Sunteți pe pagina 1din 4

CRYOGENIC TEST REPORT

Client Name : SAMSUNG ENGINEERING Co.,Ltd Report No. : PK-CRV-2525-01

Project Name : SAUDI TASNEE ETHYLENE Project PK SI NO. : 06-00252

Req No. : HB22PA Test Date : 2006. 09. 18

P O No. : 4500020023-1 Ambient Temp. : 26 ℃

Description : GATE RF CL150 8" CF3/304L(FS) Ident Code. : AF2PC3C

1) Proving Test
ITEM * Initial system proving test

Temperature Ambient Temp.

Test Pressure 10Kgf/㎠

Test Result No leakage

2) Cryogenic Seat Pressure Test

ITEM Test Pressure Test Time Temperature Test Result


STAGE

Initial 2.0 ㎏f/㎠ 60 min -196 ℃ No leakage

1st 5.5 ㎏f/㎠ 3 min -196 ℃ No leakage

2nd 9.0 ㎏f/㎠ 3 min -196 ℃ No leakage

3 rd 12.5 ㎏f/㎠ 3 min -196 ℃ No leakage

Shell leakage test 12.5 ㎏f/㎠ 5 min No leakage

Restoration Test 12.5 ㎏f/㎠ 3 min Ambient Temp. No leakage

3) Operation Test * Test Pressure : 2.0 ㎏f/㎠ ※ Seating


Torque Test

Seat Torque
Operation Force Check Requiremnt Actual Requiremnt Actual
Test

Normal Opening 350 N/m 40 N/m Opening Torque 500 N/m 302 N/m

Normal Closing 350 N/m 31 N/m Closing Torque 500 N/m 198 N/m

※ Remarks

PREPARED BY REVIEWED BY APPROVED BY


WITNESSED BY
M.S. JEONG J.S. MOON

INS-QA-373-4 (1) PAN KOREA METAL IND CO., LTD


CRYOGENIC TEST REPORT
Client Name : SAMSUNG ENGINEERING Co.,Ltd Report No. : PK-CRV-2525-02

Project Name : SAUDI TASNEE ETHYLENE Project PK SI NO. : 06-00252

Req No. : HB22PA Test Date : 2006. 09. 18

P O No. : 4500020023-1 Ambient Temp. : 26 ℃

Description : GATE RF CL150 8" CF3/304L(FS) Ident Code. : AF2PC3C

1) Proving Test
ITEM * Initial system proving test

Temperature Ambient Temp.

Test Pressure 10Kgf/㎠

Test Result No leakage

2) Cryogenic Seat Pressure Test

ITEM Test Pressure Test Time Temperature Test Result


STAGE

Initial 2.0 ㎏f/㎠ 60 min -196 ℃ No leakage

1st 5.5 ㎏f/㎠ 3 min -196 ℃ No leakage

2nd 9.0 ㎏f/㎠ 3 min -196 ℃ No leakage

3 rd 12.5 ㎏f/㎠ 3 min -196 ℃ No leakage

Shell leakage test 12.5 ㎏f/㎠ 5 min No leakage

Restoration Test 12.5 ㎏f/㎠ 3 min Ambient Temp. No leakage

3) Operation Test * Test Pressure : 2.0 ㎏f/㎠ ※ Seating


Torque Test

Seat Torque
Operation Force Check Requiremnt Actual Requiremnt Actual
Test

Normal Opening 350 N/m 38 N/m Opening Torque 500 N/m 297 N/m

Normal Closing 350 N/m 28 N/m Closing Torque 500 N/m 189 N/m

※ Remarks

PREPARED BY REVIEWED BY APPROVED BY


WITNESSED BY
M.S. JEONG J.S. MOON

INS-QA-373-4 (1) PAN KOREA METAL IND CO., LTD


CRYOGENIC TEST REPORT
Client Name : SAMSUNG ENGINEERING Co.,Ltd Report No. : PK-CRV-2525-03

Project Name : SAUDI TASNEE ETHYLENE Project PK SI NO. : 06-00252

Req No. : HB22PA Test Date : 2006. 09. 18

P O No. : 4500020023-1 Ambient Temp. : 26 ℃

Description : GATE RF CL150 10" CF3/304L(FS) Ident Code. : AF2PC3C

1) Proving Test
ITEM * Initial system proving test

Temperature Ambient Temp.

