 [SAE 1.00]
[1.89] 4 thread: 0.4375-14UNC-2B
185.3 max. [7/16 -14UNC-2B]
27 [1.06] min.
[7.3 max.] full thread depth
W
166.0
[6.55] Gauge port “M4”
System pressure max. angle
M4
0.5625-18UNF-2B
[9/16 -18UNF-2B]
6
27.7 ]
[1.09
B A
57.1 ]
[2.25
L1
2
[2.27]
50.0
]
19° DN 25 typ II 40 MPa series 50.0 [1.97
per ISO 6162 [SAE 1.00] ]
4 thread: 0.4375-14UNC-2B [1.97 80.0
]
[7/16 -14UNC-2B] [3.15
80.0
27 [1.06] min. ] Split flange boss “B”
full thread depth [3.15
DN 25 typ II 40 MPa series
per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
Gauge ports “M1”+”M2” [7/16 -14UNC-2B]
27 [1.06] min.
System pressure “A”+”B” full thread depth
0.5625-18UNF-2B P001 803E
[9/16 -18UNF-2B]
51C110 proportional and two-position control, HZB1 (Side port on top, Axial port below)
Y 77.0
]
[3.03
77.0
]
[3.03
X Gauge port “M4”
Servo pressure max. angle
Gauge port “M3” 0.5625-18UNF-2B
140.0 [9/16 -18UNF-2B]
Servo pressure min. angle
[5.50] 0.5625-18UNF-2B
Loop flushing [9/16 -18UNF-2B] W
shuttle valve
M4
48.0
Charge pressure [1.89] Control start
relief valve adjustment
M3
[7.30] max.
185.0 max.
A
[1 1/16 -12UN-2B]
Y
L1
Supply pressure
Gauge port “M2” Shuttle valve
M1
0.5625-18UNF-2B
System pressure “B”
57.1 ]
[9/16 -18UNF-2B]
[2.25
[1.91]
N
6 0.5625-18UNF-2B
27.7 ] [9/16 -18UNF-2B] Gauge port “M1”
[1.09
[4.53] max.
115.0 max.
[9/16 -18UNF-2B]
L2
Speed pick-up
Alternate position
U
Control mounting
Case drain “L2” Gauge port “M7” M7
min. angle stop surface
Control pressure
1.0625-12UN-2B
[1 1/16 -12UN-2B] adjustment 0.5625-18UNF-2B U Split flange boss “A”+”B” Shaft centerline
[9/16 -18UNF-2B]
X1
DN 25 typ II 40 MPa series
[1.93]
per ISO 6162 [SAE 1.00]
49.0
221.0 4 thread: 0.4375-14UNC-2B
[8.71] [7/16 -14UNC-2B]
27 [1.06] min.
full thread depth Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 80.0
]
[3.15
80.0
] 50.0
[3.15 ]
50.0 [1.97
]
Gauge port “M1”+”M2” [1.97
Gauge port “M4”
System pressure “A”+”B”
X 0.5625-18UNF-2B
[9/16 -18UNF-2B]
Servo pressure max. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
M3
185.0
[7.29] BA W
M4
6
27.6 ]
[1.09
M4
W
57.1 ]
[2.25
Y
5
M5
Supply pressure
Shuttle valve
Split flange boss “A” 0.5625-18UNF-2B
[2.53]
64.0
P001 804E
Ø22.0 ± 0.3
[3.64]
R2.0
92.5
[0.87 ± 0.01]
[0.10]
Ø200.0 - 0.029
[7.874 - 0.001]
Z
M3
Ø160.0
Ø112.2
Ø136.0
Ø55.0
[2.17]
[6.30]
[4.42]
[5.35]
ØA
ØD
ØG
H
[3.64]
92.5
Clea
min rance
.Ø
[11.5293.5
6]
C 121.3
Coupling may not protrude [4.78]
125.0 125.0
