Sunteți pe pagina 1din 2

ASME BPVC.VIII.

1-2019 6-1 – 6-5

MANDATORY APPENDIX 6
METHODS FOR MAGNETIC PARTICLE EXAMINATION (MT)

6-1 SCOPE An indication of an imperfection may be larger than the


imperfection that causes it; however, the size of the indi-
(a) This Appendix provides for procedures which shall cation is the basis for acceptance evaluation. Only indica-
be followed whenever magnetic particle examination is tions which have any dimension greater than 1/16 in.
specified in this Division. (1.5 mm) shall be considered relevant.
(b) Section V, Article 7 shall be applied for the detail re- (a) A linear indication is one having a length greater
quirements in methods and procedures, and the addi- than three times the width.
tional requirements specified within this Appendix. (b) A rounded indication is one of circular or elliptical
(c) Magnetic particle examination shall be performed shape with a length equal to or less than three times its
in accordance with a written procedure, certified by the width.
Manufacturer to be in accordance with the requirements (c) Any questionable or doubtful indications shall be
of Section V, Article 1, T-150 reexamined to determine whether or not they are
(d) Documentation showing that the required examina- relevant.
tions have been performed and that the results are ac-
ceptable shall be made available to the Inspector.
6-4 ACCEPTANCE STANDARDS
6-2 CERTIFICATION OF COMPETENCY FOR These acceptance standards shall apply unless other
NONDESTRUCTIVE EXAMINATION more restrictive standards are specified for specific mate-
PERSONNEL rials or applications within this Division.
All surfaces to be examined shall be free of:
The manufacturer shall certify that each magnetic par- (a) relevant linear indications;
ticle examiner meets the following requirements: (b) relevant rounded indications greater than 3/16 in.
(a) He/she has vision, with correction if necessary, to (5 mm);
enable him/her to read a Jaeger Type No. 2 Standard (c) four or more relevant rounded indications in a line
Chart at a distance of not less than 12 in., and is capable separated by 1/16 in. (1.5 mm) or less, edge to edge.
of distinguishing and differentiating contrast between
colors used. These requirements shall be checked
annually. 6-5 REPAIR REQUIREMENTS
(b) He/she is competent in the techniques of the mag- The defect shall be removed or reduced to an imperfec-
netic particle examination method for which he/she is tion of acceptable size. Whenever an imperfection is re-
certified, including making the examination and inter- moved by chipping or grinding and subsequent repair
preting and evaluating the results, except that where by welding is not required, the excavated area shall be
the examination method consists of more than one opera- blended into the surrounding surface so as to avoid sharp
tion, he/she may be certified as being qualified only for notches, crevices, or corners. Where welding is required
one or more of these operations. after removal of an imperfection, the area shall be cleaned
and welding performed in accordance with a qualified
6-3 EVALUATION OF INDICATIONS welding procedure.
(a) Treatment of Indications Believed Nonrelevant. Any
Indications will be revealed by retention of magnetic indication which is believed to be nonrelevant shall be re-
particles. All such indications are not necessarily imper- garded as an imperfection unless it is shown by reexam-
fections, however, since excessive surface roughness, ination by the same method or by the use of other
magnetic permeability variations (such as at the edge of nondestructive methods and/or by surface conditioning
--`,``,``,,`,`,,````,`,``,,,`-`-`,,`,,`,`,,`---

heat-a ffected zones), etc., may produce similar that no unacceptable imperfection is present.
indications. (b) Examination of Areas From Which Imperfections
Have Been Removed. After a defect is thought to have been
removed and prior to making weld repairs, the area shall
be examined by suitable methods to ensure it has been re-
moved or reduced to an acceptably sized imperfection.

429
Copyright ASME International (BPVC)
Provided by IHS under license with ASME Licensee=Khalda Petroleum/5986215001, User=Amer, Mohamed
6-5 ASME BPVC.VIII.1-2019

(c) Reexamination of Repair Areas. After repairs have method and by all other methods of examination that
been made, the repaired area shall be blended into the were originally required for the affected area, except that,
surrounding surface so as to avoid sharp notches, cre- when the depth of repair is less than the radiographic
vices, or corners and reexamined by the magnetic particle sensitivity required, reradiography may be omitted.

430
--`,``,``,,`,`,,````,`,``,,,`-`-`,,`,,`,`,,`---