LIQUID Section:
Bulletin:
J100
J100.07
LEVEL GAGES Date:
Supercedes:
6/05
1/99
Series 300L
Specialists in Liquid Level Indication For Pressures Up To 300# ANSI
Nos. 63,143, Nos. 64,144, NOB. 66,146, NOB. 67,147, Nos. 63,143, Nos. 64,144, Nos. 146, 66 & 76Bl
I 73Bl,(93) 74Bl,(94) 76Bl 77Bl 73Bl,(93) 74Bl,(94) Nos. 147, 67 & nBl
.~
SPECIFICATIONS
SECTION LENGTHS:
~.-- 76 - ___-1
(3) Gage Sections are available
in six standard glass sizes.
Longer sizes are constructed
with multiple vision slots in a
continuous solid bar
chamber.
CONNECTIONS:
Standard connections are
at top and bottom and are
1f2 and % NPT female.
Optional connections are
available, such as socket
weld, flanged or close
hook-up (side/side)
LIQUID CHAMBER:
SERIES R-300L SERIES T-300L Machined from bar stock.
The gasket seat is recessed
to allow lateral support and
facilitate positioning.
COVERS:
Steel is standard. Optional
material are available. The
cushion gasket is recessed.
BOLTS & NUTS:
Steel fasteners, heat treated
for strength.
GLASS:
Tempered borosillicate is
used to 600 0 F (316° C)
Transparent glass may be
protected from corrosive
media with mica or Neoflon
CTFE.
GASKETS:
Standard gaskets are
precision die-cut in
proprietary Jerguson dies.
FINISH:
All steel parts are finish
coated prior to assembly.
Stainless steel is not coated.
VALVES
Use of Jerguson gage
valves is strongly
recommended. Standard
features include safety ball
checks which help prevent
loss of product and
physical injury in the event
of failure.
PRESSURE I TEMPERATURE RATINGS (PSIG) Note: Flanged gages are derated to flange rating.
Gasketing
Carbon Steel, Stainless Steel
Series 316 or 316L
Bonded Compressed Fibers
or Teflon Glass Filled
Monel Brass
Pure Teflon
Neoflon CTFE (Shields)
~
APPROVED MODELS
AVAILABLE.
Specify Gage Assemblies by the Figures Below
Flg.1 Flg.3 Flg.5 Flg.6 Flg.7 Flg.8
OFFSET OFFSET
INSIDE OUTSIDE
Nos. 63,143, Nos. 64,144, Nos. 66,146, Nos. 67,147, Nos. 63,143, Nos. 64,144, Nos. 146, 66 & 76BL
73BL,(93} 74BL,(94) 76BL 77BL 73BL,(93) 74BL,(94) Nos. 147, 67 & 77BL
SI:CTION LENGTHS:
Gage sections are available in nine
standard glass sizes. Longer sizes are
constructed with multiple vision slots in a
continuous solid bar chamber.
CONNECTIONS:
Standard connections are at top and
bottom and are 1, or %NPT female.
Optional connections are available, such
as socket weld, flanged or close hook-up
5/8 - ......., (side/side).
LIQUID CHAMBER:
Series R-20 Series T-20 Machined from bar stock. The gasket
seat is recessed to allow lateral support
Sect. Approximate Weight and facilitate positioning.
X
Size COVERS:
Forged carbon steel is standard.
Optional materials are available.
The cushion gasket seat is recessed.
GLASS:
Tempered Borosilicate is used to 600° F
(316°). Aluminosilicate is used to 800°
(427° C). Transparent glass may be
protected from corrosive media with mica
or Neoflon CTFE shields.
GASKETS:
Standard gaskets are precision die cut in
proprietary Jerguson dies.
FINISH:
All steel parts are finish coated prior to
assembly. Stainless steel is not coated.
VALVES:
Use of Jerguson gage valves is strong-
ly recommended. Standard features
include safety ball checks which help
prevent loss 'of product and physical
injury in the event of failure.
LIQUID Section:
Bulletin:
J100
J100.10
LEVEL GAGES Date:
Supercedes:
1/1/99
32
SERIES 32
Specialists in Liquid Level Indication For Pressures Up To 4000 psi @ 100°F
PRESSURE/TEMPERATURE RATINGS (PSIG) Note: Flanged gages are derated to flange rating .
