Copyright Notices and Disclaimers
Cat® VIMSpc and its related written manuals and documentation are © Caterpillar 2001-2018. All rights
reserved. No portion of these works may be reproduced, in whole or in part, for any purpose, without the
express written permission of Caterpillar. CAT, CATERPILLAR, their respective logos, and “Caterpillar Yel-
low”, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used
without permission.

Microsoft Access, Windows, Microsoft Internet Explorer, Microsoft Excel, are registered trademarks or trade-
marks of Microsoft Corporation in the United States and other countries. Other third party product names used
herein may be the trademarks of their respective owners.

Cat® VIMSpc and its related written manuals and documentation contains copyrighted content owned by third
parties which has been used under license from those third parties. Use of Cat® VIMSpc is subject to the
terms, conditions, limitations, and disclaimers that apply to all third party content contained herein.

Information in this document is subject to change without notice. Companies, names, and data used as
examples herein are fictitious unless otherwise noted.

2 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Contents
Copyright Notices and Disclaimers 2

Contents 3

Introduction 5

Introduction to this Manual 6

Scope 6

Overview of VIMSpc 6

Is this manual for you? 6

Products distributed and required 6

Overview of contents and focus 7

Contents 7

Focus 7

What's New in VIMSpc 8

Ordering VIMSpc 11

Pre-installation Checks and Tasks 13

Pre-installation introduction 14

Pre-installation Checks and Tasks 14

Minimum requirements for system 15

Step 1: Installing VIMSpc 17

Install VIMSpc from downloaded folder 18

Install VIMSpc through DVD 22

After VIMSpc Installation 27

Data Migration 28

Installing an update (patch) 31

11 January 2018 © Caterpillar 2001-2018 3 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Step 2: Connecting to a Machine 35

Connecting to a Machine 36

Serial Connection 37

Ethernet Connection 40

Troubleshooting in Connectivity 47

VIMSpc Failed to Connect to VIMS 3G Machine using version 2015A or later 58

VIMSpc Connected to VIMS 3G Machine, but Status Screen had Error 81

Troubleshooting in Installation 87

Installation hangs 87

Issue in DB2 Database Installation 88

Local 'Administrator' Group 88

Local Security Policy 91

Personal Folder 95

Issue in DB2 Database Connection 100

Issue in JRE Components 111

Issues while running VIMSpc update 114

Uninstalling VIMSpc 117

Uninstall VIMSpc 118

Complete Uninstallation of VIMSpc 121

Glossary 125

4 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
Introduction
VIMSpc
Installation Manual

Introduction to this Manual


Welcome to the VIMSpc Installation Manual. With the help of this manual, you are able to identify and suc-
cessfully install VIMSpc in your system.

It is important to follow the navigation in this manual for the correct order of installation.

Scope
This manual provides the necessary information and instructions for installing VIMSpc.

Overview of VIMSpc
VIMSpc is the off-board software which interacts with VIMS™ to retrieve the recorded data and create useful
reports and charts. These reports lead to intelligent analysis and better decision making for a more efficient
operation, lowering the cost per ton.

With VIMSpc, users can:

l Establish connection to VIMS ECM


l View machine status, real-time data, truck payload, and loader payload
l Activate and deactivate data logger
l Download VIMS data files
l Merge the downloaded data files to VIMSpc database
l View reports in graphical representation
l Export reports in PDF and Comma Separated Value (CSV) file formats
l Backup and restore data from database
l Set the configuration and settings

Is this manual for you?


The manual is written for personnel who have obtained proper subscription to install and configure VIMSpc.

Products distributed and required


In addition to VIMSpc, you need certain additional software for viewing and opening files, and for optimal func-
tionality of your VIMSpc.

6 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

The required additional products of VIMSpc are:

l Java 6 Update 25 (32 bit)


l IBM DB2 Database (Automatically installed in your system during VIMSpc installation)
l Internet Explorer
l Adobe® Reader®

Overview of contents and focus


The manual aims to assist you by identifying your operating system and software requirements, and by provid-
ing comprehensive and easy-to-follow install procedures.

Contents

The manual contains the following:

l Overview of VIMSpc
l Ordering VIMSpc
l Pre-installation checks and tasks
l Introduction to the products required
l Installation procedures
l Update VIMSpc
l Connectivity
l Troubleshooting
l Uninstallation procedures

The organization of the contents helps you in finding the information that you need. To ensure a successful
install, read this manual section by section, and complete all procedures that apply to you.

Focus

To get the most out of this manual and ensure a trouble-free installation:

1. Read the first four sections:


l Overview of VIMSpc
l Ordering VIMSpc
l Pre-installation checks and tasks
l Introduction to the products required
2. Make sure you complete all of the pre-installation checks and tasks.

11 January 2018 © Caterpillar 2001-2018 7 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

The order of installation is important, as is the order of the numbered steps in all of the procedures.

If you are having difficulties with a procedure, return to the information just before the procedure. Then, if
necessary, read all of the information again from the start of the section that contains the procedure. The
manual’s main focus is on the installation procedures and connectivity.

What's New in VIMSpc

Reports > Datalogger

In the Reports > Datalogger tab, various changes are made in this release and are explained below.

1. In the Selected Machines field, click Change to allow the user to select only one machine at a time. If
multiple machines are selected, the following error message is displayed:

2. In the Data Logger field, click Select to select data loggers from the list to generate reports. The selec-
ted time range of dataloggers should not exceed 4 hours for both Data and Graph as Report Type.

8 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

The following information is displayed, if the selected datalogger's time range exceeds 4 hours:

The following information is displayed, if no datalogger is available for the selected Machine or
TimeRange:

3. In the Report Type drop-down list, when Graph is selected , and if there are gaps between the Data-
logger Date and Time range, the below information is displayed. To generate report, both Dataloggers
and parameters have to be selected.

11 January 2018 © Caterpillar 2001-2018 9 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

The following warning message is displayed, if the parameters alone are selected to
Preview the report.

10 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Ordering VIMSpc
VIMSpc can be ordered through Midland online ordering system using the media numbers provided
below:https://oos.midlandcorp.com/CAT/Default.aspx

Media Description Media Number

Dealer Subscription JERD2138

Customer Subscription JERD2175

Replacement CD for Existing Dealer Subscription JERD2138 - Replacement CD

Replacement CD for Existing Customer Subscription JERD2175 - Replacement CD

11 January 2018 © Caterpillar 2001-2018 11 / 126


VIMSpc Installation Manual 5.4
Pre-installation
Checks and Tasks
VIMSpc
Installation Manual

Pre-installation introduction
This section explains what you are required to do before starting your installations. Pre-installation tasks pre-
pare your computer for installing all of the software distributed and required by VIMSpc, as explained in this
manual.

