Selection Guide.................................. F-2

Sockets
Din Rail Snap/Surface-Mount
Sockets
• SU Series . . . . . . . . . . . . . . . . . . . ..F-6

F
New • SJ Series . . . . . . . . . . . . . . . . . . . . ..F-9
New • SQ Series . . . . . . . . . . . . . . . . . . . F-10
• SR Series . . . . . . . . . . . . . . . . . . . F-11
• SH Series . . . . . . . . . . . . . . . . . . . F-14
• SY Series . . . . . . . . . . . . . . . . . . . F-18
• SM Series . . . . . . . . . . . . . . . . . . . F-20

Through Panel Mount Sockets


• SR Series . . . . . . . . . . . . . . . . . . . F-21
• SH Series . . . . . . . . . . . . . . . . . . . F-22
• SY Series . . . . . . . . . . . . . . . . . . . F-24

PCB Mount Sockets


• SH Series . . . . . . . . . . . . . . . . . . . F-25
• SY Series . . . . . . . . . . . . . . . . . . . F-26

Panel Mounted Sockets for Timers


• SR Series . . . . . . . . . . . . . . . . . . . F-28

Accessories ....................................... F-29

Dimensions....................................... F-31

for more information on this product family visit


www.idec.com/socket
www.idec.com/socket
Additional Web Resources
• New and updated product information
• Downloadable software demos & upgrades
• Part configuration tool & cross reference
• Online stock check & ordering
• IDEC field sales & distributor search
• Online literature request
• Downloadable manuals & CAD drawings
• Manufacturer’s suggested retail price list
• Product training schedule & locations
• Advertising & trade show schedules
• Press releases & FAQs
Selection Guide Sockets
Relay and Timer Socket Selection Guide
Relay and Timer Socket
No. of Compatible
Mounting Series Page Part No. Receptacle Terminal
Poles IDEC Relay and Timer

DIN Rail Snap/Surface-Mount SU2S-11L 2 8-Blade RU2, RM2


Spring Clamp
SU F-6 Terminals
SU4S-11L 4 14-Blade RU4, RU42, RY4, RY42
SR2P-05 RR2P, GT5P,
SR2P-05C 2 8-Pin RTE-P1, GT3 (8-pin)
SR2P-06
SR F-11 SR3P-05 M3.5 Screw RR3PA, RR2KP, RTE-P2
SR3P-05C 3 11-Pin GT3 (11-pin)
SR3P-06
SR3B-05 3 11-Blade RR1BA, RR2BA, RR3B, RTE-B
SH1B-05 M3.5 Screw
1 5-Blade RH1B
SH1B-05C Coil Terminal: M3
SH2B-05 2 8-Blade RH2B
SH2B-05C
SH F-14
SH3B-05 3 11-Blade M3.5 Screw RH3B, RH2LB
SH3B-05C
SH4B-05 4 14-Blade RH4B
SH4B-05C
SY2S-05 2 8-Blade RY2S, RY22S
F SY F-18
SY2S-05C
SY4S-05
M3 Screw
RU4S, RU42S, RY4S, RY42S, RY2KS, RM2S,
4 14-Blade
SY4S-05C GT5Y
Sockets

SM2S-05
SM F-20 2 8-Blade M3 Screw RU2S, RM2S
SM2S-05C
SJ1S-05B 1 5-Blade RJ1S
SJ1S-07L
SJ F-9
SJ2S-05B 2 8-Blade RJ2S
SJ2S-07L
M3 Screw
SQ1V-07B 1 5-Blade RQ1V-CM
SQ F-10
RQ2V-CN
SQ2V-07B 2 8-Blade RQ1V-CH
Through Panel Mount SR2P-51 2 8-Pin RR2P, GT5P, RTE-P1, GT3 (8-pin)
SR F-21 SR3P-51 3 11-Pin RR3PA, RR2KP, RTE-P2, GT3 (11-pin)
SR3B-51 3 11-Blade RR1BA, RR2BA, RR3B
SH1B-51 1 5-Blade RH1B
SH2B-51 2 8-Blade Solder RH2B
SH F-22
SH3B-51 3 11-Blade RH3B, RH2LB
SH4B-51 4 14-Blade RH4B
SY2S-51 2 8-Blade RY2S, RY22S
SY F-24 RY4S, RY42S, RU4S, RU42S, RY2KS, RM2S,
SY4S-51 4 14-Blade GT5Y
PCB Mount SH1B-62 1 5-Blade RH1B
SH2B-62 2 8-Blade RH2B
SH F3-25
SH3B-62 3 11-Blade RH3B, RH2LB
SH4B-62 4 14-Blade RH4B
SY2S-61 2 8-Blade PC Board RY2S, RY22S
RY4S, RY42S, RU4S, RU42S, RY2KS, RM2S,
SY4S-61 4 14-Blade
SY F3-26 GT5Y
RY4S, RY42S, RU4S, RU42S, RY2KS, RM2S,
SY4S-62 4 14-Blade GT5Y
For Panel Mounted Timers
SR6P-M08G 8-pin GE1A; RTE-P1; GT3 (8-pin);
SR F-28 2 M3.5 Screw
SR6P-M11G 11-pin RTE-P2; GT3 (11-pin)

For relay mounting accessories, see page F-29.

F-2 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets Selection Guide

Specifications

SU, SR, SH, SM, SY


Rated Insulation Voltage 300V; except SH1B, SU and SY4S-62: 250V
SU2/SR/SH/SM: 10A, SY: 7A, SU4: 6A with RU4,
Rated Current
Specifications

SU4: 10A with RU2 (SH1B: 7A)


Insulation Resistance 100MΩ minimum
Dielectric Strength 2,000V AC, 1 minute
Material Grade UL94V-0
3.5mm Screws, 9-11.5 in•lbs
Terminal Torque 3mm screws, 5.5-9 in•lbs
1. * Applicable to DIN rail sockets only.

UL Recognized
CSA Certified
File No. E62437
File No.LR35144

Sockets
File No. BL950813332307

SJ, SQ
Specifications SJ Series SQ Series
Rated Current SJ1S: 12A Max; SJ2S: 8A Max SQ1V: 12A Max; SQ2V: 10A Max
Rated Voltage 250V 300V
Applicable Wire 2x #14 (2.5mm2) 2x #14 (2.5mm2)
Applicable Crimping Terminal 2mm2 x 2 1.5mm2 x 2
Terminal Torque 0.6 to 1.0Nm 1.0Nm Max
Screw Size M3 Slotted Phillip Captive Screw M3 Slotted Phillip Captive Screw
Dielectric Strength (Coil/Contact) 4,000VAC 3,000VAC
Insulation Resistance ≥100 MΩ Minimum ≥100 MΩ Minimum
Operating Temperature -40 to 70°C (no freezing) -25 to +85°C
Operating Humidity 5~85% RH (no condensation) 45~85% RH

CSA Certified UL Recognized


File No.LR84913 File No. E62437

UL Recognized
File No. E141060

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-3
Selection Guide Sockets
Hold-Down Springs and Clips Selection Guide
DIN Rail Snap/Surface-Mount Sockets
Hold-Down Clip Hold-Down Clip
Socket Part No. Applicable Relays, Timer Hold-Down Pullover Spring
(side latch) (top latch)
RM2S, RU2, GT5Y-2 SY4S-51F1 SFA-202 SFA-101
SU2S-11L
SU4S-11L RY4S, RY42S, RU4, RU42, SY4S-51F1 SFA-202 SFA-101
GT5Y, RY2KS, RM2S