beyond this surface [4.92] [4.92]
Case drain “L1”
287.9
1.0625-12UN-2B
[1 1/16 -12UN-2B] 11.2 20.0 [11.33]
[0.44] [0.79] P001 817E
Y 84.0
]
[3.31
84.0
X [3.31
]
M4
[4.47] adjustment
Case drain “L1”
M3
1.3125-12UN-2B
[1 5/16-12UN-2B] A
W
[8.08]
205.0
Y
Supply pressure
L1
[3.82]
M1
97.0
0.5625-18UNF-2B
19° [9/16 -18UNF-2B] 0.5625-18UNF-2B
M5
6
27.7 ] System pressure “A”
[1.09 0.5625-18UNF-2B
[3.82]
[4.37]
111.0
97.0
[4.94]
125.0
L2 [9/16 -18UNF-2B]
Alternate position U
Case drain “L2” Control mounting
min. angle stop Gauge port “M7”
M7
1.3125-12UN-2B surface
[1 5/16-12UN-2B] adjustment Control pressure
0.5625-18UNF-2B
U Split flange boss “A”+”B” Shaft centerline
X1
114.0 [9/16 -18UNF-2B] DN 25 typ II 40 MPa series
[1.93]
[4.47] per ISO 6162 [SAE 1.00]
49.0
376.0 4 thread: 0.4375-14UNC-2B
[14.82] [7/16 -14UNC-2B]
27 [1.06] min. Control pressure port “X1”
full thread depth
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 91.0
]
[3.58
91.0 .0
] 60
[3.58 .0 ]
60 [2.36
]
[2.36
Gauge port “M1”+”M2”
X System pressure “A”+”B” Gauge port “M4”
0.5625-18UNF-2B Servo pressure max. angle
[9/16 -18UNF-2B] 0.5625-18UNF-2B
[9/16 -18UNF-2B]
M3
313.0
[12.34] B A
W
6
27.7 ]
M4
165.0 [1.09
[6.51]
57.1 ]
[2.25
5
W
M4
Y
[5.68]
144.0
L1
M5
Supply pressure
Split flange boss “A” Shuttle valve
[2.52]
0.5625-18UNF-2B
64.0
P001 805E
X Z
Mounting flange surface
flange 152-4 (SAE "D")
per ISO 3019/1
F
E Speed pick-up
B
Ø30.0 [1.18]
O-ring 3.00x142.00 FPM other side max.
[0.12x5.59] screw head space
R3.0
[0.12]
[3.18]
80.8
Ø152.375 ± 0.025
[5.999 ± 0.001]
[7.87 ± 0.07]
200.0 ± 1.8
Z
Ø100.0
[3.94]
Ø55.0
[2.17]
ØA
ØD
ØG
[3.18]
80.8
H Ø20.5 ± 0.2
[0.81 ± 0.01]
12.45 22.0
[0.49] [0.87]
80.8 80.8
C [3.18] [3.18]
Coupling may not protrude 200.0 ± 1.8
beyond this surface [7.87 ± 0.07] P001 818E
Y 84.0
]
[3.31
X 84.0
]
[3.31
250.0
[9.85] Gauge port “M3” Gauge port “M4”
Servo pressure min. angle Servo pressure max. angle
Loop flushing 0.5625-18UNF-2B 0.5625-18UNF-2B
shuttle valve [9/16 -18UNF-2B] [9/16 -18UNF-2B]
Charge pressure
relief valve W
81.0
M4
Control start
[3.21]
adjustment
Case drain “L1”
M3
1.3125-12UN-2B
[1 5/16 -12UN-2B]
W
A
[8.08]
205.0
Y
Supply pressure
[4.06]
103.0
M1
Shuttle valve
0.5625-18UNF-2B
57.1 ]
[2.25
[9/16 -18UNF-2B]
53.0
[9/16 -18UNF-2B]
[4.94]
125.0
X1
[4.78] [9/16 -18UNF-2B] per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
[1.93]
345.0
49.0
[13.60] [7/16 -14UNC-2B]
27 [1.06] min.
