Cable Reels ◆ Conductor Bar ◆ Festoon ◆ Pendants ◆ Drives ◆ Slip Rings


Solutions From A Single Source

TM
Safe-Lec 2
V-Contact Conductor Bar

New V-Contact bar for the


Electrification of:

● Cranes
● Monorails
● Automated Storage and
Retrieval Systems
www.insul-8.com

The four conductor V-Contact system (pictured above) requires four collectors.
Only one collector is shown above in order to reveal the direct, precision contact of the
collector shoe with the V-Contact Bar. Note that the bar is guiding the shoe, not the cover.
8 GREAT REASONS
◆ BAR GUIDES THE COLLECTOR SHOE



NO LIVE PARTS EXPOSED
Safe-Lec 2
REDUCED CHANCE OF ACCIDENTAL CONTACT
IP2 CERTIFIED
1 SINGLE BOLT 4-POLE HANGER 2 SLOTTED BRACKETS

STEP 1 STEP 2 STEP 3

• It’s a “snap” to install


• Multiple runs can be installed smoothly
and effortlessly • Hanger support brackets feature slide-in slots
• Reduce crane downtime • No more hassles with holes that don’t line up
• Hangers also available in single-pole, • Accurate alignment every time
double-pole and 3-pole versions

5 VERSATILE COVER 6 ONE PIECE JOINT COVER

• Natural “peak” shape sheds water • Easy “snap-on” fit


• Dust will not accumulate as it does on a more • Provides total protection of joint
horizontal surface
• One cover can hold 60, 100, 125, 160, 200, 250, • No exposed/live parts to contact
315 and 400 amp bar
• One common spare part

I NSUL-8 SAFE-LEC 2
1
TO BUY INSUL-8
V-Contact Bar
3 SI AND DI COLLECTORS 4 FEWER EXPANSION ASSEMBLIES

• Simple and safe to connect To compensate for changes in system length due
TYPE SI: Integral cable is protected, no tail to temperature changes, it is necessary over cer-
TYPE DI: All cable is fully enclosed, no tail tain system lengths to include expansion assem-
blies at specific intervals to absorb these temper-
• Robust design for maximum life ature variances. Failure to do so may result in
• High pivot hinge point in collector head allows buckling of bars and possible derailment of the
full articulation without unnecessary pull on collectors.
connection cable
• Safe-Lec 2 systems can run nearly 500 feet
• Long wearing shoe reduces costs (150m) without an expansion assembly.

• Fewer expansion assembies to purchase and


install
• Save on installation labor hours and material
costs
• System is less complicated to install

7 LONGER BAR LENGTHS 8 BOLTED JOINTS


Safe-Lec 2: Available in 15-foot lengths (4.5 m) • Eliminate bar separation common with pin
Other Bar: Available in 10-foot lengths joint systems
• Save money - fewer joints to purchase • Increased safety and system efficency
• Save time - fewer labor hours to install • Superior electrical contact
• Reduce crane downtime associated with
installation

MANY
OTHER
OPTIONS





Heater Wire
Stainless Steel Hardware
Pick Up Guides
Transfer Caps
Higher Temperature Resistant Covers
UL fi
I NSUL-8 SAFE-LEC 2
Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified. 2
TABLE OF CONTENTS

System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

System Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Galvanized Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8

Copper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10

Aluminum / Stainless Steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12

Components Common to All Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-16


Multi-pole Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Anchor Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Single-pole Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Bracket Spacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Web Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Flange Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Beam Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

50 Amp Collector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17-18


Collector Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Ground Collector w/Deflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Shoe and Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Ground Shoe and Holder w/Deflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Collector Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

100 Amp Collector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19-20


Collector Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Ground Collector w/Deflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Shoe and Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Ground Shoe and Holder w/Deflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Collector Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

250 Amp Collector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20


Collector Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Shoe and Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Collector Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Other Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21-22


Transfer Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Pickup Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Joint Compound . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Heater Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

IINSUL
NSUL-8
-8 SAFE-LEC
SAFE-LEC 22
21
3 Specifications
Specificationsmay
maychange
changewithout
withoutnotice.
notice. All
Allproducts
productsF.O.B.
F.O.B.Omaha,
Omaha,NE
NEor
orHarlan,
Harlan,IA
IAunless
unlessotherwise
otherwisespecified.
specified.
SYSTEM OVERVIEW

TYPICAL 3-PHASE RUNWAY


Minimum Single or multi- Insulated
Conductor conductor hangers Hangers
Spacing 43mm (1.7") 60mm (2.36")

