Relion ® 615 series

Capacitor bank protection and control


REV615
Compact and versatile solution for utility
and industrial power distribution systems
Protection and control for capacitor
banks in various connections

REV615 is a dedicated capacitor bank protection and REV615 is equipped with a large graphical display which
control relay for protection, control, measurement and can show customizable single-line diagrams (SLD) with
supervision of capacitor banks used for compensation of position indication for the circuit breaker, disconnectors and
reactive power in utility and industrial power distribution the earthing switch. Also measured values provided by the
systems. chosen standard configuration can be displayed. The SLDs
are customized using PCM600 and can have multiple pages
Application for easy access to selected information. The SLDs can be
REV615 has been designed to be the main protection for accessed not only locally but also via the web browser-based
H-bridge, double Y and single Y-connected capacitor banks HMI that has now been enriched with a number of usability
and feeder cables. Additionally, REV615 can be used to enhancing features.
protect harmonic filter circuits when no significant harmonic
component is higher than the 11th. Standardized communication and redundancy
REV615 fully supports the IEC 61850 standard for
REV615 is available in two standard configurations, both communication and interoperability of substation automation
of which offer three-phase overload protection, current- devices, including fast GOOSE messaging and IEC 61850-
based unbalance protection with compensation for natural 9-2 LE, and can now also benefit from the extended
unbalance, and current-based switching resonance protection interoperability provided by Edition 2. The capacitor bank
for capacitor banks. The overload protection includes an relay further supports both the parallel redundancy protocol
integrated undercurrent function which detects disconnection (PRP) and the high-availability seamless redundancy (HSR)
of a capacitor bank and inhibits the closing of the circuit protocol, together with the DNP3, IEC 60870-5-103 and
breaker for as long as the capacitor bank is partially charged. Modbus® protocols. With the protocol adapter SPA-ZC 302,
The three-phase thermal overload protection can be used for Profibus DVP1 can also be used. REV615 is able to use two
reactors and resistors in harmonic filter circuits. REV615 also communication protocols simultaneously.
offers non-directional overcurrent and earth-fault protection
for capacitor banks and their feeder cables. The other of the For redundant Ethernet communication, REV615 offers either
two standard configurations additionally offers directional two optical or two galvanic Ethernet network interfaces. A
earth-fault, residual voltage, voltage-based unbalance, and third port with a galvanic Ethernet network interface provides
over- and undervoltage protection. connectivity of any other Ethernet device to an IEC 61850
station bus inside a switchgear bay. The redundant Ethernet
One has been preconfigured for H-bridge connected solution can be built on the Ethernet-based IEC 61850,
capacitor banks and has a three-phase unbalance protection, Modbus ® and DNP3 protocols.
whereas the other has been preconfigured for double
Y-connected capacitor banks and has a single-current The implementation of the IEC 61850 standard in REV615
unbalance protection. covers both vertical and horizontal communication, including
GOOSE messaging with both binary and analog signals as
The standard configurations can be tailored to well as parameter setting according to IEC 61850-8-1. Also
meet application-specific requirements using the IEC 61850-9-2 LE process bus with sending sampled values
IEC 61850-compliant Protection and Control IED Manager of not only analog voltages but now also currents, in addition
PCM600. to receiving sampled values of voltages, is supported. For
process bus applications, which require high-accuracy time
Human-machine interface synchronization, IEEE 1588 V2 is used, with a time stamp
As a member of the Relion® product family, REV615 shares resolution of not more than four microseconds. IEEE 1588
the same human-machine interface (HMI) look and feel as the V2 is supported in all variants with a redundant Ethernet
other Relion protection and control relays and IEDs. The same communication module. In addition, REF615 supports
look and feel includes the location of a push button with a synchronization over Ethernet using SNTP or over a separate
certain function and the menu structure. bus using IRIG-B.

2 Capacitor bank protection and control | REV615


Uo

UL1UL2UL3 REV615 B
CAPACITOR BANK PROTECTION AND CONTROL RELAY STANDARD
CONFIGURATION

PROTECTION LOCAL HMI ALSO AVAILABLE

- Disturbance and fault recorders


2× 3× - Event log and recorded data
Master Trip Master Trip
- High-Speed Output module (optional)
Configuration A
System
HMI

Lockout relay Lockout relay


Time
Authorization

- Local/Remote push button on LHMI


94/86 94/86 I ESC Clear
- Self-supervision
- Time synchronization: IEEE 1588 v2,
A
O R
L
U12 0. 0 kV
P 0.00 kW
Q 0.00 kVAr SNTP, IRIG-B
- User management
IL2 0 A

