Sunteți pe pagina 1din 15

Inside : MW 9 ppg CASE 1 : Drilling with Mud

Outside : Water 8.33 ppg

DRILLING with Mud


Burst
Internal Press External Press Burst Load Collapse Load
Depth Strength
(psi) (psi) (psi) (psi) (psi)
0 0 0 0 0 3144
500 234 217 17 0 3144
1000 468 433 35 0 3144
1772 829 768 62 0 3144

Burst Strength vs Burst Load

0 500 1,000 1,500 2,000 2,500


0
200
400
600
800
depth, f

1000
1200
1400
1600
1800
2000
Pressure, psi

Burst Load (psi) Burst Strength (psi)


CASE 1 : Drilling with Mud

Casing 20”

Collapse
Strength (psi)

1402
1402
1402
1402
30”
h vs Burst Load

2,000 2,500 3,000 3,500

20”

ssure, psi

Burst Strength (psi)


Casing 20”
Inside : MW 10 ppg CASE 1 : Drilling with Mud
Outside : Water 8.5 ppg

DRILLING with Mud


Burst
Internal Press External Press Burst Load Collapse Load
Depth Strength
(psi) (psi) (psi) (psi) (psi)
0 0 0 0 0 3144
500 260 221 39 0 3144
1000 520 442 78 0 3144
1772 921 783 138 0 3144

Burst Strength vs Burst Load

0 500 1,000 1,500 2,000 2,500


0
200
400
600
800
depth, f

1000
1200
1400
1600
1800
2000
Pressure, psi

Burst Load (psi) Burst Strength (psi)


CASE 1 : Drilling with Mud

Collapse
Strength (psi)

1407
1407
1407
1407

h vs Burst Load

2,000 2,500 3,000 3,500 Casing 20”

30

20
ssure, psi ”
Burst Strength (psi)
Casing 20”
Inside : MW 0 ppg CASE 2: Drilling with Total Loss
Outside : Water 8.33 ppg

DRILLING with Total Loss


Burst
Internal Press External Press Burst Load Collapse Load
Depth Strength
(psi) (psi) (psi) (psi) (psi)
0 0 0 0 0 3144
500 0 217 0 217 3144
1000 0 433 0 433 3144
1772 0 768 0 768 3144

Collapse Strength vs Collapse Load

0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,5


0
200
400
600
800
depth, f

1000
1200
1400
1600
1800
2000
Pressure, psi

Collapse Load (psi) Collapse Strength (psi)


CASE 2: Drilling with Total Loss

Collapse
Strength (psi)

1407
1407
1407
1407

h vs Collapse Load

3,000 3,500 4,000 4,500 5,000 5,500 6,000 Casing 20”

30

20
ssure, psi ”
Collapse Strength (psi)
Casing 20”
Inside : Mud 9 ppg CASE 3: Cementing
Outside : Cement 17 ppg

C
Burst
Internal Press External Press Burst Load Collapse Load
Depth Strength
(psi) (psi) (psi) (psi) (psi)
0 0 0 0 0 3144
500 234 442 0 208 3144
1000 468 884 0 416 3144
1772 829 1566 0 737 3144

Collapse Strength vs Collapse Load

0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,5


0
200
400
600
800
depth, f

1000
1200
1400
1600
1800
2000
Pressure, psi

Collapse Load (psi) Collapse Strength (psi)


CASE 3: Cementing
Casing 20”

Collapse
Strength (psi)

1407
1407
1407
1407 30”

h vs Collapse Load

3,000 3,500 4,000 4,500 5,000 5,500 6,000

20”

ssure, psi

Collapse Strength (psi)


Casing 20”
Inside : Mud 9 ppg CASE 4 : Running Casing
Outside : Mud 9 ppg

DRILLING with Total Loss


Burst
Internal Press External Press Burst Load Collapse Load
Depth Strength
(psi) (psi) (psi) (psi) (psi)
0 - - - - 3144
500 234 234 - - 3144
1000 468 468 - - 3144
1772 829 829 - - 3144

Axial Strength vs Axial Load

0 500,000 1,000,000 1,500,000


0
200
400
600
800
depth, f

1000
1200
1400
1600
1800
2000
Pressure, psi

Axial Load (lbs) Axial Strength (lbs)


Casi
Casing Weight 133 ppf ng
20”

Collapse Axial Strength


Strength (psi) Axial Load (lbs) (lbs)

1407 235,676 2,186,000


1407 169,176 2,186,000
1407 102,676 2,186,000
1407 - 2,186,000

ngth vs Axial Load

1,500,000 2,000,000 2,500,000

Pressure, psi

(lbs) Axial Strength (lbs)

S-ar putea să vă placă și