Sunteți pe pagina 1din 6

Sheet No.

name date
Design
Project Check
Bulding Approve

Pile Cap Design for 2-Piles Pattern Acc. to ACI 318-11


1- Inpu data
1-1 Section properties
Pile diameter D 750 mm
Column size (Parallel to Moment) Cx 1000 mm
Column size ( perpendicular) Cy 400 mm
Pile clear dist. Cl 1200 mm
Edge distance e 125 mm
Effective depth d 1000 mm
Bottom reinforcement 10 ϕ 25 mm
1-2 Single pile max loads or capacity
Axial force capacity fPn 1900.00 KN
Moment capacity at the top fMn 0.00 KN.m
shear capacity fVn 0.00 KN
1-3 Materials properties
Concrete strength fc' 25 Mpa
Rebar yield stress fy 460 Mpa
Modulus of elasticity Ec 23500 Mpa
Shear modulus G 9792 Mpa
1-4 Loading
Axial force Pu 3800 KN max 3800 KN
Moment capacity at the top Mu 0 KN.m max 0 KN.m
shear Vu 0 KN max 0 KN
2- Analysis
2-1 CHECK FLEXURE CAPACITY AT COLUMN FACE (ACI 318-08, 10.2, 10.3, 10.5, 7.12.2)

Pile Spacing = S= 1950 mm


Cap Edge Length = Le 2950 mm
Length of section 1-1 L 1-1 = 1000 mm
M u, 1-1 = (to middle of cap elevation) 1189.1 KN.m/m
r provided = 0.0049
1.6987

0.0039 < 0.0049 OK 79%

0.850

0.0222

0.0167 > 0.0049 OK 29%

0.0018 < 0.0049 OK 37%


Sheet No.
name date
Design
Project Check
Bulding Approve

2-2 CHECK ONE WAY SHEAR CAPACITY AT THE FACE OF COLUMN & PILE ( ACI 318-08, Chapter 11 )

As per ACI 318-08, Sec. 9.3.2.3 ϕ = 0.75


Length of section 3-3 L 3-3 = 1000 mm
Length of section 2-2 L 2-2 = 1000 mm
Distance Between pile and column edge = 475 mm
Half of effective depth d/2 = 500 mm
Shear capacity of base ber length unit ;
ϕ V c = 0.16 ϕ b d (f c ') 0.5 = 600 KN/m
Applied shear forces due to pile loads
V u 2-2 = 2(ϕ P n ) /L 2-2 = V u 2-2 = 0 KN/m < ϕVc OK 0%

2-2 CHECK COLUMN PUNCHING CAPACITY (ACI 318-08, 11.4.7.4, 11.11.1.2, 11.11.6 & 13.5.3.2)

Punching shear is checked on a perimeter 0.5d=500 m from the column face.


Parallel to Moment Dir. length b 1 1400 mm
perpendicular to Moment Dir. length b 2 2000 mm
Critical perimeter b 0 = 2b 1 +2b 2 = 4000 mm
For rectangular column β = l/b = 0.40
Cap,vc shall be the smallest of (a), (b), and (c):
2
(a) : v c1 = 0.17(1+2/β).λ.√f’ c . = 5.10 N/mm
2
(b) : v c2 = 0.083(2+40d/b 0 ).λ.√f’ c . = 1.66 N/mm
2
(c) : v c3 = 0.33.λ.√f’ c . = 1.65 N/mm
2
ϕ v c = ϕ Min( V c1 ,V c2 ,V C3 ) = 1.24 N/mm
A p = b 0 .d = 4.00E+06 mm 2
γ v =1- 1/[ 1+(2/3) √(b 1 / b 2 )] = 0.36
 d b3    d  2  b 
J   1  1     3  2    2.65E+12 mm 4
 6    b1   b1  
 
