Sunteți pe pagina 1din 6

IECEx Certificate

of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

Certificate No.: IECEx FMG 12.0022X Issue No: 9 Certificate history:


Issue No. 9 (2017-07-13)
Status: Current Issue No. 8 (2017-04-10)
Page 1 of 6 Issue No. 7 (2017-02-20)
Date of Issue: 2017-07-13 Issue No. 6 (2016-07-27)
Issue No. 5 (2016-03-29)
Applicant: Rosemount Inc. Issue No. 4 (2015-10-30)
8200 Market Blvd. Issue No. 3 (2014-09-12)
Chanhassen, MN 55317 Issue No. 2 (2014-07-23)
United States of America Issue No. 1 (2013-04-10)
Issue No. 0 (2012-10-26)
Equipment: Temperature Transmitter
Optional accessory:

Type of Protection: Flameproof and Dust Ignition Protection by Enclosure

Marking:
Ex d IIC T6...T1 Gb; T6...T1:Ta = -50°C to +40°C; T5...T1: Ta = -50°C to +60°C

Ex tb III C T130C Db Ta = -40°C to +70°C; IP66

Approved for issue on behalf of the IECEx J.E.Marquedant


Certification Body:

Position: VP, Manager - Electrical Systems

Signature:
(for printed version)

Date:

1. This certificate and schedule may only be reproduced in full.


2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.

Certificate issued by:


FM Approvals LLC
1151 Boston-Providence Turnpike
Norwood, MA 02062
United States of America
IECEx Certificate
of Conformity
Certificate No: IECEx FMG 12.0022X Issue No: 9

Date of Issue: 2017-07-13


Page 2 of 6

Manufacturer: Rosemount Inc.


8200 Market Blvd.
Chanhassen, MN 55317
United States of America

Additional Manufacturing location(s):

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme
Rules, IECEx 02 and Operational Documents as amended.

STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found
to comply with the following standards:

IEC 60079-0 : 2011 Explosive atmospheres - Part 0: General requirements


Edition:6.0
IEC 60079-1 : 2007-04 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Edition:6
IEC 60079-31 : 2013 Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
Edition:2

This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the

Standards listed above.

TEST & ASSESSMENT REPORTS:


A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

Test Report:

US/FMG/ExTR12.0026/00 US/FMG/ExTR12.0026/01 US/FMG/ExTR12.0026/02


US/FMG/ExTR12.0026/03 US/FMG/ExTR12.0026/04 US/FMG/ExTR12.0026/05
US/FMG/ExTR12.0026/06 US/FMG/ExTR12.0026/07 US/FMG/ExTR12.0026/08
US/FMG/ExTR12.0026/09

Quality Assessment Report:

GB/BAS/QAR06.0072/07 GB/BAS/QAR06.0072/00 GB/BAS/QAR06.0072/01


GB/BAS/QAR06.0072/02 GB/BAS/QAR06.0072/03 GB/BAS/QAR06.0072/04
GB/BAS/QAR06.0072/05 GB/BAS/QAR06.0072/06 GB/BAS/QAR06.0072/08
IECEx Certificate
of Conformity
Certificate No: IECEx FMG 12.0022X Issue No: 9

Date of Issue: 2017-07-13


Page 3 of 6

Schedule

EQUIPMENT:
Equipment and systems covered by this certificate are as follows:

644abcdefg. Temperature Transmitter.


a=Transmitter Type: F, D, H or S.
b= Transmitter Output: A, F or W.
c= Approval Option: E7, NK, K7 or KD.
d= Enclosure: D1, D2, J1, J2, J3, J4, J5, J6, J7, J8, R1, R2, R3 or R4.
e= Display and Interface: M5, M6 or blank.
f = Assembly Options: XA, XC, or Blank.

g= Other Certification Options: QT, SBS, SBV, SDN, SLL or blank

148Habcd. Temperature Transmitter.

a=Output: N.

b=Approval Option: E7, NK, K7 or KD.

c=Enclosure Option: A1, A2, G1, G2, U1, U2, H1 or H2.

d=Assembly Option: XA, XC, or Blank.

248Habcde. Temperature Transmitter.

a=Output: A or W.

b=Approval Option: E7, NK, K7 or KD.

c=Enclosure Option: A1, A2, G1, G2, U1, U2, H1 or H2.

d=Assembly Option: XA, XC or NS.

e=Other Certification Options: SBS, SBV, SDN, SLL or blank

3144Pabcdefg. Temperature Transmitter.

a= Enclosure: D1, D2, D3, D4, D5, D6, D7 or D8.

b= Transmitter Output: A or F.

c= Approval Option: E7, NF, K7 or KD.

d= Display and Interface: M5 or blank.

e= Assembly Options: XA, XC or blank.

f= Other Certification Options: QS, QT, SBS, SBV, SDN, SLL or blank
IECEx Certificate
of Conformity
Certificate No: IECEx FMG 12.0022X Issue No: 9

Date of Issue: 2017-07-13


Page 4 of 6

g= Enhanced Options: PT or blank

0085abcde. Temperature Probe.

a = Enclosure: C, D, 1, 2, G, H, 3 or 4.

b = Sensor connection: 3 or 5.

c = Extension Type: J.

d = Approval Option: E7, NK or KD.

e= Assembly Options: XA or blank.

0065abcde. Temperature Probe.

0185abcde. Temperature Probe.

a = Enclosure: C, D, 1, 2, G, H, 3, 4 or N*.

b = Sensor Lead Wire Type: 0, 1, 2, 3 or 4.

c = Extension Type: J or N.

d = Approval Option: E7, NK or KD.

e= Assembly Options: XA or blank.

*= Only available with assembly option XA.

0068abcde. Temperature Probe

0078abcde. Temperature Probe

0183abcde. Temperature Probe

a =Enclosure: R, P, D, G or N*.

b = Sensor Type: 1x, 2x or 3x (x=1, 2, 3, 4, or 5).

c =Extension Type: A, C or N.

d= Approval Option: E7, NF or KD.

e= Assembly Options: XA or blank.

*= Only available with assembly option XA.

 
IECEx Certificate
of Conformity
Certificate No: IECEx FMG 12.0022X Issue No: 9

Date of Issue: 2017-07-13


Page 5 of 6

SPECIFIC CONDITIONS OF USE: YES as shown below:

For all equipment listed above, Non-Standard Paint options may cause risk from electrostatic discharge. Avoid installations that cause
electrostatic build-up on painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special
option code, contact the manufacturer for more information.

644abcdef. Temperature Transmitter.

Specific Conditions of Use:

1. See certificate for ambient temperature range


2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments.
3. Guard the LCD cover against impact energies greater than 4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is necessary.

0065abcde. Temperature Probe.

0185abcde. Temperature Probe.

1. See certificate for ambient temperature range


2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments.
3. Guard the LCD cover against impact energies greater than 4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is necessary.
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option "N".
6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style
Sensor probe does not exceed 130 °C.
IECEx Certificate
of Conformity
Certificate No: IECEx FMG 12.0022X Issue No: 9

Date of Issue: 2017-07-13


Page 6 of 6

DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):

Minor changes to documentation that do not affect the method of protection for these models.

S-ar putea să vă placă și