Digital www.omicronenergy.com/cibano500
micro-ohm (µΩ)
meter
Coil and
motor supply of 2.4 kW
Your benefits
www.omicronenergy.com/cibano500
High-voltage live-tank circuit breaker testing
One test setup for all tests - up to 50 % faster Synchronous timing measurement
CIBANO 500 can test all performance-, motion-, as well as During timing tests on high-voltage live-tank circuit
coil and motor-related parameters of high-voltage live-tank breakers, CIBANO 500 synchronously assesses the timing
circuit breakers with the same test setup. The connection of all main contacts, auxiliary contacts, and pre-insertion
to the circuit breaker only needs to be done once. With resistors. It measures the differences between the
the optional CB MC2 modules, this can save up to 50 % of fastest and slowest phase and can detect incorrect
testing time as conventional measuring devices require that mechanical adjustments or wear phenomena of the
wiring is done at least twice. circuit breakers.
CB MC2
CB MC2 CB MC2
transmission
Digital
CB TN3
Variable
coil supply CIBANO 500
Integrated power supply:
Safe and independent operation Common tests
CIBANO 500’s integrated AC/DC power supply lets you
>> Timing
directly operate the circuit breaker (for example, during
commissioning tests). You don’t need to perform any >> Static contact resistance
connections to live DC circuits of the substation battery >> Dynamic contact resistance test
which makes wiring safer and faster. >> Motion/contact travel
The constant output power during all tests guarantees >> Coil/motor current analysis
reproducible test results. >> Undervoltage condition
>> Minimum pick-up
EtherCAT®-communication:
Fast and future-proof testing
By using EtherCAT®-communication, the number of
measuring channels can be extended to any number
needed by very large or specially designed circuit breakers
(for example, large breakers with independent pole
operation).
Your benefits
www.omicronenergy.com/cibano500
High-voltage dead-tank circuit breaker testing
One device for all required electrical tests Integrated power supply:
CIBANO 500’s 3-in-1 approach combines a timing Safe and independent operation
and travel analyzer, a micro-ohm (µΩ) meter, and a CIBANO 500’s integrated AC/DC power supply lets you
coil and motor supply within one device. As a result directly operate the circuit breaker (for example, during
you can perform timing, first trip, contact resistance, commissioning tests). You don’t need to perform any
coil/motor current, and motion tests without any connections to live DC circuits of the substation battery
additional accessories. which makes wiring safer and faster.
The contact resistance tests can be performed with The constant output power during all tests guarantees
an injection of up to 100 A. reproducible test results.
The results of all tests are available as one combined
test report. First-trip test
You only need to transport one device to the test site. This test method measures changes to the main contact
state and trip coil behavior via non-intrusive current clamp
transducers. The method is also known as the First Trip test
because it simulates the first trip of a circuit breaker where
the contacts and mechanism have not been actuated
for some time and are suddenly required to carry out a
protective tripping. It may reveal that the breaker does not
operate at all; only partially; or after a delay, as a result of
ineffective or degraded lubricant, surface contamination,
corrosion of mechanical elements, etc.
CB TN3
Variable
CIBANO 500
transmission
Digital
coil supply
CT demagnetization
The optional CT demagnetization function demagnetizes Common tests
the integrated current transformers of the circuit breaker
>> Timing
via the primary side. This makes sure that no residual
>> First trip
magnetism affects the correct function of the CTs.
>> Static contact resistance
Dynamic contact resistance test >> Motion/contact travel
During this test, CIBANO 500 and the optional CB MC2 >> Dynamic contact resistance test
modules, record the contact resistance value during circuit >> Coil/motor current analysis
breaker operation and deliver information about wear-
>> Undervoltage condition
related problems with main and arcing contacts.
>> Minimum pick-up
Both sides grounded timing tests
Timing tests on high-voltage dead-tank circuit breakers
can be performed with both sides grounded. This results
in increased safety levels for operating personnel.
