BSC6900 GBAM-to-GOMU

Replacement Guide

Issue

Date

HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2010. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions


and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.

All other trademarks and trade names mentioned in this document are the property of their respective
holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website: http://www.huawei.com

Email: support@huawei.com

2019-9-8 Huawei Proprietary and Confidential i


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide Change History

Change History

Version Description Release Date Author Approved by

1.0 First release 2011-3-30 Tang Xiangui


1.1 2011-8-5 Tang Xiangui
1.2 Bug fix 2012-5-7 Tang Xiangui

2019-9-8 Huawei Proprietary and Confidential ii


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide Contents

Contents

1 Overview.........................................................................................................................................1
2 Check Before the Operation........................................................................................................2
2.1 Checking the Running Status of a Board...........................................................................................................2
2.2 Checking alarms................................................................................................................................................2

3 Preparation......................................................................................................................................3
3.1 Preparing the Required Hardware......................................................................................................................3
3.2 Preparing the Software Required for the Replacement......................................................................................3
3.3 Planning the Slots of the OMU Board...............................................................................................................3
3.4 Backing Up Data Before the Replacement........................................................................................................3
3.4.1 Online Data Backup..................................................................................................................................4
3.4.2 Preparing Offline Data..............................................................................................................................7

4 Procedure.........................................................................................................................................8
4.1 Stopping the GBAM..........................................................................................................................................8
4.2 Installing the GOMU.........................................................................................................................................8
4.2.1 Installing the Hardware of the GOMU.....................................................................................................8
4.2.2 Installing the Software of the GOMU......................................................................................................8
4.2.3 Recovering Data.....................................................................................................................................14
4.2.4 Installing the Standby OMU...................................................................................................................16

5 Verification After the Replacement.........................................................................................17


6 GBAM Rollback..........................................................................................................................18
6.1 Stopping the Running of the GOMU...............................................................................................................18
6.2 Recovering the GBAM Connection.................................................................................................................18
6.3 Starting the GBAM..........................................................................................................................................18

7 Appendix.......................................................................................................................................19
7.1 Common Commands of the psftp Software.....................................................................................................19

2019-9-8 Huawei Proprietary and Confidential iii


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide OverviewOverview

1 Overview

This guide helps you to replace the GBAM server with the GOMU and is applicable to the
following two scenarios:
 The GBAM is not fully damaged and you can back up data on line.
 The GBAM is fully damaged and you cannot back up data on line (there must be backup
database files).

The operations in this guide must be performed locally.


You must stop the OMU during the operation. Therefore, communication between back
administration module (BAM) and front administration module (FAM) is interrupted,
and communication between the LMT/M2000 and BSC host system is interrupted. In
this case, you cannot maintain the BSC host system or collect the information such as
alarms; however, the BSC host system operates normally.
Electron devices are vulnerable to ESD impairment. Wear an ESD wrist strap correctly
before the installation, and connect the ESD wrist strap to the ground point (the ESD
jack on the cabinet).

2019-9-8 Huawei Proprietary and Confidential 1


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide Check Before the OperationCheck Before the Operation

2 Check Before the Operation

2.1 Checking the Running Status of a Board

If the GBAM is damaged and you cannot check on line, skip the operation described in this section.

Before the operation, check the running status of the board. The procedure is as follows:
1. Log in to the Web LMT on line.
2. Click the Device Maintenance tab on the main interface of the LMT.
3. Check the running status of the board in each subrack. If the board is abnormal, stop the
operation, and then contact Huawei technical engineers.

2.2 Checking alarms


To check the alarm information, do as follows:
4. Log in to the Web LMT.
5. On the main interface of the LMT, click Alarm. The Alarm tab is displayed. The Fault,
Event, and Engineering tabs are contained on the Browse Alarm tab.
6. Browse the alarm information on the Browse Alarm tab. If abnormal alarms exist, stop the
operation, and then handle the fault according to the instruction of the alarm help. If the fault
persists, contact Huawei technical support engineers.

2019-9-8 Huawei Proprietary and Confidential 2


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide PreparationPreparation

3 Preparation

3.1 Preparing the Required Hardware


 Tools for the replacement are prepared, including electrostatic discharge (ESD) wrist
straps, Phillips screwdrivers, flat-head screwdrivers, wrenches, knives, and an ESD box
or ESD bag.
 The spare parts of the GOMU are prepared.

