1. Handheld controller
k
ur ity Pac e
Sec nc
r c o mplia
fo
with 11!
rt
R Pa
21 CF
Cerity Networked
Data System for NEW
pharmaceutical QA/QC
The Cerity networked data • Fully-scaleable client/server system
system is a targeted application providing for up to 150 signal channels
that automates most routine and 30 concurrent users.
tasks in pharmaceutical QA/QC. • A user interface that is optimized to
model the QA/QC workflow.
• Generation and management of
trustworthy and reliable records for
support of 21 CFR Part 11.
• Control of additional systems such as
Agilent 6890 GCs and 35900E interfaces,
and Waters® Alliance® systems.
Superior HPLC modules for best
chromatography results
Autosamplers
Detectors
Norm.
mAU 10
120 8
The diode-array detector gives outstanding
6 Match 998.9
100 sensitivity over the entire wavelength
4 range—both UV and visible. Its features
80 74.5 ng = 120 mAU include:
2
60
• Deuterium and tungsten lamps that
0
600 nm/20 nm ensure the highest light output, from
40 300 400 500 600 700 800 Noise = ± 1.2 × 10-5 190 to 950 nm
Wavelength [nm] 7.45 ng = 10 mAU • 1024 diodes and a programmable slit
20 220 nm/20 nm to optimize wavelength resolution
Noise = ± 0.7 × 10-5
0
0 2 4 6 8 10 12 14 16 18 Time [min]
Less time needed for laboratory tasks
For most laboratories, the number of samples keeps rising, while available
space, instruments and personnel remain the same.
mAU
The Agilent 1100 Series HPLC provides an answer to this challenge. This 1000
system is designed for quick startup, automated validation, ease of use,
800
fast chromatography and automated data transfer to save you time without
600
demanding more space or resources.
400
200
Amount
25
24
22
600
400 Sample name Data file Peak time Area Height Amount
200 S1_T33
S1_T33
010-0201.D
010-0101.D
14.34
14.33
1226.4
1192.9
94.88
90.34
22.45
21.66
0 S1_T33 010-0101.D 14.33 1249.8 92.51 23.13
S1_T33 010-0201.D 14.34 1201.1 92.68 22.01
S1_T33 010-0202.D 14.35 1260.7 95.44 22.86
0 0.25 0.5 0.75 1 S1_T33 010-0203.D 14.32 1353.0 103.51 25.43
S1_T33 010-0301.D 14.33 1255.6 95.53 21.95
S1_T33 010-0301.D 14.34 1268.4 98.54 22.33
Time [min] S1_T33 010-0301.D 14.34 1242.4 95.32 23.61
Average: 14.34
Standard Dev. 1.21
Cycle time = 14 minutes RSD:
Minimum:
0.99
21.99
2 4 6 8 10 12
Time [min]
Injection systems
Optional loop for large-volume injection
Detectors
LAN capabilities
Select among various hardware and software system control and data handling products:
• A handheld control module
• Agilent ChemStation for HPLC with optional software for spectral acquisition and evaluation
• Agilent ChemStore C/S data organization system
• Agilent Security Pack software module
• Agilent ChemStation Plus, which combines ChemStation, ChemStore and ChemAccess in a secure
NT-server environment, enhanced with ChemStation Plus Security Pack
Agilent 1100 Series • Cerity networked data system for pharmaceutical QA/QC
micro vacuum degasser
Agilent 1100 Series Agilent 1100 Series Agilent 1100 Series Agilent 220 micro plate sampler
well plate autosampler and thermostatted micro autosampler micro well plate autosampler with dedicated software
thermostatted version and thermostatted version
Agilent 1100 Series Agilent 1100 Series Agilent 1100 Series Agilent 1100 Series
fluorescence detector refractive index detector LC/MSD VL or LC/MSD Trap
LC/MSD SL
Industry-specific total solutions that save time and money
Agilent 1100 Series well-plate LC system Agilent 1100 Series GPC analysis system Agilent 1100 Series LC value system
When well-plate sampling and high This solution offers cost-effective routine A complete, easy-to-use solution for
sample throughput are important, the polymer characterization by GPC-SEC laboratories expanding to HPLC. You
well-plate LC system—optimized for fast with refractive index and UV detectors. can have a 1100 Series system known
sample analysis—is the answer. This It is based on the reliable Agilent 1100 for ruggedness and reliability, easy and
system can increase the speed of sample Series HPLC modules and the easy-to-use fast maintenance, minimal user training,
analyses up to a factor of ten, with Agilent ChemStation with integrated GPC and built-in productivity features.
superior retention time and area precision. data analysis software. At a surprisingly low cost.