75M (246') Max. 36.5M (120') Max Aluminum Bars


All Bars 70M (230') Max Steel Bars For 1108F Temperature Change
Unless Otherwise 49M (160') Max Copper Bars
Specified

.75M (29.5") Max. 450mm (18")


Recommended 150mm (6")
Minimum Min. to 150mm (6")
150mm (6") Expansion Minimum
Anchor Point Sect. Powerfeed
Anchor Point

Hanger 1.5M (59") Recommended


Hanger Spacing Vertical Entry Powerfeed
Joint
End Cover For Curves Expansion Section Conductor Section End Cover
For Lateral Entry 4.5M (14'-9") 4.5M (14'-9")
1.125M (44.3")
NOTE: Maximum Length Without Expansions:
150M (492') Use Anchor Clamp at Center For greater than 1108F temperature change, consult Insul-8.

FOR SYSTEMS OF 600 VOLTS OR LESS


Conductor Bar Galvanized Steel Copper Aluminum/S.S.
(pg. 7-8) (pg. 9-10) (pg. 11-12)
Maximum Voltage 600 600 600 600 600 600 600 600
Amperage 60 100 125 160 250 400 200 315
Resistance R (for DC) 0.003584 0.002867 0.001933 0.000342 0.000274 0.000184 0.000301 0.000261
at 208C in V/M
Impedance Z (for AC) 0.003604 0.002891 0.001968 0.000364 0.000300 0.000221 0.000325 0.000288
at 208C in V/M
Expansion sections not
required for runs less than: 150M 150M 150M 150M 150M 150M 150M 150M
Minimum bending radius 1.5M 1.5M 1.5M 1.5M 1.5M 1.5M 1.5M 1.5M
(horizontal only)
Accurate choice of conductors can only be made when all of the following are known:
The type of current: single or three-phase AC or continuous (DC)
The maximum voltage and current
The ambient temperature
Environment (dusty, coastal, humid, acidic...)

I NSUL-8 SAFE-LEC 2
Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified. 4
SYSTEM SELECTION

SELECTING A SYSTEM IS SIMPLE


To select the proper Safe-Lec 2 V-contact bar system, simply answer the following questions.
Return via fax and we ll provide a quote and qualified customer support.

1 Type of system (runway, bridge, monorail, other) __________________________________________


2 Length of system _______
3 Number of conductors _______
4 Number of vehicles (cranes, etc.) _______
5 Voltage _______ AC _______ DC _______ Phase _______ Cycle _______
6 Amperage requirement of each vehicle _______ (see pg. 6)
7 Total ampacity required _______ (see pg. 6)
8 Environment: Indoor ❑ Outdoor ❑ Both ❑
9 Ambient temperature: (if other than -108F to +1008F) _______ to _______
10 Atmosphere: Dry ❑ Wet ❑ ❑ Dirty ❑ Corrosive ❑ Nuclear ❑
Dusty Other________
11 Bracket required? No ❑ Web, short ❑ Web, long ❑ Flange ❑
12 Do you want brackets supplied? Yes ❑ No ❑
Special Concerns __________________________________________________________________
________________________________________________________________________________
Icing problems? Insul-8 offers heated Safe-Lec 2 systems. See page 22.

PICK YOUR SYSTEM


The following components make up standard conductor bar systems used on cranes, monorails, convey-
ors, and other mobile electrification applications.

✔ Conductor Bar: Choose amperage capacity required


✔ Joints: Order one less than total number of conductor bar, per run
✔ Joint Covers: Remember: Powerfeeds take the place of a joint cover, except for the end powerfeed
✔ Hanger Clamps: Attach the bar to brackets (See pages. 13-14)
✔ Brackets: Support mechanisms that attach to crane rail (See pages15-16)

✔ Powerfeed: Attaches to incoming power

✔ End Cover: Provides protection at each end of a run. 2 per run required.
✔ Collector: Conducts the power from the electrified bar to the motors that are used to
power the crane, hoist, etc.

Note: Expansion Sections are required to compensate for thermal expansion.


Safe-Lec 2 Systems can run for 150m (492 feet) without an expansion section.

