Documente Academic
Documente Profesional
Documente Cultură
AHU
1 2 3 4 5 6 7 8 9 10 11 12 13 14
size
Range of 1000 1600 2800 4300 6100 8000 10000 12500 15500 18800 22000 25000 30000 33000
efficiency - - - - - - - - - - - - - -
[m3/h] 1800 3700 5600 8300 11200 15000 18800 22700 28000 34000 40000 46000 53000 60000
Air velocity in radiator the port, the types of filters, damping method and sound intensity level are some
of the factors determining the size of the AHU to be chosen from the proposed types of series.
2
Our air-handing units are built on the basis of compact and modular sets. The modular configuration
enables the units to be supplied as individual modules set up on the object. According to the destination, AHU
are equipped with the following functional blocks (sections):
• rough (G class), precise (F class) and absolute (H class) class filtering section
• muffling section
• heating section
• damping section
3
Filtering sections are equipped with filters made by Camfil, Eufilter, Krakfil, Ultramare.
Among filters consistent with EN 779 there are filters, such as:
Classification of filters:
Re-circulation chamber.
The cross-flow heat exchanger is a widely used device, which has the advantage of not being in contact
between replacement and dead air. This exchanger is made of sheet aluminum plates arranged to create narrow
ducts for replacement and removed airflow. Air streams wash the wall and exchange heat via thin sheet
aluminum. Exhausted and downcast air does not mix, which enables these exchangers to be used in areas where
there is a considerable smell deterioration in removed air. The
cross-flow heat exchanger provides up to 60% of temperature heat
recovery. This device is also produced for us by Heatex and
Klingenburg.
Everywhere where the replacement and dead air cannot be mixed due to the fact that there are biological or
chemical contaminations in the ventilated area, heat recovery is executed with the use of exchangers in which the
heat transportation is made by the mediating liquid which is a mixture of water and glycol the glycol exchanger.
The radiator, placed in the area of removed air, receives heat from the dead air. The mediating agent, supported by
the pump, transports it into the heater placed in the downcast section of replacement air.
Droplet separator.
7
Structure:
Aluminum section frame
Throttle
The air-handling unit construction is built based on the frame made of the aluminum alloy closed
section with 50x50 mm cross-section. The surfaces of the section are anodized to prevent them from corrosion.
The frame is equipped with fixed stationary and inspection covers (panels). Wall panels are made up with two
cassettes with incombustible, pressed mineral wool 50 mm thick.
Aluminum side outlet elbow Fan frame on vibration isolators with Strengthened aluminum sections.
transportation protection
8
CWD units for roof applications, used for an external assembly, are equipped with a drip roof, intake
vent and exhaust vent. Throttles on the inlets of air-handling unit are placed inside the housing to protect the
mechanisms moving the throttle planes against freezing.
Throttle
9
Due to the increasing requirements being applied to air processing units, mainly for pharmaceutical,
electronic, food industries and hospitals, we produce hygienic CWH units. Hygienic air-handling units are
equipped, among other things, with:
• air-tight throttles,
In accordance with the clients' wishes, these units can also be equipped with:
• additional droplet tank made of a stainless sheet with liquid drainage from the bottom of the unit,
Fan housing (in version with belt drive) is equipped with a blowdown connection, which facilitates
washing the fan.
Drip tray.
Ask form:
11
12
Designation examples:
www.wentylacje.pl
wentylacje@home.pl