SR2P-05 RR2P SR2B-02F1 SFA-203 —


SR2P-05C RTE-P1, GT3, GT5P — SFA-203 —
RR2P SR2B-02F1 SFA-202 —
SR2P-06
GT3 (8-pin), RTE-P1, GT5P — SFA-202 —
RR3PA SR3B-02F1 SFA-203 —
SR3P-05 RR2KP SR3P-06F3 SFA-203 —
SR3P-05C
RTE-P2, GT3 (11-pin) — SFA-203 —
RR3PA SR3B-02F1 SFA-202 —
SR3P-06 RR2KP SR3P-06F3 SFA-202 —
RTE-P2, GT3 (11-pin) — SFA-202 —
SR3B-05 RR1BA, RR2BA, RR3B, RTE-B SR3B-02F1 SFA-202 —
F SH1B-05 RH1B SY2S-02F1 SFA-202 SFA-101
SH1B-05C
Sockets

SH2B-05 RH2B SY4S-02F1 SFA-202 SFA-101


SH2B-05C
SH3B-05 RH3B, RH2LB SH3B-05F1 SFA-202 SFA-101
SH3B-05C
SH4B-05 RH4B SH4B-02F1 SFA-202 SFA-101
SH4B-05C
SY2S-05 RY2S, RY22S SY2S-02F1 SFA-202 SFA-101
SY2S-05C
RY4S, RY42S, RU4, RU42,
SY4S-05 SY4S-51F1 SFA-202 SFA-101
RM2S
SY4S-05C
RY2KS, GT5Y (SY4S-51F3) SFA-202
SM2S RM2S, RU2 SY4S-51F1 SFA-202 SFA-101
SJ1S RQ1S SJ9Z-C
SJ2S RJ2S
SQ1S RQ1V SQ9Z-C
SQ2S RQ2V
1. Hold-down springs work in conjunction with hold-down spring anchors included with DIN rail sockets.
2. When mounting relays with a check button onto panel mount or PC board mount sockets, use the hold-down spring shown in parenthesis. Hold-down
springs for relays with check buttons are not available for SR2P-51.
3. For close mounting of panel mount or PC mount sockets, use hold-down clips rather than hold-down springs.
4. SFA-101, SFA-202 and SFA-302 come in pairs.

SR2B-02F1 SR3B-02F1 SY4S-02F1 SH3B-05F1 SH4B-02F1

SY4S-51F3 SR3P-01F1 SR3P-06F3 SY2S-02F1


SY4S-51F1

F-4 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets Selection Guide

Panel and PC Board Mount Sockets


Hold-Down Clip Hold-Down Clip
Socket Part No. Applicable Relays, Timer Hold-Down Pullover Spring
(side latch) (top latch)
RR2P SR3P-01F1 — —
SR2P-51
GT3 (8-pin), RTE-P1 — SFA-402 —
RR3PA SR3P-01F1 —

SR3P-51 RR2KP SR3P-51F3 —
GT3 (11-pin), RTE-P2 — SFA-402 —
RR1BA, RR2BA,
SR3B-51 SR3B-02F1 — —
RR3B, RTE-B
SH1B-51 SFA-301
RH1B SY4S-51F1 —
SH1B-62 SFA-302
SY4S-51F1 SFA-301
SH2B-51 RH2B —
(SY4S-02F1) SFA-302
SY4S-51F1
SH2B-62 RH2B (SY4S-02F1) — —

SH3B-51 SY4S-51F1 SFA-301


RH3B, RH2LB —
SH3B-62 (SY4S-02F1) SFA-302
SH4B-51 SY4S-51F1 SFA-301
RH4B —
SH4B-62 (SH4B-02F1) SFA-302
SY2S-51 SFA-301
RY2S, RY22S SY4S-51F1 —
SY2S-61 SFA-302
F
SY4S-51F1 SFA-301
RY4S, RY42S —
(SY4S-02F1) SFA-302

Sockets
SY4S-51
SY4S-61 SY4S-51F1
RY2KS SFA-302 —
(SY4S-02F3)
GT5Y — SFA-302 —
SY4S-51F1
RY4S, RY42S, RM2S — —
(SY4S-02F1)
SY4S-62 *
SY4S-51F1
RY2KS — —
(SY4S-02F3)
* Does not accept hold down clips

SFA-202
SFA-302
SFA-101

SFA-402
SFA-301 SFA-203

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-5
SU Series: DIN Rail Snap-Mount Sockets
SU Series: DIN Rail Snap-Mount Sockets

SU2S-11L SU4S-11L
Style 8-blade DIN-mount/surface mount Style 14-blade DIN-mount/surface mount
Terminal Spring clamp terminals Terminal Spring clamp terminals
Wire Size 24-16 AWG Wire Size 24-16 AWG
Electrical Rating 10A Electrical Rating 6A (using RU4), 10A (using RU2)
Compatible Relay RU2, RM2 Compatible Relay RY4S, RY42S, RU4, RU42S, RY2KS, RM2S
Compatible Timer GT5Y-2 Compatible Timer GT5Y

F Hold-Down Clip SFA-101 (top latch), SFA-202 (side latch) Hold-Down Clip SFA-101 (top latch), SFA-202 (side latch)

1. On the SU2S, wires or ferrules cannot be connected to terminals 2, 3, Inside the Cable Ports
Sockets

6, 7, 10 or 11 because neither springs nor conductive brackets are


installed in these terminals.
2. For socket mounting accessories, see page F-29.
Inside the Cable Ports

Terminal Arrangement (top view) Dimensions


SU2S-11L SU4S-11L Center of Relay-mounting area 31

12 11 10 9 12 11 10 9

8 7 6 5 8 7 6 5

4 3 2 1 4 3 2 1
80

14 13 14 13
37.5

Parts
28.8

Screwdriver Ports
Wire Wire Wire Wire
Ports Ports Ports ➃ ➄ ➅ Ports

Marking Plate
32
35.3
Spring slots for SFA-101:
➀➁➄➅
4.4

Spring slots for SFA-202:


➁➂➃➄
Panel Cutout for Surface Mounting
24
Clamp
C NO NC ➀ ➁ ➂ Coil
Terminal Terminal Terminal Terminal
All dimensions are in mm.

F-6 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets SU Series: DIN Rail Snap-Mount

SU Series: General Instructions

Applicable Wires Wiring Instructions


Wire Ports for Terminal 9
Wire Size
Wire Port Wire Ports for Terminal 10
A
Stranded wire 0.2 to 1.25 mm2 or AWG24 to 16
Solid wire 0.2 to 1.5 mm2 or AWG24 to 16
Wire insulation diameter ø3.15mm maximum

1. Strip the wire insulation 9 to 10mm from the end.


2. In applications using ferrules for stranded wires, choose Stopper A - B sec Correct Incorrect
the ferrule listed in table below. Make sure that an insula- Screwdriver Ports B Incorrect Incorrect
tion sheath is applied when using the ferrules. When using Direction of Screwdriver Tip
Note: Two cable ports are provided for each terminal.
stranded wires without ferrules, make sure that the core
wires have not been loosened. 1. Insert the optional screwdriver
3. Two cable ports are provided for each terminal. (BC1S-SDO) or an applicable
screwdriver into the square-
shaped port as shown on the right,
until the screwdriver tip touches
9 to 10mm the bottom of the spring.
2. Push in the screwdriver until it
touches the bottom of the port.
The wire port is now open, and the

Applicable Ferrules
screwdriver is held in place. The
screwdriver will not come off even
F
Applicable Wire (stranded) if you release your hand.

Sockets
Type Manufacturer 3. While the screwdriver is
mm2 AWG retained in the port, insert the wire
0.2 24 A10.25-12BU Phoenix Contact or ferrule into the round-shaped
wire port. Each wire port can
_ 22 A10.34-8TQ Phoenix Contact accommodate one wire or ferrule.
A10.5-8WH When connecting two wires to one
Phoenix Contact terminal, use the adjoining port of
0.5 20 A10.5-10WH the same terminal.
TE0.5 Nichifu Co. Ltd 4. Pull out the screwdriver. The
connection is now complete.

