EuroPrime EFC 209

Epoxy Resin Base Low Viscous Primer

For bonding old and new concrete and also


used for repair works, tile works, pile heads,
stone/marble works and screeds. EuroPrime
EFC 209 bonds with almost all building
materials.

Description

EuroPrime EFC 209 is based on solvent-free


epoxy resins. It is supplied as a two-component
material in pre-weighed ready for on-site mixing
and use.

Uses

 Surface Primer for Epoxy Floorings



 Surface sealer

 Repair primer

 Bonding agent for plywood,


gypsum/silicate board and steel

 Sand and aggregate stabilizer for


architectural purposes

The product is ideal for car parking, roads, bridges,


pavements, loading bays and factories.

For bonding granolithic floor toppings such as


Epoxy floor coatings, sand cement screed, mortars
and epoxy screed.

EuroPrime EFC 209 is equally suitable to internal


and external applications.
EuroPrime EFC 209

Advantages Properties

 Exhibits high mechanical strength Test method Typical Result


___________________________________________
2
 Positive adhesion - exceeds the tensile Tensile strength (BS 6319, Pt 7): >10 N/mm
strength of the host concrete ______________________________________
2
Flexural strength (BS 6319, Pt 3): 35 N/mm
 High penetration to substrates and increases _____________________________________
the bond strength.
2
Shear strength (BS 6319, Pt 4): 25 N/mm
 Easy to apply. ______________________________________

Adhesive bond to concrete:


 Economical Floor Primer system
In general, the bond will always exceed the tensile
strength of the host concrete.
Packing The properties were measured at 20 C
o

Pot lift: 1 hour


EuroPrime EFC 209 is available in 1 & 20 Ltr _____________________________________
Packing.
Initial hardness: 4 hours
Full cure: 8 hours
Design Criteria
Surface Preparation
EuroPrime EFC 209 is designed with an overlay
o o
time of 24 hours at 20 C, 12 hours at 35 C and 5 Clean all surfaces and remove any dust, unsound
o material, plaster, oil, paint, grease, corrosion deposits or
hours at 45 C, making it more suitable for use
algae.
where additional steel reinforcement and formwork
has to be fitted or where temperatures are high. Roughen the surfaces, remove any laitance and expose
The minimum application temperature for the aggregate by light scabbling or grit-blasting.
o
EuroPrime EFC 209 is 5 C.

Mixing. Mixing
The entire contents of the part B hardener should Any steel reinforcement and formwork should be
then be poured into the part A base and the two prepared, cut to size and shape, and made ready for
materials thoroughly mixed using a suitable slow- assembly before mixing commences.
speed drill or mixing paddle for 2 minutes. The
sides of the tin should then be scraped and mixing Care should be taken to ensure that EuroPrime EFC 209
should continue for further 2 minutes. is thoroughly mixed. The hardener and base
components should be stirred separately before mixing
to disperse any settlement.
EuroPrime EFC 209

Application
Coverage

The coverage of EuroPrime EFC 209 is approximately 6


EuroPrime EFC 209 should be applied as soon as 2
to 7 m / Ltr
the mixing process has been completed. It can be
applied by brush, roller or airless spray to the
prepared surfaces.
Technical Service
Concrete Primer

The new concrete or screed may be applied to the EUROBUILD will be pleased to afford full Technical
coated substrate up to 4 hours after application at support on specifiers application.
o o o
20 C, 2 hours at 35 C and 1 hour at 45 C.
NOTE: The information supplied in our literature or given by
However, the coated substrate should be left for our employees is based upon extensive experience and,
one hour before the new concrete or screed is together with that supplied by our agents or distributors, is
placed. given in good faith in order to help you. Our Company policy is
one of continuous Research and Development; we therefore
reserve the right to update this information at any time without
Where EuroPrime EFC 209 is to be used as part of prior notice. We also guarantee the consistent high quality of
a repair system to form a substrate/repair barrier, our products; however, as we have no control over site
care should be taken to achieve an unbroken conditions or the execution of the work, we accept no liability
for any loss or damage which may arise as a result thereof.
coating. One coat should be applied and allowed
to set. A second coat should be applied and used
as the bonding coat. In some situations (e.g. Health and Safety
sprayed concrete repairs) it may be advantageous
to scatter dust-free sharp sand over this coat and As with all chemical products, caution should always be
leave it to harden. exercised. Protective clothing, such as gloves and
Notes goggles, should be worn (see packaging for specific
The coverage figures for EuroPrime EFC 209 products instructions). Treat any splashes to the skin or eyes with
are theoretical - due to wastage factors and the variety fresh water immediately. Should any of the products be
and nature of possible substrates, practical coverage accidentally swallowed, do not induce vomiting, but call
figures will be reduced. EuroPrime EFC 209 fast setting for medical assistance immediately.
suitable for cold weather working can be made available
on request.