Mud pump cavitation: Routine


inspections, maintenance can
prevent ‘silent killer’ from reducing
rig efficiency, equipment reliability
With pumps being run at max horsepower at today’s well sites, best practices
can help contractors to avoid premature damage, extend consumables life

BY ADAM AVEY, GARDNER DENVER

CAVITATION IS AN UNDESIR ABLE will see the equipment shaking and hear the a sealing surface. These unexpected failures
condition that causes a reduction in pump pump “knocking,” which typically sounds are expensive and lead to a minimum of
efficiency and excessive wear/damage to like marbles and stones being thrown around eight hours of rig downtime for module
pump components. Factors that can contrib- inside the equipment. However, the process replacement.
ute to cavitation, such as fluid velocity and of cavitation starts long before audible signs
pressure, can sometimes be attributed to an reveal themselves – hence the name, “the PREVENTING CAVITATION
inadequate mud system design and/or the silent killer.” Stopping cavitation before it starts is a
diminishing performance of the mud pump’s Mild cavitation begins to occur when matter of routine inspection and mainte-
feed system. the mud pump is “starved” for fluid. While nance. For starters, install and tune high-
Other factors contributing to cavitation the pump itself may not be making noise, speed pressure sensors on the mud suction
include: damage is still being done to the internal line to alarm if the pressure falls below
• Improper sizing of charge pump; components of the fluid end. Mild cavita- 30 psi. Accelerometers can also be used to
• Improper maintenance of charge pump tion damages the module, piston and valve detect slight changes in module performance
impellers – worn impellers cause a reduction assembly. These hidden and intense shock and can be a good early warning system
of fluid pressure; waves generated by cavitation travel directly for cavitation prevention. Routinely conduct
• Dirty or clogged charge pump feed and from the fluid end to the pump’s power end, visual inspections on the pump. While the
discharge lines; causing premature damage (vibration) to knocking may not be loud, if inspections are
• Improper size of plumbing from charge the crosshead slides, thus passing onto the conducted on a regular basis, a field techni-
pump to mud pump; shaft, bull gear and into the main bearings. cian will be able to detect moderate vibra-
• Elevation changes and excessive elbows If not corrected, the vibrations caused by tions or knocking sounds. Finally, maintain
in plumbing from mud tank to mud pump; cavitation will work their way directly to the gear end of the pump and check oil on a
and these critical power end components, caus- regular basis.
• Lack of/or inadequate suction and dis- ing premature failure, expensive downtime Gardner Denver offers Pump University
charge dampening. and repair costs. (PumpU), a mobile classroom that travels to
Cavitation is an avoidable issue, but with- As referenced in Figures 1 and 2, the customers’ facilities and/or drilling rigs and
out proper inspection of the feed system it process of cavitation causes numerous pits trains rig crews on how to properly maintain
can accelerate the wear of fluid end parts. Tis to form on the module’s internal surface. pumping equipment. Participants in the
can lead to expensive maintenance issues and Typically, cavitation pits result in a stress program have found that their improved
a potentially catastrophic failure. concentration that results in a reduced maintenance skills have extended the life
fatigue life of the module. Washouts are one of fluid end expendables on their sites, in
MILD VS SEVERE CAVITATION of the leading causes of module failure and addition to lowering repair costs, decreasing
When a mud pump has entered full cavita- take place when the high-pressure fluid cuts production costs and reducing workplace
tion, rig crews and field service technicians through the module’s surface and damages hazards.

REPRINTED FROM THE SEPTEMBER/OCTOBER 2018 ISSUE OF DRILLING CONTRACTOR. © DRILLING CONTRACTOR. ALL RIGHTS RESERVED. PRINTED IN THE USA.
D R I L L I N G R I G S , E Q U I P M E N T A N D A U T O M AT I O N

FIGURES 1 (LEFT) AND 2: Long-term, severe cavitation can cause surface pitting on a module crossbore and reduce the module’s fatigue life. Over
time, cavitation can lead to expensive maintenance issues and a potentially catastrophic failure.

RESULTS OF CAVITATION formance. Consumables life has been extend- The best way to prevent pump cavitation
At the onset of cavitation, there will be ed significantly, and module washes have is to check the system’s feed lines and equip-
reduced life in expendables and gradual wear been reduced by nearly 85%. This improved ment daily for any signs of abnormal noise or
on the modules and power end. Severe cavi- performance has drastically reduced rig vibrations. Although it’s impractical to flush
tation will drastically decrease module life downtime and has increased the operational system piping during drilling operations,
and will eventually lead to catastrophic pump efficiency and customer satisfaction for the strainer screens should be checked daily to
failure, causing unwanted and costly down- drilling contractor. remove any debris or other flow restrictions.
time. In addition, failure of the drilling pump Additionally pre-charge (centrifugal) pumps
can also cause damage to the suction and THE IMPACT OF TODAY’S DRILLING should be inspected regularly to ensure out-
discharge piping. RIGS put flow and pressure is adequate. Following
While pump age does not affect its sus- these simple steps will allow you to achieve
CAVITATION IN THE FIELD ceptibility to cavitation, the rig’s age can. maximum performance from your pumping
A leading North American drilling con- Oftentimes, a rig’s mud systems aren’t equipment and reduce unplanned equipment
tractor encountered chronic mud system equipped for the way pumps are run today – outages. DC
issues on multiple rigs. The company expe- at maximum horsepower.
rienced more than 25 premature module
washes in one year and a major power-end
failure. Gardner Denver’s engineering team
was called and spent time on the contractor’s When a mud pump has entered full
rigs observing the pumps during operation

cavitation, rig crews and field service


and surveying the mud system’s design and
configuration.
The team discovered that the suction sys-

technicians will see the equipment shaking


tems were undersized, feed lines were too
small and there was no dampening on the
suction side of the pump. There were also

and hear the pump ‘knocking’... However,


issues with the feed line maintenance – lines
weren’t cleaned out on a regular basis and
solids from the fluid had formed a thick cake

the process of cavitation starts long before


on the bottom of the pipe, further reducing
its diameter. The engineering team recom-
mended increasing the diameter of the feed

audible signs reveal themselves – hence the


lines and routine cleanings to improve flow
and reduce the risk of cavitation.
Following the implementation of these

name ‘the silent killer.’


recommendations, the customer’s drilling
pumps had significant improvements in per-