Pre-installation Checks and Tasks


The tasks you are required to do includes

l Verify the Administrator privileges in your system


l Check for minimum requirement of JRE components: Java 6 Update 25 (32 bit)

If the system does not meet the minimum requirement of JRE, the Merge and
Reports tabs of VIMSpc will not function properly.

l Check whether the latest version of Adobe® Reader® is installed


l Verify whether the PC is compatible with Pentium 1 GHz processor or greater
l Check for minimum requirement of 2GB RAM and 1 GB hard drive space
l Check for the minimum requirement of supported OS: Windows 7 and 8
l Verify for 40X speed CD-ROM drive or 8X speed DVD drive
l Check for 15.4 inch XGA Screen (1280x1024 compatible) to view VIMSpc
l Verify whether the system has a RS232 port with 16550AF UART or a USB 1.1 or 2.0 port with a USB
to serial port adapter for Serial connection. Also check the ethernet port for Ethernet connection.
l Check for VIMS ABL & 68K Download Cable P/N: 127-9797. If the laptop does not have a built-in serial
port, a USB to Serial adapter P/N: 370-8059 is needed
l Remove the air card from laptop if any

If the air card is not removed from the laptop, you will have connection problems.

l Stop VPN before beginning the VIMSpc installation


l If VIMSpc 2009B is already installed, it is not necessary to uninstall it

14 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

l If VIMSpc 2011A, or 2013A Beta Version is installed, it needs to be uninstalled first


l VIMSpc 2015A and above cannot be installed on XP and Vista systems
l Verify that user personal folder is NOT set to a server. If it is, change the following 2 registry keys to
point to %USERPROFILE%\Documents
o HKEY_CURRENT_USER\Software\Microsoft\Windows\CurrentVersion\Explorer\Shell Folder-
s\Personal
o HKEY_CURRENT_USER\Software\Microsoft\Windows\CurrentVersion\Explorer\User Shell
Folders\Personal

Additional requirements for installation of VIMSpc

l VIMSpc installation program will create a new local user 'db2admin' under Local 'Administrator' group.
Need to make sure that the user who is installing VIMSpc has permission to do this. (See also Local
'Administrator' group in Troubleshooting in Installation)
l Need to make sure that the local user 'db2admin' does not get removed and it remains in the Local
'Administrator' group after reboot.
l Make sure the Local 'Administrator' group, to which user 'db2admin' belongs, has the following per-
mission on PC as ' Access this computer from Network' (by running the command 'secpol.msc').
(See also Local 'Administrator' group in Troubleshooting in Installation)

Minimum requirements for system

VIMSpc
Standby Application System
Product

Compatible

Browser Any Web Browser (e.g., Internet Explorer, Google Chrome, etc.)

Operating Windows 7 and 8


System 64-bit and 32-bit

Database IBM DB2 Database v9.7.400.501

Components Java 6 Update 25 onwards (32-bit)

11 January 2018 © Caterpillar 2001-2018 15 / 126


VIMSpc Installation Manual 5.4
Step 1:
Installing VIMSpc
VIMSpc
Installation Manual

Install VIMSpc from downloaded folder


Follow the process below to install VIMSpc from your system.

NOTE: The account used to install VIMSpc on a computer needs Administration privileges.

To install VIMSpc

1. Locate the downloaded VIMSpc.exe file in your system.


2. Right-click on the VIMSpc.exe and select Run as administrator.

18 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

NOTE: The User Access Control pop-up displays based on the settings selected in Control
Panel.

3. The User Access Control pop-up displays.


4. Click Yes. The installation begins

The Welcome to the InstallShield Wizard screen displays.

NOTE: Clicking Cancel stops the installation process.

5. Click Next.

The License Agreement screen displays.

11 January 2018 © Caterpillar 2001-2018 19 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

6. Read the License Agreement.


7. Select I accept the terms in the license agreement, if you want to proceed with installation.
8. Click Next. The Installing VIMSpc screen displays.

20 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

9. The IBM DB2 Database is being installed. The InstallShield Wizard Completed screen displays.

10. Click Finish.

NOTE: Click Launch VIMSpc 2015A check box to install product icon in your system desktop.

11. You have now completed the VIMSpc installation.

11 January 2018 © Caterpillar 2001-2018 21 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Install VIMSpc through DVD


This section describes how to install VIMSpc to your system through DVD.

To install VIMSpc through DVD

1. Insert DVD in your PC.


2. In Start, click Computer to verify the DVD is detected.
3. Right-click on the setup file available in the detected DVD and select Open.

22 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

NOTE: The User Access Control pop-up displays based on the settings selected in Control
Panel.

4. The User Access Control pop-up appears.


5. Click Yes. The following screen appears.

11 January 2018 © Caterpillar 2001-2018 23 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

6. Click INSTALL VIMSpc. The following Open File - Security Warning pop-up appears.

7. Click Run.

The Welcome to the InstallShield Wizard screen displays.

24 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

NOTE: Clicking Cancel stops the installation process.

8. Click Next.

The License Agreement screen displays.

9. Read the License Agreement.


10. Select I accept the terms in the license agreement, if you want to proceed with installation.

11 January 2018 © Caterpillar 2001-2018 25 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

11. Click Next. The Ready to Install the Program screen appears.

12. Click Install.


The Installing VIMSpc 2015A screen appears.

26 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

13. The IBM DB2 Database is being installed.The InstallShield Wizard Completed screen displays.

14. Click Finish.

NOTE: Click Launch VIMSpc 2015A check box to install product icon in your system desktop.

15. You have now completed the VIMSpc installation.

After VIMSpc Installation


After VIMSpc installation, the following folders are created in your system. You can check the folders in
respective paths.

Application Folder:

This folder contains the executable and library files for VIMSpc.

l On 64-bit Windows 7 and 8 the folder path: C:\Program Files(x86)\Caterpillar\VIMS3G


l On 32-bit Windows 7 and 8 the folder path: C:\Program Files\Caterpillar\VIMS3G

11 January 2018 © Caterpillar 2001-2018 27 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

User Data Folder:

This folder contains user data such as database, settings, unmerged, backup, and log files. This folder is
shared among all the users of the PC.

l On 32-bit & 64-bit Windows 7 and 8 the folder path: C:\Users\Public\Caterpillar\VIMS3G

Application Data Folder:

This folder contains VIMSpc master database files. This folder is shared among all the users of the PC.

l On 32-bit & 64-bit Windows 7 and 8 the folder path: C:\ProgramData\Caterpillar\VIMS3G

VIMSpc 2015A and above is not supported on XP and Vista.

Data Migration
Legacy Data Migration Utility

The Legacy Data Migration Utility allows users to move the data from older versions of VIMSpc into the cur-
rent database. The legacy database versions supported by this utility are VIMSpc 2007A, 2008A, 2009B, and
2011A.

The utility copies data from the legacy database file (user selected) into the current database. The utility will
not change the legacy database file, nor change any existing data in the current database.

To access the utility

28 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

1. Go to Start > All Programs, under Caterpillar VIMS, click Legacy Database Migration.

2. The VIMS Database Migration Utility pop-up window displays. Click Browse to select the legacy data-
base file from your local computer and click Migrate.