.. For temperatures above SOO°F (31 SOC) Aluminosilicate Glass MUST be used.
% of Rating 100% 90% 50%
Chamber Material Carbon Steel, Stainless Steel Monel Brass
Series 316 or 316L
Gasketing Bonded Compressed Fibers Pure Teflon
or Teflon Glass Filled Neo/lon CTFE (Shields)
. .
Specify Gage Assemblies by the Figures Below
.
Flg.4
Fig.1 Fig.S Flg.6 Fig.7 Fig.S
OFFSET OFFSET
INSIDE OUTSIDE
Nos. 63,143, Nos. 64,144, Nos. 66,146, Nos. 67,147, Nos. 63,143, Nos. 64,144, Nos. 146, 66 & 76BL
73BL,(93) 74BL,(94) 76BL 77BL 73BL,(93) 74BL,(94) Nos. 147,67 & 77BL
SPECIFICATIONS
SECTION LENGTHS:
Gage sections are available
in nine standard glass sizes.
Longer sizes are constructed
with multiple vision slots in a
continuous solid bar cham-
ber.
CONNECTIONS:
I Standard connections are at
top and bottom and are 1. or
%NPT female. Optional con-
nections are available, such
as socket weld, flanged or
SERIES R-32 SERIES T-32 close hook-up (side/side).
Sect. Approximate Weight LIQUID CHAMBER:
X Machined from bar stock.
Size The gasket seat is recessed
to allow lateral support and
facilitate positioning.
COVERS:
Forged carbon steel is stan-
dard. Optional materials are
available. The cushion gas-
ket seat is recessed.
BOLTS & NUTS
Alloy steel is standard, A193
B7 and A 194 2H. Optional
materials are available. All
steel fasteners are "black
oxide" treated to prevent
rust.
GLASS:
Tempered Borosilicate is
used to 600° F (316°).
Aluminosilicate is used to
800° (427° C). Transparent
glass may be protected from
corrosive media with mica or
Neoflon CTFE shields.
GASKETS:
Standard gaskets are preci-
sion die cut in proprietary
Jerguson dies.
FINISH:
All steel parts are finish coat-
ed prior to assembly.
Stainless steel is not coated.
VALVES:
Use of Jerguson gage
valves is strongly recom-
mended. Standard features
include safety ball checks
which help prevent loss of
product and physical injury
in the event of failure.
LIQUID Section:
Bulletin:
J 100
J100.11
LEVEL GAGES Date:
Supercedes:
1/1/99
40
Series 40
Specialists in Liquid Level Indication For Pressures Up To 5000 psi @ 1OQ°F
Liquid Level Gages and Valves for the Power and Process Industries
NORTHEAST CONTROLS INC. TEL: 201-327-7660 | FAX: 201-327-3242 www.nciweb.com
LENGTHS:
Series 40 gages are avail-
able in nine standard visible
glass lengths. Multiples of
the same size windows in a
single piece bar stock liquid
chamber are used for longer
lengths.
CONNECTIONS:
Standard Series 40 gages
are furnished with W' female
end connections.
LIQUID CHAMBER:
Machined from bar stock with
recessed gasket seats.
COVERS:
SERIES R-40
SERIES T-40
Steel, recessed gasket seats.
BOLTS & NUTS:
Alloy steel to ASTM stan-
dards.
GLASS:
Tempered glass. The glass
must be protected from
mediums that are corrosive
to it such as caustic and -~
hydrofluoric acid. Trans-
parent glass with mica
shields mustbe used in these
applications.
GASKETS:
Precision die cut from high-
est quality materials.
NOTES:
It is recommended that all
gages be installed with
Jerguson gage valves hav-
ing safety ballchecks which
help provide protection
against physical injury and
loss of product if glass break-
age should occur.
NOTE:
R-40 Gages supplied with plain glass for
greater strength.