For wiring, use the optional screwdriver (BC1S-SDO) or the Safety Precautions
following applicable screwdriver.
Installing the Marking Plate
(Dimensions in mm)
Because of its removable structure, the marking plate may have fallen from
the socket or become loose in delivery. Make sure that the marking plate is
securely installed before starting operation. The marking plate protects the
conductive portion of the socket, located under the marking plate, by prevent-
2.5

ing metal fragments or pieces of wire from dropping inside. Should any such
0.4

º
13

ø 2.5

fragments enter the socket, they may cause fire hazard, damage, or malfunc-
7to

tion.
Jumper Ports Marking Plate

Marking Instructions
Write markings on the SU sockets using an oil-based marker, or glue printed
mylar on the marking surface. The size of the printed mylar can be 8 x 9mm
maximum. plate ribs
No marking plate Loose fitting Installed securely (on both sides)
Marking Surface r Jumper
Note: For installation of optional
p jumper,
j p
8.0 8.0 see the instruction sheet provided
with the jumper.
9.0

Inserting Screwdriver into the Wire Ports


Maximum size of Position of printed
printed mylar mylar on the marking
Marking Plate surface

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-7
SU Series: DIN Rail Snap-Mount Sockets
SU Series: SU9Z-J5 Jumper Installation Instructions

SU9Z-J5 Jumper for SU2S-11L and SU4S-11L Installing Two, Three or Four SU Sockets on the SU9Z-J5
Jumper
The SU9Z-J5 is used to install five sockets. When installing less than five
sockets cut the jumper according to the instructions listed to the right. As shown below, slide the jumper in the sheath so that the jumper aligns with
The SU9Z-J5 jumper is for coil terminals only. the center of the sheath.

SU9Z-95 Jumper
Jumper off center Jumper on center
Rated Current 3A
With the sheath properly installed on the jumper, cut the sheath and
Conductor Nickel-plated brass jumper at the points shown below, using cutting pliers. Referring to the
Material
Sheath ABS resin drawing on the right, make sure that the sheath and jumper are cut
within the cutting area. Dispose of unused portions according to local
waste disposal requirements.
Installation
Y Z Shea
Loosen the marking plate on the socket.
X
Jump
Shea

Cutting Area C Cutting Area D

Cutting Area in Detail


A B CD
A: Loose fitting B: Installed securely
Qty Cutting Area Discard
F 2 Sockets 2 A, C Y
2 Sockets
Sockets

1 A, B X
3 Sockets
4 Sockets 1 D Z
Ribs
After cutting the jumper and sheath, slide the jumper as shown below, so that
the ends of the jumper ar e not exposed.

Grooves for marking plate ribs


(on both sides)

Alignment Jumper Wiring to Six or More SU Sockets


Making sure that the SU9Z-J5 jumper is correctly aligned, insert the blades To jumper wire six or more SU sockets, connect five sockets using whole
into the ports in the groove of the SU sockets. jumpers and the remaining sockets using a cut jumper. Then connect the two
terminals on adjoining sockets using an applicable wire (see table below).
Incorrect Correct
Proper wire

Insertion Direction

Jumper port
for terminal 13 Wire Size
Jumper port
for terminal 14 Stranded wire 0.2 to 1.25 mm2
Blade
Solid wire 0.2 to 1.5 mm2
AWG 24 to 16

1. Use a wire with cable insulation diameter of ø3.15mm


Jumper Groove Jumper maximum.
2. Strip the cable insulation 9 to 10mm from the end.
Install Jumper Securely
Safety Precautions
Press down the marking plate to secure the jumper. The jumper installation is
now complete. Turn off the power to the SU9Z-J5 jumper before starting installation,
removal, wiring, maintenance, or inspection of the jumper. Failure to turn
power off may cause an electrical shock or fire hazard.
To avoid a short circuit due to incorrect wiring, confirm which terminals are
connected to the jumper before beginning wiring.

F-8 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets SJ Series: DIN Rail Snap-Mount

SJ Series: General Information

SJ1S-05B
Style 5 -blade snap mount/surface mount
Terminal/Torque 0.6 - 1.0N•m (Maximum 1.2N•m)
Wire Size Maximum up to 2 - #14 AWG
Electrical Rating 250V, 12A
Compatible Relay RJ1S
Compatible Timer N/A
Hold-Down Spring N/A
Replacement Locking Lever SJ9Z-C

Sockets
SJ1S-07L Fingersafe
Style 5-blade, snap mount/surface mount
Terminal/Torque 0.6 - 1.0N•m (Maximum 1.2N•m)
Wire Size Maximum up to 2 - #14 AWG
Electrical Rating 250V, 12A
Compatible Relay RJ1S
Compatible Timer N/A
Hold-Down Spring N/A
Replacement Locking Lever SJ9Z-C

SJ2S-05B
Style 8-blade, snap mount/surface mount
Terminal/Torque 0.6 - 1.0N•m (Maximum 1.2N•m)
Wire Size Maximum up to 2 - #14 AWG
Electrical Rating 250V, 8A
Compatible Relay RJ2S
Compatible Timer N/A
Hold-Down Spring N/A
Replacement Locking Lever SJ9Z-C

All dimensions are in mm.

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-9
SJ/SQ Series: DIN Rail Snap-Mount Sockets

SJ2S-07L Fingersafe
Style 8-blade snap mount/surface mount
Terminal/Torque 0.6 - 1.0N•m (Maximum 1.2N•m)
Wire Size Maximum up to 2 - #14 AWG
Electrical Rating 250V, 8A
Compatible Relay RJ2S
Compatible Timer N/A
Hold-Down Spring N/A
Replacement Locking Lever SJ9Z-C

All dimensions are in mm.

SQ Series: General Information


F
Sockets

SQ1V-07B Fingersafe
Style 5-pin, snap mount/surface mount
Terminal/Torque 1.0N•m Maximum
Wire Size Maximum up to 2 - #14 AWG
Electrical Rating 300V, 12A
Compatible Relay RQ1V-CM
Replacement Locking Lever SQ9Z-C
Replacement Marking Plate SQ9Z-P
Plug-in LED/Diode (6-24VDC) SQ9Z-LD
Plug-in LED/RC (120/240VAC) SQ9Z-LR

SQ2V-07B Fingersafe
Style 8-pin, snap mount/surface mount
Terminal/Torque 1.0N•m Maximum
Wire Size Maximum up to 2 - #14 AWG
Electrical Rating 300V, 8A
Compatible Relay RQ2V, RQ1V-CH
Replacement Locking Lever SQ9Z-C
Replacement Marking Plate SQ9Z-P
Plug-in LED/Diode (6-24VDC) SQ9Z-LD
Plug-in LED/RC (120/240VAC) SQ9Z-LR
All dimensions are in mm.

F-10 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets SR Series: DIN Rail Snap-Mount

SR Series: DIN Rail Snap-Mount Sockets

SR2P Sockets

36 32 when
using BAA
SR2P-05 8 DIN Rail (BAA) Terminal
M3.5 Screw Arrangement
Style 8-pin octal, snap-mount/surface mount 2-ø4.2 Mounting Hole 5 4
(M4 screw hole)
M3.5 screws with captive wire clamp 6 3
Terminal/Torque (9 - 11.5 in•lbs)

ø25

52
52

33
29
Wire Size Maximum up to 2–#12AWG 7 2

4.4max. 5min. 8 1
Electrical Rating 300V, 10A ø4.2 (TOP VIEW)
16.5

3
Mounting

3
Compatible Relay RR2P 29 Hole 20
7.9max.
Compatible Timer RTE-P1, GT3 (8-pin), GT5P, GE1A 28.5
ø3.6min.
Hold-Down Spring SR2B-02F1 (for RR2P)
Hold-Down Clip SFA-203 (for timers only, except GE1A)
F

Sockets
36 33.5 when
SR2P-05C Fingersafe using BAA
7
Style 8-pin octal, snap-mount/surface mount DIN Rail (BAA) Terminal
Arrangement
M3.5 screws with captive wire clamp, 2-ø4.2 Mounting Hole
Terminal/Torque fingersafe (9 - 11.5 in•lbs) 5 4 5
(M4 screw hole)
5 4
6 3
6 3
Wire Size Maximum up to 2–#12AWG
58

29
Electrical Rating 300V, 10A 4. 7 2
2
7 2 8 1
Compatible Relay RR2P 8 1 (TOP VIEW)
Compatible Timer RTE-P1, GT3 (8-pin), GT5P, GE1A
2.2

29 21.5
Hold-Down Spring SR2B-02F1 (for RR2P) (cannot use ring terminal)
30
Hold-Down Clip SFA-203 (for timers only, except GE1A)

40
SR2P-06 8
25.5 when Terminal
using BAA
DIN Rail (BAA)
Style 8-pin octal, snap-mount/surface mount Arrangement
M3.5 Screw 2-ø4.2 Mounting Hole 6 5 4 3
M3.5 screws with captive wire clamp
Terminal/Torque (9 - 11.5 in•lbs)
(M4 screw hole)
ø25
60

Wire Size Maximum up to 2–#12AWG


33
Electrical Rating 300V, 10A 4.9max. 5min.
ø4.2 7 8 1 2
Compatible Relay RR2P 33 Mounting ø3.6min. (TOP VIEW)
18
Compatible Timer RTE-P1, GT3 (8-pin), GT5P, GE1A Hole
1

22 7.9max.