I NSUL-8 SAFE-LEC 2
5 Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified.
TECHNICAL DATA

VOLTAGE DROP I NFORMATION


Proper selection of conductor and covers for Voltage Drop: The arithmetical difference between the
Insul-8 Safe-Lec 2TM V-contact conductor systems is simple, voltages at the feed point and the load at the extreme
requiring only the ampacity, voltage and ambient condi- end. It is usually expressed as a percentage of the sup-
tions. ply voltage and can be calculated as shown below.
The method of determining the rating for cranes and Voltage drop increases in direct proportion to the length
hoists is completely outlined in NEC 610-14(e). Further of the conductors. The CMAA Specifications for Electric
references to the Code are made where applicable. Overhead Traveling Cranes (Sec. 5.13) limits total volt-
age drops to 3% on runways and 2% on bridge conduc-
For a single crane, simply use the nameplate full tors. Since powerfeeds are usually located at the mid-
load ampere rating of the largest motor or group point of a system, the effective length is the distance
of motors for any one function plus half the rating from powerfeed to the end of the runway. On longer sys-
of the next largest motor or motor groups. tems it may be necessary to provide additional feed-
points.

Voltage drop calculation = DU


(according to the following formula):
For multiple cranes, use the same method for 3-phase AC DU = 3 x I x D x Z
each crane, add the results and multiply by Single-phase AC DU = 2 x I x D x Z
the demand factor shown in table 610-14(e) Continuous current (DC) DU = 2 x I x D x R
NEC Handbook. Examples:
Where:
DU = Voltage drop in volts
Un = Nominal voltage
I = Maximum current in amps
D = Distance between the feed and
pick-up points in meters
R = Resistence of conductor in
ohms per meter (see page 4)
Z = Impedance of conductor in
ohms per meter (see page 4)

FORMULA
Note: The value of D will vary dependent upon whether a
line is fed at one or several points. (See diagrams below)

Feed point at 1/6


End feed from ea. end
D=L D = L/6

Center feed Three feed points at L/2


D = L/2 and L/10 from ea. end
D = L/10
Feed point at ea. end
D = L/4 U% = DU x 100 [%]
Un

Note: When calculating DU, do not forget to account for the


effects of temperature caused by:
heating of the conductor in relation to the duty cycle, and a
rise in ambient temperature above 458C (1138F)

I NSUL-8 SAFE-LEC 2
Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified. 6
GALVANIZED STEEL SYSTEMS

CONDUCTOR BAR
GALVANIZED STEEL
INSULATED CONDUCTOR BAR 60 AMP 100 AMP 125 AMP
LENGTH: 4.5 METERS (14' 9") INSULATED CONDUCTOR BAR Part No. Part No. Part No.

Standard Phase Cover (Orange) 310001 310101 310201


Standard Ground Cover (Green) 310002 310102 310202
26.2mm Medium Heat Cover (Red) 310003 310103 310203
(1.03")
Weight (kg) 2.410 2.860 3.890
Weight (lb) 5.314 6.306 8.597
22.3mm
(0.88")

INSULATED EXPANSION SECTION


Standard Phase Cover (Orange) 310007 310107 310207
Standard Ground Cover (Green) 310008 310108 310208
Medium Heat Cover (Red) 310009 310109 310209
Weight (kg) 3.540 3.970 5.030
Weight (lb) 7.806 8.754 11.091

STEEL JOINT ISOLATION SECTION


13.6mm

Standard Phase Cover (Orange) 310025 310125 310225


(0.54”)

Description Part No.


Steel Joint 310872 Standard Ground Cover (Green) 310026 310126 310226
Weight: 0.410kg (0.904lb) .97"
) Medium Heat Cover (Red) 310027 310127 310227
m (1
23 50m
(0. mm Weight (kg) 2.710 3.160 4.190
88
") Weight (lb) 5.976 6.968 9.239

INSULATED EXPANSION SECTION


LENGTH: 4.5 METERS (14' 9")

33mm + 2 33mm +2

(2.13")
54mm
(1.3") (1.3")

ISOLATION SECTION
LENGTH: 4.5 METERS (14' 9")
For use in indoor, dry, clean
conditions only.
4500mm
(14’8")
750mm (29.8") 750mm (29.5")

108mm
(4.25")

Consult Insul-8 for other environments

I NSUL-8 SAFE-LEC 2
7 Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified.
GALVANIZED STEEL SYSTEMS

SYSTEM COMPONENTS

ISOLATION SPLICE JOINT COVER


ISO Splice Part No. Joint Cover Part No.
Steel 310972 Standard Phase 310850
Weight: 0.03 kg 0.07 lbs Standard Ground 310851
Med. Heat 310855
Weight: 0.027kg (0.060lb)

