BEVELED LONG EDGES / SQUARED ENDS BEVELED LONG EDGES / BEVELED ENDS 4" - Panels can be butted against 2 x 4' Panel 4" each other or spaced apart
2 x 4' Panel 4" 4"
each other or spaced apart - Recommended hat-track gauge - 20-25.
16" OC 16" OC
1'-1134"
1'-1134"
Truss Fastening Kit
8'
8'
Tectum 1" Thick Direct Attach 24" x 96" Panel - BP8181T10 SECTION A-A
A 1" SCALE 1 / 2
1'-1134"
1'-1134" TYPICAL CEILING Truss Fastening Kit is
available in:
4" Max Truss Width
ATTACHMENT METHODS Field painted -1222
White - 1222WH
4' Black - 1222BL
4' Tectum Truss
4x .250 X 45° Chamfer Fastening Kit
1"
A
Truss Fastening Kit
SECTION A-A
A SCALE 1 / 2
1"
Tectum 1" Thick Direct Attach 24" x 48" Panel - BP8182T10
Tectum 1" Thick Direct Attach 24" x 48" Panel - BP8175T10
3'-1134"
3'-1134"
24" O.C.
MAX.
8'
MAX CANTILEVER
1'-1134" 4' DRYWALL CROSS TEE
8' CEILING 1" TECTUM = 3"
APPLICATION
HANGER WIRE TO
STRUCTURE
4x .250 X 45° Chamfer
1" A DRYWALL MAIN BEAM
HD8906
DRYWALL CROSS TEE
XL8945
SECTION A-A
A 1" SCALE 1 / 4
SQUARE
Tectum 1" Thick Direct Attach 48" x 96" Panel - BP8180T10 BEVELED EDGE Tectum 1" Thick Direct Attach 48" x 96" Panel - BP8173T10
EDGE
KAM-12
TECTUM BOARD
TECTUM
MOUNTING SCREW
TYPICAL WALL ATTACHMENT METHODS
IN HIGH IMPACT AREAS FURRING FOR ONE INCH TECTUM PANELS ON WALLS SHOULD NOT EXCEED 16" O.C.
FOR WALL APPLICATIONS OF 1'-1134" WIDE PANELS, PLACE THE FURRING PERPENDICULAR TO THE PANEL AT 24" O.C. 24" O.C.
AND AT THE TOP AND BOTTOM OF THE PANELS. SPACE THE SCREWS 1" TO 2" FROM EACH PANEL EDGE AT EACH FURRING STAGGERED END JOINTS MAX.
INTERSECTION. ON CEILING USE 3 SCREWS PER FURRING.
HIGH IMPACT
NORMAL
3'-1134"
CEILING
APPLICATION
MTG.
TYPICAL MOUNTING DETAILS FOR SOUND ABSORPTION TYPE
THICKNESS NRC
HORIZONTAL PANEL
A 1" 0.40
MTG. A- LAID DIRECTLY MOUNTING C-20 0.262" 158"
MTG. C-20- LAID ON 34" A 1 1/2" 0.55 0.083" 0.138"
MOUNTING A AGAINST WALL OR
CEILING SURFACE FURRING STRIPS
A 2" 0.60
24" O.C. 16" O.C. 9
MAX. MAX. BEVELED EDGE TECTUM BEVELED EDGE TECTUM D-20 1" 0.45 64"
#2 DRIVE #6-20 THREAD
WALL OR CEILING PANEL WALL OR CEILING PANEL
D-20 1 1/2" 0.60 Tectum Direct Attach Drill Point Screw #6 x 1-5/8" - 8188L15 6459BL RIGID ATTACHMENT CLIP
ALT. DETAIL D-20 2" 0.70
1X FURRING C-20 1" 0.80
1'-1134" STRIPS 24" O.C. 0.347" 158"
1'-1134" C-20 1 1/2" 0.90
WALL APPLICATION WALL APPLICATION OR EQUAL WALL
C-20 2" 0.95
FOR WALL APPLICATIONS OF 3'-1134" TECTUM PANELS, SPACE THE FURRING AT 24" O.C. WITH FURRING AT THE TOP AND BOTTOM OF THE PANEL PERPENDICULAR
C-40 1" 0.85 0.138
TO THE PANEL DIRECTION. THREE SCREWS PER FURRING ARE REQUIRED. LOCATE THE SCREWS 1" TO 2" FROM EACH PANEL EDGE AND CENTERED. WHEN USING 7 #2 DRIVE #6-18 THREAD
VERTICAL PANEL 1" FIBERGLASS INSULATION 8" HAT CHANNEL
3'-1134" WIDE PANELS ON CEILINGS ATTACH TO THE FURRING WITH FIVE SCREWS PER FURRING. IN HIGH ABUSE AREAS SUCH AS GYMNASIUM WALLS UNDER 10' AND C-40 1 1/2" 0.95
GYMNASIUM CEILINGS UNDER 20', THE USE OF A 38" CONTINUOUS BEAD OF A CONSTRUCTION ADHESIVE CAN BE USED TO SUPPLEMENT THE SCREWS. IT IS ALSO FURRING Tectum Direct Attach Sharp Point Screw #6 x 1-5/8" - 8187L15
C-40 2" 1.00
ACCEPTABLE TO ADD A SCREW PER FURRING WHEN REPEATED IMPACTS TO THE PANELS ARE ANTICIPATED. TECTUM
NORMAL HIGH IMPACT 1"
MOUNTING C-40 0.475 0.199 216
MTG. D-20- LAID ON 34"
MOUNTING D-20 FURRING STRIPS MTG. C-40- LAID ON 1 21" 0.190
FURRING STRIPS
BEVELED EDGE TECTUM
BEVELED EDGE TECTUM DRYWALL
WALL OR CEILING PANEL
WALL OR CEILING PANEL GRID
ALT. DETAIL
Tectum Direct Attach CMU Screw 1/4" Dia. x 2 1/4" - 8189L22
ALT. DETAIL
2X FURRING
STRIPS 24" O.C.
OR EQUAL
1X FURRING 7
8" HAT CHANNEL These drawings show typical conditions in which the Armstrong product depicted is installed. PROJECT NAME:
TECTUM MASTER SHEET
R
3'-1134" 3'-1134"
WALL APPLICATION ARMSTRONG CEILING SOLUTIONS * Lancaster, PA * Phone: 877-ARMSTRONG
WALL APPLICATION