LIQUID Section:
Bulletin:
J100
J100.12
LEVEL GAGES Date:
Supercedes:
1/1/99
51
Series 51
Specialists in Liquid Level Indication For Pressures Up To 10,000 psi @ 10Q°F
Liquid Level Gages and Valves for the Power and Process Industries
NORTHEAST CONTROLS INC. TEL: 201-327-7660 | FAX: 201-327-3242 www.nciweb.com
1/2 N.P. T.
80TH ENDS Bill OF MATERIAL
PIECE
NO. NAME OF PIECE STANDARD MATERIAL
1 CHAMBER BAR STEEL
2 O-RING VI TON-A'
3 GLASS TEMPERED
4 CUSHION FIBROUS
5 COVER BAR STEEL
6 STUD ALLOY STEEL
7 NUT ALLOY STEEL
, OTHER COMPOUNDS TO SUIT APPLICATION ARE AVAILABLE.
SECTION x-x
LIQUID Section:
Bulletin:
J100
J100.13
LEVEL GAGES Date:
Supercedes:
1/1/99
10
Series L10
Specialists in Liquid Level Indication For Pressures Up To 2400 psi @ 100°F
PRESSURE·TEMPERATURE CHART FOR JERGUSON REFLEX GAGES PRESSURE-TEMPERATURE CHART FOR JERGUSON TRANSPARENT GAGES
Tem erature
. -. .. '
Glass Size Tom rature Glass Size
• F • C 1 2 3 4 5 6 7 8 9 • F • C 1 2 3 4 5 6 7 8 9
100 38 2400 2250 2100 1940 1800 1640 1500 1340 1200 100 38 1200 1110 1020 930 850 760 680 590 500
200 93 2220 2090 1950 1810 1670 1540 1400 1260 1130 200 93 1080 1000 920 840 760 680 600 530 450
300 149 2050 1920 1800 1680 1540 1430
H
1300 1180 1060 300 149 960 890 830 750 680 620 540 470 400
400 204 1860 1750 1640 1530 1420 1320 1200 1100 1000 400 204 850 670 600 540 480 420 360
500 260 1690 1600 1500 1400 1300 1210 1110 1010 920 500 260 730 570 520 470 420 360 310
600 316 1520 1430 1350 1260 1180 1100 1010 920 850 600 316 620 480 440 400 360 310 270
700 371 1340 1270 1200 1130 1060 990 920 850 780 700 371 500 470 430 400 360 330 290 260 220
BOO 427 1170 1110 1060 1000 940 880 830 770 710 800 427 390 360 340 310 290 260 230 210 180
SPECIFICATIONS
T
LENGTHS:
Series L-10 gages are avail-
able in nine standard visible
glass lengths. Multiple win-
dows on a single piece liquid
chamber are used for longer
lengths.
CONNECTIONS:
End connections with %"
N.P.T.arestandard. Upt02"
N.P.T. end connections, )1.;" or
%" N.P.T. side or back con-
nections and flanged con-
nections are available on
request.
Section: J 100
LIQUID Bulletin: J100.14
LEVEL GAGES Date:
Supercedes:
1/1/99
NF
Non-Frost Extensions
Specialists in Liquid Level Indication
AVAILABLE ON STANDARD OR
LARGE CHAMBER GAGES
Non-Frosting construction has been designed forthe Series
18,20,32, and L-10 Series gages.
Liquid Level Gages and Valves for the Power and Process Industries
NORTHEAST CONTROLS INC. TEL: 201-327-7660 | FAX: 201-327-3242 www.nciweb.com
-~-----
----11 r- 1/2
3-3/8
I
Ul
I
Series RF·20 Series TF·20
STANDARD WELDING PAD GAGES Materials and Construction: Jerguson Welding Pad Gages
are engineered and built to Jerguson's high standards, using
Design and Installation: Standard Jerguson welding pad materials found by test to be the best for the particular appli-
gages follow other Jerguson flat glass gages in general cation. The welding pad may be made of any material desired
design and materials, except for the method of attaching to to withstand corrosive or other conditions.
the tank or vessel. The chamber of the welding pad gage
consists of a bar stock pad, which is welded to the tank after To prevent distortion during welding, welding pad gages may
cutting a slot in the tank wall equal in dimension to the vision be furnished with a cold rolled steel spacer to replace glass
and gaskets.
