Multiple‐Output Linear Regulated
u
.a
DC Power Supply Model 305D‐II
m
co
Dual Adjustable Output Channel: 0 ~ 30 V, 0 ~ 5 A DC
s.
Fixed Output Channel: 5 V / 3 A DC
ic
Attention! Read through and understand this manual before use
on
the product! tr
Warranty
ec
The manufacture warrants in parts and workmanship for one year from date of
shipment, and is limited to repair or replacement of the product only.
el
This warranty does not apply to defects resulting from action of the user such as
ht
Warning
hl
This product is constructed for providing operating two variables voltage channels
ig
For the variable outputs, the power consumption of the load must not exceed 5 A DC.
If the current is exceeded the power supply is overloaded.
w
u
Channel 1&2 Current & Voltage Display Windows
.a
m
co
Channel 1 (Slave) Current & Voltage Adjustment Channel 2 (Master) Current & Voltage Adjustment
s.
Current&Voltage Current&Voltage
Limit LED Limit LED
ic
Power Switch
on
Channel 1 Output Channel 2 Output Channel 3 Output
tr
ec
Channel 1&2 Combination Buttons
el
Features
ht
Model 305D-II
Dual Display Dual 3-digit LED Current & Voltage @ 2 Channel
ig
0 ~ 30 V @ 0 ~ 5 A Dual Channel or
Variable Voltage Output DC
0 ~ 60 V @ 0 ~ 5 A Single Channel
hl
0 ~ 5 A @ 0 ~ 30 V Dual Channel or
Variable Current Output DC
0 ~ 10 A @ 0 ~ 30 V Single Channel
ig
Indicator
Display Accuracy 1% +/- 1digit voltage & current
w
Operation
1. The Power Supply must be powered using the rated line voltage (240 +/- 10%.
u
VAC 50 HZ).
.a
2. Always keep good ventilation at the rear of the power supply, and do not use
the power supply where a temperature exceeds 45°C.
m
3. Before turning the power supply ON, remove all connected loads and set the
co
Voltage Adjustment Knob to the full counter-clockwise position (0V DC output).
4. To operate the power supply as a constant current supply, the current output
s.
should be set between 10% and 100% of the rated value (5A). The Current
Limiting Indicator will light when the current limiting circuit is activated.
ic
5. Use the Current and Voltage Adjustment Knobs for setting variable Current
on
and Voltage output signals respectively. Use Variable Output Terminals for
connections.
tr
6. For 5VDC/3A output, use the Fixed Output Terminals.
ec
7. The digital displays will indicate actual current and voltage outputs for each
channel.
el
8. Keep the meter's cooling vents (rear & sides) clear of obstacles to prevent
ht
overheating.
9. Make sure good and tight connection between terminals and loads.
ig
a. Disconnect any load from terminals and turn the Voltage Adjustment
ig
c. Press the Power Switch ON. The LED windows will be light up which
indicating that the power supply is in the operation state.
w
u
g. Adjust the current CW to a required value by monitoring the current
LED window.
.a
h. Remove the jumper lead.
i. Adjust the voltage to a required value between 0 ~ 30 V.
m
j. Check the CC mode by shorting output terminals again by monitoring
the current LED window.
co
General Observations on Safety
s.
ic
When it may be necessary to replace a blown fuse it is essential that pull the power
lead out from the power source and a replacement fuse must have same physical
on
dimension and electrical rating (voltage and current).
If the replacement fuse keeps blown, pull off the power lead and check or disconnect
tr
the external device.
ec
Do not operate or maintenance the power supply when its cover removed.
el
Place the power supply on a hard, flat and flame resistant surface.
ig