3.2 Preparing the Software Required for the Replacement


Prepare the OMU application installation package (including the patch installation package)
and psftp tool.
7. To obtain the OMU application installation package, visit http://support.huawei.com/support/,
and then choose Software center > Version Software > Wireless Product Line > Single
RAN > MBSC > BSC6900 > BSC6900.
8. To download the psftp file, visit http://support.huawei.com/support/, and then choose
Software center > Mini-tool software > Core Network product Line > Genex CN Nastar
TOOL > Tool for remote login linux.

3.3 Planning the Slots of the OMU Board


The OMUa/OMUb board is installed in slots 0–1, 2–3, 20–21, 22–23, 24–25, or 26–27 of the
MPS subrack. Each GOMU occupies two slots. Before replacing the GBAM server with the
GOMU, check whether there are vacant slots for the GOMU. If there is no vacant slot, adjust
the configuration data and move the board before replacing with the GOMU.

2019-9-8 Huawei Proprietary and Confidential 3


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide PreparationPreparation

3.4 Backing Up Data Before the Replacement

 If the GBAM is not fully damaged and O&M operations can be performed, online data
backup is recommended.
 If the GBAM is damaged and you cannot maintain data, prepare data offline.

3.4.1 Online Data Backup


To back up data on line, do as follows:
9. Planning the IP Address and gateway
To obtain the IP address and gateway information, do as follows:
a. Log in to the Web LMT, and then run the DSP OMU command. The computer name of
the GBAM server, external fixed IP address ,internal virtual IP address ,external network
virtual IP address and external network mask are obtained.

If the external network fixed IP address is not configured, the system displays NULL. In this case,
Huawei engineers need to apply for an IP address from the customer, and this IP address is in the same
network segment as the external network virtual IP address for the fixed IP address of the external
network.
b. Log in to the PuTTY, and then run the route command of the Linux operating system.
The default gateway address of the GBAM server are obtained.
c. Planning the IP Address for GOMU board.
Plan the IP address of the OMU according to the IP address of the GBAM and the planning
rules of each IP address (see Table 1.1).

Table 1.1 Planning rules


OMU IP Address Planning Principle

External fixed IP  The external fixed IP address and the external virtual IP address of
address the OMU must be in the same network segment.
 The external fixed IP address of the OMU must not conflict with
the IP addresses of other devices.
Internal fixed IP  The internal fixed IP addresses of the active and standby OMUs
address must be in the same network segment and different from each other.
 The internal fixed IP addresses of the active and standby OMUs
must be XY.168.3.50 and XY.168.3.60 respectively. The mask must
be 255.0.0.0.
 The default XY network segment is 80. This network segment can
be changed but must be consistent with that of the internal virtual IP
address. After changing the network segment, you must reset the
BSC. Other network segments must not be changed.
 Two IP addresses can be flexibly allocated to the active and standby
OMUs.

2019-9-8 Huawei Proprietary and Confidential 4


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide PreparationPreparation

Internal virtual IP  The internal virtual IP addresses of the active and standby OMUs
address must be XY.168.3.40. The mask must be 255.0.0.0.
 The default XY network segment is 80. This network segment can
be changed but must be consistent with that of the internal fixed IP
address. After changing the network segment, you must reset the
BSC. Other network segments must not be changed.
Backup path IP  The backup path IP addresses of the active and standby OMUs must
address be in the same network segment and different from each other.
 The default backup path IP addresses of the active and standby
OMUs are XY.168.3.50 and XY.168.3.60 respectively. The mask is
255.255.255.0.
 During an upgrade from the BSC6000, the backup path IP addresses
before and after the upgrade must be consistent. The default backup
path IP address is XY.168.10.XXX. The mask is 255.255.255.0.
 The default XY network segment is 192. This network segment can
be changed. Other network segments must not be changed.

10. Obtain the directory of the current workarea.


To obtain the directory of the current workarea, log in to the PuTTY, and then run the ps -afx |
grep monitor command.
The workarea is version_a and is in the /BSC6000/data/mbsc/bam/version_a directory, as
shown in Figure a.1.