31mm 121.4 mm
(1.22") (4.78")

(2 mm
")
66
.6

(1.69")
43mm
18.4 mm
(0.72 )

22.2mm
(.76")

JOINT POWERFEED POWERFEED and COVER


60 Amp. Part No. Up to 250 Amp Part No.
Standard 310034 Standard 310910
Medium Heat 310066 Medium Heat 310913
Weight: 0.027kg (0.060lb) Weight: 0.179kg (0.395lb)

40 mm 230 mm
(1.57") (9.06")
31 mm 121.4 mm
(1.22") (4.78")
108 mm
(4.25")
43 mm
(1.69")

END POWERFEED END COVER


Up to 100 Amp Part No. End Cover Part No.
End Powerfeed 310911 Steel/Copper 310892
Weight: 0.037kg (0.082lb) Weight: 0.020kg (0.044lb)

113mm 68mm
(4.45") (2.68")

I NSUL-8 SAFE-LEC 2
Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified. 8
COPPER SYSTEMS

CONDUCTOR BAR
COPPER
INSULATED 160 AMP 250 AMP 400 AMP
CONDUCTOR BAR INSULATED CONDUCTOR BAR Part No. Part No. Part No.
LENGTH: 4.5 METERS (14’ 9")
Standard Phase Cover (Orange) 310301 310401 310501
Standard Ground Cover (Green) 310302 310402 310502
Medium Heat Cover (Red) 310303 310403 310503
26.2 mm (1.03")
Weight (kg) 2.670 3.120 4.380
Weight (lb) 5.887 6.880 9.658
22.3 mm
(0.88")

INSULATED EXPANSION SECTION


Standard Phase Cover (Orange) 310307 310407 310507
Standard Ground Cover (Green) 310308 310408 310508
Medium Heat Phase Cover (Red) 310309 310409 310509
Weight (kg) 3.810 4.270 5.530
COPPER JOINT Weight (lb) 8.401 9.415 12.194
Description Part No. ISOLATION SECTION
13.6mm
(0.54”)

Copper Joint 310873


Weight: 0.440kg (0.970lb) Standard Phase Cover (Orange) 310325 310425 310525
.97") Standard Ground Cover (Green) 310326 310426 310526
m (1
23 50m Medium Heat Phase Cover (Red) 310327 310427 310527
(0. mm
88 Weight (kg) 2.970 3.420 4.680
")
Weight (lb) 6.549 7.541 10.319

INSULATED EXPANSION SECTION


LENGTH: 4.5 METERS (14’ 9")

33mm +2 33mm +2
(2.13")
54mm

(1.3") (1.3")

ISOLATION SECTION
LENGTH: 4.5 METERS (14’ 9")
For use in indoor, dry, clean condi-
tions only.

750mm (29.8") 750mm (29.5")

108mm
(4.25")

Consult Insul-8 for other environments.

I NSUL-8 SAFE-LEC 2
9 Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified.
COPPER SYSTEMS

SYSTEM COMPONENTS
ISOLATION SPLICE JOINT COVER
ISO Splice Part No. Joint Cover Part No.
Copper 310972 Standard Phase 310850
Weight: 0.03 kg 0.07 lbs Standard Ground 310851
Med. Heat Phase 310855
Weight: 0.027kg (0.060lb)

(2 mm
")
66
.6
18.4 mm
(0.72 )

22.2mm
(.76") 31mm
(1.22") 121.4mm
(4.78")

(1.69")
43mm

POWERFEED and COVER END COVER


Up to 250 Amp Part No. End Cover Part No.
Standard 310910 Steel/Copper 310892
Medium Heat 310913 Weight: 0.020kg (0.044lb)
Up to 400 Amp Part No.
Standard 310912
Medium Heat 310915
Weight: 0.179kg (0.395lb)

40mm
(1.57") 230mm
(9.06")
108mm
(4.25")

68mm
(2.6")

I NSUL-8 SAFE-LEC 2
Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified. 10
ALUMINUM / STAINLESS STEEL SYSTEMS

CONDUCTOR BAR
ALUMINUM / STAINLESS STEEL
INSULATED
200 AMP 315 AMP 400 Amp
CONDUCTOR BAR INSULATED CONDUCTOR BAR Part No. Part No. Part No.
LENGTH: 4.5 METERS (14' 9")
Standard Phase Cover (Orange) 310601 310701 310501
Standard Ground Cover (Green) 310602 310702 310502
26.2mm (1.03") Medium Heat Cover (Red) 310603 310703 310503
Weight (kg) 2.100 2.300 4.380
Weight (lb) 4.631 5.072 9.658
INSULATED EXPANSION SECTION
22.3mm
(0.88")