Hold-Down Spring SR2B-02F1 (for RR2P)


Hold-Down Clip SFA-202 (for timers only, except GE1A)

1. For socket mounting accessories, see page F-29. All dimensions are in mm.
2. For hold-down clip/spring selections, see page F-4.

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-11
SR Series: DIN Rail Snap-Mount Sockets
SR3P Sockets

SR3P-05 42 32 when
using BAA
8 DIN Rail (BAA) Terminal
Style 11-pin octal, snap-mount/surface mount M3.5 Screw Arrangement
2-ø4.2 Mounting Hole
M3.5 screws with captive wire clamp 7 6 5
Terminal/Torque (M4 screw hole)
(9 - 11.5 in•lbs) 8 4

ø27
52

33
Wire Size Maximum up to 2–#12AWG 34
9 3
Electrical Rating 300V, 10A 4.4max. 5min. 10 11 1 2
ø4.2 (TOP VIEW)
Compatible Relay RR3PA, RR2KP 34 Mounting 16.5 ø3.6min.
Hole 20
Compatible Timer GT3 (11-pin), RTE-P2

3
7.9max.
28.5
Hold-Down Spring SR3B-02F1 for RR3P; SR3P-06F3 for RR2KP
Hold-Down Clip SFA-203 (Timers)

F
Sockets

SR3P-05C Fingersafe 42 33.5 when


7 using BAA
Style 11-pin octal, snap-mount/surface mount Terminal
DIN Rail (BAA)
Arrangement
M3.5 screws with captive wire clamp,
5

Terminal/Torque 2-ø4.2 Mounting Hole


ø

7 6 5 7 6 5
fingersafe (9 - 11.5 in•lbs) (M4 screw hole)
8 4 8 4

Wire Size Maximum up to 2–#12AWG


58

ø4 34
Electrical Rating 300V, 10A .2 9 3
9 3 10 11 1 2
Compatible Relay RR3PA, *RR2KP (*latching relay) 1 1
1 1 (TOP VIEW)
0 2
2.2

Compatible Timer GT3 (11-pin), RTE-P2 (cannot use ring terminal)


34 21.5
Hold-Down Spring SR3B-02F1 for RR3PA; SR3P-06F3 for RR2KP 30
Hold-Down Clip SFA-203 (Timers)

SR3P-06
Style 11-pin octal, snap-mount/surface mount
59 25.5 when
M3.5 screws with captive wire clamp 8 using BAA
DIN Rail (BAA) Terminal
Terminal/Torque Arrangement
(9 - 11.5 in•lbs) M3.5 Screw
2-ø4.2 Mounting Hole 8 7 6 5 4

Wire Size Maximum up to 2–#12AWG (M4 screw hole)


ø27
60

Electrical Rating 300V, 10A


33
Compatible Relay RR3PA, *RR2KP (*latching relay) ø4.2 4.9max. 5min.
9 10 11 1 2 3
Mounting
Compatible Timer GT3 (11-pin), RTE-P2 Hole 18 ø3.6min. (TOP VIEW)
33
1

Hold-Down Spring SR3B-02F1 for RR3PA; SR3P-06F3 for RR2KP 22 7.9max.

Hold-Down Clip SFA-202 (Timers)

1. For socket mounting accessories, see page F-29. All dimensions are in mm.
2. For hold-down clip/spring selections, see page F-4.

F-12 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets SR Series: DIN Rail Snap-Mount

SR3B Sockets

36 When using
BAA/BAP: 28.5 DIN Rail Terminal Arrangement
8 M3.5 Terminal (BAA/BAP)
Screw 6 5 4
2-ø4.2 Mounting Holes 3 2 1
(or M4 Tapped Holes)

4.2
SR3B-05
37

76

56
Style 11-blade, snap-mount/surface mount
B A
4.4 max. 5.5 min.
M3.5 screws with captive wire clamp 9 8 7
Terminal/Torque (9 - 11.5 in•lbs) (Top View)
7.9 max.
Wire Size Maximum up to 2–#12AWG 37 14.5 ø3.6 min.

2
43 25
Electrical Rating 300V, 15A (10A)* (*denotes CSA rating)
Compatible Relay RR1BA, RR2BA, RR3B
All dimensions are in mm.
Compatible Timer RTE-B
Hold-Down Spring SR3B-02F1 (relays)
Hold-Down Clip SFA-202 (relays and timers)

Sockets

1. For socket mounting accessories, see page F-29.


2. For hold-down clip/spring selections, see page F-4.

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-13
SH Series: DIN Rail Snap-Mount Sockets
SH Series: DIN Rail Snap-Mount Sockets

SH1B Sockets

When using
17 BAA/BAP: 28.5
8 18 DIN Rail Terminal Arrangement
M3.5 Terminal
(BAA/BAP)
Screw 2-ø4.2 Mounting Holes
SH1B-05 (or M4 Tapped Holes)
5
1

4.2
Style 5-blade, snap-mount/surface mount
(Coil) M3 screws/(5.5 - 9 in•lbs) (contact)

67

47
16
Terminal/Torque M3.5 screws (9 - 11.5 in•lbs)
with captive wire clamp M3 Terminal 5.5 min. 4.8 min. 14 13

Screw 9
4.4 max. 4 max.
Wire Size Maximum up to 2–#12AWG (Top View)
16 14.5 ø3.6 min. ø3.2 min.
Electrical Rating 250V, 10A
2.5

20 25
7.9 max. 5.9 max.
Compatible Relay RH1B
F Hold-Down Spring SY2S-02F1 (For terminals 1, 5, and 9) (For terminals 13 and 14)

Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch)


Sockets

When using
17 BAA/BAP: 33
M3.5 Terminal
7 25
Screw DIN Rail Terminal Arrangement
SH1B-05C Fingersafe (BAA/BAP)
ø5 5
Style 5-blade, snap-mount/surface mount 2-ø4.2 Mounting Holes 1
(or M4 Tapped Holes)
4.2

(Coil) M3 screws/(5.5 - 9 in•lbs) (contact)


Terminal/Torque M3.5 screws with captive wire clamp,
48
69

fingersafe (9 - 11.5 in•lbs) 16


M3 Terminal
Wire Size Maximum up to 2–#12AWG Screw 14 13

Electrical Rating 250V, 10A Ring type crimping


16 18.7 (Top View)
terminals cannot be used.
1.7

Compatible Relay RH1B 20 29.5

Hold-Down Spring SY2S-02F1


Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch)

1. For socket mounting accessories, see page F-29. All dimensions are in mm.
2. For hold-down clip/spring selections, see page F-4.