slot of the gage. Alternately, for maximum vessel strength
without further reinforcement, two holes may be drilled in:the ISOlABlE WELDING PAD GAGES
tank wall with diameters equal to the width of the vision slot
of the gage located at the top and the bottom of the visible Jerguson Isolable Welding Pad Gages with integral valves fol-
range. For best results the tank wall behind a reflex gage low the general design of standard Jerguson welding pad
gages but offer the additional advantages of integral valves.
should provide a dark background. The holes, in lieu of the
slot method, can be used with the transparent type gage if Because the gage can be isolated from the vessel by the
there is sufficient visual contrast between the tank and the v~lves, gaskets or glass can be replaced without lowering the
liquid to permit liquid level or interface observation. level of liquid below the gage inlet or relieving pressure from
the vessel.
Pressure Loads: Where it is necessary to slot the tank Isolable gages are installed by matching the valve inlets with
because of the nature of the liquid or there is need to observe holes drilled in the vessel and making a 100% fillet weld
the color or interface of the liquid, the following facts must between the vessel wall and the valve inlets. The gage cham-
be considered: ber is tack welded to the vessel.
Standard welding pad gages will withstand loadings due to
the pressure within the gage itself, but they are not designed
to replace the tank strength lost when the tank wall is cut.
The gage manufacturer has no control over the loading which
the pressure vessel will impose on the pad. It is therefore
impossible to rate welding pad gages. The tank fabricator
must provide suitable tank wall reinforcement to prevent the
pad from being distorted during welding or while under oper-
~ ating conditions.
Liquid Level Gages and Valves for the Power and Process Industries
NORTHEAST CONTROLS INC. TEL: 201-327-7660 | FAX: 201-327-3242 www.nciweb.com
The maximum pressure rating of RW & TW weld pad gages corresponds to the maximum pressure rating of Series 300L and 20 transparent gages on bulletins Jl 00.07
& J100.09, provided the vessel thickness and reinforcement are adequate to withstand such pressures. ~
t
1" SER. 300L
RW-20 OR TW-20
Number of Sections
1" SER. 20 Cap
~
I
go
3000
2000
11
ISOlABlE WELDING PAD GAGES
::
::
S,i.RIES 20
SERIES 300l
1600 psi @ 100'F
15
18
RIW 300L or TIW 300L
No.of Visible
Size Bolts Glass
No. ISect. In Inches
18
22
14}\
17}\
1
Number of Sections
Overall Length In Inches
19%
22%
2
35%
41%
3 4
51% 67'Al
60% 79'10
1000 750' 1200 psi @ 500'F
SIZE 123456789 20 24 19X 24% 45% 66% 87'Al
1,/,'
SER. 300L OR 20
RIW-20 OR TIW-20
Number of Sections
Cap
Size Screws Visible
Overall Length In Inches
No. ISect. Glass 1 2 3 4 5 6 7 8 9
1 6 3% 8% 14 19X 24lf 29% 35 40X 45lf 50%
2 6 4% 9% 16 22X 28lf 34% 41 47Y. 53lf 59%
3 8 5% 10% 18 25X 32ll! 39% 47 54X 61ll! 68%
4 10 6% 11% 20 28Y. 36lf 44% 53 61X 69ll! 77%
RIW 300L or 20 5 10 7% 12% 22X 31% 41 50% 59% 691' 78ll! 87%
Cross Section 6 12 91' 141' 24% 35% 46 56% 67X 77% 88lf 991'
7 14 lOX 15X 27 38% 50lf 62X 74 85% 97lf 109X
8 16 11 % 16% 30X 43% 57 70% 83% 97~ 110lf 123'10
9 18 12% 17% 31% 45% 60 74li 88X 102% 116lf 130%
Section: J100
LIQUID Bulletin: J100.16
Date: 11/1/03
LEVEL GAGES Supercedes: 1/1/99
1
,,.
5112
Dim. Dim. Quan. Per Sec. Dim. Dim. Quan. Per Sec. Dim. Dim. Quan. Per Sec.