11 January 2018 © Caterpillar 2001-2018 29 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

3. The following confirmation message displays.

4. Click Yes.
5. The migration takes a few minutes to complete depending on the amount of data required to transfer.
6. Once the migration is completed, a dialog appears.

7. Click OK.
8. Click Close to exit the migration utility.

30 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Installing an update (patch)


Upgrade your VIMSpc by installing the latest update. Download the update of VIMSpc from dealer.cat.com.

To download update

1. Refer to dealer.Cat.Com https://dealer.cat.com/en/products/technology/mining-technology-


autonomy/health/vims-product-support-information.html.
2. Navigate to SOFTWARE & CURRENT RELEASES. The software and current releases displays.
The available version of software varies for each release.

3. Click VIMSpc2015A 5.3.0.1 Update 15.2.9 link. The update gets downloaded automatically.

To install update

1. Locate the downloaded VIMSpc update .exe file from your local system.

2. Double-click on the .exe . The following cmd window displays.

11 January 2018 © Caterpillar 2001-2018 31 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

3. The VIMSpc is updated successfully. Press any key to continue.

The following message is displayed while trying to run the update when VIMSpc is running. Exit from
VIMSpc and try installing the update.

32 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

The following message is displayed while trying to run the update when MS access is running. Exit
from MS Access and try installing the update.

Installing the update also includes the Master Database update.

11 January 2018 © Caterpillar 2001-2018 33 / 126


VIMSpc Installation Manual 5.4
Step 2:
Connecting to a Machine
VIMSpc
Installation Manual

Connecting to a Machine
VIMSpc communicates with machines equipped with compatible hardware.

Following are the two types of connection methods in VIMSpc:

l Serial Connection
l Ethernet Connection

Different hardware utilizes different connection cables and connection methods, as shown in the table below.

Connection Cable
Compatible ECM ECM Part Number Connection Method
Part Number

A5N2 459-0786 305-5528 Ethernet

A4N4 285-1142 305-5528 Ethernet

523 (A4:G4) 351-8492 305-5528 Ethernet

VIMS ABL2M 327-3520 127-9797 Serial

VIMS 68K 130-5131 127-9797 Serial

TPM ABL1M 169-0489 127-9797 Serial

TPM Legacy 3E-7841 9X-3075 Serial

PCS A4M3 252-2422 127-9797 Serial

PCS Legacy 148-6376 9X-3075 Serial

36 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Serial Connection
Serial connection utilizes the serial port on laptop, or USB port through a USB-to-Serial adapter to com-
municate with the machine. VIMSpc must be configured to use the correct communication port for con-
nectivity. By default, the port is set to COM1 for connectivity. You are allowed to change the port, if
necessary.

To check the port and connect through serial connection

1. Open VIMSpc. The VIMSpc screen displays.

11 January 2018 © Caterpillar 2001-2018 37 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

2. Click Settings. The Settings screen displays. Under General > Communication, check the available
ports.

3. The default port selected is COM1, If the ECM is connected to a different port, select the appropriate
COM port or continue to connect.
4. Select the Preferred Connection as Serial.
5. Click Connect.

38 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

If the port selected is not connected to any ECM or connection is not established, the
following error message is displayed.

6. If the connection is successful, the Status screen displays.

11 January 2018 © Caterpillar 2001-2018 39 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Ethernet Connection
Virtual Network Switch (VNS)

The latest generation of VIMS hardware requires Ethernet-based connection. VIMSpc utilizes Virtual Network
Switch (VNS) mechanism to communicate with the machine. VNS is a software application that acts as a
switch in transferring the packets of information from one network to another using a single Network Interface
Card (NIC). VIMSpc will modify the network settings of VNS rather than the actual physical network card.

However, the laptop can be used in the field as well as in the office without changing the Settings of physical
network card.

VNS is shown as 'Caterpillar Machine Network Connection' on the PC. When VIMSpc is un-installed, VNS is
removed along with the driver files needed by the virtual adapter.

NOTE: The connected ECM and IP Address of the PC should be in the same network.

When VIMSpc connects to a machine for the first time, it prompts the user to select a physical adapter.

Do not choose the wireless adapter card.

To select physical adapter

1. Plug VIMS cable (Ethernet cable) into the PC's Ethernet port.

NOTE: Only by doing the above step, the status of LAN adapter will be shown as "connected"
in the Select Ethernet Adapter pop-up window.

2. Click Settings. The Settings screen displays.

40 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

3. On the General tab, click Select Ethernet Adapter.

4. The Select Ethernet Adapter pop-up window is displayed.

11 January 2018 © Caterpillar 2001-2018 41 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

5. Select the Ethernet adapter for connecting to VIMS ECM. Make sure the selected adapter is not a wire-
less adapter and other adapters are either in disconnected or in disabled state.
6. Click OK.

To make Ethernet connection

1. Plug VIMS cable (Ethernet cable) into the PC's Ethernet port.
2. Open VIMSpc. The VIMSpc screen displays.

42 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

3. Click Settings. The Settings screen displays.

4. Select the Preferred Connection as Ethernet.


5. Select the Auto Detect ECM as On.

11 January 2018 © Caterpillar 2001-2018 43 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

6. Click Connect . If the ECM uses the default IP address, the Status screen displays. If not the User IP
Details pop-up appears.

7. If the Auto Detect ECM is selected as Off, the User IP Details pop-up window displays.

44 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

NOTE: The following message is displayed, when you click OK without providing the User IP
Details.

8. Enter ECM IP Address in the provided fields.

9. As you enter the ECM IP Address, the PC IP Address and PC Mask fields auto populates.
10. Make necessary changes as required in the populated PC IP Address and PC Mask fields, if needed.

11 January 2018 © Caterpillar 2001-2018 45 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

NOTE: ECM and IP Address of the PC should be in the same network

11. Click OK.

NOTE: Click Cancel to stop the connection process.

If connection is not established, the following error message is displayed.

46 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

12. If the connection is established, The Status screen displays.

NOTE: The Status screen differs for each connected ECM. Also view the connection status by
entering the respective connected ECM IP Address in the web browser's URL.