F-14 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets SH Series: DIN Rail Snap-Mount

SH2B Sockets

When using
22 BAA/BAP: 28.5
8 M3.5 Terminal 18 DIN Rail
(BAA/BAP) Terminal Arrangement
Screw
SH2B-05 2-ø4.2 Mounting Holes 8 5
(or M4 Tapped Holes)

4.2
Style 8-blade, snap-mount/surface mount 4 1

M3.5 screws with captive wire clamp

67

47
Terminal/Torque 26
(9 - 11.5 in•lbs)
4.4 max. 5.5 min. 14 13
Wire Size Maximum up to 2–#12AWG 12 9

Electrical Rating 300V, 10A 26 14.5 (Top View)


7.9 max.

2.5
Compatible Relay RH2B 30 25 ø3.6 min.

Hold-Down Spring SY4S-02F1


Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch)

Sockets
When using
22 BAA/BAP: 33
SH2B-05C Fingersafe 7 M3.5 Terminal 25 DIN Rail
Screw (BAA/BAP) Terminal Arrangement
Style 8-blade, snap-mount/surface mount
ø5 2-ø4.2 Mounting Holes 8 5
M3.5 screws with captive wire clamp, finger- (or M4 Tapped Holes) 4 1
Terminal/Torque
4.2

safe (9 - 11.5 in•lbs)


49
69

Wire Size Maximum up to 2–#12AWG 26

Electrical Rating 300V, 10A 14 13


12 9
Compatible Relay RH2B
18.7 Ring type crimping (Top View)
26
Hold-Down Spring SY4S-02F1 terminals cannot be used.
1.7

30 29.5
Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch)

1. For socket mounting accessories, see page F-29. All dimensions are in mm.
2. For hold-down clip/spring selections, see page F-4.

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-15
SH Series: DIN Rail Snap-Mount Sockets
SH3B Sockets

SH3B-05 28.5 when


using BAA
32
Style 11-blade, snap-mount/surface mount 8 18 Terminal
DIN Rail (BAA) Arrangement
M3.5 screws with captive wire clamp M3.5 Screw
Terminal/Torque 2-ø4.2 Mounting Hole 8 6 5
(9 - 11.5 in•lbs)

4.2
(M4 screw hole) 4 2 1

Wire Size Maximum up to 2–#12AWG

67

47
Electrical Rating 300V, 10A 36
4.4max. 5.5min.
Compatible Relay RH3B, RH2LB 14 13
12 10 9

Hold-Down Spring SH3B-05F1 (TOP VIEW)


36 14.5
7.9max.
Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) 2.5
40 25 ø3.6min.

F
Sockets

SH3B-05C Fingersafe
Style 11-blade, snap-mount/surface mount 33 when
32 using BAA

DIN Rail (BAA)


7 Terminal
M3.5 screws with captive wire clamp, M3.5 Screw 25
Terminal/Torque Arrangement
fingersafe (9 - 11.5 in•lbs) 8 6 5

44 24 14 2-ø4.2 Mounting Hole 8 6 5


ø5
Wire Size Maximum up to 2–#12AWG 42
4 2

22 12
1
(M4 screw hole) 4 2 1
4.2

Electrical Rating 300V, 10A


49

36
Compatible Relay RH3B, RH2LB
A2 A1 14 13
Hold-Down Spring SH3B-05F1 14

41 21
13

11
12 10 9
12 10 9
(cannot use ring terminal) (TOP VIEW)
Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch)
1.7

36 18.7
40 29.5

1. For socket mounting accessories, see page F-29. All dimensions are in mm.
2. For hold-down clip/spring selections, see page F-4.

F-16 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets SH Series: DIN Rail Snap-Mount

SH4B Sockets

28.5 when
SH4B-05 42 using BAA
Terminal
8 18
Style 14-blade, snap-mount/surface mount DIN Rail (BAA) Arrangement
M3.5 Screw
M3.5 screws with captive wire clamp 2-ø4.2 Mounting Hole 8 7 6 5

4.2
Terminal/Torque (M4 screw hole) 4 3 2 1
(9 - 11.5 in•lbs)

67

47
Wire Size Maximum up to 2–#12AWG 46
Electrical Rating 300V, 10A 4.4max. 5.5min. 14 13
12 11 10 9
Compatible Relay RH4B ø3.6min.
(TOP VIEW)
46 14.5
7.9max.
Hold-Down Spring SH4B-02F1

2.5
50 25

Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch)

Sockets
33 when
SH4B-05C Fingersafe 42 using BAA

Style 14-blade, snap-mount/surface mount 7 25

Terminal
M3.5 screws with captive wire clamp, 8 7 6 5
DIN Rail (BAA)
Terminal/Torque 44 34 24 14 Arrangement
fingersafe (9 - 11.5 in•lbs) 4 3 2 1 ø5
42 32 22 12
8 7 6 5
2-ø4.2 Mounting Hole
4.2

Wire Size Maximum up to 2–#12AWG (M4 screw hole) 4 3 2 1


69

49

Electrical Rating 300V, 10A


A2 A1 46
Compatible Relay RH4B 14

41 31 21
13

11 14 13
12 11 10 9
12 11 10 9
Hold-Down Spring SH4B-02F1
1.7

18.7 (cannot use ring terminal) (TOP VIEW)


46 29.5
Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch)
50

All dimensions are in mm.


1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-17
SY Series: DIN Rail Snap-Mount Sockets
SY Series: DIN Rail Snap-Mount Sockets

SY2S Sockets

28.5 when
17
using BAA
SY2S-05
6 18
Style 8-blade, snap-mount/surface mount Terminal
DIN Rail (BAA) Arrangement
M3 Screw
M3 screws with captive wire clamp 2-ø4.2 Mounting Hole 8 5
Terminal/Torque (5.5 - 9 in•lbs) (M4 screw hole) 4 1

Wire Size Maximum up to 2–#14AWG

62

45
16
Electrical Rating 300V, 7A

4.2
14 13
Compatible Relay RY2S, RY22S 4max. 4.8min.
12 9
ø3.2min.
(TOP VIEW)
Hold-Down Spring SY2S-02F1 16 14.5
20 25 5.9max.
2

F Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch)


Sockets

32.5 when
SY2S-05C Fingersafe using BAA
Style 8-blade, snap-mount/surface mount 17.2
25 Terminal
6
M3 Screw Arrangement
DIN Rail (BAA)

M3 screws with captive wire clamp,


Terminal/Torque 8 5
fingersafe (5.5 - 9 in•lbs) 8 5
2-ø4.2 Mounting Hole
4 1
ø5
44 14

4 1
(M4 screw hole)
Wire Size Maximum up to 2–#14AWG 42 12
4.2

Electrical Rating 300V, 7A


64

46

16
Compatible Relay RY2S, RY22S A2 A1
14 13
14 13
12 9
Hold-Down Spring SY2S-02F1
2

41 11

12 9
(TOP VIEW)
1.6

Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) 16 18.2 (cannot use ring terminal)
20 29

1. For socket mounting accessories, see page F-29. All dimensions are in mm.
2. For hold-down clip/spring selections, see page F-4.