Figure a.1 Directory of the workarea

11. Back up the database file


To back up the database file of the OMU, run the BKP DB command. After the database file
is backed up, the path of the backup database file is displayed. By default, the backup
database file is stored in the OMU workarea directory/data/backup directory.
12. Dump the data file to a local system.
To dump the data file to a local system, do as follows:
a. Create a local backup directory. Create a directory named backup on a local personal
computer (PC) to store the related documents of the GBAM server. The capacity of the
directory space must be about one GB. Then create child directories in the backup
directory, and name the child directories data, license, DefaultMeas, and cert.
b. Log in to the Web LMT, and then start the file manager.
c. Download the backup database file, performance task file, SSL certificate file, and
license file to the corresponding directory of the local computer. It is recommended that
the database file is renamed omudata.bak after it is stored in the local computer.

2019-9-8 Huawei Proprietary and Confidential 5


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide PreparationPreparation

Directory of the performance task configuration file: \bam\workarea\ftp\DefaultMeas


Directory of the SSL certificate file: \bam\workarea\ftp\cert
Directory of the license file: \bam\workarea\ftp\license

To download the backup data file, do as follows:


1. Select the directory of the file in the left navigation tree.

2. Click Download.

3. Select a local directory to save the file.

2019-9-8 Huawei Proprietary and Confidential 6


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide PreparationPreparation

After the file is downloaded, download other files to be backed up.

3.4.2 Preparing Offline Data


4. If the GBAM is fully damaged and you cannot maintain data, prepare the latest database file,
license file, and Planning the IP Address and gateway(see 9.cTable 1.1).

2019-9-8 Huawei Proprietary and Confidential 7


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide ProcedureProcedure

4 Procedure

4.1 Stopping the GBAM


To stop the GBAM, do as follows:
5. To stop the running of the OMU on the GBAM server, log in to the GBAM server by using
the PuTTY, and then run the command /etc/rc.d/omud stop.
6. Run the poweroff command. The GBAM server to be replaced is powered off.
7. Remove the network cable connected to the GBAM.

4.2 Installing the GOMU


4.2.1 Installing the Hardware of the GOMU
8. Insert the OMU board.
Insert the OMU board with an operating system into the OMU slot and connect the external
network port cables.
9. Upgrade the driver.
Log in to http://support.huawei.com/support. Choose Software center > Version software >
Wireless Product Line > Single RAN > SRAN O&M tools to obtain the OMU Driver
Upgrade software package. Then, install the obtained software package.

4.2.2 Installing the Software of the GOMU


To install the software of the GOMU, do as follows:
10. Upload the OMU software to the GOMU.
To upload the OMU software to the GOMU, do as follows:
a. Decompress the BSC6900 version installation package to the local system. If there is a
patch, copy the patch file to the patch folder in the local directory of the installation
package. After the installation, the patch is installed.

2019-9-8 Huawei Proprietary and Confidential 8


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide ProcedureProcedure

The methods for uploading patch packages vary with versions.

V900R011 version
Copy the .PAT and Patchcfg.xml files (if available) in the patch package to the patch
folder under the directory for storing the installation package on the local PC. If the .PAT
file name does not match the actual internal version, change the .PAT file name to be the
same as the version.
For example, to upload V900R011C00SPH732, do as follows: Decompress the
V900R011C00SPC700 installation package to the local PC, find the installation folder
V900R011C00SPC700, and then decompress the V900R011C00SPH732 patch package
to obtain the V900R011C00SPH728_1.PAT file. Then, copy the file to the patch folder
under the V900R011C00SPC700 directory and change the file name to
V900R011C00SPH728.PAT.

V900R012 、V900R013 version


Copy the installation file of the patch package to the patch folder under the directory for
storing the installation package.
For example, to upload V900R012C01SPH512, do as follows: Decompress the
V900R012C01SPC500 installation package to a local PC, find the installation folder
V900R012C01SPC500. Then, decompress the V900R012C01SPH512 patch package
and copy the patch installation folder V900R012C01SPH512 to the patch folder under
the V900R012C01SPC500 directory.

b. Locally connect to the ETH2 debugging network port of the GOMU, and then run the
psftp. Log in to the GOMU by using the debugging IP address.
Run the psftp, run the open login IP address command, and then log in by using the
user root. For example, run the open 192.168.6.50 command.