Troubleshooting in Connectivity
The following are the machines which can be connected to VIMSpc:

Articulated Truck

725C (S/N: LFB1-UP; TFB1-UP)

730C (S/N: LFF1-UP; TFF1-UP)

730C EJECTOR (S/N: LFH1-UP; TFH1-UP)

735B (S/N: L4D1-UP; T4P1-UP)

735C (S/N: LFJ1-UP; TFJ1-UP)

11 January 2018 © Caterpillar 2001-2018 47 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

740B (S/N: L4E1-UP; T4R1-UP)

740B EJECTOR (S/N: L4F1-UP; T4S1-UP)

740C EJECTOR (S/N: LFN1-UP; TFN1-UP)

745C (S/N: LFK1-UP; TFK1-UP)

Excavator

5130 (S/N: 7TJ1-UP; 5ZL1-UP)

5130B (S/N: 4CS1-UP)

5230 (S/N: 7LL1-UP)

5230B (S/N: 4HZ1-UP)

Landfill Compactor

826K (S/N: 2321-UP; SET1-UP)

836K (S/N: LWZ1-UP; TWZ1-UP)

Load Haul Dump

R1600G (S/N: 9PP1-UP; 9YZ1-UP)

R1600H (S/N: 9SD1-UP)

R1700G (S/N: SBR1-UP; 8XZ351-UP)

R2900G (S/N: GLK1-UP; JLK1-UP)

R3000H (S/N: RCM1-UP)

Motor Grader

14H (S/N: ASE1-UP)

14M (S/N: B9J1-UP; R9J1-UP)

16H (S/N: ATS1-UP)

16M (S/N: B9H1-UP; R9H1-UP)

16M Series 3 (S/N: E9Y1-UP; N9Y1-UP)

24H (S/N: 7KK1-UP)

24M (S/N: B931-UP; B9K1-UP)

48 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Off-Highway Truck/Tractor

770G (S/N: RMA1-UP; TWA1-UP; RMD1-UP; KDH1-UP; ECM1-UP; ECX1-UP)

772G (S/N: TWB1-UP; RME1-UP; RMH1-UP; LTS1-UP; KEX1-UP; LTX1-UP)

773D (S/N: NBJ1-UP)

773E (S/N: PRB1-UP; ASK1-UP; KEG1-UP; DJS1-UP)

773F (S/N: EED1-UP; EXD1-UP)

776D (S/N: AFS1-UP) 777D (S/N: AGC1-UP; FKR1-UP)

777E (S/N: KDP1-UP)

777F (S/N: JRP1-UP; JXP1-UP)

777G (S/N: GT71-UP; T5A1-UP; TNM1-UP; RDR1-UP; T4Y1-UP)

784B (S/N: 5RK1-UP)

784C (S/N: 2PZ1-UP)

785B (S/N: 6HK1-UP)

785C (S/N: 1HW1-UP; APX1-UP; 5AZ1-UP)

785D (S/N: DMC1-UP; MSY1-UP)

789B (S/N: 7EK1-UP)

789C (S/N: 2BW1-UP)

789D (S/N: SPD1-UP; SHH1-UP)

793B (S/N: 1HL1-UP)

793C (S/N: CBR1-UP; 4AR1-UP; ATY1-UP; 4GZ1-UP)

793D (S/N: FDB1-UP)

793F (S/N: SND1-UP; SSP1-UP; SXP1-UP; RBT1-UP)

793F AC (S/N: EMD1-UP)

794 AC (S/N: MN51-UP)

795F AC (S/N: ERM1-UP)

795FAC XQ (S/N: SNT1-UP)

11 January 2018 © Caterpillar 2001-2018 49 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

797 (S/N: 5YW1-UP)

797B (S/N: JSM1-UP)

797F (S/N: LAJ1-UP; WSP1-UP)

MT4400D AC (S/N: MH41-UP)

Quarry Truck

773G (S/N: MWH1-UP; JWS1-UP; T5S1-UP; T5T1-UP)

775F (S/N: EYG1-UP; DLS1-UP)

775G (S/N: T5F1-UP; RFM1-UP; MJS1-UP; T5W1-UP)

Soil Compactor

825K (S/N: 2331-UP; SEE1-UP)

Track-Type Tractor

D10R (S/N: AKT1-UP)

D10T (S/N: RJG1-UP)

D11R (S/N: AAF1-UP; 7PZ1-UP)

D11T (S/N: AMA1-UP; GEB1-UP; TPB1-UP; MDG1-UP; JEL1-UP; JNS1-UP)

D8T (S/N: J8B1-UP; MLN1-UP; FCT1-UP; KPZ1-UP)

D9T (S/N: TWG1-UP; RJS1-UP; REX1-UP)

Underground Articulated Truck

AD30 (S/N: CXR1-UP; DXR1-UP)

AD45B (S/N: CXM1-UP)

AD55 (S/N: DNW1-UP)

AD55B (S/N: JNW1-UP)

AD60 (S/N: KNW1-UP)

Wheel Dozer

824K (S/N: 2341-UP; RWB1-UP)

834K (S/N: LWY1-UP; TWY1-UP)

50 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

844K (S/N: MBE1-UP; KLS1-UP)

854G (S/N: AMP1-UP; A4W1-UP; 1JW1-UP)

854K (S/N: 2211-UP; H9K1-UP; H8M1-UP)

Wheel Loader

950K (S/N: R4A1-UP; J5M1-UP; FER1-UP)

950M (S/N: EMB1-UP; ENE1-UP; XCJ1-UP; FTR1-UP; LCR1-UP; J1S1-UP)

962K (S/N: T6A1-UP; FLL1-UP; X4T1-UP)

962M (S/N: EJB1-UP; JYD1-UP; LSE1-UP; RCL1-UP; J2S1-UP; F2T1-UP)

966K (S/N: PBG1-UP; TFS1-UP)

966K Series XE (S/N: NGX1-UP)

966M (S/N: DYC1-UP; R8D1-UP; KJP1-UP)

966M Series XE (S/N: P6C1-UP; B8P1-UP)

972K (S/N: PEM1-UP; Z4W1-UP)

972M (S/N: L8E1-UP; A8P1-UP; JPR1-UP)

972M Series XE (S/N: M5S1-UP; EDW1-UP)

980G Series II (S/N: AXG1-UP)

980H (S/N: MHG1-UP)

980K (S/N: W7K1-UP; GTZ1-UP)

980M (S/N: MK21-UP; MGD1-UP; KRS1-UP; N8T1-UP)

982M (S/N: MK61-UP; F9A1-UP; LRS1-UP; K1Y1-UP)

988K (S/N: LWX1-UP; TWX1-UP)

990K (S/N: DJK1-UP; A9P1-UP)

992G (S/N: 7HR1-UP; AZX1-UP; ADZ1-UP)

992K (S/N: 8801-UP; H4C1-UP; ZMX1-UP)

993K (S/N: LWA1-UP; Z4D1-UP; Z9K1-UP; Z4Z1-UP)

994 (S/N: 9YF1-UP)

11 January 2018 © Caterpillar 2001-2018 51 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

994D (S/N: 3TZ1-UP)

994F (S/N: 4421-UP)

994H (S/N: DWC1-UP) , 994K (S/N: MRK1-UP)

Introduction
This troubleshooting instruction is intended to diagnose and troubleshoot VIMSpc common connectivity
issues. It can be in Electronic Control Modules ECMs of VIMS 3G - 2851142 , PRODUCT LINK 523 -
3518492, PL Elite - 459-0786 on Ethernet port, and VIMS ABL2M - 327-3520, VIMS 68K - 130-5131, TPM
ABL1M - 169-0489, TPM Legacy - 3E-7841, PCS A4M3 - 252-2422, PCS Legacy - 148-6376 on Ethernet port.

