nent of a required means of egress from any other part of the TABLE 1004.1.2
building. MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
FUNCTION OF SPACE OCCUPANT LOAD FACTORa
Exception: Elevators used as an accessible means of Accessory storage areas, mechanical
egress in accordance with Section 1009.4. 300 gross
equipment room
Agricultural building 300 gross
SECTION 1004 Aircraft hangars 500 gross
OCCUPANT LOAD Airport terminal
Baggage claim 20 gross
1004.1 Design occupant load. In determining means of Baggage handling 300 gross
egress requirements, the number of occupants for whom Concourse 100 gross
means of egress facilities are provided shall be determined in Waiting areas 15 gross
accordance with this section.
Assembly
1004.1.1 Cumulative occupant loads. Where the path of Gaming floors (keno, slots, etc.) 11 gross
egress travel includes intervening rooms, areas or spaces, Exhibit gallery and museum 30 net
cumulative occupant loads shall be determined in accor- Assembly with fixed seats See Section 1004.4
dance with this section.
Assembly without fixed seats
1004.1.1.1 Intervening spaces or accessory areas. Concentrated
7 net
Where occupants egress from one or more rooms, areas (chairs only—not fixed)
5 net
or spaces through others, the design occupant load Standing space
Unconcentrated (tables and chairs) 15 net
shall be the combined occupant load of interconnected
accessory or intervening spaces. Design of egress path Bowling centers, allow 5 persons for
capacity shall be based on the cumulative portion of each lane including 15 feet of runway, 7 net
occupant loads of all rooms, areas or spaces to that and for additional areas
point along the path of egress travel. Business areas 100 gross
1004.1.1.2 Adjacent levels for mezzanines. That por- Courtrooms—other than fixed seating
40 net
tion of the occupant load of a mezzanine with required areas
egress through a room, area or space on an adjacent Day care 35 net
level shall be added to the occupant load of that room, Dormitories 50 gross
area or space. Educational
1004.1.1.3 Adjacent stories. Other than for the egress Classroom area
20 net
components designed for convergence in accordance Shops and other vocational room
50 net
with Section 1005.6, the occupant load from separate areas
stories shall not be added. Exercise rooms 50 gross
1004.1.2 Areas without fixed seating. The number of Group H-5 Fabrication and manufac-
200 gross
occupants shall be computed at the rate of one occupant turing areas
per unit of area as prescribed in Table 1004.1.2. For areas Industrial areas 100 gross
without fixed seating, the occupant load shall be not less Institutional areas
than that number determined by dividing the floor area Inpatient treatment areas 240 gross
under consideration by the occupant load factor assigned Outpatient areas 100 gross
to the function of the space as set forth in Table 1004.1.2. Sleeping areas 120 gross
Where an intended function is not listed in Table 1004.1.2, Kitchens, commercial 200 gross
the building official shall establish a function based on a Library
listed function that most nearly resembles the intended Reading rooms 50 net
function. Stack area 100 gross
Exception: Where approved by the building official, Locker rooms 50 gross
the actual number of occupants for whom each occu- Mall buildings—covered and open See Section 402.8.2
pied space, floor or building is designed, although less Mercantile 60 gross
than those determined by calculation, shall be permitted Storage, stock, shipping areas 300 gross
to be used in the determination of the design occupant
Parking garages 200 gross
load.
Residential 200 gross
1004.2 Increased occupant load. The occupant load permit-
Skating rinks, swimming pools
ted in any building, or portion thereof, is permitted to be
Rink and pool 50 gross
increased from that number established for the occupancies in
Table 1004.1.2, provided that all other requirements of the Decks 15 gross
code are met based on such modified number and the occu- Stages and platforms 15 net
pant load does not exceed one occupant per 7 square feet Warehouses 500 gross
(0.65 m2) of occupiable floor space. Where required by the For SI: 1 square foot = 0.0929 m2, 1 foot = 304.8 mm.
building official, an approved aisle, seating or fixed equip- a. Floor area in square feet per occupant.