Gage Size A B U-Bolt Nut Rating Gage Size A B U-Bolt Nut Rating Gage Size A B BoH Nut Rating
Liquid Level Gages and Valves for the ower and Process Industries
NORTHEAST CONTROLS INC. TEL: 201-327-7660 | FAX: 201-327-3242 www.nciweb.com
Dim. Dim. Quan. Per Sec. Dim. Dim. Dim. Quan./Sec. Dim. Dim. Dim. Quan.lSec.
Gage Size A B Bolt Nut Rating Gage Size A B C Bolt Nut Rating Gage Size A B C Bott Nut Rating
lHM·32 16 6% 4% 10 a:
0
en to 15·TM·40 18 7% 4)\6 10 a:w to
15·TM-32 17 Tia 4% 10 w 750W.S.P. 16-TM-40 20 9 50/,6 12 CL 1500W.S.P.
For pressures in the 600 WSP range, most CL
~
operators prefer to see no threaded con- 16·TM·32 18 9% 4 12 17·TM-40 21 10% 5X6 14
nection between the flanged vessel con- lHM-32 19 10% 3'1a 14 18-TM·40 22 11% 4Y,6 16
nection and the valve seat. The No. 67 18·TM·32 21 11% 4% 16 19·TM-40 23 12lf 4'X6 16
valves illustrated have this feature. The ver- 19·TM·32 22 12% 4~ 16
tical rising ballcheck is downstream from the For this high pressure series Jerguson rec-
seat providing accessibility without the Thermal stresses caused by temperatures ommends a 74-H valve which is specially
necessity of disassembling the valve. prevalent at operating pressures of 750 designed for high pressure steam service.
WSP are such to make it advisable to fur- The stem has Acme threads to allow easier
When mliitiple section gages are used, nish a built-in expansion loop. This will take opening and stem operation, a loose knob
expansion loops are suggested to relieve up any differential in expansion rate construction for the disc and a stellited seat.
piping strain. between the vessel and gage glass elimi- The special spring washers used under the
nating stresses in the assembly. gage nuts absorb expansion and contraction
and maintain the proper clamping load of the
cover without retorquing the nuts.
Liquid Level Gages and Valves for the Power and Process Industries
NORTHEAST CONTROLS INC. TEL: 201-327-7660 | FAX: 201-327-3242 www.nciweb.com
Section: J100
ILLUMINATORS Bulletin: J100.31
Date: 1/1/99
& ACCESSORIES Supercedes: GA
B Service.
Relamping of these illuminators is simple and quick. A sin-
gle wing-nut clamps the cover and glass housing in place.
Loosening of the nut permits the cover and housing to lift
out in one piece. A safety chain attaching the bulb housing
to the base prevents possible damage and loss of parts on
the EPL-56.
Illuminators are made in single and double section styles
for Jerguson Series 300L, 20, 32 and L-10 gages. Double
section gages require only one lamp for illumination of two
gage sections. They can be adapted for use of Non-Frosting
Transparent Gages, and Reflex Gages.
EPL-54 and EPL-56 use a medium base 58 watt bulb.
EASY TO INSTALL
ELP-54
It is easy to install Jerguson Illuminators on your present
gages or new gages. The illuminators are furnished with
brackets which mount on the top two cover bolts on the right-
hand side of the gage section. The explosion-proof fitting
bolts to the bracket.
~
A VISION SLOT Of GAGE EPL-56 ILLUMINATOR ASSEMBLY A-7777 A-7778
EPL-56 ILLUUINATOR HOUSING ASSEUBLY 5-3820
BLENGTH or SINGLE SECTION illUMINATOR (LESS WEDGE. REFLECTOR. AND BRACKET)
Liquid Level Gages and Valves for the Power and Process Industries
NORTHEAST CONTROLS INC. TEL: 201-327-7660 | FAX: 201-327-3242 www.nciweb.com
[f- (0 ~1~~~IIIII~IIIIJJ1j)I~IIII~IIIII~llt:le 0) t
- --L
MOUNTING BRACKETS FOR USE WITH FLAT GLASS
GAGES OR TUBULAR VALVES CAN BE FURNISHED.