Standard Phase Cover (Orange) 310607 310707 310507


Standard Ground Cover (Green) 310608 310708 310508
Medium Heat Phase Cover (Red) 310609 310709 310509
Weight (kg) 3.230 3.430 5.530
Weight (lb) 7.122 7.633 12.194
ALUMINUM JOINT ISOLATION SECTION
Standard Phase Cover (Orange) 310625 310725 310525
(0.33”)
8.5mm

Description Part No. Standard Ground Cover (Green) 310626 310726 310526
Aluminum 310874 ) Medium Heat Phase Cover (Red) 310627 310727 310527
.97"
Weight: 0.032kg (0.071lb) m (1 Weight (kg) 2.400 2.600 4.680
18
. 50m
(0. 2mm Weight (lb) 5.292 5.733 10.319
72
")

INSULATED EXPANSION SECTION


LENGTH: 4.5 METERS (14' 9")

54mm (2.13")
33mm + 2 33mm + 2
(1.3") (1.3")

ISOLATION SECTION
LENGTH: 4.5 METERS (14’ 9")
For use in indoor, dry, clean
conditions only.
4500mm
750mm (29.8") (14’8") 750mm (29.5")

108mm
(4.25")

Consult Insul-8 for other environments.

I NSUL-8 SAFE-LEC 2
11 Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified.
ALUMINUM / STAINLESS STEEL SYSTEMS

SYSTEM COMPONENTS
ISOLATION SPLICE POWERFEED and COVER
ISO Splice Part No. Up to 250 Amp Part No.
For Alu. / S.S. 301973 Standard 310910
Weight: 0.03 kg 0.07 lbs Medium Heat 310913
Up to 400 Amp Part No.
Standard 310912
Medium Heat 310915
Weight: 0.179kg (0.395lb)
18.4mm
(.72")

6")
(2.
22 mm
.2 66
(.7 mm 230mm
6") 40mm
(1.58") (9.06")
108mm
(4.25")

JOINT COVER END COVER


Description Part No. Description Part No.
Standard Phase 310850 Aluminum 310893
Standard Ground 310851 Weight: 0.020kg (0.044lb)
Med. Heat Phase 310855
Weight: 0.027kg (0.060lb)

31mm 121.4 mm
(1.22") (4.78")
(1.69")
43mm

68mm
(2.68")

I NSUL-8 SAFE-LEC 2
Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified. 12
COMPONENTS COMMON TO ALL SYSTEMS

M ULTI-POLE HANGERS
Multiple runs can be installed smoothly and effortlessly with these single bolt, multi-pole hangers.

4-POLE HANGER 3-POLE HANGER


Standard Mount Part No. Standard/Lateral Part No.
Black/Standard 310821 Black/Standard 310861
Red/Med. Heat 310857 Red/Med. Heat 310871
Lateral Mount Part No. Weight: 0.044kg (0.097lb)
Black 310835
Red 310859
Weight: 0.057kg (0.126lb)

8mm
(0.32")
8mm
(0.32")

27.5mm
(1.08")
27.5mm

55mm (2.17")
(1.08")
27.6mm
(1.09")

27.6mm
(1.08")

43mm (1.69") 43mm (1.69") 43mm (1.69") 115.8mm


158mm (6.22") (6.22")

Bolt size M8 = 8mm (0.32") Bolt size M8 = 8mm (0.32")

2-POLE HANGER 1-POLE HANGER


Standard/Lateral Part No. Standard/Lateral Part No.
Black/Standard 310882 Black/Standard 310824
Red/Med. Heat 310899 Red/Med. heat 310829
Weight: 0.030kg (0.066lb) Weight: 0.030kg (0.066lb)

8mm
(0.32")
8mm
(0.32")
27.5mm (1.08")
27.5mm
(1.08")

55mm (2.17")
27.6mm
(1.09")

29.8mm
72.8mm (1.17")
(2.87")

Bolt size M8 = 8mm (0.32") Bolt size M8 = 8mm (0.32")

I NSUL-8 SAFE-LEC 2
13 Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified.
COMPONENTS COMMON TO ALL SYSTEMS

ANCHOR C LAMP

ANCHOR CLAMP ANCHOR CLAMP w/ INSULATOR

Standard/Lateral Part No. Standard/Lateral Part No.