- Web HMI
I ESC Clear

3I 2× AND
I2> 3Ith>T/G/C 3I>>> O R
L
OR
46 49T/G/C 50P/51P

3× 3×
ARC 3I>/Io>BF
50L/50NL CONDITION MONITORING COMMUNICATION
51BF/51NBF
3I AND SUPERVISION
Protocols:
IEC 61850-8-1/-9-2LE
3I>3I< dI>C 3dI>C 3I> FUSEF CBCM MCS 3I Modbus®
51C 51NC-1 51NC-2 51P-1 60 CBCM MCS 3I IEC 60870-5-103
DNP3
2× 2× Interfaces:
3I>> TD> OPTS TCS Ethernet: TX (RJ45), FX (LC)
51P-2 55TD OPTM TCM Serial: Serial glass fiber (ST),
Io RS-485, RS-232
Redundant protocols:
HSR
Io PRP
RSTP

2× CONTROL AND INDICATION 1) MEASUREMENT


Io Io>> Io>→ Io>>→ Io>IEF→
51N-2 67N-1 67N-2 67NIEF - I, U, Io, Uo, P, Q, E, pf, f
Object Ctrl 2) Ind 3)
- Limit value supervision
CB 1 - - Load profile record
- RTD/mA measurement (optional)
Uo DC 2 3
- Symmetrical components
ES 1 2
1)
Check availability of binary inputs/outputs Analog interface types 1)

from technical documentation Current transformer 7


UL1UL2UL3

2)
Control and indication function for
2× 2× primary object Voltage transformer 5
3U< U2> U1< 3U> 3)
Status indication function for
27 47O- 47U+ 59 1)
Conventional transformer inputs
UL1UL2UL3 primary object

Uo> PQM3I PQM3U PQMU


59G PQM3I PQM3V PQMV

PQUUB
PQVUB

REMARKS
18× 2× Optional 3× No. of Calculated OR Alternative
MAP Uo> function instances value function to be
Uo MAP 59G Io/Uo defined when
2xRTD ordering
1xmA

Iunb

Protection function overview of REV615 standard configuration B

Main benefits 615 series


− − Withdrawable plug-in unit design for swift installation and REV615 is a member of ABB’s Relion product family and
testing part of its 615 protection and control series of relays,
− − Extensive range of protection and control functionality characterized by compactness and withdrawable plug-in unit
for H-bridge, double Y and single Y-connected capacitor design. In addition to REV615, the 615 series includes the
banks and feeder cables as well as for harmonic filter following relays:
circuits
− − Ready-made standard configurations for fast and easy −− REF615 Feeder protection and control
setup with tailoring capabilities −− RED615 Line differential protection and control
− − Current-based unbalance protection with compensation −− RET615 Transformer protection and control
for natural unbalance as well as current-based switching −− REU615 Voltage protection and control
resonance protection for capacitor banks −− REM615 Motor protection and control
− − IEC 61850 Edition 2 and Edition 1 support, including HSR −− REG615 Generator and interconnection protection
and PRP, GOOSE messaging and IEC 61850-9-2 LE for
less wiring and supervised communication Life cycle services
−− IEEE 1588 V2 for high-accuracy time synchronization ABB offers full support for all protection and control relays
and maximum benefit of substation-level Ethernet throughout their entire lifecycle. Our extensive life cycle
communication services include training, customer support, maintenance and
− − Large graphical display for showing customizable SLDs, modernization.
accessible either locally or through a web browser-based
HMI

REV615 | Capacitor bank protection and control 3


Standard configurations

Standard configurations
Standard
Description
configuration
Capacitor bank overload and unbalance protection, non-directional overcurrent and earth-fault protection
A
and circuit breaker condition monitoring
Capacitor bank overload and unbalance protection, non-directional overcurrent and directional
earth-fault protection, voltage and frequence based protection and measurements, B
cicuit breaker condition monitoring

1, 2,... = number of included instances / I/Os


( ) = optional

Supported functions, codes and symbols


Functionality IEC 61850 IEC 60617 IEC-ANSI A B
Protection
Three-phase non-directional overcurrent protection, low stage PHLPTOC 3I> 51P-1 1 1
Three-phase non-directional overcurrent protection, high stage PHHPTOC 3I>> 51P-2 2 2
Three-phase non-directional overcurrent protection, instantaneous stage PHIPTOC 3I>>> 50P/51P 1 1
Non-directional earth-fault protection, low stage EFLPTOC Io> 51N-1 2 - 
Non-directional earth-fault protection, high stage EFHPTOC Io>> 51N-2 1 1
Non-directional earth-fault protection, instantaneous stage EFIPTOC Io>>> 50N/51N 1  -
Directional earth-fault protection, low stage DEFLPDEF Io> → 67N-1 -  2
Directional earth-fault protection, high stage DEFHPDEF Io>> → 67N-2 -  1
Transient/intermittent eart-fault protection INTRPTEF Io> → IEF 67NIEF - 1 1)