2
v u =P u,col /A p + (0.5 γv M u,col .b 1 )/J 0.950 N/mm < ϕvc OK 77%
2-3 CHECK SINGLE PILE PUNCHING CAPACITY (ACI 318-08, 11.4.7.4, 11.11.1.2, 11.11.6 & 13.5.3.2)

Punching arc angle α= 69.7 Degree


b 1 = b 2 = ( α/360) * ( πD/4 + d) = 308 mm
Critical perimeter b 0 =( α/360) ( πD + d ) 650 mm
A p = b 0 .d = 6.50E+05 mm 2
γ v =1- 1/[ 1+(2/3) √(b 1 / b 2 )] = 0.40
polar moment of inertia J= 7.07E+10 mm 4
2
(a) : v c1 = 0.17(1+2/β).λ.√f’ c . = 2.55 N/mm
2
(b) : v c2 = 0.083(2+40d/b 0 ).λ.√f’ c . = 1.66 N/mm
2
(c) : v c3 = 0.33.λ.√f’ c . = 1.65 N/mm
2
ϕ v c = ϕ Min( V c1 ,V c2 ,V C3 ) = 1.24 N/mm
2
v u =P u,col /A p + (0.5 γv M u,col .b 1 )/J 6.196 N/mm > ϕvc Not OK 501%
Sheet No.
name date
Design
Project Check
Bulding Approve

Pile Cap Design for 3-Piles Pattern Acc. to ACI 318-08


1- Inpu data
1-1 Section properties
Pile diameter D 750 mm
Column size (Parallel to Moment) Cx 1200 mm
Column size ( perpendicular) Cy 600 mm
Pile clear dist. Cl 1200 mm
Edge distance e 250 mm
Effective depth d 1000 mm
Bottom reinforcement 10 ϕ 25 mm
1-2 Single pile max loads or capacity
Axial force capacity fPn 1900.00 KN
Moment capacity at the top fMn 0.00 KN.m
shear capacity fVn 0.00 KN
1-3 Materials properties
Concrete strength fc' 25 Mpa
Rebar yield stress fy 460 Mpa
Modulus of elasticity Ec 23500 Mpa
Shear modulus G 9792 Mpa
1-4 Loading
Axial force Pu 5700.00 KN max 5700 KN
Moment capacity at the top Mu 0.00 KN.m max 0 KN.m
shear Vu 0.00 KN max 0 KN
2- Analysis
2-1 CHECK FLEXURE CAPACITY AT COLUMN FACE (ACI 318-08, 10.2, 10.3, 10.5, 7.12.2)

Pile Spacing = S= 1950 mm


Cap Edge Length = Le 4115 mm
Length of section 1-1 L 1-1 = 2051 mm
Length of section 2-2 L 2-2 = 3436 mm
M u, 1-1 = (to middle of cap elevation) 487.2 KN.m/m
M u, 2-2 = (to middle of cap elevation) 0.0 KN.m/m
r provided = 0.0049
0.6960

0.0015 < 0.0049 OK 31%

0.850

0.0222

0.0167 > 0.0049 OK 29%


0.0018 < 0.0049 OK 37%
Sheet No.
name date
Design
Project Check
Bulding Approve

2-2 CHECK ONE WAY SHEAR CAPACITY AT THE FACE OF COLUMN & PILE ( ACI 318-08, Chapter 11 )

As per ACI 318-08, Sec. 9.3.2.3 ϕ = 0.75


Length of section 3-3 L 3-3 = 1876 mm
Length of section 2-2 L 2-2 = 3436 mm
Distance Between pile and column edge = 244 mm
Half of effective depth d/2 = 500 mm
Shear capacity of base ber length unit ;
ϕ V c = 0.16 ϕ b d (f c ') 0.5 = 600 KN/m
Applied shear forces due to pile loads
V u 2-2 = 2(ϕ P n ) /L 2-2 = V u 2-2 = 0 KN/m < ϕVc OK 0%
V u 3-3 = (ϕ P n ) /L 3-3 = V u 3-3 = 0 KN/m < ϕVc OK 0%

2-2 CHECK COLUMN PUNCHING CAPACITY (ACI 318-08, 11.4.7.4, 11.11.1.2, 11.11.6 & 13.5.3.2)

Punching shear is checked on a perimeter 0.5d=500 m from the column face.