Test Pressure 10Kgf/㎠

Test Result No leakage

2) Cryogenic Seat Pressure Test

ITEM Test Pressure Test Time Temperature Test Result


STAGE

Initial 2.0 ㎏f/㎠ 60 min -196 ℃ No leakage

1st 5.5 ㎏f/㎠ 3 min -196 ℃ No leakage

2nd 9.0 ㎏f/㎠ 3 min -196 ℃ No leakage

3 rd 12.5 ㎏f/㎠ 3 min -196 ℃ No leakage

Shell leakage test 12.5 ㎏f/㎠ 5 min No leakage

Restoration Test 12.5 ㎏f/㎠ 3 min Ambient Temp. No leakage

3) Operation Test * Test Pressure : 2.0 ㎏f/㎠ ※ Seating


Torque Test

Seat Torque
Operation Force Check Requiremnt Actual Requiremnt Actual
Test

Normal Opening 350 N/m 46 N/m Opening Torque 500 N/m 374 N/m

Normal Closing 350 N/m 39 N/m Closing Torque 500 N/m 288 N/m

※ Remarks

PREPARED BY REVIEWED BY APPROVED BY


WITNESSED BY
M.S. JEONG J.S. MOON

INS-QA-373-4 (1) PAN KOREA METAL IND CO., LTD


CRYOGENIC TEST REPORT
Customer : VIETNAM INVESTMENT TECHNOLOGY EQUIPMENT CO., LTD (ITECO) Report No. :
Project Name : HAI LINH LNG RECEIVING TERMINAL & REGASIFICATION PK SI NO. :
PK Job No. : 19-00428 Test Date :
P O No. : 0411/2019/ITECO-PK Ambient Temp. : 14.7℃ ~ 16.2℃
Description : CF8M BFV BWE 150# 20" GEAR TYPE (DOUBLE OFFSET, TOP ENTRY) MR No. : -
TAG No. : Cooling Medium:
Test Standard: BS 6364 - Valves for Cryogenic service Bolting Torque:

1) Initial Proving Test (Ambient temperature) (Bi-Direction)


NO Shell Strength test Shell leak test Seat Test
Remark
ITEM Acceptance STD. : No visible leakage Acceptance STD. : No visible leakage Acceptance STD.: 6cc/MinxDN

Pressure 11.5 BarG 11.5 BarG 11.5 BarG

Test Media He He He
Time 5 min 5 min. 5 min.
Test Result No visible leakage No visible leakage 0 cc/min/DN

Remark Bolting Torque Value : Good (Refer to Bolting Torque Value Report-2016-0329-001)

2) Cryogenic Test (Shell & Seat) (Bi-Direction) - Cooling medium temperature : -196°C
2.1 : Seat leakage test
ITEM Body Test Result(Acceptance STD. :
Test Pressure Test Media Test Time
STAGE Temperature 6 cc/min/DN)
Cooling down 1.5 BarG He 60 min -195.6℃ -
Initial 11.5 BarG He 5 min -194.5℃ 0 cc/min/DN
Operation(20 times) - He 5 min -194.5℃ -
1st 3.5 BarG He 5 min -194.5℃ 0 cc/min/DN
2nd 7.0 BarG He 5 min -194.5℃ 0 cc/min/DN
3rd 10.5 BarG He 5 min -194.5℃ 0 cc/min/DN
4th 11.5 BarG He 5 min -194.5℃ 0 cc/min/DN

2.2 : Shell leakage test


ITEM Body Test Result(Acceptance STD. :
Test Pressure Test Media Test Time
STAGE Temperature 6 cc/min/DN)
Test Result(Acceptance STD. :
No visible leakage)
Shell leakage test 11.5 BarG He 15 min -194.5℃ 0.0 x 10-4 ml/Sec

3) Restoration Test (Ambient Temperature) (Bi-Direction) Test Result (Acceptance STD. : 6 cc/min/DN)
Temperature Ambient Temp.
Test Media He
Seat leakage test(11.5 BarG) 5Min.
Test Result 0 cc/min/DN
Shell leakage test(11.5 BarG) Test Result(Acceptance STD.: No visible leakage) (10Min.) 0.0 x 10-4 ml/Sec

4) Operation Test
Initial Proving Test Seating Unseating 3rd at -196 +5℃ Seating Unseating
Operation Remark Operation
Max.500N Max.500N Max.500N Max.500N
(Max.350N) (Max.350N)
Open 12.9 Open 7.1
141 23 22
Close 5.7 Close 10.0
Initial at -196 +5℃ Seating Unseating 4th at -196 +5℃ Seating Unseating
Operation Remark Operation
Max.500N Max.500N Max.500N Max.500N
(Max.350N) (Max.350N)
Open 7.1 Open 11.4
151 23 121 26
Close 10.0 Close 10.0
1st at -196 +5℃ Seating Unseating Restoration test Seating Unseating
Operation Remark Operation
Max.500N Max.500N Max.500N Max.500N
(Max.350N) (Max.350N)
Open 7.1 Open 11.4
150
Close 8.6 Close 10.0
2nd at -196 +5℃ Seating Unseating Operation(20 times)
Operation Remark 1st time 20th times
Max.500N Max.500N
(Max.350N) (Max.350N) (Max.350N)
Open 7.1 Open 12.9 Open 10.0
150
Close 8.6 Close 4.3 Close 4.3
※ Remarks : Hand Wheel Dia. : 400 mm
※ Condition of valve parts after the test:
※ Conclusion / Final Result:

Inspected By Approved By Witnessed By

Kim Tae Min Jang Mun Hwan

( Mar.29, 2016 ) DATE ( Mar.29, 2016 ) DATE ( ) DATE

INS-QA-373-4 (1) PK VALVE CO., LTD

S-ar putea să vă placă și