For the OMU that is newly delivered, the default debugging IP address of the OMUa is 192.168.6.50 or
192.168.6.60, and the default debugging IP address of the OMUb is 192.168.1.1.
For the common commands of the psftp, see Appendix 1.
c. Switch to the local directory for uploading
To switch over to the local PC directory of the version installation package, run the lcd
local directory command in the login window of the psftp. For example, run the lcd D:\
command if the installation package is stored in the D disk root directory, as shown in
Figure c.1.

2019-9-8 Huawei Proprietary and Confidential 9


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide ProcedureProcedure

Figure c.1 Switching over the directory

d. Determine the installation partition of the OMU.


To determine the partition of the OMU installation, log in to the PuTTY, and then run the df
-h command. The area of the /BSC6000/data directory has the largest free space, as shown in
Figure d.1. Therefore, the GOMU software is installed in the directory.

Figure d.1 Installation partition of the OMU

 To ensure the normal running of the software, the OMU must be installed in the area with the largest
space. The default partitions of the OMUa and OMUb are different. Therefore, determine the
installation partition of the OMU first.
 For the OMUa, the area with the largest space is in the /mbsc directory. For the OMUb, the area
with the largest space is in the /BSC6000/data directory.
e. Create the software installation directory of the GOMU.
To create the software installation directory of the GOMU, do as follows:
 Check whether the OMU software installation directory mbsc/upgrade exists on the
GOMU.
Then run the ls /mbsc/upgrade command in the login window of the psftp.
If a message saying “no such file or directory” is displayed, the directory does not exist,
as shown in Figure e.1.

Figure e.1 Checking whether a directory exists

If the directory with the largest free space of the GOMU is the /BSC6000/data directory, the directory to
be checked is /BSC6000/data/mbsc/upgrade.Run the ls /BSC6000/data/mbsc/upgrade command.
 Then you need to create a corresponding directory manually. Run the mkdir directory
name command. When you create a directory, create a parent directory when the parent
directory does not exist. Then create a child directory. For example, to create a
/mbsc/upgrade directory, do as follows:
Run the mkdir /mbsc command. The parent directory /mbsc is created.

2019-9-8 Huawei Proprietary and Confidential 10


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide ProcedureProcedure

Then run the mkdir /mbsc/upgrade command. The child directory /mbsc/upgrade is
created, as shown in Figure e.2.

Figure e.2 Creating parent and child directories

 If the directory with the largest free space of the GOMU is /BSC6000/data, you need to create the
mbsc/data directory in the /BSC6000/data/ directory.
 Run the mkdir /BSC6000/data/mbsc command. The parent directory /BSC6000/data /mbsc/ is
created.
 Run the mkdir /BSC6000/data/mbsc/upgrade command. The child directory /BSC6000/data
/mbsc/upgrade is created.
f. Switch to the OMU directory.
To switch to the directory of the OMU to the /mbsc/upgrade directory of the OMU
software installation directory.
Run the cd /mbsc/upgrade command in the login window of the psftp, as shown in
Figure f.1.

Figure f.1 Switching over to the /mbsc/upgrade directory of the OMU software installation
directory

If the mbsc directory is in the /BSC6000/data directory, run the cd /BSC6000/data/mbsc/upgrade


command. The directory of the OMU is switched to the /BSC6000/data/mbsc/upgrade directory.
g. Upload the version package to the OMU directory.
Run the put -r V900R011C00SPC700 command in the login window of the psftp, as
shown in Figure g.1.

Figure g.1 Uploading the version package to the OMU directory

11. Install the OMU software on the GOMU.


To install the OMU software on the GOMU, do as follows:

2019-9-8 Huawei Proprietary and Confidential 11


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide ProcedureProcedure

a. Log in to the GOMU by using the PuTTY, switch the directory to the path of the
installation program, that is, /mbsc/upgrade/V900R011C00SPC700/install/setup, and
then run the cd /mbsc/upgrade/V900R011C00SPC700/install/setup command.

