Standard Features
• Equipped with a Check Flowrater for
cooling-only and heat pump operation
• Direct-drive, multi-speed motors allows
air volume variation for heating/cooling
–– Multi-speed ECM: AWUF19, 25, 31, 32, 37
–– Multi-speed PSC motor: AWUF18, 24, 30, 36
• Sequence-controlled, rust-resistant
nickel chromium heating elements
of 3, 5, 8, and 10 kW
• Factory-installed pull-type disconnect
• Aluminum tubing coils on all models
• AHRI Certified
• ETL Listed
• Thermoplastic drain pan with bottom
primary and secondary drain connections
• Built-in filter rack (filter included)
• Large chassis (2½- and 3-ton units) –
front return only
• Small chassis (1½- and 2-ton units) –
front or bottom return
• Wall-hanging bracket provided
Contents
Nomenclature .........................................2
Product Specifications ............................3
Dimensions .............................................6
Airflow Data ............................................8
Wiring Diagram .......................................9
Accessories ............................................12
*
Complete warranty details available from your local dealer or at
www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online
registration must be completed within 60 days of installation. Online registration
is not required in California or Quebec.
Nomenclature
A W U F 24 05 1 6 AA
1 2 3 4 5,6 7,8 9 10 11,12
Brand Engineering
*
A
-‐
Single-‐Piece
Air
Handler Major/
Minor
Revisions
*Not
used
for
inventory
management
Unit
Application
W
-‐
Wall
Mount
PSC
Motor Refrigerant
6
=
R-‐410A
or
R-‐22
Cabinet
Finish
U
-‐
Unpainted Electrical
1
-‐
208/240
V,
1
Phase,
60
Hz
Expansion
Device
F
-‐
Flowrater Heater
Kit
00
=
No
Heat 06
=
6
kW
Nominal
Capacity
Range 03
=
3
kW 08
=
8
kW
18,
19
=
1½
Tons 30,
31,
32
=
2½
Tons 05
=
5
kW 10
=
10
kW
24,
25
=
2
Tons 36,
37
=
3
Tons
2 www.goodmanmfg.com SS-GAWUF
Product Specifications
Specifications
AWUF AWUF AWUF AWUF AWUF AWUF AWUF AWUF AWUF AWUF
180316B 180516B 180816B 190316A 190516A 190816A 240316B 240516B 240816B 241016B
Nominal Ratings
Cooling (BTU/h) 18,000 18,000 18,000 18,000 18,000 18,000 24,000 24,000 24,000 24,000
Blower
Diameter 9 9 9 10 10 10 10 10 10 10
Width 6 6 6 6 6 6 6 6 6 6
Coil Connections
Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Suction ⅝" ⅝" ⅝" ⅝" ⅝" ⅝" ⅝" ⅝" ⅝" ⅝"
Coil Drain Connection (FPT) ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾"
Electrical Data
Voltage 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208
Minimum Circuit Ampacity (230V) 17.3 26.6 39.6 18.9 28.3 41.3 17.3 26.6 39.6 52.7
Minimum Circuit Ampacity (208V) 15.1 23.3 34.6 16.8 24.9 36.2 15.1 23.3 34.6 45.9
Minimum VAC 197 197 197 197 197 197 197 197 197 197
Maximum VAC 253 253 253 253 253 253 253 253 253 253
Blower Motor
Full Load Amps (FLA) 1.3 1.3 1.3 2.6 2.6 2.6 1.3 1.3 1.3 1.3
Horsepower (HP) 1/5 1/5 1/5 1/3 1/3 1/3 1/5 1/5 1/5 1/5
SS-GAWUF www.goodmanmfg.com 3
Product Specifications
Specifications (cont.)
