IECEx Certificate

of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

Certificate No.: IECEx SIR 08.0045X Issue No: 7 Certificate history:


Issue No. 7 (2016-07-28)
Status: Current Page 1 of 7 Issue No. 6 (2016-03-04)
Issue No. 5 (2015-07-14)
Date of Issue: 2016-07-28 Issue No. 4 (2014-04-30)
Issue No. 3 (2012-07-05)
Applicant: Goyen Controls Co Pty Limited Issue No. 2 (2011-07-06)
268 Milperra Road Issue No. 1 (2009-07-29)
Milperra Issue No. 0 (2008-12-10)
NSW 2214
Australia

Equipment: The 3-6VFD# and 3-6VFD#AL Pilot Valves


Optional accessory:

Type of Protection: Flameproof and Dust

Marking: Refer to the Annexe

Approved for issue on behalf of the IECEx N Jones


Certification Body:

Position: Certification Manager

Signature:
(for printed version)

Date:

1. This certificate and schedule may only be reproduced in full.


2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.

Certificate issued by:


SIRA Certification Service
CSA Group
Unit 6, Hawarden Industrial Park
Hawarden, Deeside, CH5 3US
United Kingdom
IECEx Certificate
of Conformity
Certificate No: IECEx SIR 08.0045X Issue No: 7

Date of Issue: 2016-07-28 Page 2 of 7

Manufacturer: Goyen Controls Co Pty Limited


268 Milperra Road
Milperra
NSW 2214
Australia

Additional Manufacturing location(s):

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx
Scheme Rules, IECEx 02 and Operational Documents as amended.

STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was
found to comply with the following standards:

IEC 60079-0 : 2011 Explosive atmospheres - Part 0: General requirements


Edition:6.0
IEC 60079-1 : 2007-04 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Edition:6
IEC 60079-31 : 2013 Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
Edition:2

This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the

Standards listed above.

TEST & ASSESSMENT REPORTS:


A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

Test Report:

GB/SIR/ExTR08.0081/00 GB/SIR/ExTR09.0108/00 GB/SIR/ExTR11.0063/00


GB/SIR/ExTR14.0101/00 GB/SIR/ExTR15.0086/00 GB/SIR/ExTR16.0042/00
GB/SIR/ExTR16.0192/00

Quality Assessment Report:

AU/TSA/QAR08.0011/00
IECEx Certificate
of Conformity
Certificate No: IECEx SIR 08.0045X Issue No: 7

Date of Issue: 2016-07-28 Page 3 of 7

Schedule

EQUIPMENT:
Equipment and systems covered by this certificate are as follows:

The  3-6VFD#  and 3-6VFD#AL  Pilot Valves comprise a rectangular aluminium alloy enclosure containing solenoid pilot valves. The
enclosure comprises two halves, which when fitted together form a flanged joint. The lid is secured by ten M6 x 20 hexagonal socket
cap head screws. The enclosure may contain up to six electrical solenoids, which activate up to six pneumatic valves. The valve ferrule
tube forms a cylindrical (interference fit) joint with the enclosure. In the event of a leak process media is vented external to the
flameproof enclosure.  Cable entry facilities are provided by means of a single M25 x 1.5 or 3/4 inch NPT threaded entry facility
designed to be installed with a suitably certified cable entry facility.

The 3-6VFD# and 3-6VFD#AL Pilot Valves are identical with respect to their design and construction with the exception of the O-Ring
materials used.

Coil Voltage Cycle Power

200/240 V 50/60 Hz 25 W

100/120 V 50/60 Hz 22 W

24 V 50/60 Hz 19 W

24 V dc 20 W

36 V 50 Hz 16 W

240 V dc 24 W

110 V dc 24 W

48 V dc 20 W

12 V dc 20 W

12 V dc 30 W

SPECIFIC CONDITIONS OF USE: YES as shown below:

1. In accordance with clause 5.1 of EN 60079-1, the critical dimensions of the ferrule tube flamepaths are

Gap (i) = -0.03 mm (interference fit)

Width (L) = 10.67 mm

2. When the equipment utilises the optional e-coating, an electrostatic warning is applied as the equipment is
considered to be an electrostatic charging hazard and must only be cleaned using a damp cloth

3. The temperature class is defined by the appropriate ambient temperature as stated in the tables below:

3-6 VFD# Pilot Valves. Without anti-condensation heater.

Temperature Class (T Dust) Ambient  temperature range (Ta)


IECEx Certificate
of Conformity
Certificate No: IECEx SIR 08.0045X Issue No: 7

Date of Issue: 2016-07-28 Page 4 of 7

T6 (T85°C) -40°C to +76°C

T5 (T100°C) -40°C to +82°C

3-6 VFD#AL Pilot Valves. Without anti-condensation heater.