If the mbsc directory is in the /BSC6000/data directory, run the cd


/BSC6000/data/mbsc/upgrade/V900R011C00SPC700/install/setup command. The directory is switched
to the /BSC6000/data/mbsc/upgrade/V900R011C00SPC700/install/setup directory.
b. Run the chmod +x ./install_bam.sh command. The right of running the
./install_bam.sh command is obtained.
c. Run the ./install_bam.sh command to install the OMU.
d. Configure the OMU.
You must configure the OMU when the installation of the OMU software starts, The
configuration must be consistent with that of the GBAM. The configuration items are as
follows:
Product service mode
# The run mode of the product
# GO:GSM only
# UO:UMTS only
# GU:GSM and UMTS
# Please select one mode to install.
Please input a valid run_mode :

Computer name
# The name of office
# The name suggest range from 5 to 32 characters.
# The characters suggest be letters, digits, "-"or "_".
Please input a valid office_name :

Language information
# The OMU language version. eg: eng/chs
Please input a valid version :

Administrator’s password
# The "admin" user's password of OMU service.
# The password must range from 6 to 32 characters and consist of only letters
and figures.
# Do not forget the password.
# You can change the password later, but this password should be provided
first.
Please input a valid admin_password :

The administrator’s password is the initial password when the administrator log in to the LMT.
FTP password
# The ftp user's password of OMU service
# The password must range from 6 to 32(characters) and consist of only letters
and figures.
# Do not forget the password.
# You can change it later, but this password should be provided first.
Please input a valid ftp_password:

Users customize the FTP password. After the OMU application is installed, use the FTP password to
access the FTP service of the OMU.

2019-9-8 Huawei Proprietary and Confidential 12


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide ProcedureProcedure

External network virtual IP address


# The virtual extranet ip.
Please input a valid virtual_extranet_ip:

 If the existing external fixed IP address and the planned IP address are not in the same network
segment, the verification of the external virtual IP address configured during the OMU
software installation process may fail. If the verification fails, configure an external virtual IP
address in the same network segment as the existing external fixed IP address. After the installation,
run omutool to change the external fixed IP address and external virtual IP address to correct values.
 The existing external fixed IP address can be queried by running ifconfig bond1 in PuTTY.
 Input external virtual IP /netmask;gateway IP when the external fixed IP address not exist”
OMU installation type: Enter single.
# The OMU system type. eg: Single/Dual
# Single:Install stand-alone system
# Dual:Install dual-OMU system.
The dual-OMU system can efficiently increase the reliability of the OMU
system.
Please input a valid install_type:

e. Confirm the installation.


To install the OMU application, type Y. When a message saying "Install OMU succeed!"
is displayed on the interface, the OMU application is installed.
Please affirm input information. input Y to continue; input E to exit. ->

12. Configure IP address and gateway


Planning the IP Address for GOMU board(see 9.cTable 1.1).
a. switch to path of the omutool
Run the cd command to switch to the mbsc/bam/version_a/bin/bam path of the omutool
program, for example, cd /mbsc/bam/version_a/bin/bam.

If the mbsc directory is in the /BSC6000/data directory, run the command


cd /BSC6000/data/mbsc/bam/version_a/bin/bam.
b. configure the external network IP
To configure the external network virtual IP address, run the ./omutool extervip
external network virtual IP address subnet mask command on the PuTTY, for
example, the ./omutool extervip 10.161.10.102 255.255.255.0 command.
To configure the external network fixed IP address, run the ./omutool extercard
external network fixed IP address subnet mask command on the PuTTY, for example,
the ./omutool extercard 10.161.10.100 255.255.255.0 command.
To configure the gateway, run the ./omutool gateway gateway IP address command on
the PuTTY, for example, the ./omutool gateway 10.161.10.1 command.
c. configure the internal network IP
To configure the internal network virtual IP address, run the ./omutool innervip internal
network virtual IP address subnet mask command on the PuTTY, for example, the
./omutool innervip 80.168.3.40 255.0.0.0 command.
To configure the internal network fixed IP address, run the ./omutool innercard internal
network fixed IP address subnet mask command on the PuTTY, for example, the
./omutool innercard 80.168.3.50 255.0.0.0 command.