Pharmaceutical Bioscience Solutions Environmental Solutions Food Solutions with HPLC Polymer and Hydrocarbon
Applications with HPLC from Agilent Technologies with HPLC publication publication number Processing Solutions with HPLC
publication number 5968-2635E publication number 5980-0793E number 5968-6726E 5968-6663E publication number 5968-7020E
Specifications
Agilent 1100 Series Systems and Modules for HPLC
System specifications Agilent 1100 Series Autosamplers Agilent 1100 Series Fluorescence Detector
(The system includes a binary pump,
autosampler, column compartment and Standard autosampler Performance: 10 fg anthracene LOD,
diode-array detector) Sample capacity: Up to 100 vials Excitation wl: Range 200–700 nm,
Injection volume: 0.1–100 µl standard range Emission wl: Range 280–900 nm,
Performance specifications Optional extension: Spectra storage: All
Baseline noise: ±1 × 10-5 AU, at 254 nm • Up to 1800 µl
Ret. precision: < 0.3 % RSD • Up to 5000 µl
Inj. vol. precision:Typically < 0.5 % from 5–100 µl Thermostatted micro autosampler Agilent 1100 Series Refractive Index Detector
Maintenance and system test Sample capacity: 100 × 2-ml vials in standard
Accessibility to all maintenance parts from front tray; microvials (100 or Short-term noise: ± 2.5 × 10-9 RIU
Maintenance instructions through multimedia 300 µl) with sleeves Drift: 200 × 10-9 RIU/h
CD-ROM Injection volume: 0.01–8 µl with small loop Valves: Automatic purge and
Time for full system test (OQ/PV) < 4 hours capillary; 0.01–40 µl with automatic solvent recycle
Space and delay volume extended loop capillary
System delay volume (typical): < 250 µl Well-plate autosampler
Required benchspace: < 36 cm Sample capacity: 2 well plates (96 and 384), Agilent 1100 Series LC/MSD
System control or up to 100 2-ml vials
Through local computer software, LAN or local Injection volume: 0.1–100 µl standard range Mass range: VL – m/z 50 – 1500
handheld control module Up to 1800 µl with multiple- SL – m/z 50 – 3000
GLP features draw (hardware modifi- Mass accuracy: ± 0.13 u
Early maintenance feedback—EMF cation required) Mass axis stability: ± 0.13 u over 8 hours
(lamp burn time, usage, number of injections Micro well-plate autosampler SIM sensitivity:
with limits and feedback messages) Sample capacity: 2 well plates (96 and 384) Quantity Signal-to-noise ratio
plus 10 additional 2-ml VL 10 pg 50:1 RMS
vials or up to 100 2-ml vials reserpine (10:1 peak-to-peak)
Agilent 1100 Series Pumping Systems Injection volume: 0.01–8 µl with small loop SL 1 pg 50:1 RMS
capillary; 0.01–40 µl with reserpine (10:1 peak-to-peak)
Flow precision: 0.3% RSD extended loop capillary Scan sensitivity:
(typically < 0.15% RSD) Precision for all autosamplers Quantity Signal-to-noise ratio
Settable flow range Typically < 0.5% from SL 50 pg 50:1 RMS
• Isocratic: 0.001–10 ml/min 5-100 µl; typically < 1% reserpine (10:1 peak-to-peak)
• Binary: 0.001–5.0 ml/min from 1–5 µl
• Quaternary: 0.001–10 ml/min Thermostatted version of all autosamplers
• Capillary: 0.01 µl/min – 2.5 ml/min Temperature range: Settable from 4 °C–40 °C Agilent 1100 Series LC/MSD Trap
• Preparative: 0.001 to 100 ml/min 1° increments
Mass range: m/z 50 – 4000
Flow precision for Mass accuracy: ± 0.2 u
capillary pump: < 0.7 % RSD Agilent 1100 Series Variable Wavelength Mass axis stability: ± 0.2 u over 8 hours
(typically < 0.4 % RSD) Detector Full scan MS/MS sensitivity:
Settable Quantity Signal-to-noise ratio
composition range: 0–100%, in 0.1% Short-term noise: ± 0.75 × 10-5 AU, 254 nm 25 pg 50:1 peak-to-peak
(binary/quaternary increments, from two or Wavelength range: 190–600 nm
channels) four independent channels