full thread depth
Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 91.0
]
[3.58
91.0
] 60.0
[3.58 ]
60.0 [2.36
]
[2.36
Gauge port “M1”+”M2”
X System pressure “A”+”B” Gauge port “M4”
0.5625-18UNF-2B
[9/16 -18UNF-2B] Servo pressure max. angle
0.5625-18UNF-2B
M3
[1.09
[4.80]
57.1 ]
[2.25
5
M4
Y W
[5.44]
138.0
M5
Supply pressure
Shuttle valve
[2.53]
0.5625-18UNF-2B
DN 25 typ II 40 MPa series [9/16 -18UNF-2B]
per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B Split flange boss “B”
[7/16 -14UNC-2B]
27 [1.06] min. DN 25 typ II 40 MPa series
full thread depth per ISO 6162 [SAE 1.00]
4 thread: 0.4375-14UNC-2B
[7/16 -14UNC-2B]
27 [1.06] min.
full thread depth
P001 806E
Z
X
Mounting flange surface
flange 180 B4 HL
per ISO 3019/2
Speed pick-up
F
E 9.0
[0.35] Ø30.0 [1.18]
B
other side max.
screw head space
R1.6
[3.12]
[0.06]
79.2
.0
30
Ø1 .12)
Ø180.0 - 0.063
[7.087 - 0.002]
[8.35 ± 0.07]
212.0 ± 1.8
( 5
Ø120.0
Ø55.0
[4.72]
[2.17]
ØA
ØD
[3.12]
ØG
79.2
H
Ø18.0 ± 0.2
[0.71 ± 0.01]
9.0 25.0
[0.35] [0.99]
C 79.2 79.2
40.0
[3.12] [3.12]
[1.59]
Coupling may not protrude 212.0 ± 1.8
beyond this surface [8.35 ± 0.07] P001 819E
Cartridge flange
51C160 proportional and two-position control, HZB1 (Side port on top, Axial port below)
Y 84.0
]
[3.31
84.0
]
[3.31
X
Gauge port “M4”
Gauge port “M3” Servo pressure max. angle
146.0 0.5625-18UNF-2B
Servo pressure min. angle
[5.73] 0.5625-18UNF-2B [9/16 -18UNF-2B]
54.0 [9/16 -18UNF-2B]
Charge pressure [2.13] W
relief valve
M4
Loop flushing Control start
shuttle valve adjustment
Case drain “L1”
M3
1.3125-12UN-2B
[8.08]
205.0
[1 5/16 -12UN-2B]
A W
L1
Y Supply pressure
Shuttle valve
M1
[2.1]
53.0
51.0
6
51.0
Alternate position
Case drain “L2”
1.3125-12UN-2B min. angle stop Gauge port “M7”
Control mounting U
adjustment surface
[1 5/16 -12UN-2B] Control pressure
0.5625-18UNF-2B
U M7
Split flange boss “A”+”B”
[9/16 -18UNF-2B] DN 25 typ II 40 MPa series Shaft centerline
X1
per ISO 6162 [SAE 1.00]
239.0 4 thread: 0.4375-14UNC-2B
[1.93]
49.0
[9.40] [7/16 -14UNC-2B]
27 [1.06] min.
full thread depth
Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 91.0
]
[3.58
91.0
]
[3.58 60.0
]
60.0 [2.36
]
Gauge port “M1”+”M2” [2.36
System pressure “A”+”B” Gauge port “M4”
X 0.5625-18UNF-2B
[9/16 -18UNF-2B]
Servo pressure max. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
M3
177.0
[6.96] B A W
M4
6
27.7 ]
[1.09
W
57.1 ]
[2.25
M4
Y
L1
Supply pressure
M5
Shuttle valve
0.5625-18UNF-2B
[9/16 -18UNF-2B]
[2.52]
X
Mounting flange surface
cartridge flange Z
F
Case drain “L1”
E 96.0 1.3125-12UN-2B
[3.78] [1 5/16 -12UN-2B]
B O-ring 3.00x220.00 FPM Ø30.0 [1.18]
[0.12x8.66] other side max.
screw head space
45
Ø22.0 ± 0.3
°
[0.87 ± 0.01]
[4.09]
104.0
Ø230.0 - 0.029
[9.055 - 0.001]
Z
Ø184.0
Ø142.0
Ø120.0
Ø55.0
[7.24]
[2.17]
Clea
[5.59]
[4.72]
ØA
ØD
min rance
. Ø3
[12.7 23.6
4]
[4.09]
104.0
ØG
Alternate position
C
Case drain “L2”
Coupling may not protrude 1.3125-12UN-2B 140.0 140.0
beyond this surface [1 5/16 -12UN-2B] [5.51] [5.51]
11.2 20.03 318.0 ± 2.0
[0.44] [0.79] [12.52 ± 0.08]
140.8 max.