2019-9-8 Huawei Proprietary and Confidential 13


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide ProcedureProcedure

The subnet masks of both the internal fixed IP address and internal virtual IP address must be 255.0.0.0.
If the subnet mask is not 255.0.0.0, the internal network address of the OMU may conflict with the IP
address of the host board.
For V900R013C00SPH532 and later version,can not set the subnetmask of inner IP address and bakup
network IP address.

To configure the backup network IP address, run the ./omutool backupcard backup
network IP address subnet mask command on the PuTTY, for example, the ./omutool
backupcard 192.168.3.50 255.255.255.0 command.
d. Start the OMU.
To start the OMU, run the command /etc/rc.d/omud start on the PuTTY.
e. If the OMU version is a patch version, log in to the OMU by using the Web LMT, and
then run the INS PATCH command. If a message saying "No new patch packet was
found." or saying "Execute Succeeded." is displayed, it is normal.

4.2.3 Recovering Data


To recover data, do as follows:
13. Upload data files.

If the data is prepared offline, you must upload the database file. You may not upload the following data
files that are not backed up.
a. Log in to the GOMU by using the Web LMT, and then start the file manager.
b. Recover the license file.
Upload all files in the backup/license directory of the PC to the
bam/version_a/ftp/license directory of the GOMU by using the file manager.
c. Recover the performance task file.
Upload all files in the backup/DefaultMeas directory of the PC to the
bam/version_a/ftp/DefaultMeas directory of the GOMU. If a massage indicating that
the file exists, delete the file with the same name on the GOMU first.
d. Recover the certificate file.
Upload all files in the backup/cert directory of the PC to the bam/version_a/ftp/cert
directory of the OMU by using the file manager.
e. Upload the database file.
Upload the backup database file in the backup/data directory of the PC to the bam
directory.
14. Recover the database file.
To recover the database file, do as follows:
a. Stop the OMU.
To stop the OMU, log in to the PuTTY, and then run the /etc/rc.d/omud stop command.
b. Recover the database file.
To recover the database file, log in to the PuTTY, switch to the
mbsc/bam/common/services directory, and then run the cd
/mbsc/bam/common/services command.

2019-9-8 Huawei Proprietary and Confidential 14


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide ProcedureProcedure

If the OMU software is installed in the /BSC6000/data directory, you must run the cd
/BSC6000/data/mbsc/bam/common/services command to switch to the
/BSC6000/data/mbsc/bam/common/services directory.

To recover the data of the OMU by using the omu_backup_linker tool, run the
/omu_backup_linker command.
A massage saying "Please input a valid bkp_res_type" is displayed on the interface. Type
restore, and then press Enter, as shown in Figure b.1.

Figure b.1 Recovering the data of the OMU

A massage saying "Please input a valid backup file pathname:" is displayed on the interface.
Type the path and name of the backup database file, and then press Enter, as shown in Figure
b.2.

Database files are uploaded to the Bam directory through the file manager. The absolute path of the
corresponding operating system is /mbsc/bam. If the OMU software is installed in the /BSC6000/data
directory, the absolute path of the corresponding operating system is /BSC6000/data/mbsc/bam.

Figure b.2 Typing the path and name of the backup database file

The system recovers its data and displays the success or failure of the data recovery on the
screen. When the data is recovered successfully, a message saying "Restore OMU database
succeed!" is displayed, as shown in Figure b.3.

Figure b.3 Successfully restoring data

15. Check the running status of the OMU.


To check the running status of the OMU, do as follows:
a. Start the OMU.
To stop the OMU, log in to the PuTTY, and then run the command /etc/rc.d/omud start.
b. Log in to the Web LMT, and then run the DSP OMU command. Check the status of the
new board again and check whether all IP addresses are correct.
c. Run the DSP OMUMODULE command. Query the status of the OMU service.

2019-9-8 Huawei Proprietary and Confidential 15


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide ProcedureProcedure

Status of Active OMU and Required Existing Process


Standby OMU

Active OMU host_gate, ems_gate, authority, configure, maintain, stat,


alarm, software, ftp_server, sntp, btsom, ems_agent,
omu_manager, cfa, WebLmt, and debug_log.

