Documente Academic
Documente Profesional
Documente Cultură
of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Type of Protection: Flameproof enclosures ''d''; Increased safety ''e''; Protection by enclosure ''t''
Marking:
Ex d IIC Gb
Ex e IIC Gb
Ex tb III C Db
Signature:
(for printed version)
Date:
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme
Rules, IECEx 02 and Operational Documents as amended.
STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found
to comply with the following standards:
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the
Test Report:
HR/EXA/ExTR14.0014/00 HR/EXA/ExTR14.0014/01
IT/CES/QAR12.0006/01
IECEx Certificate
of Conformity
Certificate No: IECEx EXA 14.0006U Issue No: 1
Schedule
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
These breathing and draining devices (valves) are normally used in enclosures to permit for breathing and draining of the enclosure
3
itself. Maximum free internal volume of enclosure in type of protection flameproof enclosure Ex 'd' is 180 dm . The drain and breather
valve are normally made of stainless steel or brass (which may be protected by nickel).
80°C.
3
● maximum internal free volume 180 dm ,
● maximum reference pressure of 40 bar, and
● for Groups IIA, IIB and IIC.
This addendum covers the extension of applicability of ECD1** type when used with certified 'Ex d' enclosure, to include enclosures
with free internal volume of up to 180 dm3 (previously only up to 80 dm3).