F-18 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets SY Series: DIN Rail Snap-Mount

SY4S Sockets

28.5 when
SY4S-05 using BAA
30
Style 14-blade, snap-mount/surface mount

0.7
6 18
Terminal
M3 screw with captive wire clamp DIN Rail (BAA) Arrangement
Terminal/Torque M3 Screw
(5.5 - 9 in•lbs) 2-ø4.2 Mounting Hole 8 7 6 5
4 3 2 1
(M4 screw hole)
Wire Size Maximum up to 2–#14AWG

62

45
Electrical Rating 300V, 7A
26
RY4S, RY42S, RU4S, RU42S, RM2S,

4.2
Compatible Relay 4max. 4.8min. 14 13
*RY2KS, (*latching relay) 12 11 10 9
ø3.2min.
(TOP VIEW)
Compatible Timer GT5Y 18.5
3 26 25 5.9max.
SY4S-51F1 for all relays; SY4S-51F3 for
Hold-Down Spring RY2KS only

Hold-Down Clip SFA-101 (top notch), SFA-202 (side


notch) for all relays and timers
F

Sockets
SY4S-05C Fingersafe 32.5 when
using BAA
Style 14-blade, snap-mount/surface mount
DIN Rail (BAA)

30 25
M3 screw with captive wire clamp, 6
Terminal/Torque Terminal
fingersafe (5.5 - 9 in•lbs) M3 Screw Arrangement
Wire Size Maximum up to 2–#14AWG 44
8

34
7

24
6

14
5

2-ø4.2 Mounting Hole 8 7 6 5


4 3 2 1
ø5.5 18 (M4 screw hole) 4 3 2 1
Electrical Rating 300V, 7A 42 32 22 12
4.2

RY4S, RY42S, RM2S, RU4S, RU42S,


46
64

Compatible Relay 26
*RY2KS, (*latching relay)
14 13
Compatible Timer GT5Y A2

14
A1

13 12 11 10 9
2.0

41 31 21 11

SY4S-51F1 for all relays; SY4S-51F3 for 12 11 10 9


(TOP VIEW)
Hold-Down Spring RY2KS only (cannot use ring terminal)
1.6

26 18.2
SFA-101 (top notch), SFA-202 (side 29
Hold-Down Clip notch) for GT5Y timer and relays

All dimensions are in mm.

1. For socket mounting accessories, see page F-29.


2. For hold-down clip/spring selections, see page F-4.

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-19
SM Series: DIN Rail Snap-Mount Sockets

SM2S Sockets

SM2S-05 28.5 when


30 using BAA
Style 8-blade, snap-mount/surface mount

0.7
6 18
M3 screw with captive wire clamp Terminal
Terminal/Torque DIN Rail (BAA) Arrangement
(5.5 - 9 in•lbs) M3 Screw
2-ø4.2 Mounting Hole 8 5

Wire Size Maximum up to 2–#14AWG (M4 screw hole) 4 1

Electrical Rating 300V, 10A

62

45
26
Compatible Relay RU2S, RM2S

4.2
14 13
4max. 4.8min.
Compatible Timer — ø3.2min.
12 9
(TOP VIEW)
18.5
Hold-Down Spring SY4S-51F1
26 25 5.9max.
3

SFA-101 (top notch), SFA-202 (side


F Hold-Down Clip notch)
Sockets

32.5 when
SM2S-05C Fingersafe using BAA
DIN Rail (BAA)

Style 8-blade, snap-mount/surface mount 30


25
6 Terminal
M3 screw with captive wire clamp, M3 Screw
Terminal/Torque Arrangement
fingersafe (5.5 - 9 in•lbs) 8 7 6 5
8 5
44 34 24 14
18 2-ø4.2 Mounting Hole
ø5.5
Wire Size Maximum up to 2–#14AWG 42
4

32
3

22
2

12
1
(M4 screw hole) 4 1
4.2

Electrical Rating 300V, 10A


64

46

Compatible Relay RU2S, RM2S 26


A2 A1 14 13
Compatible Timer — 14 13
12 9
2

41 31 21 11

12 11 10 9
(TOP VIEW)
Hold-Down Spring SY4S-51F1
1.6

26 18.2
SFA-101 (top notch), SFA-202 (side (cannot use ring terminal)
Hold-Down Clip 29
notch)

All dimensions are in mm.

1. For socket mounting accessories, see page F-29.


2. For hold-down clip/spring selections, see page F-4.

F-20 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets SR Series: Panel Mount

SR Series: Panel Mount Sockets

35.5∗ 2-ø4.2 Mounting Holes


38 7.5 11 max. Terminal Arrangement (M4 Tapped Holes)
6.75 22

11.5 min.
1 2 3

0.3

32.5
51.5
4 5 6

32
35
43

43
7 8 9
A B

22 3 6.5
SR3B-51 (Bottom View)
(Tolerance ±0.3)
Style 11-blade, panel mount
Terminal Solder 3.5 ∗ When two or more sockets are
mounted side by side:
Electrical Rating 300V, 10A 35 L = 38 (N – 1) + 35.5
N: No. of sockets mounted
Compatible Relay RR1BA, RR2BA, RR3B
Compatible Timer RTE-B
Hold-Down Spring SR3B-02F1 (for relays only)

Surface
2-ø3.5 Mounting Holes
4.2

Panel
(or M3 Tapped Holes)
6
Terminal Arrangement
F
4 5

Sockets
0
ø29
3 6
38

38
50

ø3
2 7
1 8
SR2P-51
Style 8-pin octal, panel mount
(Bottom View)
Terminal Solder 34 2.5 10 11

Electrical Rating 300V, 10A 2.5

Compatible Relay RR2P


Compatible Timer RTE-P1, GT3 (8-pin), GT5P
Hold-Down Spring SR3P-01F1 (for relay only)
SFA-402 (for GT3 8-pin)
Hold-Down Clip SFA-302 (for GT5P)
Surface

2-ø3.5 Mounting Holes


4.2
Panel

(or M3 Tapped Holes)


6

Terminal Arrangement

5 6 7
SR3P-51
0
ø29

4 8
38

38
50

ø3

3 9

Style 11-pin octal, panel mount 2


1 11
10

Terminal Solder
(Bottom View)
Electrical Rating 300V, 10A 34 2.5 10 11

RR3PA, *RR2KP 2.5


Compatible Relay (*latching relay)
Compatible Timer GT3 (11-pin), RTE-P2
SR3P-01F1 for RR3PA
Hold-Down Spring SR3P-51F3 for RR2KP
SFA-402 (for GT3 11-pin,
Hold-Down Clip RTE-P2)

1. For socket mounting accessories, see page F-29. All dimensions are in mm.
2. For hold-down clip/spring selections, see page F-4.

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-21
SH Series: Panel Mount Sockets
SH Series: Panel Mount Sockets

Panel Thickness: [18 (N–1) + 12.4] +0.5


0
1 to 2 Terminal Arrangement

25.6 +0.2
0
5

25.4
31
9
13 14

0.3
18 3 (Bottom View) N: No. of sockets mounted

5.4 min.∗
SH1B-51 11
Style 5-blade, panel mount 18.7
Terminal Solder 3.5 ∗ 10.4 min. when using hold-down springs
Electrical Rating 300V, 10A 2.4
12.2
Compatible Relay RH1B
Hold-Down Spring SY4S-51F1
SFA-301 (top notch),
Hold-Down Clip SFA-302 (side notch)

F
Sockets

+0.5
Panel Thickness: [27 (N–1) + 21.4] 0
1 to 2
Terminal Arrangement
1 4

+0.2
0
5 8
25.4

25.6
31

9 12
13 14
0.3

SH2B-51 27 3 (Bottom View) N: No. of sockets mounted

5.4 min.∗
11
Style 8-blade, panel mount
18.7
Terminal Solder
∗ 10.4 min. when using hold-down springs
Electrical Rating 300V, 10A 3.5
21.2
Compatible Relay RH2B
SY4S-51F1
Hold-Down Spring SY4S-02F1 for RH2B-4C
SFA-301 (top notch),
Hold-Down Clip SFA-302 (side notch)
All dimensions are in mm.

1. For socket mounting accessories, see page F-29.


2. For hold-down clip/spring selections, see page F-4.

F-22 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets SH Series: Panel Mount

SH Series: Panel Mount Sockets, continued

Panel Thickness: [36 (N–1) + 30.4] +0.5


0
1 to 2
Terminal Arrangement

+0.2
1 2 4

0
5 6 8

25.6
25.4
31
9 10 12
13 14

0.3
36 3 N: No. of sockets mounted
SH3B-51 (Bottom View)

5.4 min.∗
11
Style 11-blade, panel mount
18.7
Terminal Solder
3.5 ∗ 10.4 min. when using hold-down springs
Electrical Rating 300V, 10A
30.2
RH3B, *RH2LB
Compatible Relay (*latching relay)
SY4S-51F1
Hold-Down Spring SY4S-02F1 for RH3B-4C
SFA-301 (top notch),
Hold-Down Clip SFA-302 (side notch)
F

Sockets
Panel Thickness: [45 (N–1) + 39.4] +0.5
0
1 to 2
Terminal Arrangement
1 2 3 4

+0.2
25.6 0
5 6 7 8
25.4
31

9 10 11 12
SH4B-51 13 14
Style 14-blade, panel mount
0.3

45 3 N: No. of sockets mounted


(Bottom View)

5.4 min.∗
Terminal Solder 11
18.7
Electrical Rating 300V, 10A
∗ 10.4 min. when using hold-down springs
Compatible Relay RH4B 3.5

39.2
Hold-Down Spring SY4S-51F1, SY4S-02F1
Hold-Down Clip SFA-301, SFA-302

All dimensions are in mm.

