Documente Academic
Documente Profesional
Documente Cultură
22 kV
Note 2
PV String 1
SCS 1
Inverter
PV String 2
CL0.2
5P20
M
PV String 3
Dry Type
3P, CL0.2
Transformer
SCS 2
SCS 3
PV String N-1
M
PV String N
SCS 4
M
To Auxilliary TX
Note 1
SCS 5
Date: 21.12.18
CEB (Green Energy) CO LTD
P.O BOX 40 ROYAL ROAD CUREPIPE MAURITIUS
Note:
TO BE RINGED WITH Standard Drawing
1. To be rated by Contractor
OTHER SOLAR
2. Contractor to size the burden of the CT.
COMPACT STATIONS Solar Compact Station (SCS)
Drawing No
HE8-EL001
SCS 1
SCS 3
SCS 4
SCS 5
SCS 2
22 kV
M M
To Auxilliary TX
Note 1
5P20
Note 2
CL0.2
3P, CL0.2
Standard Drawing
MV Switchboard of Solar
Note: TO BE RINGED WITH OTHER Compact Station
1. To be rated by Contractor SOLAR COMPACT STATIONS
Drawing No
2. Contractor to size the burden of the CT HE8-EL002
SS 8
SS 6
SS 2
SS 1
SS 7
SS 4
SS 3
SS 5
22 kV, 630A, 25kA
Protection, 5P20
M M
Metering, CL0.2
M
Backup Metering,
5P20 5P20 CL0.2
Note 5 Note 5
Auxilliary TX
Note 4
Note:
1. Contractor to liaise with CEB s team for incoming CEB network.
2. Contractor to make provision for draw pits and underground PVC pipes Date: 12.12.18
for outgoing cables complete with civil works. CEB (Green Energy) CO LTD
3. Underground 22 kV cable shall either be 300 mm2 CU or 240 mm2 AL P.O BOX 40 ROYAL ROAD CUREPIPE MAURITIUS
XLPE.
Standard Drawing
4. To be rated by Contractor.
5. Contractor to size the burden of the CT for seller s back-up meter.
Switchboard of MV
Substation (SS)
Drawing No
HE8-EL003
From SCS Legend
Switch Disconnector
3-position Disconnector
Circuit Breaker of SF6
type
Fuse
Surge Arrestor
Earth
Voltage Transformer for
Auxilliary TX Metering Purposes
Note 1
Voltage Transformer for
Protective Relay and
Metering Purposes
Current Transformer for
Metering/Protection
Y Dry Type TX
230 Vac
Inverter
PV Module
UPS Interlock
UPS
Bypass
Switch
Essential Loads
230 Vac
110 Vdc
Date: 21.12.18
CEB (Green Energy) CO LTD
P.O BOX 40 ROYAL ROAD CUREPIPE MAURITIUS
Standard Drawing
24 Vdc or 48 Vdc
(Depending on
Switchboard for Auxiliary TX
Application) for SCS
Drawing No
HE8-EL004
DC Dis tri bu ti o n AC D is tri bu ti o n M e di u m Vo l tag e S wi tc hb o ar d DC Dis tribu tio n AC D is tribu tio n M e di u m Vo l tag e S wi tc hb o ar d
22k V
22k V
P V S tri n g 1 P V S tri n g 1
In ve rte r In ve rte r
S CS 1
S CS 1
P V S tri n g 2
C L0.2
5P2 0
P V S tri n g 2
C L0.2
5P2 0
M
P V S tri n g 3 Dry T y pe Dry T y pe
P V S trin g 3
T ran sfo rm e r T ran sfo rm e r
S CS 2
S CS 2
3P, C L0.2
3P, C L0.2
2 2 k V, 6 30 A, 2 5k A
S CS 3
P V S tri n g N-1
S CS 3
P V S tri n g N-1
No te 5
M
M
P V S tri n g N P V S trin g N
S S8
M
5P2 0
S CS 4
S CS 4
M
M
T o A u xi l l ia ry
T o Au xi l l ia ry
S CS 5
No te 1
S CS 5
No te 1
TX
TX
No te 5
S S7
5P2 0
M
Au xi l li a ry T X
No te 4
S S6
S S5
3P, C L0.2
DC Dis tribu tio n AC D is tribu tio n M e di u m Vo l tag e S wi tc hb o ar d DC Dis tri bu ti o n AC D is tri bu ti o n M e di u m Vo l tag e S wi tc hb o ar d
C lie n t s S id e
C L0.2
S S4
W a l o r Fe nc e
De ma rc ati n g
22 k V
22k V
P V S tri n g 1 P V S tri n g 1
In ve rte r In ve rte r
S CS 1
S CS 1
C EB s S id e
P V S tri n g 2
C L0.2
P V S tri n g 2
5P2 0
C L0.2
5P2 0
M
P ro tec ti on ,
M e teri n g,
M e teri n g,
P V S trin g 3 Dry T y pe
B ac ku p
Dry T y pe
C L0.2
P V S tri n g 3
5P2 0
C L0.2
T ran sfo rm e r T ran sfo rm e r
S S3
S CS 2
S CS 2
3P, C L0.2
3P, C L0.2
M
S CS 3
P V S tri n g N-1 P V S tri n g N-1
S CS 3
M
S S2
P V S trin g N P V S tri n g N
3P, C L0.2
S CS 4
F rom C EB Gri d
S CS 4
No te 1
M
S S1
M
M
T o Au xi l l ia ry
T o Au xi l l ia ry
No te 1
No te 1
S CS 5
TX
S CS 5
TX
Date: 21.12.18
CEB (Green Energy) CO LTD
P.O BOX 40 ROYAL ROAD CUREPIPE MAURITIUS
Standard Drawing
Ring of Solar Compact
Stations
Drawing No
HE8-EL005
From SS Legend
Switch Disconnector
3-position Disconnector
Circuit Breaker of SF6
type
Fuse
Surge Arrestor
Earth
Voltage Transformer for
Auxilliary TX Metering Purposes
Note 1
Voltage Transformer for
Protective Relay and
Metering Purposes
Current Transformer for
Metering/Protection
230 Vac
Y Dry Type TX
Inverter
PV Module
UPS
Bypass
Switch
Date: 21.12.18
110 Vdc
CEB (Green Energy) CO LTD
P.O BOX 40 ROYAL ROAD CUREPIPE MAURITIUS
Standard Drawing
Switchboard for Auxiliary TX
for SS
24 Vdc or 48 Vdc
Drawing No
(Depending on
Application) HE8-EL006