For over 130 years, Toshiba has been a world leader in developing
technology to improve the quality of life. Our 50,000 global patents
demonstrate a long, rich history of leading innovation. It might surprise
you to learn about some of the things we’ve invented.
1915 Japan’s first X-ray tube 1990 First helical CT scanner 2002 First 400 ms CT scanner
1954 First digital computer 1993 First real-time CT fluoro 2004 First Quantum Denoising Software
1977 First cardiac ultrasound scanner 1995 First DVD 2007 First dynamic volume CT scanner
1985 First slip-ring CT scanner 1999 First quiet MRI 2009 First 160-row Helical
1986 First laptop computer 1999 First 0.5 mm multidetector CT 2010 First iterative recon technique for 320 Detector Row CT
04)*#"&%*$"-:45&.403103"5*0/.&&54*/5&3/"5*0/"--:3&$0(/*;&%
45"/%"3%4'036"-*5:"/"(&.&/5:45&.
04)*#"&%*$"-:45&.403103"5*0/"461&3"5*0/4.&&545)&
/7*30/.&/5"-"/"(&.&/5:45&.45"/%"3%
"%&'03*'&26*-*0/26*-*0/ &$)/0-0(*&4$0/&!"$5
=04)*#"&%*$"-:45&.403103"5*0/"--3*()543&4&37&%
"3%*0 -"26&0045 910463& 6#53"$5*0/ -6030 CX EDITION
!5&/4*0/"/% 5"35"3&53"%&."3,40'04)*#"&%*$"-
&4*(/"/%41&$*<$"5*0/446#+&$550$)"/(&8*5)065/05*$& :45&.403103"5*0/
0%&-/6.#&3! 128-slice CT SCANNER
3*/5&%*/"1"/
Maximize the potential
of today’s clinical resources
Without With
Conventional Scan 0.5 0.5 0.5 64 slices
Double-Slice Technology Double-Slice Technology
Temporal Bone: Double-slice reconstruction using coneXact technology provides exceptional spatial resolution, as demonstrated
4 in these axial images of the inner ear. 5
Experience the Quantum Advantage
310 micron
t0QUJNBMWPYFMTJ[FGPSBOZSFHJPOPGUIFCPEZ
t7JFXBYJBMJNBHFRVBMJUZJOBMMJNBHJOHQMBOFT
Carotid stent: A stent across the bifurcation of the left common carotid artery is depicted in this 3D image. The curved MPR view shows some in-stent restenosis
6 in the internal carotid artery. The 310 micron spatial resolution provides excellent images that clearly demonstrate the struts of the stent. 7
Cardiac scanning made easy
High performance in image quality and speed must go hand in hand with SURE
CARDIO SCORING* SURE
PLAQUETM*
efficient workflow. The Aquilion /CX has specifically addressed workflow Provides fast and easy evaluation of calcium based on A comprehensive advanced visualization tool to assist
integration to optimize productivity and enhance diagnosis. non-contrasted, ECG-gated data directly from the Aquilion clinicians in evaluating the characteristics inside the
console. blood vessel.
CARDIOTM WITH PHASEXACT*
SURE t$BMDVMBUFT$BTDPSFTVTJOHUIF"HBTUPONFUIPEBOE tVisualize coronary vessel anatomy and disease with ease
phaseXact
the Volume mass method using defined HU ranges
Delivers clear, accurate cardiac images and enhances patient throughput and
workflow by automatically selecting optimum scan parameters. t"SFQPSUBOEUIFSFQSFTFOUBUJWFJNBHFTTIPXJOH t2VBOUJGZQMBRVFCVSEFOBOEDPSPOBSZSFNPEFMJOHOPO
calcium will be automatically generated invasively
t"VUPNBUFE
DMJOJDBMMZWBMJEBUFEQSPUPDPMTQSPWJEFUIFCFTUUFNQPSBMSFTPMVUJPO
regardless of patient heart rate or condition t$IBSBDUFSJ[FMFTJPOTJOUIFWFTTFMXBMMBTFJUIFS
calcified or non-calcified
t"DIJFWFDPOTJTUFOU$BSEJBD$5"XJUIBEBQUJWF
NVMUJTFHNFOUSFDPOTUSVDUJPO
Motion
t%FDSFBTFQBUJFOUTDBOUJNFUISPVHIQSPUPDPMBVUPNBUJPO
t3FEVDFWJFXUJNFBOETUPSBHFTQBDFXJUIQIBTF9BDU
XIJDIBVUPNBUJDBMMZ 0% 20% 40% 60% 80% 100%
SURE SURE
Cardio Scoring for fast volumetric coronary calcium evaluation. Plaque permits both classsification and quantification of coronary
artery plaques.