Anchor Clamp 310832 Anchor & Insulator 310969
Weight: 0.046kg (0.101lb) Weight: 0.140kg (0.309lb)

8 mm
8mm (0.32")
(0.32)

(1.18")
30mm
(1.10")
28mm

82.3mm (3.24")
59.3mm
(2.33")

Bolt size M8 = 8mm (0.32")

Bolt size
M8 = 8mm (0.32")
32mm 32.2mm
(1.26") (1.27")

SINGLE-POLE HANGERS
SINGLE-POLE HANGER w/ INSULATOR SINGLE-POLE STAINLESS STEEL
Standard/Lateral Part No.
HANGER w/ INSULATOR
Black/Standard 310918 Standard/Lateral Part No.
Red/Med. Heat 310834 SS+ Insulator 310827
Weight: 0.120kg (0.265lb) Weight: 0.130kg (0.287lb)
8mm
(0.32") 8mm
(0.32”)
(1.18")
30mm

(1.18")
30mm

(2.95")
75mm
81.3mm
(3.2")

29.8mm
(1.17")

Bolt size M8 = 8mm (0.32") Bolt size M8 = 8mm (0.32")

I NSUL-8 SAFE-LEC 2
Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified. 14
COMPONENTS COMMON TO ALL SYSTEMS

B RACKET SPACING
◗ Standard spacing = 1500 mm (59”)
◗ Lateral spacing = 1125 (44.3”)

WEB B RACKETS
STANDARD MOUNT
WEB BRACKET Standard Mount Part No. Standard Mount Part No.
457.2mm (18") 399449 260mm (10.23") 310984
Weight: 0.95kg (2.09lb) Weight: 0.540kg (1.191lb)
27.5mm
72mm (1.08") 139mm
Hole Diameter (2.84") (5.47")
10.31mm (0.41") TYP
457.2mm (18") 19mm

(1.58")
40mm
(0.75") 9mm
(0.35")
6.35mm (0.25") REF Hole Diameter 40mm
24.99mm (0.98") 9mm (0.35") TYP (1.58") 8mm 260mm (10.23")

150 mm
(0.32")

(5.9")
40.01mm (1.58") 25mm
(0.98")
45.01mm (1.77") 6mm

150mm
40mm

150mm

(5.9")
(0.24")

(5.9")
(1.58") 25mm
9mm (0.354") (0.98")

(1.77")
45mm
19.05mm (0.75") 38.1mm
(1.50") REF
21.49mm 145.01mm
(0.85") (5.71")
102.26mm TYP TYP
(4.03")

LATERAL MOUNT 165 mm (6.5”)

13.6mm
(0.54")
WEB BRACKET 44.5mm
(1.75") 43 mm
18mm (1.69”)
(0.72”) TYP

Lateral Mount Part No.


92mm (3.6") 399517
92mm
Weight: 0.91kg (2.01lb) (3.75")

4.8mm
(0.188")

45mm
(1.75") 127mm (5”)
19 mm
(0.75")

B EAM C LAMP
8mm (0.32")
NOTE: Used with flange brackets on page 16.
Two (2) beam clamps required per bracket.
50mm (1.97")

Description Part No.


Beam Clamp 310985
Weight: 0.106kg (0.234lb)

78mm (3.07")
25mm
(0.98")

I NSUL-8 SAFE-LEC 2
15 Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified.
COMPONENTS COMMON TO ALL SYSTEMS

FLANGE B RACKETS (SLOTTED)

SINGLE-SIDED
BRACKET 402.5 mm (15.8”)
Beam Part No.
80-155mm 310980
Weight: 0.540kg (1.191lb) 25mm 54mm 27.5mm
(0.98") (2.13") (1.08")
Flange Width = 3.25"- 6"
45mm 40mm 72mm 139mm
(1.77") (1.57") (2.83") (5.47")

40mm
(1.58")
20mm
(0.79")
THREE HOLES DIA = 9mm (0.35") EACH
9mm
402.5mm (15.8") (0.35")

DOUBLE-SIDED
BRACKET 500 mm (19.69")
Beam Part No.
80-185mm 310981
Weight: 0.720kg (1.588lb)
Flange Width = 3.25"-7.25" 30mm
(1.18")
27.5mm 25mm 25mm 27.5mm
(1.08") (0.95") (0.95") (1.08")
139mm 72mm 72mm 139mm
(5.47”) (2.83") (2.83") (5.47")