Your benefits
www.omicronenergy.com/cibano500
Circuit breaker testing on gas-insulated switchgear (GIS)
One test setup for all tests Timing tests with Current Sensor Measurement
CIBANO 500 can test all performance-, motion-, as well as and both sides grounded
coil and motor-related parameters of GIS circuit breakers When a timing measurement on a GIS breaker must be
with the same test setup. The connection to the circuit performed with both sides grounded, CIBANO 500 offers
breaker only needs to be done once. With the optional the possibility to use the new current sensor measurement
CB MC2 modules, this can save a lot of testing time, as method (CSM).
conventional measuring devices require this wiring to be The CSM easily measures the operating times of the circuit
done at least twice. breaker with an inductive sensor laid round the ground
connection of the grounding switch. Nothing else needs to
be modified.
It is a highly flexible measuring method, because the
adjustable measuring sensor can be easily installed on a
multitude of different grounding switches and performs
precise timing measurements.
CB MC2
Digital
CB TN3 transmission
CIBANO 500
CT demagnetization
The CT demagnetization function demagnetizes the Common tests
integrated current transformers of the circuit breaker
>> Timing
via the primary side. This makes sure that no residual
magnetism affects the correct function of the CTs. >> Static contact resistance
>> Motion/contact travel
>> Dynamic contact resistance test
>> Coil/motor current analysis
>> Undervoltage condition
>> Minimum pick-up
CB MC2
CB MC2
Your benefits
www.omicronenergy.com/cibano500
CIBANO 500 measuring accessories
rebound
total
velocity travel
open
position
0
Performance values tested with CIBANO 500 and CB TN3
12
Input / output module IOB1 EtherCAT® Hub EHB1
The IOB1 is an EtherCAT®-compliant device and offers six The EHB1 allows the connection of more than four
additional input and six additional output channels for EtherCAT®-compliant devices with CIBANO 500.
CIBANO 500. Depending on the necessary number of EtherCAT®
What does it do? connections any number of hubs can be connected in
IOB1 is digitally controlled by CIBANO 500 via EtherCAT®- series. The EHB1 consists of one input and four outputs.
communication. With its six input channels it can What does it do?
synchronously read the data of auxiliary contacts and send It enables the connection of up to 4 additional
them to CIBANO 500. With its six output channels it can EtherCAT®-compliant devices with CIBANO 500.
synchronously control the trip or close coils or the motors of When is it needed?
a circuit breaker. When testing large circuit breakers where additional
When is it needed? EtherCAT®-sockets are needed.
For an analysis of circuit breakers where the timing of
more than six auxiliary contacts must be measured
simultaneously.
For timing measurements of larger circuit breakers
when more than one opening and closing coil or breaker
motor must be controlled simultaneously.
* EtherCAT® (Ethernet for Control Automation Technology) is an Ethernet-based real-time fieldbus system.
EtherCAT® communication is fast (cycle times ≤ 100 µs) and ideal for synchronized transmission of digital data.
13
Primary Test Manager TM – Guided testing with easy data management an
Easy management of location, asset and test data due to a structured database, With its flexible and transparent confi
implemented search and filter functions and automatic data synchronization. PTM supports you in the best pos sible
14
and automatic result assessment
configuration (hardware and test parameters), For a comprehensive analysis, PTM offers automatic result assessment
sible way during the execution of diagnostic tests. as well as customized reporting.