Standby OMU software, ftp_server, sntp, omu_manager, and debug_log.

d. Run the DSP BRD command. Check whether the status of the OMU is normal.
e. When the OMU operates normally, run the ADD BRD command. Add the configuration
information of the GOMU.
f. Run the SET SCUPORT command. The port 10 and port 11 of the SCUa in the subrack
0 is disabled.
16. Activate the license.
To activate the license, do as follows:
a. Log in to the Web LMT.
b. Run the LST LICENSE command. Check whether the license exists. If the license does
not exist, run the DLD LICENSE command to download the license file again.
c. Run the ACT LICENSE command. The license is activated.

4.2.4 Installing the Standby OMU


If you need to replace with the GOMU of two-node cluster mode, when you successfully
replace with the GOMU of single mode, switch to the two-node cluster mode according to the
instruction of the BSC6900 OMU Single and Dual Instance Handover Guide.

2019-9-8 Huawei Proprietary and Confidential 16


Copyright © Huawei Technologies Co.,
Ltd
Verification After the ReplacementVerification After the
BSC6900 GBAM-to-GOMU Replacement Guide Replacement

5 Verification After the Replacement

Check according to the following items (if any abnormal situation is detected, record the
details):
17. Check the version data.
 To check the version data after the replacement, do as follows:
 Log in to the GOMU by using the Web LMT (the administrator’s name and password are
consistent with that before the replacement).
 Run the CMP BRDVER command. Verify the version consistency between the BAM
and FAM.
 Run the ACT CRC command. Verify the consistency of the BAM and FAM data.
18. Check the running status of network elements (NEs)
 Check whether the LMT can be used normally.
 Check whether the alarms and traffic statistics can be viewed normally on the M2000
(the performance result file is correctly reported to the M2000).
 Check whether the configuration data is consistent with that before the replacement.
 Check whether the BSC board is in the normal status.
 Check whether the base transceiver station (BTS) board is in the normal status.
 Check whether an alarm exists.
19. Verify the service.
 The service dialing test is normal.
 Each key performance index (KPI) is normal.

2019-9-8 Huawei Proprietary and Confidential 17


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide GBAM RollbackGBAM Rollback

6 GBAM Rollback

6.1 Stopping the Running of the GOMU


To stop the running of the GOMU, do as follows:
20. Log in to the GOMU by using the Web LMT, and then run the RMV BRD command. The
GOMU configuration is deleted.
21. Run SET SCUPORT to enable port 10 and port 11 on the SCUa board in subrack 0 that is
connected to the GBAM.
22. Log in to the GOMU by using the PuTTY, and then run the following command:
/etc/rc.d/omud stop
23. Remove the GOMU.
When the OFFLINE indicator of the GOMU remains on, remove the GOMU.

6.2 Recovering the GBAM Connection


To recover the GBAM connection, do as follows:
24. Connect the external network and outside and inside network cable of the GBAM again.

25. Power on the GBAM.

6.3 Starting the GBAM


26. When the GBAM is powered on for about five minutes, log in to the GBAM server by using
the PuTTY, and then run the /etc/rc.d/omud start command.
27. Implement the rollback verification according to Chapter 5"5Verification After the
Replacement".

2019-9-8 Huawei Proprietary and Confidential 18


Copyright © Huawei Technologies Co.,
Ltd
BSC6900 GBAM-to-GOMU Replacement Guide 7 Appendix

7 Appendix

7.1 Common Commands of the psftp Software


Command Description Example

cd Used to switch the cd /mbsc/upgrade


OMU directory.
ls Used to view the child ls
directory structure of
the current directory.
lcd Used to visit the local lcd
folder of the stored D:\BSC6900V900R011C00SPC700\Software\setu
files. p\linux
get Used to transfer files For a file: get V900R011C00SPC700
from the OMU to the For a folder: get -r V900R011C00SPC700
local system.
put Used to transfer files For a file: put V900R011C00SPC700
from the local system For a folder: put -r V900R011C00SPC700
to the OMU.
mkdir Used to create a mkdir /mbsc/upgrade
directory on the OMU.
rmdir Used to delete a rmdir /mbsc/upgrade
directory on the OMU.