(1.58")
40mm
TWO HOLES: DIA = 9mm (0.35") EACH
500 mm (21.85")
SINGLE-SIDED
BRACKET 555mm (21.85”)
Beam Part No.
170-305mm 310982
Weight: 0.740kg (1.632lb)
54mm
Flange Width = 6.5"-12" (2.13”)
27.5mm
25mm 25mm (1.08”)
(0.98”) 15mm (0.98”)
(0.59”)
72mm 72mm 139mm
(2.83”) (2.83”) (5.47”)
40 mm
(1.57”)

SIX HOLES: DIA = 9mm (0.35”) EACH


555mm (21.85”)

DOUBLE-SIDED
BRACKET 700 mm (27.6”)
Beam Part No.
191-305mm 310983 54mm
Weight: 0.880kg (1.940lb) (2.13")
27.5mm 25mm 25mm
Flange Width = 7.5"-12" (1.08") (0.98") 15mm (0.98")
139 mm 72mm (0.59") 72mm 139 mm
(5.47") (2.83") (2.83") (5.47")
(1.57")
40mm

SIX HOLES DIA.= 9mm (0.35") EACH


700mm (27.6")

I NSUL-8 SAFE-LEC 2
Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified. 16
50 AMP COLLECTOR

TYPE SI

GROUND COLLECTOR Ground Collector Part No.


50 AMP COLLECTOR 50 Amp Collector Part No.
w/Deflector
Red (Phase) 399360 w/DEFLECTOR (GREEN) Left Green 399372
Green (Ground) 399380 Right Green 399373
Weight: 0.39 kg (0.87 lbs) Weight: 0.41kg (0.91 lbs)

50 AMP SHOE and HOLDER 50 Amp Shoe & Holder Part No.
Red (Phase) 310993
Green (Ground) 399357
Weight: 0.08 kgs (0.18 lbs)

51mm
(2")
108mm
(4.25")

50 AMP SHOE and HOLDER w/ DEFLECTOR (GROUND)


Ground Shoe, Holder Part No.
w/Deflector
Green (Ground) 399356
Weight: 0.10 kg (0.22 lbs)

I NSUL-8 SAFE-LEC 2
17 Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified.
50 AMP COLLECTOR B RACKETS

COLLECTOR B RACKETS FOR TYPE SI (50 AMP)


SINGLE COLLECTOR BRACKET - SHORT FOR ALL COLLECTOR BRACKETS
Length: 203mm (8 ) SHOWN ON THIS PAGE:
SHORT Part No. Weight ◗ Mounting staff = 13mm (0.51 ) square
Single 310994 0.37kg (0.82 lbs) ◗ Mounting plate thickness = 6mm (0.25 )
◗ Use only with Type SI (50 Amp) Collectors

DOUBLE COLLECTOR BRACKET - SHORT


Length: 203mm (8 )
SHORT Part No. Weight
Double 310898 0.76 kg (1.67 lbs)

SINGLE STAFF COLLECTOR BRACKET:


Dimensions for mounting plate (shown
above) is the same for both lengths.

SINGLE COLLECTOR BRACKET - LONG


Length: 406mm (16 )
LONG Part No. Weight
Single 399520 0.73 kg (1.6 lbs)

Get from Jeff

DOUBLE COLLECTOR BRACKET - LONG


Length: 406mm (16 )
LONG Part No. Weight
Double 399521 1.48 kg (3.26 lbs)

DOUBLE STAFF COLLECTOR BRACKET:


Dimensions for mounting plate (shown
above) is the same for both lengths.

I NSUL-8 SAFE-LEC 2
Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified. 18
100 AMP COLLECTOR

TYPE DI

100 AMP Collector Part No. 100 AMP GROUND Ground Collector
w/ Deflector
Part No.
Red (Phase) 310990
COLLECTOR Green (Ground) 399355
COLLECTOR Green (Left) 399352
Green (Right) 399340
Weight: 0.800kg (1.764lb) w/ DEFLECTOR Weight: 0.85kg (1.884lb)

CONTACT SURFACE
80mm
SETTING HEIGHT
102mm (4.0")

COLLECTOR EFFECTIVE (3.15")


WORKING ENVIRONMENT
SETTING
HEIGHT
22mm
(0.87")
223mm
(8.78")


22.5mm
(0.88") COLLECTOR SHOWN IN WORKING POSITION
(IN CONTACT WITH CONDUCTOR BAR)
25mm
(0.98")

368mm (14.49") Shoe & Holder Part No.