8 Coronary Artery Bypass Graft (CABG) acquired using SURECardio automated scan. 9
* Option
Low dose imaging without compromise
Thanks to the use of advanced dose reduction techniques, Aquilion /CX CARDIO PROSPECTIVE*
SURE Standard ECG
substantially reduces the patient exposure dose and improves the image Dose Modulation
Reduce the exposure dose during ECG-gated helical scanning by changing
quality by applying sophisticated algorithms to the raw data, both operating the helical pitch according to the heart rate and restricting X-ray exposure to
in three dimensions. the required cardiac phases in synchronization with the ECG signal.
t%FWFMPQFEUPQFSGPSNMPXEPTFDBSEJBD$5"JOBWPMVNFUSJDIFMJDBMTDBO
SURE
BOOST3D TM Cardio Prospective
Without Boost3D With Boost3D t6TFBQVMTFE 0/0''
FYQPTVSFDPOUSPMXJUIIJHIFSIFMJDBMQJUDITFUUJOHT Dose Modulation
Measures the acquired data for increased absorption t1JUDITFMFDUJPOBOEFYQPTVSFXJOEPXBSFDIPTFOBVUPNBUJDBMMZGSPNUIF
(e.g., in the shoulder region) and performs compensation patient’s heart rate
accordingly, resulting in superior image quality and a
further reduction in the patient exposure dose.
ECG GATED
EXPOSURETM 3D
SURE contrast bolus. Ideal for multiple procedures in one session such as:
Measures the size and attenuation of the patient and t$PSPOBSZBSUFSZ$5" &$(HBUFEVTJOH$BSEJBD1JUDI
BOE$5"PGUIFBPSUB
Low mA (non-gated using a standard CTA pitch)
tailors the radiation dose to achieve the required image TABLE SPEED
150 mA
CHANGE
quality. Using an automatic, individualized protocol 120 mA t$PNCJOFUSBVNBBQQMJDBUJPOTTVDIBTBCSBJOTDBOBOEBOFDLTDBOJO
ensures that a uniform level of image quality can be 100 mA
one continuous scan
STANDARD
Standard mA
120 mA
maintained at the lowest possible dose for every patient. 150 mA
200 mA
25 mA
Published Reference dose values are available for review.
10 11
* Option
Maximizing clinical capabilities
SURE SURE
Cardio Scoring* Cardiac Function Analysis* SubtractionTM* SURE
FluoroTM* Colon View* Dental Analysis*
Fast and easy evaluation of calcium based Calculate the various functional parameters, Automated digital subtraction of intra- Real-time reconstruction and display of Automated visualization software for Comprehensive dental MPR software with
on non-contrast ECG-gated data such as ejection fraction, wall motion, cranial vessels from bone fluoroscopic images for faster and safer accurate diagnosis in colon examinations easy-to-use tools for pre-operative planning
cardiac output, etc interventional procedures
12 13
* Option
Aquilion /CX.
Performance you can see
Pediatric CTA showing large Arteriovenous Malformation (AVM), using a Brain CTA with SURE
Subtraction bone removal.
low dose SUREExposure 3D protocol.
Pulmonary artery CTA using SUREStartTM and advanced on console 3D. Artifact free cervical spine CT post myelogram.
14 Aorta CTA rendered using on-console advanced 3D. Pulmonary vein mapping used for pre-ablation planning. 15
Golden standard high performance
t% %BOE%SFBMUJNFEZOBNJDQFSGVTJPOJNBHJOH
* Option
16 17
Continuously advancing
the state-of-the-art
CLINICAL TRIALS
Toshiba is the first in the industry represent nine of the world’s Other clinical trials include iLead, DELIVERING HIGH-QUALITY, COST-EFFECTIVE PATIENT CARE TOSHIBA LEARNING CENTERS
to conduct international, multi- premiere medical education and an international multi-center trial Aquilion /CX provides more ways to help you better manage the cost of
institution clinical studies in the research centers. evaluating Aquilion 64 CT low dose providing healthcare without compromising the quality of physician and
use of multidetector CT as the faCTor64, a randomized, outcomes- lung nodule detection, conducted at: patient services.
primary diagnostic tool for detecting based trial of over 1,000 diabetic Beth Israel Deaconess t.BLFNPSFFGmDJFOUVTFPGMJNJUFESFTPVSDFTXJUInFYJCMFmOBODJOHPQUJPOT
cardiovascular diseases. patients with obstructive coronary Kobe University, Japan t*ODSFBTFVUJMJ[BUJPOXJUIGBTUFSUISPVHIQVUBOEBDDFTTUPBXJEFSSBOHFPG
Validating 64 detector row Coronary artery disease, is also being DKFZ, Germany applications
CT Angiography with cardiac conducted in cooperation with
catheterization, CorE64 (Coronary Intermountain Healthcare. To ensure consistent scanning
Evaluation on 64) participants QUALITY MANAGEMENT and a faster diagnosis with
In 1915 Toshiba developed the first X-ray tube in Japan. Since that Aquilion /CX, Toshiba’s global
time we have continuously pursued product quality, while developing training facilities provide courses
and producing many products with superior safety, durability, flexibility, for clinicians and technologists.
economy, and serviceability. Toshiba’s fundamental principles are based
on respect for people. In addition to strict compliance with the law, our
Canada
Toronto General goal is to provide products and services that improve our customer’s lives,
USA and contribute to society.
Johns Hopkins University
Bayview Medical Center
Beth Israel Deaconess
GLOBAL NETWORK
Brazil
INCOR With a sales network of local corporations and representatives in more
Europe than 120 countries across the globe, we are proud of our record of service
Charite University, Germany
Leiden University, Netherlands and support to the leading medical institutions throughout the world.
Japan
Iwate Medical University
Customer Support & Training
Singapore
Center at the Nasu Headquarters.
Mount Elizabeth
USA
Intermountain Healthcare
18 19