VIMSpc incorporates the previous VIMSpc connect software that connects to machines with VIMS 3G,
through a network cable attached to the user laptop and VIMS 3G service port. VIMSpc handles the IP
addresses involved when connecting.

If the connection gets hung up, kill VIMSpc.exe, open Windows Task Manager (using ctrl+alt+del) and look in
processes for VIMSpcNet.exe. If running, terminate the process. Then start VIMSpc again and try to recon-
nect.

If VIMSpc is not connected, try connecting to another Ethernet by opening "Network Connections", from Con-
trol Panel. If the Local Area Connection shows "Unplugged" but is not unplugged, disable and then enable the
device. It should be connected.

Important Safety Information


Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to
observe basic safety rules or precautions. An accident can be avoided by recognizing potentially hazardous
situations before an accident occurs.

The user must be alert to potential hazards. He should also have the necessary training, skills, and tools to
perform these functions properly.

Safety precautions and warnings are provided in this instruction and on the product. If these hazard warnings
are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate
every possible circumstance that might involve a potential hazard. Therefore, the warnings in this publication
and the warnings that are on the product are not all inclusive.

52 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

If a tool, procedure, work method, or operating technique that is not recommended by Caterpillar is used,
ensure that it is safe to use. Also check that the product will not be damaged or made unsafe by the operation,
lubrication, maintenance, or repair procedures that are used.

Required Tools

Required Tools

Product Part Number Description

VIMSpc 2015A or later

CAT® ET 2017A or later

Administrative Rights

127-9797 Cable As. VIMS download cable for VIMS ABL and 68K hardware

370-8059 Adapter Kit Serial Adapter Kit

425-6889 Cable As. VIMS 3G Download Cable

457-6114 Cable As. 14-pin service port connector with Ethernet

466-6258 Communication Adapter

VIMSpc Diagnostic Script VIMSpc 2015A

Two Most Common Connectivity Recovery Steps


The most common connectivity issues can be fixed by the following two steps. If the connectivity issues are
beyond the following two steps, the rest of this Troubleshooting in Connectivity section will guide you through
more troubleshooting techniques and provide direction on where to gather information and send to the Dealer
Solutions Network (DSN).

11 January 2018 © Caterpillar 2001-2018 53 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

NOTE: For more assistance with this software, contact your Caterpillar Dealer and the Dealer will con-
tact the DSN team.

DSN Contact Information

Login to DSN website https://dsn.cat.com/ for the DSN contact information.

Step 1

Refer to VIMSpcSelfCheck.log in the "Step 6: Gather Log Files and Status Report" of "VIMSpc Failed to Con-
nect to VIMS 3G Machine using version 2015A or later" section to ensure that the Caterpillar Machine Net-
work Connection has been installed and correctly referenced to the appropriate Local Area Connection port.

Step 2

Identify the Correct Network Adapter and set obtaining the IP address automatically

Plugging into a live Ethernet network will toggle the status of the local area connection network adapter. Once
this is plugged in, monitor the status of the Network Connections of PC and verify which one will change. This
can be performed on a powered ON machine with VIMS ethernet cable or USB to ethernet adapter.

1. Go to Start > Control Panel > Network and Internet > View network status and tasks > Change
adapter settings.

54 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

2. The list of available network connection appears. Connect the live Ethernet cable into the PC.

NOTE: If the preferred Caterpillar Machine Network or Local Area Connection is disabled, right-
click and select Enable on the disabled network adapter.

3. Change the general settings of both Caterpillar Machine Network Connection and Local Area Con-
nection to "Obtain IP Address Automatically".

11 January 2018 © Caterpillar 2001-2018 55 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

4. Right-click on the network adapters and select Properties.

5. The Local Area Connection Properties pop-up appears. Select the Internet Protocol Version 4
(TCP/IPv4) and click Properties.

56 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

6. The Internet Protocol Version 4 (TCP/IPv4) Properties pop-up appears. Select Obtain an IP address
automatically.

7. Click OK and try to connect to VIMSpc.

11 January 2018 © Caterpillar 2001-2018 57 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

VIMSpc Failed to Connect to VIMS 3G Machine using version 2015A or


later

58 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Step 1: Verify the Air Card (Cellular Card) is removed and Virtual Private Network (VPN) is not con-
nected.

Air Card

If the air card is installed, the Caterpillar Network Adapter will try to access the Air Card's Network con-
nection. When the Caterpillar Network Adapter is connected to the Air Card's Network, the physical Local
Area Network Port will not be utilized, which is required. So the Cat® Network Adapter will try to utilize the air
card's physical port.

NOTE: Ensure that the air card is removed and the network adapter status is shown as disabled.

1. Go to Start > Control Panel > Network and Internet > View network status and tasks > Change
adapter settings.

11 January 2018 © Caterpillar 2001-2018 59 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

2. The following screen appears. Right-click on the air card network adapter and select Disable.

VPN

If VPN is active, the communications intended to go to the VIMS ECM may get routed through the VPN
portal. You are advised to disconnect the VPN.

60 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

To identify whether the VPN is running

1. Look at the windows task bar or launch the VPN program.

2. The following pop-up appears if the VPN is connected.

3. Click Disconnect to disconnect the VPN.

Step 2: Use the VIMS 3G Ethernet Cable

Install and use the Cable As. 3055528 between the VIMS 3G Service Port (Cab or Bumper) and the PC
equipped with VIMSpc. Ensure that the cable is installed properly and secure. Also observe the LAN port
status lights. If the machine power is ON and status light is blinking, then the cable is installed correctly.

11 January 2018 © Caterpillar 2001-2018 61 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

If the status light is not blinking, troubleshoot the connected wire.

Step 3: Check the Status of Ethernet LAN Status Lamps

1. Try unplugging and plugging in the RJ45 connector back of PC to check whether there is a loose or
intermittent connection.
a. Try the same with service port connector.
2. If the status lamps are not blinking, ensure that the cable is in good shape and not broken or in dis-
repair.

a. Observe the condition of pins in the cable and the service port connector.
b. Ohm out wiring between the service port connector and the VIMS ECM.
c. Ohm out the connection between download cable RJ45 connector and service port connector.

62 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

3. Try to connect another service cable or plug in to another machine, or plug into an official local area net-
work to verify the function of status lamps.

Step 4: Run VIMSpc Diagnostic Script

The VIMSpc Diagnostic Script VIMSpc 2012A or VIMSpc 2015A master database 15.2.0 update or later can
be found at:

l For 32bit systems, located in c:\Program Files\Caterpillar\VIMS3G


l For 64bit systems, located in c:\Program Files (x86)\Caterpillar\VIMS3G

Ensure that the local area connection and Caterpillar Machine Network Connection must be enabled.
Refer"Troubleshooting in Connectivity" on page 47 for the steps to enable the Local Area Network Adapter
under Step 2 section.