Parallel to Moment Dir. length b 1 1600 mm
perpendicular to Moment Dir. length b 2 2200 mm
Critical perimeter b 0 = 2b 1 +2b 2 = 4000 mm
For rectangular column β = l/b = 0.50
Cap,vc shall be the smallest of (a), (b), and (c):
2
(a) : v c1 = 0.17(1+2/β).λ.√f’ c . = 4.25 N/mm
2
(b) : v c2 = 0.083(2+40d/b 0 ).λ.√f’ c . = 1.66 N/mm
2
(c) : v c3 = 0.33.λ.√f’ c . = 1.65 N/mm
2
ϕ v c = ϕ Min( V c1 ,V c2 ,V C3 ) = 1.24 N/mm
A p = b 0 .d = 4.00E+06 mm 2
γ v =1- 1/[ 1+(2/3) √(b 1 / b 2 )] = 0.36
 d b3    d  2  b 
J   1  1     3  2    3.77E+12 mm 4
 6    b1   b1  
 
2
v u =P u,col /A p + (0.5 γv M u,col .b 1 )/J 1.425 N/mm > ϕvc Not OK 115%
2-3 CHECK SINGLE PILE PUNCHING CAPACITY (ACI 318-08, 11.4.7.4, 11.11.1.2, 11.11.6 & 13.5.3.2)

Punching arc angle α= 151.2 Degree


b 1 = b 2 = ( α/360) * ( πD/4 + d) = 667 mm
Critical perimeter b 0 =( α/360) ( πD + d ) 1409 mm
A p = b 0 .d = 1.41E+06 mm 2
γ v =1- 1/[ 1+(2/3) √(b 1 / b 2 )] = 0.40
polar moment of inertia J= 3.09E+11 mm 4
2
(a) : v c1 = 0.17(1+2/β).λ.√f’ c . = 2.55 N/mm
2
(b) : v c2 = 0.083(2+40d/b 0 ).λ.√f’ c . = 1.66 N/mm
2
(c) : v c3 = 0.33.λ.√f’ c . = 1.65 N/mm
2
ϕ v c = ϕ Min( V c1 ,V c2 ,V C3 ) = 1.24 N/mm
2
v u =P u,col /A p + (0.5 γv M u,col .b 1 )/J 4.303 N/mm > ϕvc OK 348%
Sheet No.
name date
Design
Project Check
Bulding Approve

Pile Cap Design for 4-Piles Pattern Acc. to ACI 318-08


1- Inpu data
1-1 Section properties
Pile diameter D 250 mm
Column size (Parallel to Moment) Cx 500 mm
Column size ( perpendicular) Cy 500 mm
Pile clear dist. Cl 1250 mm
Edge distance e 225 mm
Effective depth d 400 mm
Bottom reinforcement 6 ϕ 16 mm
1-2 Single pile max loads or capacity
Axial force capacity fPn 307.50 KN
Moment capacity at the top fMn 0.00 KN.m
shear capacity fVn 0.00 KN
1-3 Materials properties
Concrete strength fc' 30 Mpa
Rebar yield stress fy 460 Mpa
Modulus of elasticity Ec 25743 Mpa
Shear modulus G 10726 Mpa
1-4 Loading
Axial force Pu 1230 KN max 1230 KN
Moment capacity at the top Mu 0 KN.m max 0 KN.m
shear Vu 0 KN max 0 KN
2- Analysis
2-1 CHECK FLEXURE CAPACITY AT COLUMN FACE (ACI 318-08, 10.2, 10.3, 10.5, 7.12.2)

Pile Spacing = S= 1500 mm


Cap Edge Length = Le 2200 mm
Length of section 1-1 L 1-1 = 2404 mm
Length of section 2-2 L 2-2 = 2200 mm
M u, 1-1 = (to middle of cap elevation) 210.0 KN.m/m
M u, 2-2 = (to middle of cap elevation) 139.8 KN.m/m
r provided = 0.0049
1.8746

0.0042 < 0.0049 OK 86%

0.836

0.0262

0.0197 > 0.0049 OK 25%


0.0018 < 0.0049 OK 37%
Sheet No.
name date
Design
Project Check
Bulding Approve

2-2 CHECK ONE WAY SHEAR CAPACITY AT THE FACE OF COLUMN & PILE ( ACI 318-08, Chapter 11 )

As per ACI 318-08, Sec. 9.3.2.3 ϕ = 0.75


Length of section 3-3 L 3-3 = 1490 mm
Length of section 2-2 L 2-2 = 2200 mm
Distance Between pile and column edge = 707 mm
Half of effective depth d/2 = 200 mm
Shear capacity of base per length unit ;
ϕ V c = 0.16 ϕ b d (f c ') 0.5 = 263 KN/m
Applied shear forces due to pile loads
V u 2-2 = 2(ϕ P n ) /L 2-2 = V u 2-2 = 280 KN/m > ϕVc Not OK 106%
V u 3-3 = (ϕ P n ) /L 3-3 = V u 3-3 = 206 KN/m < ϕVc OK 78%

2-2 CHECK COLUMN PUNCHING CAPACITY (ACI 318-08, 11.4.7.4, 11.11.1.2, 11.11.6 & 13.5.3.2)

Punching shear is checked on a perimeter 0.5d=200 m from the column face.


Parallel to Moment Dir. length b 1 900 mm
perpendicular to Moment Dir. length b 2 900 mm
Critical perimeter b 0 = 2b 1 +2b 2 = 3600 mm
For rectangular column β = l/b = 1.00
Cap,vc shall be the smallest of (a), (b), and (c):
2
(a) : v c1 = 0.17(1+2/β).λ.√f’ c . = 2.79 N/mm
2
(b) : v c2 = 0.083(2+40d/b 0 ).λ.√f’ c . = 1.82 N/mm
2
(c) : v c3 = 0.33.λ.√f’ c . = 1.81 N/mm
2
ϕ v c = ϕ Min( V c1 ,V c2 ,V C3 ) = 1.36 N/mm
A p = b 0 .d = 1.44E+06 mm 2
γ v =1- 1/[ 1+(2/3) √(b 1 / b 2 )] = 0.40
 d b3    d  2  b 
J   1  1     3  2    2.04E+11 mm 4
 6    b1   b1  
 
2
v u =P u,col /A p + (0.5 γv M u,col .b 1 )/J 0.854 N/mm < ϕvc OK 63%
2-3 CHECK SINGLE PILE PUNCHING CAPACITY (ACI 318-08, 11.4.7.4, 11.11.1.2, 11.11.6 & 13.5.3.2)

Punching arc angle α= 270.0 Degree


b 1 = b 2 = ( α/360) * ( πD/4 + d) = 447 mm
Critical perimeter b 0 =( α/360) ( πD + d ) 889 mm
A p = b 0 .d = 3.56E+05 mm 2
γ v =1- 1/[ 1+(2/3) √(b 1 / b 2 )] = 0.40
polar moment of inertia J= 2.86E+10 mm 4
2
(a) : v c1 = 0.17(1+2/β).λ.√f’ c . = 2.79 N/mm
2
(b) : v c2 = 0.083(2+40d/b 0 ).λ.√f’ c . = 1.82 N/mm
2
(c) : v c3 = 0.33.λ.√f’ c . = 1.81 N/mm
2
ϕ v c = ϕ Min( V c1 ,V c2 ,V C3 ) = 1.36 N/mm
2
v u =P u,col /A p + (0.5 γv M u,col .b 1 )/J 5.021 N/mm > ϕvc Not OK 370%