Documente Academic
Documente Profesional
Documente Cultură
TM
No part of this documentation shall be reproduced, stored in a ret rieval system, or transmitted by any
means, electronic, mechanical, photocopying, rec ording, or otherwise, without the prior written
permission of AVEVA. No liability is assumed with respect to the use of the information contained herein.
Although precaution has been taken in the preparation of this documentation, AVE VA assumes no
responsibility for errors or omissions. The information in this documentation is subject to change without
notice and does not represent a commitment on the part of AVEVA. The soft ware described in this
documentation is furnished under a lice nse agreement. This soft ware may be used or copied only in
accordance with the terms of such license agreement.
ArchestrA, Aquis, Avantis, Citect, DYNSIM, eDNA, EYESIM, InBatch, InduSoft, InStep, Int elaTrac,
InTouch, OASyS, PIPEPHASE, PRiSM, PRO/II, PROV ISION, ROMeo, SIM4ME, SimCentral, SimSci,
Skelta, SmartGlance, Spiral Software, Termis, WindowMaker, WindowViewer, and Wonderware are
trademarks of AVEVA and/or its subsidiaries. An extensive listing of AVEVA trademarks can be found at:
https://sw.aveva.com/legal. All other brands may be trademarks of their respective owners.
Publication date: 11/28/2018
Contact Information
AVEVA Group plc
High Cross
Madingley Road
Cambridge
CB3 OHB. UK
https://sw.aveva.com/
For information on how to cont act sales, customer training, and technical support, see
https://sw.aveva.com/contact.
PRO/II Process Engineering Silent Installation Guide
Contents
PRO/II Process Engineering Silent Install ............................................................................ 5
Silently install PRO/II 10.2 dependencies .................................................................................... 5
Silently install PRO/II 10.2 ......................................................................................................... 6
3
PRO/II Process Engineering Silent Installation Guide
5
PRO/II Process Engineering Silent Installation Guide PRO/II Process Engineering Silent Install
12. Install O2007PIA (Conditional - This is needed only if you are using Offic e 2007)
"[PRO/II 10.2 setup folder]\ThirdPartySoftware\O2007PIA\o2007pia.msi" /qn
13. Install CAPE-OPEN 64-bit (Mandatory)
"[PRO/II 10.2 setup folder]\ThirdPartySoftware\CAPE-OPEN\CAPE-OPEN64.msi"
/qn
14. Install CAPE-OPEN (Mandatory)
"[PRO/II 10.2 setup folder]\ThirdPartySoftware\CAPE-OPEN\CAPE-OPEN.msi" /qn
15. Install USB driver 7.6.8 (Conditional - This is needed only if you are going to run PRO/ II 10.2 using
USB for security)
"[PRO/II 10.2 setup folder]\ThirdPartySoftware\USB_Driver\Sentinel
Protection Installer 7.6.8.exe" /qn
16. Notepad++ (Mandatory)
[PRO/II 10.2 setup folder]\ThirdPartySoftware
\NOTEPAD\npp.7.3.3.Installer.exe /s
17. RefPropAddonSetup (Optional)
[PRO/II 10.2 setup folder]\ThirdPartySoftware\NIST\RefPropAddonSetup.exe
NOTE: RefPropAddonS etup.exe does not support Silent install. It should be installed separately from the
above path.
6
PRO/II Process Engineering Silent Install PRO/II Process Engineering Silent Installation Guide
Command example
msiexec.exe /i "PRO/II 10.2setup folder\PROII102.msi" /qn SECURITY_TYPE=FNP1113
INSTALLDIR="C:\ProgramFiles\SimSci" DESKTOP_ICON="" QUICK_LAUNCH_ICON=1
IPASSI_LICENSE_FILE=@server ADDLOCAL=ALL
The command above us es FNP1113 for security, installs PRO/II 10.2 to C: \Program Files\SimSci, does
not create the desktop icon, creates the quick launch icon, and us es machi ne FNP1113S erver for the
FNP1113 security. It also installs OPC_UAServer and Translator.