Temperature Class (T Dust) Ambient  temperature range (Ta)

T6 (T85°C) -52°C to +76°C

T5 (T100°C) -52°C to +82°C


IECEx Certificate
of Conformity
Certificate No: IECEx SIR 08.0045X Issue No: 7

Date of Issue: 2016-07-28 Page 5 of 7

EQUIPMENT (continued):

Duty Cycle:   0.5 sec on, 1 min off


Process details:  Air only at a maximum pressure of 8 bar
 

Design Option:  The inclusion of anti-condensation heaters as below


     

Heater Voltage Heater Power  

24 Vdc 48 W  

120 V 100 W  

240/220 V 100 W  

100 V 100 W  

Conditions of manufacture

The Manufacturer shall comply with the following:

1. The heater shall be set to turn on at a temperature of +10°C, and


turn off at a temperature of +24°C.
IECEx Certificate
of Conformity
Certificate No: IECEx SIR 08.0045X Issue No: 7

Date of Issue: 2016-07-28 Page 6 of 7

DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):

Issue 1 to Issue 5 – for changes refer to Issue 5

Issue 6 – this Issue introduced the following changes:

1 To increase the ambient temperature range of the 3-6VFD****A to


from -20°C to +40°C, to -20°C to +55°C when the anti-
condensation heater is not used.

2 Recognition of minor drawings modifications.

Issue 7 – this Issue introduced the following changes:

1 The introduction of Nitrile NBR 4117 as an alternative seal


material for the 3-6VFD#AL.

2 To increase the ambient temperature range of the 3-6VFD#,


when the anti-condensation heater is not used, from (-20°C to
+55°C), to (-40°C to +76°C) for a T6 (T85°C) temperature
class and to (‑40°C to +82°C) for a T5 (T100°C) temperature
class.

3 To increase the ambient temperature range of the 3-6VFD#,


when the anti-condensation heater is used, from (-20°C to
+40°C), to (-40°C to +40°C).

4 To increase the ambient temperature range of the 3-


6VFD#AL, when the anti-condensation heater is not used,
from (-52°C to +40°C), to (-52°C to +76°C) for a T6 (T85°C)
temperature class and to (‑52°C to +82°C) for a T5 (T100°C)
temperature class.

5 The following condition of manufacture was added for the 3-


6VFD# model, after identifying that it had been omitted in
error on certificate issue 5. ‘The heater shall be set to turn on
at a temperature of +10°C, and turn off at a temperature of
+24°C’.

6 Recognition of minor drawing modifications not affecting the


compliance of the equipment.
IECEx Certificate
of Conformity
Certificate No: IECEx SIR 08.0045X Issue No: 7

Date of Issue: 2016-07-28 Page 7 of 7

Additional information:

Conditions of manufacture
The Manufacturer shall comply with the following:
1. The E-coat shall not be applied to the flamepaths, thus
ensuring that they comply with clause 5.1 of IEC 60079-1, the
critical dimensions of the ferrule tube flamepaths shall remain
as stated in the Conditions of Certification.
2. The E-coat shall not be applied to equipment containing
heaters.
3. The Electroless nickel plating thickness on flamepaths shall
not be greater than 8 µm.
4. 3-6VFD#AL only: The cover of each enclosure shall be
subjected to a routine overpressure test of at least 14.34 bar
for a period of at least 10 seconds, as required by clause 16.1
of IEC 60079-1.  There shall be no damage, permanent
deformation or leakage other than through flamepaths
permitted
5. 3-6VFD#AL only:The heater shall be set to turn on at a
temperature of +10°C, and turn off at a temperature of +24°C.

Annex:

IECEx SIR 08.0045X Issue 7 Annexe.pdf


Annexe to: IECEx SIR 08.0045X Issue 7

Applicant: Goyen Controls Co Pty Limited

Apparatus: The 3-6VFD# and 3-6VFD#AL Pilot Valves

Marking

3-6VFD# 3-6VFD#AL
Without anti-condensation heater Without anti-condensation heater
Ex d IIB T6…T5 Gb Ex d IIB T6…T5 Gb
Ex tc IIIB T85°C…T100°C Dc IP5X Ex tc IIIB T85°C…T100°C Dc IP5X
See conditions for ambient temperatures See conditions for ambient temperatures.
Ex tb IIIC T85°C Db IP6X
Ta -20°C to +55°C.
With anti-condensation heater With anti-condensation heater
Ex d IIB T3 Gb Ex d IIB T3 Gb
Ex tc IIIB T192°C Dc IP5X Ex tc IIIB T192°C Dc IP5X
Ta -40°C to +40°C. Ta = -52°C to +40°C
Ex tb IIIC T192°C Db IP6X
Ta = -20°C to +40°C

Sira Certification Service


Unit 6, Hawarden Industrial Park,
Date: 28 July 2016 Page 1 of 1 Hawarden, CH5 3US, United Kingdom
Tel: +44 (0) 1244 670 900
Form 9530 Issue 1 Fax: +44 (0) 1244 539 301
Email: ukinfo@csagroup.org
Web: www.csagroupuk.org