HIGH PURITY INSULATING CASTABLE

PRODUCT: ACCGUN INS 17


TYPE: INSULATING GUNNING MATERIAL
NATURE OF BOND: HYDRAULIC
INSTALLATION: GUNNING

GENERAL PROPERTIES
MAX. SERVICE TEMPERATURE: 1400 ºC
MAXIMUM GRAIN SIZE: 6 mm
WATER REQUIRED FOR CASTING: 20 – 26 %

CHEMICAL ANALYSIS, %
RANGE TYPICAL VALUE TEST PROCEDURE

Fe2O3 1.40 – 1.75 1.60 BIS 12107 Part 6


PHYSICAL PROPERTIES
RANGE TYPICAL VALUE TEST PROCEDURE
Dry density, g / cc
after drying at 110 ºC / 24 hrs 1.65 – 1.80 1.78 BIS 10570
CCS, kg/cm2
after drying at 110 ºC / 24 hrs 100 – 160 130 BIS 10570
after heating at 800 ºC / 3 hrs 70 – 110 80 BIS 10570
after heating at 1400 ºC / 3 hrs 100 – 160 140 BIS 10570
2
MOR, kg/cm
after drying at 110 ºC / 24 hrs 25 – 35 30 BIS 10570
after heating at 800 ºC / 3 hrs 15 – 25 20 BIS 10570
after heating at 1400 ºC / 3 hrs 25 – 35 30 BIS 10570
% Retained on maximum size 0–5 1.5 BIS 1528 Part 14

THERMAL PROPERTIES
RANGE TYPICAL VALUE TEST PROCEDURE
Refractoriness, Orton / ºC + 16 / + 1491 BIS 1528 Part 1
PLC, %
after heating at 800 ºC / 3 hrs (- 0.60) to (+ 0.60) - 0.37 BIS 10570
after heating at 1400 ºC / 3 hrs (- 1.50) to (- 1.50) - 0.84 BIS 10570

Thermal Conductivity, 0.43 – 0.48 0.47 WATER


kcal/m/hr/ºC CALORIMETRIC
at 500 ºC HF METHOD
Packaging: 25 kg bags Delivery State: Dry

Storage Life: Best till 9 months from the date of production, if stored in proper
condition.

Note:
(1) The data are current production averages. They can not be used as limits for specification.