[5.54 max.] P001 820E
Y 97.0
]
[3.82
97.0
]
[3.82
X
Gauge port “M4”
Gauge port “M3”
325.0 Servo pressure max. angle
Servo pressure min. angle 0.5625-18UNF-2B
[12.79] 0.5625-18UNF-2B
Loop flushing [9/16 -18UNF-2B]
Charge pressure [9/16 -18UNF-2B]
shuttle valve relief valve
W
131.5
M4
[5.18] Control start
Case drain “L1” adjustment
M3
1.3125-12UN-2B
[1 5/16-12UN-2B]
W
A
[9.39]
239.0
Y
Supply pressure
L1
M1
[9/16 -18UNF-2B]
[2.44]
0.5625-18UNF-2B
62.0
8
137.0
[5.4]
M5
L2
Alternate position
min. angle stop Control mounting U
adjustment Gage port “M7” surface M7
Case drain “L2”
1.3125-12UN-2B Control pressure
0.5625-18UNF-2B
U Split flange boss “A”+”B”
[1 5/16-12UN-2B] DN 32 typ II 40 MPa series Shaft centerline
[9/16 -18UNF-2B] X1
131.5 per ISO 6162 [SAE 1.25]
[1.93]
4 thread: 0.5-13UNC-2B
49.0
[5.18]
429.0 [1/2 -13UNC-2B]
[16.89] 25 [0.98] min.
full thread depth
Control pressure port “X1”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Y 99.0
]
[3.90
99.0 .0
] 65
[3.90 ]
65.0 [2.56
Gauge port “M1”+”M2” ]
[2.56
System pressure “A”+”B”
0.5625-18UNF-2B
Gauge port “M4”
X [9/16 -18UNF-2B]
Servo pressure max. angle
0.5625-18UNF-2B
359.0 [9/16 -18UNF-2B]
M3
[14.13]
B A W
182.0
M4
[7.15]
6
31.7 ]
[1.25
66.6 ]
[2.63
8
Y W
M4
L1
[6.11]
155.0
Supply pressure
Shuttle valve
M5
P001 808E
X
Mounting flange surface
Speed pick-up
flange 165-4 (SAE "E")
per ISO 3019/1
F
E Ø30.0 [1.18]
B other side max.
screw head space
O-ring 3.00x154.00 FPM
[0.12x6.06]
112.25
R3.0 [4.42]
[0.12]
Ø165.075 ± 0.025
[6.499 ± 0.001]
[10.24 ± 0.07]
260.0 ± 1.9
Z
Ø100.0
Ø118.0
[3.94]
[4.65]
Ø55.0
[2.17]
ØA
ØD
ØG
36.0
112.25
[4.42]
[1.42]
Ø20.5 ± 0.2
[0.81 ± 0.01]
15.65 25.0
[0.62] [0.98] 112.25 112.25
C [4.42] [4.42]
260.0 ± 1.9
Coupling may not protrude
[10.24 ± 0.07] P001 821E
beyond this surface
Dimension – Controls
Options TA** for 51-1 – Pressure Compensator Control (Frame Size: 060, 080, 110)
Z Z Z
Electric brake Hydraulic brake
pressure defeat pressure defeat
AA TAD* TACA
Control pressure port “XB”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
[2.94]
XB
XB
M3
M3
75.0
[2.17]
55.0
Shaft centerline
[2.17]
55.0
AB
AC
Flange
XA
XA
X1
X1
[5.05]
128.2
Control pressure port “XA”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Solenoid for
Shaft centerline
Electric brake pressure defeat
P001 838E
Solenoid connectors
Plug face DIN 46350 (Supplied) AMP Junior Timer two pin (Supplied)
Mating connector No.: K09129 Mating connector No.: K19815
Id. No.: 514117 Id. No.: 508388
2 1
A B
P001752 P001751
Shaft rotation is determined by viewing from shaft end. Ports with O-ring seal and inch threads shall be in
accordance with ISO 11926/1. Splite flange boss A and B per ISO 6162 is identical with high pressure
series SAEJ518 code 62 (6000 psi). Contact your Danfoss representative for specific installation drawings.