15
Technical specifications
CIBANO 500
Commands for motor supply Auxiliary input type Toggling with potential-free (dry)
contacts or voltages (wet)
Current per channel5 Duty cycle up to 300 V DC
24 Aeff AC or DC continuous Maximum sample rate 40 kHz
40 Aeff AC or DC 20 s on Minimum resolution 25 μs
80 s off
55 A DC 10 s on
190 s off Mains supply
16
Interfaces PC Requirements (* recommended)
Mechanical data
Equipment reliability
1
Maximum power rating cannot be exceeded. Maximum voltage and current cannot be supplied at the same time
2
From 2 000 m to 5 000 m altitude CAT III compliance only with half voltage
3
Means “typical accuracy”; at typical temperatures of 23 °C, 98 % of all units have an accuracy which is greater than specified
4
From 2 000 m to 5 000 m altitude only CAT II compliance or CAT III compliance with half voltage
5
Valid while using one channel. Thermal derating when 2 or 3 channels are used in parallel
EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
17
Technical specifications
CB MC2 CB TN3
Channels 2 Output
Current 0 ... 100 A DC Channels3 3
Voltage 5 ... 30 V DC
Channels 3
Pre-insertion resistance (PIR) measurement Range 50 mA
Accuracy2 0.1 % rd + 20 µA
Range 0 ... 10 kΩ
Maximum sample rate 40 kHz
Accuracy (< 500 Ω)
2
0.5 % rd + 10 mΩ
Accuracy ( 500 Ω ... 10 kΩ)
2
3 % rd
Digital interface
1
Valid for test currents ≥10 A
2
Means “typical accuracy”; at typical temperatures of 23 °C, 98 % of all units have an accuracy which is greater than specified
3
3 channels of CB TN3 can be used at a time. They can be freely configured as digital or analog channels
4
Valid while using one channel. Thermal derating when 2 or 3 channels are used in parallel
18
IOB1 EHB1
Channels 6
Auxiliary input type Toggling with potential-free (dry)
contacts or voltages (wet)
up to 300 V DC
Maximum sample rate 40 kHz
Minimum resolution 25 μs
Mechanical data
19
Ordering information
CIBANO 500 Standard Package Package for standard tests on MV and HV CBs. No VE000900
including cables and accessories additional measuring accessories. Rewiring between tests is
necessary.
CIBANO 500 Advanced Package Package for enhanced testing of MV and HV CBs. Comes VE000901
including cables and accessories with three additional CB MC2 modules. No rewiring
necessary between the tests.
CIBANO 500 Dead Tank Package Specially adapted package for testing of MV and HV VE000902
including cables and accessories dead-tank design CBs. It comes with an additional CB TN3
module and one digital rotary sensor.
EtherCAT® Hardware Upgrade Option Hardware module with 4 EtherCAT® lead outs which can VEHO0900
including mounting accessories additionally be mounted into the external module slot of
CIBANO 500
Auxiliary Module Hardware Hardware module with 1 EtherCAT® lead out and 3 VEHO0903
Upgrade Option including mounting measuring inputs for auxiliary contacts. It can additionally
accessories be mounted into the external module slot of CIBANO 500.
20
CIBANO 500 Upgrade Options
EHB1 Upgrade Option External module offering 4 additional EtherCAT® output VEHZ0932
including cables and accessories connections for tests of large circuit breakers where several
EtherCAT® accessories (CB MC2, CB TN3, IOB1) are needed.
CIBANO 500 Standard to Upgrade option for the Standard Package VEHZ0904
Advanced Package Upgrade Option to the Advanced Package.
CIBANO 500 Dead-Tank to Upgrade option for the Dead-Tank Package VEHO0909
Advanced Package Upgrade Option to the Advanced Package.
CB MC2 Upgrade Option Upgrade option for all CIBANO 500 Packages. It comes with VEHZ0900
including cables and accessories one CB MC2 module and facilitates measurements of large
HV breakers.
Motion Linear Basic Upgrade option for all CIBANO 500 Packages. It comes VEHZ0902
Upgrade Option with one digital linear transducer allowing linear motion
including CB TN3, cables and measurements to be performed on CBs with ganged pole
accessories operation.
Motion Rotary Basic Upgrade option for all CIBANO 500 Packages. It comes VEHZ0901
Upgrade Option with one digital rotary transducer allowing rotary motion
including CB TN3, cables and measurements to be performed on CBs with ganged pole
accessories operation.
Motion Linear Standard Upgrade option for all CIBANO 500 Packages. It comes VEHZ0905
Upgrade Option with 3 digital linear transducers allowing linear motion
including CB TN3, cables and measurements to be performed on CBs with independent
accessories pole operation.