NOTE: Verify which network adapter is associated with the physical LAN port in PC.

1. Go to c:\Program Files (x86)\Caterpillar\VIMS3G and double-click the VIMSpcSelfDiagnose.vbs


script.

11 January 2018 © Caterpillar 2001-2018 63 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

2. The following pop-up appears.

3. Click OK. The following pop-up appears.

4. Click OK. The following pop-up appears.

5. Click OK. The following pop-up appears.

6. Click OK.

64 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Step 5: Has VIMS Module IP address been changed from Default?

The above screenshot shows that the VIMS Main ECM runs with the earlier versions of VIMS software.

The “Software Group Description” for earlier versions of VIMS software doesn’t have “Underscore” in the
string (e.g., VIMS3G 7.2 Production 1 ). If yes it would need a custom IP address (i.e., Manual PC Network
configuration change in order to configure the PC and VIMS Main ECM to be in a same subnet mask range).

The above screenshot shows that the VIMS Main ECM runs with the newer versions of VIMS software.

The “Software Group Description” for newer versions of VIMS software would have “Underscore” in the string
(e.g., PLGSM_Q3_PROD_2.0). For newer versions of VIMS software, Custom IP address (i.e., Manual PC
Network configuration is not needed).

If Manual PC Network Configuration is necessary, perform the following steps:

1. Go to Start > Control Panel > Network and Internet > View network status and tasks > Change
adapter settings.

11 January 2018 © Caterpillar 2001-2018 65 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

2. The list of available network connection appears.

3. Right-click on the Local Area Connection and select Properties.

66 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

4. The Local Area Connection Properties pop-up appears. Select the Internet Protocol Version 4
(TCP/IPv4) and click Properties.

5. The Internet Protocol Version 4 (TCP/IPv4) Properties pop-up appears. Select Use the following
IP address and provide the IP details, and click OK.

11 January 2018 © Caterpillar 2001-2018 67 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

6. Reference the VIMS 3G IP configuration by connecting to CAT ET®. Ensure that the IP address
should not match any other IP address on the network. The subnet mask and default gateway should
match the other addresses on the network. (See also "Check VIMS IP address from CAT ET®" in Step
5a)

68 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

NOTE: Use standard IP convention.

7. Click OK to exit and save computer network setting.


8. Click OK to exit the local area connection properties.
9. To verify settings IP settings, goto Start and type cmd. The cmd is auto-populated, double-click on the
cmd.

11 January 2018 © Caterpillar 2001-2018 69 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

10. The cmd appears. Type ipconfig and press Enter. The configured IP address is displayed.

11. Browse the cmd window for Ethernet Adapter Local Area Connection.
12. Close the cmd window after verification.

NOTE: For further details, refer to REHS7441: VIMS 3G Third Party Radio connection Guide. Attempt
to reconnect VIMSpc after the changes.

Step 5a: Check VIMS IP Address Settings

1. Go to Start > All Programs > CAT ET > 2017A > 2017A Electronic Technician.

70 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

2. In the Configuration screen, under VIMS Main Module, select Internet Protocol. The IP address
details appears.

11 January 2018 © Caterpillar 2001-2018 71 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

3. In the Configuration screen, under VIMS Application Module, select Internet Protocol. The IP
address details appears.

4. Verify that the IP Settings are one of the two default settings provided in the below table.
5. If the IP settings are different, it should be set back to default depending on the site requirements or
manual connect.

72 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Legacy VIMS 3G Software Flash files and Earlier Versions Default Ethernet IP addresses

Application
Main Flash Ethernet Address Ethernet Address
Flash

IP 192.168.1.21 IP 192.30.52.45
423-7965 Mon-
380-2995 Mon-
Mask 255.255.255.0 itor Software Mask 255.255.255.0
itor Software
GP.
GP. Gateway 192.168.1.1 Gateway 192.30.52.1

Current VIMS 3G Software Flash files and Later Versions Default Ethernet IP addresses

Main Flash Ethernet Address Application Flash Ethernet Address

IP 165.26.79.218 IP 165.26.79.226
392-0741 Mon- 392-0742 Monitor
Mask 255.255.255.252 Mask 255.255.255.252
itor Software Software GP.
GP. Gateway 165.26.79.216 Gateway 165.26.79.224

Step 6: Gather Log Files and Status Report

Follow the information below to gather "log files (VIMSpcSelfCheck.log)" and status report and send to DSN
for investigation VIMSpcSelfCheck.log.

11 January 2018 © Caterpillar 2001-2018 73 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

1. When connected to machine, double-click VIMSpcSelfCheck file in VIMSpc application.


a. For 32bit systems, located in "c:\Program Files\Caterpillar\VIMS3G".
b. For 64bit systems, located in "c:\Program Files (x86)\Caterpillar\VIMS3G".

74 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

2. Following cmd appears. Press any key to exit.

3. Type %temp% in the address bar to open the temp directory. Find VIMSpcSelfCheck file in temp dir-
ectory.

11 January 2018 © Caterpillar 2001-2018 75 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Perform the following steps to self diagnose potential Physical network adapter problems:

1. Open VIMSpcSelfCheck.log in notepad.


2. Check beginning of file for errors.

NOTE: If there are errors in the System Information Check, WMIC NIC, and WMIC Service,
then the Windows Management Instrumentation (WMI) files on your PC are corrupted.

3. Find the FixWMI.cmd file in Windows explorer, right-click and select Run as administrator (Win-
dows 7).

76 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

a. For 32bit systems, located in c:\Program Files\Caterpillar\VIMS3G.


b. For 64bit systems, located in c:\Program Files (x86)\Caterpillar\VIMS3G.

4. After script completes, run VIMSpcSelfCheck again to open log file and verify that WMI has been
fixed.
5. Scroll down to near the bottom of the document or perform a search for Function Set Physical
Adapter.
6. Verify that the physical adapter and virtual adapter MAC addresses are off by a factor of 2 in the first
byte, which is the indication that the installation of VIMSpc and selection of the right network adapter.

If the physical adapter and virtual adapter MAC addresses first byte difference is not of 2, then either a rein-
stallation of VIMSpc will need to be performed or select the correct physical network adapter and run the
VIMSpcSelfDiagnose.vbs script again.

11 January 2018 © Caterpillar 2001-2018 77 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Cat® ET Status Report

1. Go to Start > All Programs > CAT ET > 2017A > 2017A Electronic Technician.

2. In the Configuration screen, under Information tab, select Product Status Report.

78 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

3. The following screen appears. Fill in the mandatory details and click Create Report.

11 January 2018 © Caterpillar 2001-2018 79 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

4. The report is generated. Click Save As to save the report to your local computer.

5. The following message appears.

80 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

VIMSpc Connected to VIMS 3G Machine, but Status Screen had Error

Step 1: Problem with Software Enabled Attachment (SEA) or Configuration Not Installed

11 January 2018 © Caterpillar 2001-2018 81 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

If the VIMS software enabled attachment is "Not Installed", or if there is no configuration installed on the
VIMS Main module, then the error message is displayed on the status screen after connection.