Dimension – Controls
Options TA** for 51 – Pressure Compensator Control (Frame Size: 160, 250)
Z
Control option
TAC2
Control pressure port “XA”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
XA
Shaft centerline
X1
[2.28]
58.0
X4
XB
JB
Control pressure port “XB”
Flange
0.5625-18UNF-2B
Supply pressure [9/16 -18UNF-2B]
Shuttle valve
0.5625-18UNF-2B
JA Z [9/16 -18UNF-2B]
P001 839E
Shaft rotation is determined by viewing from shaft end. Ports with O-ring seal and inch threads shall be in
accordance with ISO 11926/1. Splite flange boss A and B per ISO 6162 is identical with high pressure
series SAEJ518 code 62 (6000 psi). Contact your Danfoss representative for specific installation drawings.
Dimension – Controls
Options TH** for 51-1 – Hydraulic Two-Position Control (Frame Size: 060, 080, 110)
Z Z Z
Electric brake Hydraulic brake
pressure defeat pressure defeat
AA THD* THC2
Control pressure port “XB”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
[2.94]
XB
XB
M3
M3
75.0
[2.15]
54.5
Shaft centerline
[2.15]
54.5
AB
AC
Flange
XA
XA
X1
X1
[5.05]
128.2
Control pressure port “XA”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
Control pressure port “X1”
Shaft centerline 0.5625-18UNF-2B
[9/16 -18UNF-2B]
Solenoid for
Electric brake pressure defeat
Control pressure port “X1”
0.5625-18UNF-2B P001 840E
[9/16 -18UNF-2B]
Solenoid connectors
Plug face DIN 46350 (Supplied) AMP Junior Timer two pin (Supplied)
Mating connector No.: K09129 Mating connector No.: K19815
Id. No.: 514117 Id. No.: 508388
2 1
A B
P001752 P001751
Shaft rotation is determined by viewing from shaft end. Ports with O-ring seal and inch threads shall be in
accordance with ISO 11926/1. Splite flange boss A and B per ISO 6162 is identical with high pressure
series SAEJ518 code 62 (6000 psi). Contact your Danfoss representative for specific installation drawings.
Dimension – Controls
Options TH** for 51 – Hydraulic Two-Position Control (Frame Size: 160, 250)
Control option
THC2
Z Control pressure port “XA”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
XA
Control pressure port “X1”
Shaft centerline 0.5625-18UNF-2B
[9/16 -18UNF-2B]
X1
[2.28]
58.0
X4
XB
JB
Control pressure port “XB”
Flange
0.5625-18UNF-2B
Supply pressure [9/16 -18UNF-2B]
Shuttle valve
0.5625-18UNF-2B
JA Z [9/16 -18UNF-2B]
P001 841E
Shaft rotation is determined by viewing from shaft end. Ports with O-ring seal and inch threads shall be in
accordance with ISO 11926/1. Splite flange boss A and B per ISO 6162 is identical with high pressure
series SAEJ518 code 62 (6000 psi). Contact your Danfoss representative for specific installation drawings.
