Sunteți pe pagina 1din 1

PEDESTAL AND BASE PLATE DESIGN - STEEL DESIGN

PROJECT TITLE: Proposed Two Storey Steel Commercial Building

DESCRIPTION: DESIGN AND ANALYSIS CALCULATION OF PEDESTAL AND BASE PLATE SECTION CAPACITY
REFERENCE CODE: NSCP C101-10, CAN3-G312.3-M78, AISC
SIGNIFICANT DATA
STEEL TYPE A36 STEEL ASTM steel designation
FY 248 Mpa yield stress of steel base plate

FY 400 MPa yield stress of steel column member

FC' 21 MPa compressive strength of concrete

ØC 0.60 - bearing reduction factor


LLENGTH 0.30 mm length of concrete pedestal
LWIDTH 0.30 mm width of concrete pedestal

PROPERTIES OF COLUMN SECTION SUBJECTED TO BASE PLATE


SECTION W200 X 46 designation column section on base plate

d 203 mm. section depth


bF 11 mm. flange base length
REQUIRED LOADINGS
PU 193000.00 N maximum factored column load

A2 90000.00 mm2 maximum area of supporting surface

AG REQ'D 18020.5415 mm2 required bearing area

OPTIMIZING BASE PLATE DIMENSIONS


∆ 92.03 mm -

N 227.00 mm -

B 80.00 mm -

A1 18160.00 mm2 -

BASE PLATE DESIGN CALCULATIONS


ØCPp 388987.20 kips -

X 0.09677 - -

λ 0.31899 - -

λn' 3.76848 mm -

m 17.07500 mm -

n 35.60000 mm -

L 35.6 mm length (large of m, n, λn')


tREQ'D 11 mm design base plate thickness