Connect to the Main VIMS ECM with Cat® ET. In the configuration page, verify the value of Data Acquis-
ition System Installation Status. If the Data Acquisition System Installation Status is set to Not Installed,
then change the value to Installed.

Refer to Special Instruction, REHS1238, "Obtaining Factory Passwords and Software Enabled Attachments"
for more information.

Step 2: Problem with Proxy Setting

82 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

NOTE: The error message shown above could be the result of Proxy Setting incompatible with the
VIMS onboard module.

1. Go to Start > Control Panel > Network and Internet > View network status and tasks > Internet
Options.

11 January 2018 © Caterpillar 2001-2018 83 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

2. The Internet Properties pop-up appears. Click Connections tab and click LAN Settings.

3. The Local Area Network (LAN) Settings pop-up appears.


a. If Proxy Server box is unchecked, then the settings should be compatible with the VIMS onboard
module.

84 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

b. If Proxy Server box is checked, and port 80 is selected with an address associated to it, then click
Advanced.

11 January 2018 © Caterpillar 2001-2018 85 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

4. The Proxy Settings pop-up appears.

NOTE: Copy and paste the following into the Exceptions box:
"165.26.7*.*;192.168.1.21;192.30.52.45; 10.0.0.7;10.0.0.8". Add a ";" between each
addresses. An "*" is a wild card, and adding in place of IP address octets will allow any number
to be populated in that octet.

If the VIMS IP address has changed, then add an additional IP address exception. Contact
your network administrator for further queries.

5. Click OK in the proxy settings pop-up.


6. Click OK in the Local Area Network (LAN) Settings pop-up.

86 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Troubleshooting in Installation
Installation hangs
Cause #1

Several factors can cause this condition. Other processes or programs may be using lots of system
resources, leaving insufficient resources for the installation to complete as normal.

Solution #1

Open the Windows Task Manager and examine the figures shown on the Performance tab. If the CPU is run-
ning at 100%, the system is probably just very busy and you should leave the installation to complete in its
own time. It is unusual for the system to be at 100% CPU for very long unless something very resource–
intensive is running. If something else is using a lot of resources, consider running the installation at a later
time. If no processes are known to be running and nothing obvious shows up when checking, it may be
prudent to run a virus scan to determine if a virus has made its way into the system.

Cause #2

Insufficient disk space.

Solution #2

Check that you have sufficient disk space to complete the installation. If there is not enough disk space avail-
able to install the VIMSpc, a message will display telling you how much disk space you need to free up. Once
enough disk space has been made available, begin the installation again.

Cause #3

System has hung.

Solution #3

The system may be hung or become unstable. Check for other programs that are still running and responding,
and check the Applications tab of the Task Manager to see whether any programs have a status of Not
Responding. If any applications are not responding, close them and see if the installation process continues.
If not, you may have to exit the installer and try again after the system resumes.

11 January 2018 © Caterpillar 2001-2018 87 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Cause #4

Installation crashes for no apparent reason and VIMSpc doesn't work as expected.

Solution #4

Uninstall and try reinstalling VIMSpc.

Issue in DB2 Database Installation


Cause #1

Problem in DB2 Installation

Solution #1

Check the below given system properties such as Local Administrator Group, Local Security Policy, and Per-
sonal Folder. Then uninstall VIMSpc and DB2 Database and try reinstalling VIMSpc.

Local 'Administrator' Group

User installing VIMSpc should be in the local administrators group, not as domain administrator.

To check local administrator group

1. Go to Start > Control Panel > User Accounts.

88 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

2. The Control Panel Home screen displays.

11 January 2018 © Caterpillar 2001-2018 89 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

3. Click User Accounts to open the following screen.

4. Click Manage User Accounts. The User Access Control pop-up window displays. Click Yes.

90 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

5. The User Accounts window displays.

NOTE: A few examples of domain administrator groups given in the above screen are AP and
NA.

Local Security Policy

User or user's group should be in the "Access this computer from the network" under local security policy.

11 January 2018 © Caterpillar 2001-2018 91 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

To check local security policy

1. Click Start and type 'secpol.msc' in the search box. The search results are displayed.

2. Click . The User Access Control pop-up window displays.

92 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

3. Click Yes. The Local Security Policy screen displays.

11 January 2018 © Caterpillar 2001-2018 93 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

4. Under Security Settings, click Local Policies > User Rights Assignment, and double-click on the
Access this computer from the network.

94 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

5. The Access this computer from the network Properties screen displays.

NOTE: The user and user's group found are Administrators and Authenticated Users.

Personal Folder

User's personal folder in registry editor should be on local hard drive, not in network drive. The personal folder
should be set to %USERPROFILE%\Documents.

11 January 2018 © Caterpillar 2001-2018 95 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Personal folder should be checked in the following path:

l HKEY_CURRENT_USER\Soft-
ware\Microsoft\Windows\CurrentVersion\Explorer\Shell Folders\Personal
l HKEY_CURRENT_USER\Software\Microsoft\Windows\CurrentVersion\Explorer\User
Shell Folders\Personal

NOTE: By default, the personal folder is set to %USERPROFILE%\Documents. If not, copy the cur-
rent values of personal folder and change it to %USERPROFILE%\Documents. You can restore per-
sonal folder values after the DB2 installation, if required.

To open registry editor

1. Click Start and type 'regedit' in the search box. The search results are displayed.

96 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

2. Click . The User Access Control pop-up window displays.


3. Click Yes. The Registry Editor screen displays.

4. In left pane, click Computer > HKEY_CURRENT_USER > Software > Microsoft > Windows > Cur-
rentVersion > Explorer > Shell Folders > Personal. Double-click on the Personal folder to make

11 January 2018 © Caterpillar 2001-2018 97 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

changes to values, if required.

NOTE: Also check for the personal folder value in the following path HKEY_CURRENT_
USER\Software\Microsoft\Windows\CurrentVersion\Explorer\User Shell
Folders\Personal in the same Registry Editor screen.

After the DB2 database installation, if there are any problems, check User Rights Assignment in the below
screen. In particular, the user 'db2admin' needs to be a member of the User Right Assignment "Log on as a
service" or else the DB2 service will not be operational and VIMSpc will not be able to connect to the DB2
database.

98 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

11 January 2018 © Caterpillar 2001-2018 99 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Issue in DB2 Database Connection


Cause #1

While trying to run VIMSpc the following error message appears 'Couldn't connect to VIMSpc Database'. The
problem is caused because the database is not created.