Dimension – Controls
Options E*B1, F*B1 for 51-1 – Electrohydraulic Two-Position Control (Frame Size: 060, 080, 110)
Z Z
Control options
E*B1 / F*B1
M5
M3
Shaft centerline
AB
Solenoid for
Electric 2 position control
Gauge port “M3”
Shaft centerline Servo pressure min. angle
0.5625-18UNF-2B
[9/16 -18UNF-2B]
P001 822E
Solenoid connectors
Plug face DIN 46350 (Supplied) AMP Junior Timer two pin (Supplied)
Mating connector No.: K09129 Mating connector No.: K19815
Id. No.: 514117 Id. No.: 508388
2 1
A B
P001752 P001751
Shaft rotation is determined by viewing from shaft end. Ports with O-ring seal and inch threads shall be in
accordance with ISO 11926/1. Splite flange boss A and B per ISO 6162 is identical with high pressure
series SAEJ518 code 62 (6000 psi). Contact your Danfoss representative for specific installation drawings.
Dimension – Controls
Options E*A5, F*A5 for 51 – Electrohydraulic Two-Position Control (Frame Size: 160, 250)
Control options
E*A5/F*A5
Gauge port “M8”
Z
Internal control pressure
0.5625-18UNF-2B
[9/16 -18UNF-2B] Gauge port “M7”
Internal control pressure
0.5625-18UNF-2B
Shaft centerline [9/16 -18UNF-2B]
[2.82]
72.0
AD
Flange
AA Z P001 823E
Solenoid connector
Shaft rotation is determined by viewing from shaft end. Ports with O-ring seal and inch threads shall be in
accordance with ISO 11926/1. Splite flange boss A and B per ISO 6162 is identical with high pressure
series SAEJ518 code 62 (6000 psi). Contact your Danfoss representative for specific installation drawings.
Dimension – Controls
Options T1**, T2**, T7** for 51-1 – Electrohydraulic Two-Position Control (Frame Size: 060, 080, 110)
Z Z Z
Electric brake Hydraulic brake
pressure defeat pressure defeat
AA T*D* T*C2
[2.94]
XB
XB
M3
M3
74.6
[2.17]
55.0
Shaft centerline
[2.17]
55.0
AB
AC
Flange
XA
XA
X1
X1
[5.05]
128.2
Solenoid for
Shaft centerline Solenoid for
Electric brake
pressure defeat Electric 2 position control
Solenoid for
Electric 2 position control
P001 824E
Solenoid connectors
Plug face DIN 46350 (Supplied) AMP Junior Timer two pin (Supplied)
Mating connector No.: K09129 Mating connector No.: K19815
Id. No.: 514117 Id. No.: 508388
2 1
A B
P001752 P001751
Shaft rotation is determined by viewing from shaft end. Ports with O-ring seal and inch threads shall be in
accordance with ISO 11926/1. Splite flange boss A and B per ISO 6162 is identical with high pressure
series SAEJ518 code 62 (6000 psi). Contact your Danfoss representative for specific installation drawings.
Dimension – Controls
Options T1C2, T2C2 for 51 – Electrohydraulic Two-Position Control (Frame Size: 060, 080, 110)
Control option
T*C2
Z
Solenoid for
Shaft centerline Electric 2 position control
[1.93]
49.0
HB
Flange
HA Z P001 825E
Solenoid connector
Shaft rotation is determined by viewing from shaft end. Ports with O-ring seal and inch threads shall be in
accordance with ISO 11926/1. Splite flange boss A and B per ISO 6162 is identical with high pressure
series SAEJ518 code 62 (6000 psi). Contact your Danfoss representative for specific installation drawings.
Dimension – Controls
Options EPA1, EQA1 for 51 – Electrohydraulic Two-Position Control (All Frame Sizes)
Control option
EQA1
Control pressure port “XA”
0.5625-18UNF-2B
Z
[9/16 -18UNF-2B]
FJ
0.5625-18UNF-2B
FF
[9/16 -18UNF-2B]
FG
FH
FE
Solenoid connectors
Shaft rotation is determined by viewing from shaft end. Ports with O-ring seal and inch threads shall be in
accordance with ISO 11926/1. Splite flange boss A and B per ISO 6162 is identical with high pressure
series SAEJ518 code 62 (6000 psi). Contact your Danfoss representative for specific installation drawings.