CUSTOMERS CABLE
Red (Phase) 310993
Green (Ground) 399357
100 AMP SHOE and HOLDER
Weight: 0.08 kg (0.18 lbs)

51mm
108 mm (2.0 ")
(4.25 ")

100 AMP SHOE and HOLDER w/ DEFLECTOR (GROUND)

Shoe, Holder & Deflector Part No.


Green (Ground) 399356
Weight: 0.10 kg (0.22 lbs)

I NSUL-8 SAFE-LEC 2
19 Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified.
250 AMP COLLECTOR

250 AMP

Description Part No. 63.5mm


250 AMP (2.5")
250 Amp 34956
COLLECTOR Weight: 2.05kg (4.52lb) 63.5mm
(2.5")

5.1mm
(020") REF 70mm
Contact Surface (2.75")
44.58mm
(1.25")
127mm
(5") REF

250 AMP Shoe & Holder Part No.


250 Amp 35289
SHOE and HOLDER
Weight: 0.236kg (0.52lb)

197mm (7.75 )

76.2 mm (3 )
COLLECTOR BRACKETS 25mm Part No. Weight
THESE CAN BE USED WITH Single 310991 0.85 kg (1.88 lbs)
Double 310992 1.87 kg (4.13 lbs)
100 AMP AND 250 AMP
COLLECTORS
Length: 400mm (16”) long
Staff: 25mm (1”) square

SINGLE STAFF (PLATE DIMENSIONS) DOUBLE STAFF (PLATE DIMENSIONS)

I NSUL-8 SAFE-LEC 2
Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified. 20
OTHER COMPONENTS

TRANSFER CAP

8mm 8mm
(0.32") (0.32")

65.8mm
(3.38")
37.8mm (1.49")
Description Part No.
Transfer Cap 34956
Weight: 0.11kg (.24 lbs.)
33.2mm 97mm
(1.31") (3.82")
Bolt size M8 = 8mm (.32")

PICK-U P G UIDE (TYPICAL)


Pick-Up Guides are recommended for discontinuous systems. Please consult Insul-8 for assistance in
selecting a Pick Up Guide based on application requirements. Not all systems require Pick-Up Guides.
(3.15")
80mm

433mm
(17")

JOINT COMPOUND
Description Part No.
Joint Compound 15629
Weight: 0.225 kg (0.496 lbs) Required for aluminum/stainless steel
systems only.
Optimizes electrical connection.
Enough compound provided for
over 300 connections.
Supplied at no charge with each
aluminum/stainless steel system.

I NSUL-8 SAFE-LEC 2
21 Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified.
OTHER COMPONENTS

H EATER WIRE SYSTEM


◗ Insul-8 recommends a heater wire system for your Safe-Lec 2 v-contact systems when used in
outdoor applications where frost and ice build up may occur.
◗ Thermostatic control box will automatically energize heater wire systems at temperature levels
of 35° F (1.66° C) and below.

◗ Heater wires are pre-installed with bar.

◗ Please consult Insul-8 for assistance in selecting a heater wire system for Safe-Lec 2 v-contact bar.

HEATER WIRE CONNECTION

HEATER WIRE (MALE/FEMALE) MAIN CONNECTION BOX

I NSUL-8 SAFE-LEC 2
Specifications may change without notice. All products F.O.B. Omaha, NE or Harlan, IA unless otherwise specified. 22
Solutions from a Single Source
ISO 9001 Certified

SPRING DRIVEN SLIP RINGS FESTOON CONDUCTOR BAR


REELS

Distributed By:

MOTOR DRIVEN CONDUCTOR BAR


Above is just a sampling of Insul-8 s product offering.
REELS
We have the electrification solution for you.

Please visit our website at:


www.insul-8.com

CANADA USA AUSTRALIA:


175 Boulevard J.F. Kennedy 10102 F Street 14 England Street
St. Jerome, Quebec J7Y 4B5 Omaha, NE 68127 Dandenong, Victoria 3175

Phone: (450) 565-9900 Phone: (402) 339-9300


Toll Free: (800) 667-2487 Toll Free: (800) 521-4888 Phone: (3) 9706 88 44
Fax: (450) 432-6985 Fax: (402) 339-9627 Fax: (3) 794 92 98