Sunteți pe pagina 1din 1

Asymmetrical Recycling

Timer (Twin Timer) AT 200


(ON or OFF Time first)

WIRING EXAMPLE Application Examples


~ • Refrigeration plants for freezing cycle & defrost cycle.
+
• Centre pivoting for watering cycle and moving cycle on
irrigation systems.
A1 15 25 Y1 Y2 Y3 • System purging on boiler control panels.
• Chemical dosing and mixing.
• Conveyor transfer control for manual packaging.
• Material handling control in cutting applications.
• Periodic lubrication control on equipment.
16 18 A2 26 28 Y4 • Periodic moisture cycle control on catering equipment.

SUPPLY RELAY
TYPE VOLTAGE AC/DC CONTACTS
ORDERING
A-LINE CODE AT200 / 250 A D

Technical Specification
Power Supply: Time Time Setting: Time Unit

AC: 24, 110, 250 (ie. 90-250), 400 (ie. 380-415) V ±15% Setting accuracy: 5% Scale 10 to 100% (Link
dependent)

DC: 48, 60, 110 VDC ±10% Repeatability: 0.5% 2 0.2 to 2 Sec or min
6 0.6 to 6 Sec or min
AC/DC: 24 (ie. 12 or 24) V 20 2 to 20 Sec or min
Relay: 60 6 to 60 Sec or min

Note: 400V units have a 45mm wide housing 1 x DPDT, 5A/250VAC per contact 120 12 to 120 Sec or min
240 24 to 240 Sec or min

Description of Controls
back A1 15 25
front Y1 Y2 Y3
L1: The red “Relay ON” LED illuminates when the relay is energised.
A-LINE AT200
Asymmetrical Recycling
Timer 20
L2: The green “Power ON” LED illuminates when power is supplied to the unit. The LED flashes
T1
6 60 when the unit is timing. Before the relay switches, the flash rate increases.
2
120 S1
Range
240
Sec (min) S1: The Time Range of the first time interval (T1) is set on S1. Time ranges are 2, 6, 20, 60, 120
L1
40% & 240. The range selected is timed in seconds with no link to Y1, or minutes with Y1 linked to
70%
10% P1 Y3.
Time Set 100%
L2 20
T2 P1: The Time Setting of the first time interval (T1) is adjusted on P1. The time setting can be
6 60
2 S2 adjusted from 10% to 100% of the selected time.
120
Range
240
40%
S2: The Time Range of the second time interval (T2) is set on S2. Time ranges are 2, 6, 20, 60,
10%
70% 120 & 240. The range selected is timed in seconds with no link to Y2, or minutes with Y2 linked
P2
Time Set 100% to Y3.

front
P2: The Time Setting of the second time interval (T2) is adjusted on P2. The time setting can be
26 28 Y4
back 16 18 A2
adjusted from 10% to 100% of the selected time.

Operational Diagrams

Function 1 : Asymmetrical Recycling, OFF cycle First Function 2 : Asymmetrical Recycling, ON cycle

Power Power
Supply Supply
T2 T2 T2 T2 T1 T1 T1 T1
Relay ON T1 T1 T1 T1 Relay ON T2 T2 T2 T2

T1 = Time setting for first cycle


T2 = Time setting for second cycle

S-ar putea să vă placă și