1. For socket mounting accessories, see page F-29.


2. For hold-down clip/spring selections, see page F-4.

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-23
SY Series: Panel Mount Sockets
SY Series: Panel Mount Sockets

Panel Thickness: [18(N–1)+12.4] +0.5


0
1 to 2
Terminal Arrangement

+0.2
1 4

0
25.4
5 8

31

25.6
9 12

SY2S-51 13 14

0.3
18 3 (Bottom View) N: No. of sockets mounted

5.4 min.∗
Style 8-blade, panel mount
11
Terminal Solder 18.7

Electrical Rating 300V, 7A ∗ 10.4 min. when husing hold-down springs


2.4
Compatible Relay RY2S, RY22S 12.2

Hold-Down Spring SY4S-51F1


SFA-301 (top notch),
Hold-Down Clip SFA-302 (side notch)

F
Sockets

Panel Thickness: [27 (N–1) + 21.4] + 0.5


0
1 to 2
Terminal Arrangement
SY4S-51 1 2 3 4

+0.2
0
5 6 7 8
25.4

Style 14-blade, panel mount


31

25.6
9 10 11 12
13 14
Terminal Solder
0.3

27 3 (Bottom View) 5.4 min.∗ N: No. of sockets mounted


Electrical Rating 300V, 7A 11

RY4S, RY42S, RM2S, 18.7


Compatible Relay RY2KS, RU4S, RU2S,
RU42S ∗ 10.4 min. when using hold-down springs
2.4

Compatible Timer GT5Y 21.2

SY4S-51F1 for all


relays except;
Hold-Down Spring SY4S-02F3 for RY2KS
relay
SFA-301 (top notch),
Hold-Down Clip SFA-302 (side notch)
All dimensions are in mm.

1. For socket mounting accessories, see page F-29.


2. For hold-down clip/spring selections, see page F-4.

F-24 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets SH Series: PCB Mount

SH Series: PC Board Mount Sockets

Terminal Arrangement 3-ø2.4 holes 6.8 18 min.

6.95
1 4.4
5

4.7
25.4
31
9
13 14

11.85
0.3
18 3 (Bottom View)
SH1B-62

5.95
11

31 min.∗
Style 5-blade 2-ø2 holes
15
2
Terminal Solder/PCB mount 1.5 (Tolerance ±0.1)
∗ 36 min. when using
Electrical Rating 250V, 10A 12.2 hold-down springs

Compatible Relay RH1B


Hold-Down Spring SY4S-51F1
SFA-301 (top notch),
Hold-Down Clip SFA-302 (side notch)

Sockets
Terminal Arrangement 2.85 21.5 min.
1 4 15.5

5.65
5 8
25.4
10
29

4.7
9 12
SH2B-62 13 14
0.3

Style 8-blade 3 (Bottom View)

29 min.∗ 12.5
21.2

Terminal Solder/PCB mount 11

6.6
15 8-ø2.4 holes
Electrical Rating 300V, 10A
Compatible Relay RH2B 2
(Tolerance ±0.1)
∗ 34 min. when using
Hold-Down Spring SY4S-51F1, SY4S-02F1 hold-down springs

SFA-301 (top notch),


Hold-Down Clip SFA-302 (side notch)

Terminal Arrangement 36 min.


7.35 21.3
1 2 4
5 6 8 10 10
25.4

4.7
31

9 10 12
13 14
0.3

6.65
12.5

36 3 (Bottom View)
SH3B-62 11
6.6
31 min.∗

Style 11-blade 15
11-ø2.4 holes
Terminal Solder/PCB mount 2

Electrical Rating 300V, 10A 30.2 ∗ 36 min. when using (Tolerance ±0.1)
hold-down springs
RH3B, *RH2LB
Compatible Relay (*latching relay)
Hold-Down Spring SY4S-51F1, SY4S-02F1
SFA-301 (top notch),
Hold-Down Clip SFA-302 (side notch)

1. For socket mounting accessories, see page F-29. All dimensions are in mm.
2. For hold-down clip/spring selections, see page F-4.

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-25
SH/SY Series: PCB Mount Sockets
SH Series: PC Board Mount Sockets, continued

Terminal Arrangement 6.85 45 min.


1 2 3 4 31.3

6.65
5 6 7 8

25.4
10 10 10

4.7
31
9 10 11 12
13 14

0.3
45 3 (Bottom View)

12.5
11
SH4B-62

31 min.∗

6.6
15
Style 14-blade 14-ø2.4 holes
2
Terminal Solder/ PCB mount ∗ 36 min. when using
39.2 (Tolerance ±0.1)
hold-down springs
Electrical Rating 300V, 10A
Compatible Relay RH4B
Hold-Down
SY4S-51F1, SH4B-02F1
Springs
SFA-301 (top notch),
Hold-Down Clip SFA-302 (side notch)

F
Sockets

SY Series: PC Board Mount Sockets

4.4 13.6 min.

10.4
Terminal Arrangement
1 4 4.1
5 8
25.4

9
16.8
31

9 12
SY2S-61 13 14
14.2 min.∗

Style 8-blade
0.3

18 3 (Bottom View)
Terminal Solder/PCB mount 11 8-ø2 holes
Electrical Rating 300V, 7A 15
∗ 19.2 min. when using (Tolerance ±0.1)
1.5 hold-down springs
Compatible Relay RY2S, RY22S
12.2
Hold-Down Spring SY4S-51F1
SFA-301 (top notch),
Hold-Down Clip SFA-302 (side notch)

All dimensions are in mm.

1. For socket mounting accessories, see page F-29.


2. For hold-down clip/spring selections, see page F-4.

F-26 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets SY Series: PCB Mount

SY Series: PC Mount Sockets, continued

13.2 13.8 min.


8.8

10.4
Terminal Arrangement 4.4

4.1
1 2 3 4
5 6 7 8

25.4
SY4S-61

9
31

16.8
9 10 1112
Style 14-blade 13 14

14.2 min.∗
0.3
Terminal Solder/PCB mount 27 3 (Bottom View)
11
Electrical Rating 300V, 7A 15-ø2 holes
15

1.4
RY4S, RY42S, RM2S, ∗ 19.2 min. when using (Tolerance ±0.1)
1.5
Compatible Relay *RY2KS, RU4S, RU42S, RU2S hold-down springs
(*latching relay) 21.2

Compatible Timer GT5Y


Hold-Down Spring SY4S-51F1, SY4S-02F1
SFA-301 (top notch; except
Hold-Down Clip GT5Y and RY2KS)
SFA-302 (side notch for all)
F

Sockets
13.2 8.2 min.∗∗
8.8
4.4

4.1
Terminal Arrangement
1 2 3 4 10.4

9
5 6 7 8
16.8

SY4S-62
0.3
29

9 10 1112
Style 14-blade 13 14
1.4

21.2 3 (Bottom View)


Terminal Solder/PCB mount 15-ø2 holes
11
12.2 min.∗

Electrical Rating 250V, 7A 15


(Tolerance ±0.1)
RY4S, RY42S, RU4S,
Compatible Relay RU42S, *RY2KS 1.5 ∗ 17.2 min. when using a hold-down spring.
(*latching relay)
∗∗ 13.2 min. when using a hold-down spring for
the relay with check button.
Compatible Timer GT5Y
SY4S-51F1, SY4S-51F3,
SY4S-51F4, *SY4S-02F1,
Hold-Down Spring *SY4S-02F3
(*when mounting a relay
with check button)

All dimensions are in mm.