TYPE 1
CAMPBELL'S FOOT SCALE, PRESSURE CAST, WEATHER-RESIS-
TANT ZINC ALLOY, FURNISHED IN IDENTICAL ONE FOOT STRIPS
WITH NUMBERED COUPLING PLATES TO BE ASSEMBLED BY CUS-
TOMER TO ANY DESIRED LENGTH. GRADUATED IN FEET, INCHES
AND EIGHTHS OF AN INCH.
• Maintenance FREE
• Long Life - 100,000 hrs. "I purchased some 50 units of ELP-1 00 Illuminators for Chevron's Hawaii Refinery.
The operators are very pleased with this unit as it radiates a tremendous amount of
• No Heat Generation lighting through the gage glasses unlike the older incandescent types we had here.
This makes for verifying levels in columns, vessels, drums, etc. much easier. This is
a good product and suited our needs perfectly. "
• Field Upgradable - Darrin M. Matsumiya, liE Supervisor/Analyst at Chevron Texaco Hawaii
- Fits Any Glass Gage!
SPECIFICATIONS
• Eliminates "bulb-changes" Power Supply: 120 or 240 VAC @ 50-60 Hz
Power Consumption: < 750 mA@ 120 VAC
• Longest Field-of-View < 375 mA@ 240 VAC
JERGUSON® is pleased to announce the addition of the LumaStar gage glass illuminator to the world's
largest selection of level indication and control products. JERGUSON's model EPL-100 is approved
for use in Class I, Div I, Group B, C & D environments. Available in any size up to 55" long with a
single power supply. That means a four section, size nine gage from a single power supply at less
than 750 rnA! Contact your local representative or a Jerguson Applications Engineer to configure an
LumaStar EPL-1 00 for your transparent glass level gages.
«I
EPL-100-7 5 591/4 1505 10.1
~
T
L-Blank = Standard
LumaStar, Model ELP-100
=
D Daisy Chain
115 or 230 VAC 50/60 Hz (For multiple single sections connected with
armored cable, consult factory for maximum
FM Class I, Div I, Groups B, C, D
lengths and number of sections)
Nema 4,7
4x Mounting Brackets
Gage Window Size ( 1 thru 9 or 13 thru 20 ) - - - - - - ' 1 = Series 20/32 CS Covers
2 = Series 20/32 SS Covers, 300L CS/SS
Prewired Terminal Connections - - - - - - - '
=
3 Series 12 (Obsolete)
4 = Series 20/32 CS Covers NF Ext.
=
1 115 VAC 50/60 Hz 5 = Series 20/32 SS Covers NF Ext.
=
2 240 VAC 50/60 Hz
=
6 Series 30
=
7 Reliance FG450 / 900
Number of Gage Sections (1,2, 3,4) - - - - - - - - - ' 8 = Reliance FG1500
9 = Series 40 / Boiler Water Gages
10 = Penberthy M Series
11 = Jogler
Section: J100
SPARE PARTS Bulletin: J100.35
For Reflex or Transparent Standard Date: 1211/99
I Size 1 through 9 Glass Supercedes: NEW
Specialists in Liquid Level Indication I
--II-- 0.06"
Glass Dimension "A"
~"''' 1.6mm
F=========~--'---(~~ Size
Inches mm
4.5 115
2 5.5 140
Polish
5 8.625 220
6 9.875 250
7 11 280
Polish 8 12.625 320
~-'--------- A ------_-1 9 13.375 340
i
P-6082-X CTFE CTFE Shi Id (formerly known as Kel-F). A sealing gasket is not used with this.
Nitrile Bound Standard IGasket, suitable for most hydrocarbon service. (Replaces the obsolete V-
V-18980-X
Aramid Fiber 17351-X.1 The material is identical.)
SS Reinforced Jerguson Ihas extensively tested un-reinforced graphite, and has found that it will not
V-13143-X
Graphite hold up iri pressure cycling conditions, and is not recommended.
V-7858-X TFE Low-Flo,,", TFE gasket. This is designed to reduce cold flow associated with solid TFE.
Note: Replace "X" in all Part Numbers with the Gla ~s Size. Parts supplied by sources other than Jerguson may void stamped
pressure ratin g.