AWUF AWUF AWUF AWUF AWUF AWUF AWUF AWUF AWUF AWUF
250316B 250516B 250816B 251016B 300316B 300516B 300816B 301016B 310516A* 310816A*
Nominal Ratings
Cooling (BTU/h) 24,000 24,000 24,000 24,000 30,000 30,000 30,000 30,000 30,000 30,000
Blower
Diameter 10 10 10 10 9 9 9 9 10 10
Width 6 6 6 6 8 8 8 8 8 8
Coil Connections
Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Suction ⅝" ⅝" ⅝" ⅝" ¾" ¾" ¾" ¾" ¾" ¾"
Coil Drain Connection (FPT) ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾"
Electrical Data
Voltage 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208
Minimum Circuit Ampacity (230V) 18.9 28.3 41.3 54.3 17.6 27.0 40.0 53.0 30.1 43.1
Minimum Circuit Ampacity (208V) 16.8 24.9 36.2 47.5 15.5 23.6 34.9 46.2 26.8 38.1
Minimum VAC 197 197 197 197 197 197 197 197 197 197
Maximum VAC 253 253 253 253 253 253 253 253 253 253
Blower Motor
Full Load Amps (FLA) 2.6 2.6 2.6 2.6 1.58 1.58 1.58 1.58 4.1 4.1
Horsepower (HP) 1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/2 1/2
4 www.goodmanmfg.com SS-GAWUF
Product Specifications
Specifications (cont.)
Nominal Ratings
Blower
Diameter 10 9 9 9 10 10 10
Width 8 8 8 8 8 8 8
Coil Connections
Coil Drain Connection (FPT) ¾" ¾" ¾" ¾" ¾" ¾" ¾"
Electrical Data
Minimum Circuit Ampacity (230V) 56.2 27.0 40.0 53.0 30.1 43.1 56.2
Minimum Circuit Ampacity (208V) 49.4 23.6 34.9 46.2 26.8 38.1 49.4
Blower Motor
Full Load Amps (FLA) 4.1 1.58 1.58 1.58 4.1 4.1 4.1
SS-GAWUF www.goodmanmfg.com 5
Product Specifications
Dimensions
Note - Once installed, top of unit must be level or slightly tilted back to ensure proper condensate drainage.
S UC TION LINE
OFFS E T HANG ING
LIQUID LINE
B R AC K E T
P U L L O U T DI S C O N N E C T
R E M O V AB L E
S E R V I C E DO O R
LOW V OLT
P OWE R S UP P LY
E L E C T R I C AL
P OWE R S UP P LY
F R O N T AC C E S S
P AN E L
S M AL L C H AS S I S
S T U D AT T A C H M E N T
HOLE S FR ONT R E TUR N
FILTE R
L AR G E C H AS S I S
B O T T O M P R I M AR Y AN D S E C O N DAR Y
DR AI N S C AN B E AC C E S S E D T H R O U G H T H E
B O T T O M O F T H E U N I T . ( 3 /4 " N P T F E M AL E
C ONNE C TION)
N O T E : H AN D T I G H T E N O N L Y
B 203/16" B 24"
C 16⅛" C 21"
D 16" D 19⅞"
E 11" E 15⅞"
Filter 14" x 18" x 1" Filter (30, 36,31,32,37) 18" x 20" x 1"
6 www.goodmanmfg.com SS-GAWUF
9 8 7 6 5 4
Product Specifications
36.000
F
Dimensions
.109 4.127 5.180
1.026 D
E
E
20.115
C
10.057
45 TYP. H
K
I
D A
J TOP VIEW G
F
1.026
.750
4.0"
Front
2X 88 BEND
3.0"
Bottom
DETAIL C
BOTH SIDE
SCALE 0.250
L
A
M BOTTOM VIEW
N
COMPONENTS AND MATERIALS SPECIFIED HEREIN WILL ALSO CONFORM TO THE APPLICABLE SECTION OF
SPECIAL CHARACTERISTICS: GOODMAN MSP 824.01 WORKMANSHIP STANDARD.