1. For socket mounting accessories, see page F-29.


2. For hold-down clip/spring selections, see page F-4.

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-27
Other Sockets Sockets
SR Series: Socket for Panel Mounted Timers

8-M3.5
0.8~5mm
44.6

3.5max. 5.6min.
3 4 5 6 ø3.6min.

30.4
44.6
6.9max.
2 1 8 7

SR6P-M08G
7
Style 8-pin 9.8x3
80.5

Terminal M3.5 screws with captive wire clamp


Electrical Rating 300V, 10A
Wire Size Maximum up to 2-#12AWG
Compatible Timer GT3 (8-pin), RTE-P1, GE1A
Hold-Down Spring SY4S-02F1

F 11-M3.5
45
16.7
Sockets

3.5max. 5.8min.
2 1 11 7 6 ø3.6min.
5

45
34
6.9max.
4 3 8 9 10

SR6P-M11G
30.5 7
Style 11-pin 92 8.5x4

Terminal M3.5 screws with captive wire clamp


Electrical Rating 300V, 10A
Wire Size Maximum up to 2-#12AWG
Compatible Timer GT3 (11-pin), RTE-P2
Hold-Down Spring ------

All dimensions are in mm.

1. For socket mounting accessories, see page F-29.


2. For hold-down clip/spring selections, see page F-4.

F-28 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets Accessories

Accessories

SA-203
SA-203 SA-204

M4 screw
18mm washer
5mm hold-down
spring

Description Appearance Use with Part No. Remarks


IDEC offers a low-profile DIN rail
(BNDN1000). The BNDN1000 is
Aluminum designed to accommodate snap-
mount sockets. Made of durable
DIN Rail All DIN rail sockets BNDN1000 extruded aluminum, the BNDN-1000
(1 meter length) measures 0.413 in height and 1.37
(35mm) in width (DIN standard).
Standard length is 39" (1,000mm).

DIN Rail
DIN rail BNL5 9.1 mm wide.
End Stop
F

Sockets
For use on ends of socket groupings
SA-203
Surface Mount SY2S, SY4S, SR3B, SH1B, when surface mounting.
End Connector SH2B, SH3B, SH4B For use between adjoining sockets
SA-204 when surface mounting.

Surface Mount SY2S, SY4S, SR3B, SH1B, For use between adjoining sockets
SH2B, SH3B, SH4B SA-405 when surface mounting.
Connector

DIN Rail Spacer All DIN rail sockets SA-406

SY4S-51, SH2B-51 SA-402 11.42" length with 10 holes.

Steel Mounting Plates


(for panel mount sockets)
SY4S-51, SH2B-51 SA-403 23.33" length with 21 holes.

RH2B, RM2S, RY4S, RY42S, RH-01


RU4S, RU42S
Relay Holders For diagram, see next page.
RY2S, RH1B RH-03

For use with hold-down springs


Replacement Hold- Horseshoe clip for all (bale wire types).
DIN rail sockets except Y778-011
Down Spring Anchor or DIN rail mount sockets.
SR*P-05(C) 2 pieces included with each socket.

Hold-Down Spring for For SR2P-05, SR2P-05C,


Chair clip for SR*P-05(C) Y703-102
SR*P-05(C) SR3P-05, SR3P-05C

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-29
Instructions Sockets
Instructions

Mounting Snap-Mount Sockets


Snap-mount sockets are designed to mount on the BNDN-1000
Mount mounting rail. The built-in mounting clip eliminates mounting hard-
ware and reduces mounting time by 80%.
To mount see Figure 1. Place the end of the socket (end opposite of
mounting clip against the outer edge of the rail). Press the socket
down firmly until the clip snaps onto the mounting rail. To remove
Figure 1 see Figure 2. Pull out the mounting clip with a screwdriver, and lift
the socket.
Remove For spacing between adjoining sockets, use the SA-406 DIN rail
spacer. Spacers are 0.195" wide. Spacing can be adjusted accord-
ing to the number of spacers added. Spacers snap on and off easily Hold-Down Spring
like snap-mount sockets.
Figure 2 To prevent side-to-side movement, use a BNL-5 end clip at each
end of every socket row.

Mounting Relay Holders

F
Sockets

RH-01 or -03

Mount directly onto panel boards in two alternate


positions: A and B (see Figure 1).

To mount the relay into the holder, hook the bottom


Figure 1 edge of the relay case (coil terminal side) onto the
relay holder (see Figure 2).

Push down until the relay snaps into place.

Figure 2

Mounting Hold-Down Springs


Take the two anchor clips (horseshoe / U-shaped
piece) that come with the socket and insert into
the slits on both sides of the socket. Make sure the
raised notches on the anchor clip face into the
socket.

Plug relay into socket

Insert the open ends of the hold-down spring into


either the first or second hole of the anchor clip.
The relay-spring combination will determine which
hole should be used.

Slide spring over relay.

F-30 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets Dimensions

Dimensions

Surface Mount Sockets (SH2B-02)


IDEC surface mount sockets (SH2B-02) are also designed to mount
individually or collectively on a flat surface without the use of a DIN
rail. Use the mounting screw between adjoining sockets and at the
outer ends of the row of sockets.

Dimension Table
Socket Part No. Dimension A
SH2B-02 1.14"

A A A

1. Drawing is not to scale.

Snap-Mount Sockets
F
Snap-mount sockets are designed to mount individually or collectively

Sockets
without using a rail. Use a SA-405 connector or SA-204 connector
between adjoining sockets (see Figures 1 and 2). Use the SA-203 end
connector at the outer ends of each socket row when using the
SA-204 connector (see Figure 2).

Dimension Table
Socket Part No. Dim. B Dim. C Dim. D
SY2S-05, SY2S-05C 0.669" 0.826" 0.866"
SY4S-05, SY4S-05C 1.024" 1.181" 1.220"
SR3B-05 1.496" 1.693" 1.732"
SH1B-05, SH1B-05C 0.630" 0.787" 0.827"
SH2B-05, SH2B-05C 1.024" 1.181" 1.220"
SH3B-05, SH3B-05C 1.417" 1.575" 1.614"
SH4B-05, SH4B-05C 1.811" 1.969" 2.008"

Using an SA-406 Connector

B C C C C
0.165" Hole
Using SA-203 or SA-204 Connectors or M4 Tapped

D D D

2. Drawings are not to scale.

www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-31
Dimensions Sockets
Dimensions, continued

Collective Panel Mounting


SH and SY series panel mount sockets are designed to mount collec-
tively in panel cut-outs. Insert socket with mounting springs facing the
top and bottom edge of the panel cut-out. Push the socket until the
SY4S-51 mounting spring clips onto the panel. (See Figure 1.)

Dimension Table
Part No. Width Relay
SY4S-51 1.063" RY4S, RY42, RY2KS, RM2S
Figure 1
SH4B-51 1.772" RH4B
SH3B-51 1.418" RH3B, RH2LB
RH2B RY2KS
SH2B-51 1.063" RH2B
RH1B
RM2S SH1B-51 0.709" RH1B
SY2S-51 0.709" RY2S, RY22S

How to Calculate Cutout Length (L)

Cutout L = A (Total Overall Width of Each Socket) – 0.221" (+ 0", – 0.020")

F Example: A = Total Overall Width of Each Socket


Cutout L = A – 0.221" (+ 0", – 0.020")
Sockets

SY2S-51
SY4S-51 SY4S-51 SH1B-51 SY4S-51
SY4S-51 SY2S-51 SH1B-51 SH2B-51
L = [0.709" + 1.063" + 1.063" + 0.709" + 1.063" + 0.709" + 1.063" + 1.063"] – 0.221" = 7.93"

L = 7.93" (+ 0", – 0.020")

Mounting Plate

F-32 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC