Sunteți pe pagina 1din 6

LEGEND FOR SWITCH

BOARDS (GROUND FlOOR)

SB - 1@4' 6" From FFL. SB - 10@ 6 0" From FFL(Kitchen).


1A - ceiling light - 2Nos. LED 5/15 Amp Switch & Socket - 1 Nos.
1B - ceiling light - 2Nos. LED (Water Purifier)
1C - Spot Light - 2Nos. LED
1D - Fan point - 1nos. SB - 11@ 4' 6" From FFL(Kitchen).
5/15Amp Switch/Socket-1Nos. 11A - Celling Light 1 Nos.
11B - Celling Light 1 Nos.
SB - 2@2 '9" From FFL. 11C - Fan Point With Regulater
5/15Amp Switch/Socket - 2Nos. 11D Celling light 1nos.
Telephone Point cat 6 Poin 5/15 Amp Switch & Socket - 1 Nos.

SB - 3 @2 '9" From FFL. SB - 12@ 4' 6" From FFL.


5/15Amp Switch/Socket - 2Nos. 12A - Celling Light 1 Nos.
Telephone Point cat 6 Poin 5/15 Amp Switch & Socket - 1nos.

SB - 4 @2 '9" From FFL. SB - 13@ 3'0" From FFL.


5/15Amp Switch/Socket - 2Nos. 13A - Celling light 1Nos.
Telephone Point cat 5 Poin 13B - Celling light 1Nos.
13C - Fan Point With Regulater
SB - 5 @4 '6" From FFL. 13D - Celling Light 1Nos.
5A - Celling Light - 2 Nos. LED 13E - hanging Light - 2Nos.
5B - wall Light - 1 Nos. 13F - Cove Light
Telephone Point cat 6 Poin Switch For AC
5/15Amp Switch/Socket - 1Nos. 5/15 Amp Switch & Socket - 3No.
bell switch Laptop Printer etc
telephone point Cat 6 Point
SB - 6 @4 '6" From FFL.
6A - Celling Light - 2 Nos. LED SB - 14@ 4'6" From FFL.
6B - Spot Light - 2Nos.LED 14A - Celling light 1 Nos.
6B - strip light - 2Nos. 5/15 Amp Switch & Socket - 1No.
5/15 Amp Switch & Socket - 1 nos.
SB - 15@ 4'6" From FFL.
SB - 7 @4 '6" From FFL(Kitchen). 15A - Celling Light 1Nos.
7A - Fan Point - 1Nos. 15B - Celling light 1 Nos.
5/15 Amp Switch/ Switch - 1No. 15C - Mirror Light.
Switch For exuest fan
SB - 8@4 '6" From FFL(Kitchen). 5/15 Amp Switch & Socket - 1No.
5/156 Amp S/S For fridge- 1 No. 5/15 Amp Switch For geyser Or Boiler

SB - 9@3 '6" From FFL(Kitchen). SB - 16@ 7'0" From FFL.


5/156 Amp Switch/ Switch - 2No. 5/15 Amp Socket For Geyser Or Boiler
Telephone Point cat 5 Poin
switch For exuest Fan
SB - 1 @4'6" from FFL. SB - 11@6' 9" from FFL(bed rm 1).
1A - Celling Light - 2 Nos. LED 5/15 Amp Switch for geyser or boiler
5/15 Amp Switch & Socket - 1Nos.
SB - 12@4' 9" from FFL(bed rm 2).
SB - 2 @4'6" from FFL. 12A - Celling Light - 3 nos. LED
2A - Spot light - 1nos. (2 way point).
2B - Fan point - 1nos. 12B - fan & regulator
2C - Celling Light - 3nos. LED (2 way point).
2D - Amp Switch Light 5/15 Amp Switch / Switch - 1No.
5/15 Amp Switch / Switch - 1No.
telephone point SB - 13@2' 0" from FFL(bed rm 2).
12A - Celling Light - 3 nos. LED
SB - 3 @4'6" from FFL(bed rm 1). (2 way point).
3A - Celling Light - 3Nos. LED 12B - fan & regulator
(2 way Point). (2 way point).
3B - fan & Regulator 13A - Celling light 3 nos. LED
(2 way Point). 13A - Wall light 3
5/15 Amp Switch & Socket - 1Nos. 13C - Cove Light
13C - AC Point
SB - 4 @4'6" from FFL(bed rm 1). 5/15 Amp Switch / Switch - 1No.
3A - Celling Light - 3Nos. LED telephone point
(2 way Point).
3B - fan & Regulator SB - 14@2' 0" from FFL(bed rm 2).
(2 way Point). 5/15 Amp Switch / Switch - 1No.
4A- Wall light telephone point
4C - Cove light
4D - AC point SB - 15@2' 8" from FFL(bed rm 2).
5/15 Amp Switch & Socket - 1 nos. 5/15 Amp Switch / Switch - 1No.

SB - 5@2'0" from FFL(bed rm 1). SB - 16@4' 0" from FFL(bed rm 2).


5/15 Amp Switch & Socket - 1 nos. (T.V.Point).
telephone point
SB - 17@2' 0" from FFL(bed rm 2).
SB - 6@2' 8" from FFL(bed rm 1). 5/15 Amp Switch - 1No.
5/15 Amp Switch & Socket - 1 nos. (T.V.Point).
cat 6 5/15 Amp Switch & Socket - 2No.
5/15 Amp Switch & Socket - 2No.
SB - 7@4' 0" from FFL(bed rm 1). (steup Box , DvD, Speker).
5/15 Amp Socket - 1 nos.
(T.V. Point). SB - 18@4' 6" from FFL(bed rm 2).
18A - Celling light 1 nos.
SB - 8@2' 0" from FFL(bed rm 1). 18 B - Mirroe Light.
5/15 Amp Socket - 1 nos. Switch for exuest fan
(T.V. Point). 5/15 Amp Switch & Socket - 1No.
5/15 Amp Switch & Socket - 2 nos. 5/15 Amp Switch For geyser Or Boiler
5/15 Amp Switch & Socket - 2 nos.
(Steup Box, DvD Spekar). SB - 19@6' 9" from FFL(bed rm 2).
5/15 Amp Sockrt For geyser Or Boiler
SB - 9@2' 0" from FFL(bed rm 1).
9A - Wall ligh.
9B - Celling light.
5/15 Amp Switch & Socket - 1 nos.

SB - 10@4' 6" from FFL(bed rm 1).


10A - Celling light 1 nos.
10B - Celling light 1nos.
10C - Mirror light.
switch for exuest fan
5/15 Amp Switch & Socket - 1nos.
5/15 Amp Switch for geyser or boiler
SB - 20@ 4' 6" from FFL(bed rm 3).
20A - Celling Light 3 Nos. LED
(2 way point).
20B - fan & regulator
(2 way point).
5/15 Amp Switch / Sockrt - 1Nos.

SB - 21@ 2' 0" from FFL(bed rm 3).


20A - Celling Light 3 Nos. LED
(2 way point).
20B - fan & regulator
(2 way point).
21A - Celling light - 3 nos. LED
21B - Wall light
21C - cove light
21D - AC point
5/15 Amp Switch / Socket - 1No.
telephone point

SB - 22@ 2' 0" from FFL(bed rm 3).


5/15 Amp Switch / Socket - 1No.
telephone point

SB - 23@ 4' 0" from FFL(bed rm 3).


5/15 Amp Socket - 1No.
(T.V. point).

SB - 24@ 2' 0" from FFL(bed rm 3).


5/15 Amp Socket - 1No.
(T.V. point).
5/15 Amp Switch / Socket - 2Nos.
5/15 Amp Switch / Socket - 2Nos.
(steup Box , DvD, Speker).

SB - 25@ 4' 6" from FFL(bed rm 3).


25A - Wall light
25B - Celling Light.
5/15 Amp Switch & Socket - 1No.

SB - 26@ 4' 6" from FFL(bed rm 3).


26A - Celling light 1 nos.
26B - Celling light 1 Nos.
Switch For exust fan
5/15 Amp Switch & Socket - 1No.
5/15 Amp Switch For geyser Or Boiler

SB - 27@ 6' 9" from FFL(bed rm 3).


5/15 Amp Switch For geyser Or Boiler

S-ar putea să vă placă și