Motion Rotary Standard Upgrade option for all CIBANO 500 Packages. It comes VEHZ0906
Upgrade Option with 3 digital rotary transducers allowing rotary motion
including CB TN3, cables and measurements to be performed on CBs with independent
accessories pole operation.
CSM Upgrade Option Upgrade option for CIBANO 500 Advanced Package. It VEHZ0970
including current sensors and cables comes with three current sensors (Rogowski coil) and allows
both-sides grounded timing measurements on GIS CBs.
VTM Upgrade Option Upgrade option for all CIBANO 500 Packages. Used for VESM0915
including short connection cables voltage-based timing measurements on CBs while they are
in service.
First Trip Upgrade Option Upgrade option for all CIBANO 500 Packages. Used for VEHZ0976
including four current clamps performing first trip measurements.
SAA2 safety accessory Cascadable safety accessory (up to six signal lamps) to –*
mark testing area, including emergency button and
optional audible signal
21
CIBANO 500 Main Use Cases
Rotary Basic
Linear Basic
Hardware
Standard
Auxiliary
Package
CB MC2
Module
Motion
Motion
EHB1
IOB1
Medium-voltage circuit breakers Upgrade Options
Timing tests
>> Three main contacts ■
>> Three additional auxiliary contacts ■ ■
>> More than three additional auxiliary contacts ■ ■ □ ■
Motion Rotary
Motion Linear
Rotary Basic
Linear Basic
Advanced
Standard
Standard
Package
CB MC2
Motion
Motion
EHB1
IOB1
High-voltage live-tank circuit breakers Upgrade Options
Timing tests
>> Six main contacts, ganged pole operation ■
>> Three auxiliary contacts, ganged pole operation ■
>> Overlapping trip/close commands ■ □ ■
>> Three auxiliary contacts, independent pole operation ■ □ ■
>> More than three auxiliary contacts ■ □ ■
>> Additional main contacts ■ □ ■
Static contact resistance test
>> Six main contacts ■
>> Additional main contacts ■ □ ■
Motion analysis
>> Linear motion test, ganged pole operation ■ □ ■
>> Linear motion test, independent pole operation ■ □ ■
>> Rotary motion test, ganged pole operation ■ □ ■
>> Rotary motion test, independent pole operation ■ □ ■
22
to Advanced
Linear Basic
Dead-Tank
Dead-Tank
Package
Motion
EHB1
IOB1
High-voltage dead-tank circuit breakers Upgrade Options
Timing tests
>> Three main contacts ■
>> Three auxiliary contacts ■
>> More than three auxiliary contacts ■ □ ■
Motion analysis
>> Rotary motion test ■
>> Linear motion test ■ □ ■
Rotary Basic
Linear Basic
Advanced
Package
Motion
Motion
EHB1
IOB1
CSM
Gas-insulated switchgear (GIS) Upgrade Options
Timing tests
>> Three main contacts, single-side grounded ■
>> Three main contacts, both-sides grounded ■ ■
>> Three auxiliary contacts ■
>> More than three auxiliary contacts ■ □ ■
Motion analysis
>> Linear motion test ■ □ ■
>> Rotary motion test ■ □ ■
Tony Porrelli
Application Specialist
24
Wenyu Guo
OMICRON Academy
Thomas Bischof
Technical Support
25
OMICRON – Who we are
Our values
We acknowledge our social, ecological and corporate Over 750 employees from 45 different countries shape our
responsibility, and are committed to ensuring sustainable extremely diverse corporate culture today. Flat hierarchies
development and business practices. The majority of and a high degree of individual responsibility create a
development and production work takes place at our motivational work environment in which our employees
premises in Austria. Highly specialized suppliers from the can realize their full potential. Actively practiced corporate
region and first-class components guarantee the reliability values such as respect and trust lead to our unique
and durability of every OMICRON device. company spirit.
26
Customers in over Over 700 employees across
100 countries worldwide 22 offices worldwide
27
For more information, additional literature, and detailed contact
information of our worldwide offices please visit our website.