= 6SIGMA CC = CRITICAL CHARACTERISTIC SC = SIGNIFICANT CHARACTERISTIC CONFIDENTIAL PROPERTY OF GOODMAN MANUFACTURING COMPANY, L.P. OR ITS AFFILIATES NOT TO BE DISCLOSED TO OTHERS, CO
PURPOSE EXCEPT AS AUTHORIZED IN WRITING. MUST BE RETURNED UPON DEMAND, ON COMPLETION OF ORDER, OR OTHER PURPO
A B C D E F G H I J K L M N
9 8 7 6 5 4
AWUF 18-25 36" 20¼" 16⅛" 16" 11" 1¾" 1½" 2¼" ⅞" 1⅛" 1¾" 4" 6" 10"
AWUF 30-37 36" 24" 21" 19⅞" 16" 4⅛" 1½" 1¾" 2" 1¼" 2⅜" 4" 8" 12"
SS-GAWUF www.goodmanmfg.com 7
Product Specifications
8 www.goodmanmfg.com SS-GAWUF
208/230 VOLTS
L2 L1
DISC DISC
SS-GAWUF
RD HC HC
RD * * *
G SEE TL1 L1 T1 TL1 HTR 2 TL2 T2 L2
EBTDR
R K1 NO NOTE 5
TL2
RD XFMR-R TL1 HTR 1 TL2
XFMR-C K1 COM
* HTR1
EQUIPMENT C RD BK TL1 RD
NC
GROUND
RD BL M1 M2 TL2*
RD
EBTDR HTR2* RD
GR BK
*
FC EM
BK
* NC NO
HI
DISC DISC
M2
COM
LO
SEE NOTE 1 EBTDR
1 2 3
EBTDR TR EBTDR
BK
RD
R
SEE C G
NOTE 4 24 VOLT 5
3 R1
BL BL BK
AWUF18/24/30/36 Wiring Diagram
RD BK RD
BK BK
3 2 1 TR
BK L1 T1
RD BL WH BR GR
RD L2 T2 RD 5
RD RD 4 COLOR CODE N.E.C. CLASS 2 WIRE WIRING CODE
www.goodmanmfg.com
TERMINAL 2 FOR 208 VOLTS.
COPPER EM 2) TO PLACE AIRHANDLER IN HIGH SPEED, REMOVE RED MOTOR LEAD FROM ELECTRONIC
POWER SUPPLY BLOWER TIME DELAY RELAY (EBTDR) COM TERMINAL AND REPLACE WITH BLACK
(SEE RATING PLATE) MOTOR LEAD. ALL UNITS WILL BE FACTORY CONNECTED AT LOW SPEED.
USE MIN. 75°C FIELD WIRE
N.E.C. CLASS 2 WIRE 3) SEE COMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER
LOW VOLTAGE WIRING CONNECTIONS.
BR BR
4) ASTERISK (*) INDICATES THAT HEATING ELEMENT , THERMAL LIMIT,
AND INTERCONNECTING WIRES AND JUMPERS OF HEATER #2
ARE DELETED WITH SINGLE ELEMENT UNITS.
9
⚠
Product Specifications
6. COMPONENT CODE:
C- CONTACTOR PU SEE NOTE 1
www.goodmanmfg.com
DISC - DISCONNECT SWITCH GR PK WH BK RD
EM - EVAPORATER MOTOR 1 2 3
1 2 3 4 5
F- FUSE 240V
BK
HTR - HEATER ELEMENT EM TR
R- RELAY CL GN 5 24V 4
GR/YL
SEQ - SEQUENCER BL RD
BL BL
TL - THERMAL LIMIT BK RD
TR - TRANSFORMER WIRE COLOR BTUh
PURPLE 18000
7. FOR UNITS USING 3KW AND 5KW HEATERS, PINK 24000 BK
WHITE WIRE WILL BE CONNECTED TO
TERMINAL 4.
TABLE-1
0140A00314-A
SS-GAWUF
unit for the most up-to-date wiring.