Solution #1

To create manual database in DB2 Database

1. Go to Start > All Programs, click IBM DB2 > DB2_VIMSPC (Default) > General Administrative
Tools > Control Center.

100 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

2. The Control Center screen appears.

11 January 2018 © Caterpillar 2001-2018 101 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

3. Under All Systems, click Expand icon to check if Database instance (DB2_01) is created as

shown below.

102 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

4. Right-click on the All Databases and select Create Database > Standard.

11 January 2018 © Caterpillar 2001-2018 103 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

5. The Create Database Wizard screen appears. Enter Database Name and Click Browse to browse

the database default path.

6. Click Finish. The following pop-up appears.

104 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

7. Click Close. The DB2 Message pop-up appears with the following message.

8. Click Close.

11 January 2018 © Caterpillar 2001-2018 105 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

9. Under All Databases, click Expand icon to check if database (VIMS3G) is created as shown

below.

10. Close the Control Center.

106 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

11. Type db2cmd in the Start. The db2cmd.exe appears. Right-click and select Run as Administrator.

11 January 2018 © Caterpillar 2001-2018 107 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

12. The db2cmd screen appears. Type db2set in the cmd. The following screen appears.

13. The following commands need to be executed when these values are not set in the above screenshot.
db2set DB2CODEPAGE=1208, db2set DB2TERRITORY=1, db2set DB2COUNTRY=1, & DB2_
GRP_LOOKUP=LOCAL, TOKENLOCAL.

108 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

14. Type DB2STOP to stop the DB2 services. The following success message appears.

15. Type DB2START to start the DB2 services. The following success message appears.

16. Type "C:\Program Files (x86)\Caterpillar\VIMS3G\VIMSCMD.EXE" "cd \"C:\Pro-


gram Files (x86)\Caterpillar\VIMS3G\Templates\" &\"C:\Program
Files\IBM\SQLLIB_VIMSPC\BIN\db2cmd.exe\" "/c /w /i db2 -tf CreateT-

11 January 2018 © Caterpillar 2001-2018 109 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

ables.db2". The following success message appears.

17. Try to launch VIMSpc application. The following pop-up appears.

18. Click Yes to let the application create database.

110 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Issue in JRE Components


Cause #1

In VIMSpc Merge screen, when the user select VIMS files to merge into VIMSpc database for reporting, the
following error message is displayed if the Java components are not installed.

Solution #1

To enable Java for Browsers option

1. Go to Start and select > Control Panel, and click View By list and select Large Icons or Small
Icons.

11 January 2018 © Caterpillar 2001-2018 111 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

2. The following list appears. Click Java.

112 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

3. The Java Control Panel pop-up appears. Under Security tab, check the Enable Java content in the
browser.

NOTE: For lower versions of Java, open the web browser, go to Tools > Internet Options >
Advanced tab to enable the java content.

4. Click OK.

11 January 2018 © Caterpillar 2001-2018 113 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Issues while running VIMSpc update


Cause #1

Error while running the VIMSpc update.

Solution #1

VIMS database files (.mdb), VIMSpc application, and all DB2 database applications should not be kept open
while running the VIMSpc update, doing so will result in loss of data. User would be prompted to close the
existing opened VIMS mdb files if any, before proceeding update.

The following cmd appears. Press any key to continue.

114 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Following screen displays while trying to run the update when VIMSpc is running. Exit from VIMSpc and try
installing the update.

NOTE: For more assistance with this software, contact your Caterpillar Dealer and the Dealer will con-
tact the DSN team.

11 January 2018 © Caterpillar 2001-2018 115 / 126


VIMSpc Installation Manual 5.4
Uninstalling VIMSpc
VIMSpc
Installation Manual

Uninstall VIMSpc
This chapter describes how to uninstall VIMSpc.

NOTE: The account used to uninstall VIMSpc on a computer needs Administration privileges.

To uninstall VIMSpc

1. Go to Start > Control Panel > Programs > Uninstall a program.

118 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

2. Find the VIMSpc installation, and select it.

11 January 2018 © Caterpillar 2001-2018 119 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

3. Right-click on the VIMSpc and click Uninstall/Change/Repair.

NOTE: Change or Repair - Modify and make changes to the VIMSpc missing components, if
necessary.

4. If Uninstall is clicked, the following confirmation message is displayed.

120 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

5. Click Yes. The User Access Control confirmation message is displayed.

NOTE: Clicking No to stop the uninstallation process.

6. Click Yes. The VIMSpc is uninstalled successfully.

Complete Uninstallation of VIMSpc


This section describes how to uninstall DB2 Database.

NOTE: Uninstall the DB2 Database to complete the uninstallation of VIMSpc. The account used to
uninstall DB2 Database on a computer needs Administration privileges.

To uninstall IBM DB2 database

1. Go to Start > Control Panel, under Programs, click Uninstall a program.

11 January 2018 © Caterpillar 2001-2018 121 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

2. Find the DB2 installation, and select it.

122 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

3. Right-click on the VIMSpc and click Uninstall/Change/Repair.

NOTE: Change or Repair - Modify and make changes to the IBM DB2 Database components,
if necessary

4. If Uninstall is clicked, the following confirmation message is displayed.

5. Click Yes. The User Access Control confirmation message is displayed.

11 January 2018 © Caterpillar 2001-2018 123 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

NOTE: Click No to stop the uninstallation process.

6. Click Yes. The uninstallation begins and the following progress bar is displayed.

7. Once the progression is completed, the following pop-up window is displayed.

8. Click OK. The confirmation pop-up is displayed.

9. Click Yes. The IBM DB2 Database is uninstalled successfully.


10. Restart the PC.

124 / 126 © Caterpillar 2001-2018 11 January 2018


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

Glossary

CAT® ET
CAT Electronic Technician communicates with the Electronic Control Modules
(ECMs) through a communication data link, allowing existing and potential prob-
lems to be diagnosed, products to be configured, and data to be obtained for ana-
lysis.

COM Port
Communication Ports

CSV
Comma Seperated Value is a file that stores tabular data (number & text) in a
plain text form.

Data Migration
Move the data from older version of VIMSpc into current database

Datalogger Select box


The Datalogger Select button in Datalogger pane will list the available data-
loggers for the selected TimeRange and Machine. Based on the selection of data-
loggers in Select wizard, parameters pane will get updated.

DB2
Relational DataBase Management System introduced by IBM

11 January 2018 © Caterpillar 2001-2018 125 / 126


VIMSpc Installation Manual 5.4
VIMSpc
Installation Manual

ECM
The Electronic Control Module (ECM) is an embedded system that controls an
aspect of the machine, such as temperature and pressure sensors.

Ethernet Connection
Ethernet Connection utilizes the Local Area Network (LAN) to connect with the
Electronic Control Module (ECM) to communicate with machine.

LAN
The Local Area Network is a group of computers and associated devices that
share a common communication line to a server

Serial Connection
Serial connection utilizes the serial port on laptop, or USB port through a USB-to-
Serial adapter to communicate with the machine.

126 / 126 © Caterpillar 2001-2018 11 January 2018