Dimension – Controls
Options L1B1, L2B1, L7B1 for 51 – Electrohydraulic Two-Position Control (All Frame Sizes)
Control option
L*B1
Z
Solenoid for
Electric proportional
control
Shaft centerline
[1.93]
49.0
LB
Flange
LA
Z P001 827E
Solenoid connectors
Plug face DIN 46350 (Supplied) AMP Junior Timer two pin (Supplied)
Mating connector No.: K09129 Mating connector No.: K19815
Id. No.: 514117 Id. No.: 508388
2 1
A B
P001752 P001751
Shaft rotation is determined by viewing from shaft end. Ports with O-ring seal and inch threads shall be in
accordance with ISO 11926/1. Splite flange boss A and B per ISO 6162 is identical with high pressure
series SAEJ518 code 62 (6000 psi). Contact your Danfoss representative for specific installation drawings.
Dimension – Controls
Options D7M1, D8M1 for 51 – Electrohydraulic Two-Position Control (Frame Size: 060, 080, 110)
Control option
D*M1
Z
Control pressure port “XA”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
[2.35]
59.6
Shaft centerline
[2.82]
71.6
GE
Electric proportional
[4.33]
GD
110.0
pressure reducing valve
Flange
Solenoid connector
Shaft rotation is determined by viewing from shaft end. Ports with O-ring seal and inch threads shall be in
accordance with ISO 11926/1. Splite flange boss A and B per ISO 6162 is identical with high pressure
series SAEJ518 code 62 (6000 psi). Contact your Danfoss representative for specific installation drawings.
Dimension – Controls
Options D7M1, D8M1 for 51 – Electrohydraulic Two-Position Control (Frame Size: 160, 250)
Control option
D*M1
Z
Control pressure port “XA”
0.5625-18UNF-2B
[9/16 -18UNF-2B]
[2.32]
59.0
Shaft centerline
[2.76]
Electric proportional
70
GE
[4.33]
GD
110.0
pressure reducing valve
Flange
Solenoid connector
Shaft rotation is determined by viewing from shaft end. Ports with O-ring seal and inch threads shall be in
accordance with ISO 11926/1. Splite flange boss A and B per ISO 6162 is identical with high pressure
series SAEJ518 code 62 (6000 psi). Contact your Danfoss representative for specific installation drawings.
Dimension – Controls
[2.3]
58.0
Shaft centerline Shaft centerline
BJ
BF
BH
BG
[4.47]
114
BE
Flange
Pressure compensator
BC Gauge port “M7” override
BB Control pressure Control pressure port “XB”
0.5625-18UNF-2B
BD Z [9/16 -18UNF-2B] 0.5625-18UNF-2B
[9/16 -18UNF-2B]
BA P001 828E
Shaft rotation is determined by viewing from shaft end. Ports with O-ring seal and inch threads shall be in
accordance with ISO 11926/1. Splite flange boss A and B per ISO 6162 is identical with high pressure
series SAEJ518 code 62 (6000 psi). Contact your Danfoss representative for specific installation drawings.
Dimension – Controls
Shaft centerline
X1
[1.93]
49.0
EB
Flange
Shaft rotation is determined by viewing from shaft end. Ports with O-ring seal and inch threads shall be in
accordance with ISO 11926/1. Splite flange boss A and B per ISO 6162 is identical with high pressure
series SAEJ518 code 62 (6000 psi). Contact your Danfoss representative for specific installation drawings.
Comatrol
www.comatrol.com Local address:
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
Danfoss
Power Solutions Trading
Danfoss Danfoss Danfoss (Shanghai) Co., Ltd.
Power Solutions (US) Company Power Solutions GmbH & Co. OHG Power Solutions ApS Building #22, No. 1000 Jin Hai Rd
2800 East 13th Street Krokamp 35 Nordborgvej 81 Jin Qiao, Pudong New District
Ames, IA 50010, USA D-24539 Neumünster, Germany DK-6430 Nordborg, Denmark Shanghai, China 201206
Phone: +1 515 239 6000 Phone: +49 4321 871 0 Phone: +45 7488 2222 Phone: +86 21 3418 5200
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.