Negative-sequence overcurrent protection NSPTOC I2> 46 2 2


Residual overvoltage protection ROVPTOV Uo> 59G -  1+22)
Three-phase undervoltage protection PHPTUV 3U< 27 -  2
Three-phase overvoltage protection PHPTOV 3U> 59 -  1
Positive-sequence undervoltage protection PSPTUV U1< 47U+ -  1
Negative-sequence overvoltage protection NSPTOV U2> 47O- -  1
Three-phase thermal overload protection, two time constants T2PTTR 3Ith>T/G/C 49T/G/C 1 1
Circuit breaker failure protection CCBRBRF 3I>/Io>BF 51BF/51NBF 1 1
Master trip TRPPTRC Master Trip 94/86 2(5)3) 2(5)3)
Arc protection ARCSARC ARC 50L/50NL (3) (3)
Multi-purpose protection MAPGAPC MAP MAP 18 18
Three phase overload protection for shunt capacitor banks COLPTOC 3I> 3I< 51C 1 1
Current unbalance protection for SCB CUBPTOC dI>C 51NC-1 1 4)
1 4)

Three-phase current unbalance protection for H-bridge SCB HCUBPTOC 3dI>C 51NC-2 1 4)
1 4)

Capacitor bank switching resonance protection, current based SRCPTOC TD> 55TD 1 1
Power Quality
Current total demand distortion CMHAI PQM3I PQM3I (1) 5)
(1) 6)

Voltage total harmonic distortion VMHAI PQM3U PQM3V - (1) 6)

Voltage variation PHQVVR PQMU PQMV - (1) 6)

Voltage unbalance VSQVUB PQMUBU PQMUBV - (1) 6)

1) “Io measured” is always used.


2) “Uob measured” is always used.
3) Master trip is included and connected to the corresponding HSO in the configuration only when the BIO0007 module is used. If additionally the ARC option is selected,
ARCSARC is connected to the corresponding master trip input in the configuration.
4) The Iunb measurement values are taken from this block and put in the Measurent view.
5) Power quality option includes only current total demand distortion.
6) Power quality option includes current total demand distortion, voltage total harmonic distortion, voltage variation and voltage unbalance.
7) Available only with IEC 61850-9-2
8) Available only with COM0031-0037

4 Capacitor bank protection and control | REV615


1, 2,... = number of included instances / I/Os
( ) = optional

Supported functions, codes and symbols


Functionality IEC 61850 IEC 60617 IEC-ANSI A B
Control
Circuit-breaker control CBXCBR I ↔ O CB I ↔O CB 1 1
Disconnector control DCXSWI I ↔ O DCC I ↔ O DCC 2 2
Earthing switch control ESXSWI I ↔ O ESC I ↔ O ESC 1 1
Disconnector position indication DCSXSWI I ↔ O DC I ↔ O DC 3 3
Earthing switch indication ESSXSWI I ↔ O ES I ↔ O ES 2  2
Condition Monitoring
Circuit-breaker condition monitoring SSCBR CBCM CBCM 1 1
Trip circuit supervision TCSSCBR TCS TCM 2 2
Current circuit supervision CCRDIF MCS 3I MCS 3I 1 1
Fuse failure supervision SEQRFUF FUSEF 60 - 1
Runtime counter for machines and devices MDSOPT OPTS OPTM 1 1
Measurement
Disturbance recorder RDRE DR DFR 1 1
Load profile record LDPMSTA LOADPROF LOADPROF 1 1
Fault record FLTRFRC FAULTREC FAULTREC 1 1
Three-phase current measurement CMMXU 3I 3I 1 1
Sequence current measurement CSMSQI I1, I2, I0 I1, I2, I0 1 1
Residual current measurement RESCMMXU Io In 1 1
Three-phase voltage measurement VMMXU 3U 3V - 1
Residual voltage measurement RESVMMXU Uo Vn - 2
Sequence voltage measurement VSMSQI U1, U2, U0 U1, U2, U0 -  1
Three-phase power and energy measurement PEMMXU P, E P, E - 1
RTD/mA measurement XRGGIO130 X130 (RTD) X130 (RTD) (1) (1)
Frequency measurement FMMXU f f -  1
IEC 61850-9-2 LE sampled value sending 7) 8)
SMVSENDER SMVSENDER SMVSENDER -  (1)
IEC 61850-9-2 LE sampled value receiving (voltage sharing) 7) 8)
SMVRCV SMVRCV SMVRCV - (1)

REV615 | Capacitor bank protection and control 5


Contact us

For more information, please refer to

© Copyright 2016 ABB. All rights reserved.


REV615 Product Guide, or contact us:

ABB Oy, Medium Voltage Products


Distribution Automation
P.O. Box 699
FI-65101 VAASA, Finland
Phone: +358 10 22 11
Fax: +358 10 22 41094

ABB India Limited, Distribution Automation

1MRS757951 C, 5.0 FP1


Maneja Works
Vadodara – 390013, India
Phone: +91 265 272 4402
Fax: +91 265 263 8922

www.abb.com/mediumvoltage
www.abb.com/substationautomation