⚠ ⚡
SS-GAWUF
NOTES:
FIELD CONNECTIONS
UNUSED WIRES MUST HAVE THEIR ENDS TAPED OR
1. RED WIRE TO BE ON TRANSFORMER SEE NOTE 2 CAPPED
USE N.E.C CLASS 2 WIRE OPTIONAL
TERMINAL "3" FOR 230 VOLTS AND ON CONNECTION
TERMINAL "2" FOR 208 VOLTS. MOTOR CONNECTIONS
ONLY ONE WILL BE CONNECTED
(SEE NOTE 2)
2. CONFIRM SPEED TAP SELECTED IS
APPROPRIATE FOR APPLICATION. IF SPEED BL GR BR
TAPS NEEDS TO BE CHANGED, CONNECT RD WH
APPROPRIATE WIRE FROM MOTOR TO BK RD
"Y" FROM THERMOSTAT/CONDENSER (SEE TABLE-1). TL1
HTR 1
3. ASTERISK (*) INDICATES THAT HEATING
ELEMENT, THERMAL LIMIT, RELAY AND BK
TL2* RD
INTERCONNECTING WIRES AND JUMPERS
PU YL
AWUF31/32 Wiring Diagram
RD
5. WIRING CODE: RD L2 T2 RD
FACTORY WIRING: RD
BK BK
HIGH VOLTAGE BK L1 T1 BK
LOW VOLTAGE BK
FIELD WIRING: C
HIGH VOLTAGE WH WH
BR F
6. COMPONENT CODE: BK
C- CONTACTOR
DISC - DISCONNECT SWITCH PU YL SEE NOTE 1
www.goodmanmfg.com
EM - EVAPORATER MOTOR GR PK WH BK RD
F- FUSE 1 2 3
1 2 3 4 5
HTR - HEATER ELEMENT 240V
BK
R- RELAY EM TR
SEQ - SEQUENCER CL GN 5 24V 4
GR/YL
TL - THERMAL LIMIT BL RD
BL BL
TR - TRANSFORMER BK RD
WIRE COLOR BTUh NOMINAL CFM
PURPLE 18000 600
PINK 24000 800 BK
0140A00276-A
11
Product Specifications
Accessories
APPROPRIATE FOR APPLICATION. IF SPEED USE N.E.C CLASS 2 WIRE
TAPS NEEDS TO BE CHANGED, CONNECT
APPROPRIATE WIRE FROM MOTOR TO RD GR BR WH YL
TERMINAL "4" ON RELAY. BL WH OR BR
BK RD
AWUF30 - AWUF37
AWUF24 - AWUF25
AWUF18 - AWUF19
3. SEE COMPOSITE WIRING DIAGRAMS IN TL1
Product Specifications
Model
BK TL2* RD
4. ASTERISK (*) INDICATES THAT HEATING HTR 2*
BK
ELEMENT, THERMAL LIMIT, RELAY AND
INTERCONNECTING WIRES AND JUMPERS
AWUF37 Wiring Diagram
SEE NOTE 4
OF HEATER #2 ARE DELETED WITH SINGLE RD
ELEMENT UNITS.
DISC RD
5. COLOR CODES:
BK - BLACK
BL - BLUE
BR - BROWN GR
GR - GREEN RD
PU - PURPLE BL
BK BL RD BL B A
RD - RED YL
WH - WHITE BL
9 7
YL - YELLOW RD L2 T2 RD
RD
6 4 RD
BK
6. WIRING CODE: BK L1 T1 BK RD
3 1 PU
FACTORY WIRING
HIGH VOLTAGE RD C
LOW VOLTAGE WH WH
WH
BK BR F
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE SEE NOTE 3 BL PU
WH SEE NOTE 1
OR BR YL BK RD
7. COMPONENT CODE:
C- CONTACTOR 1 2 3
1 2 3 4 5
DISC - DISCONNECT SWITCH 240V
EM TR
EM - EVAPORATER MOTOR
CL GN 5 24V 4
Description
F- FUSE GR/YL
HTR - HEATER ELEMENT BL RD BL RD
BL
R- RELAY BK
www.goodmanmfg.com
TR - TRANSFORMER
0140A00321-A
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without
notice or without incurring obligations. © 2015 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
Wiring is subject to change. Always
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
refer to the wiring diagram on the ⚠ Warning sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡
unit for the most up-to-date wiring.
SS-GAWUF