Flexibility of installation
The new TRIO-50.0 inverter is ABB’s Modular design
The forced air cooling system, designed
three-phase string solution for TRIO-50.0 has a landscape modular
for a simple and fast installation, allows
cost efficient large decentralized design to guarantee maximum flexibility.
for the maximum flexibility of installation.
photovoltaic systems for both
The inverter comes with mounting
commercial and utility applications. The separate and configurable AC and
supports for both horizontal and vertical
DC compartments increase the ease of
positions which allow for the best use
The most powerful ABB string inverter installation and maintenance with their
of space available beneath the solar
available today, this new addition to the ability to remain separately wired from
panels.
TRIO family has been designed with the inverter module inside the system.
the objective to maximize the ROI in
Design flexibility
large systems with all the advantages The TRIO comes with the most
The double stage conversion topology
of a decentralized configuration for complete wiring box configurations
offers the advantage of a wide input
both rooftop and ground-mounted available including 16 DC inputs with
voltage range for maximum flexibility of the
installations. fast connectors, monitored fuses, AC
system design.
and DC switches and monitored type II
AC and DC surge arresters.
Highlights
−− Transformerless topology
− − Each inverter is set on specific grid
codes which can be selected directly
in the field
− − Separate AC and DC compartments
are available in different
configurations
− − Wide input range
−− Both vertical and horizontal
installation
MPPT 1 Inverter
(DC/DC) (DC/AC) L1 L1, S L1 L1, S
Bulk caps
+ + IN1A(+) + Line Grid parallel L2 L2, S L2 L2, S
filter contactor
IN1B(+)
L1 L1 L1 L3 L3, S L3 L3, S
IN1C(+)
IN1 IN1 IN1D(+) N N, S N N, S
IN1 L2 L2 L2
+
L3 L3 L3 PE PE
- - IN1M(+)
IN1N(+) -
IN1O(+) Standard -S version
IN1P(+) IN1
Standard version N
PE
IN1A(-)
IN1B(-)
- L1 L1, S
IN1C(-)
IN1D(-) L2 L2, S
+ +
L3 L3, S
IN1M(-)
N N,S
IN1N(-) N N
IN1 IN1
IN1O(-) PE
Current
IN1P(-) reading OVP
monitoring
- -
DC/DC DC/AC
Current reading
-S version -SX version DSP DSP -SX version
contr. contr.
OVP monitoring
Control circuit
1_RS485
+ T/R
- T/R
GND
2_RS485
+ T/R
- T/R 2 1 3
GND
Remote control
+ R1
+ R2
µP
Expansion slot
GND
Grid standard setting
Alarm
N.C
N.O
C
1 INVERTER
Aux
N.C 2 WIRING BOX
N.O
C
3 WIRING BOX
Wiring box circuit
The AC voltage range may vary depending on specific country grid standard
1)
The Frequency range may vary depending on specific country grid standard
2)
Remark. Features not specifically listed in the present data sheet are not included in the product