Sunteți pe pagina 1din 2

PROJECT: PROPOSED DESIGN OF A FOUR STOREY SCHOOL BUILDING

PREPARED BY: JOYCE ANN M. BULANADI

DESIGN CRITERIA

LOAD DESCRIPTION VALUE MIN VALUE SECTION


ROOF DECK
I.DEAD LOADS
1.1 CONCRETE
Slab per 100 mm thickness 24 kn/cu.m 23.6 kn/cu.m Section 204 table 204-1
1.2 FLOORING
Plain cement finish 1.7 1.53 kpa Section 204 table 204-2
Waterproofing 0.3 kpa 0.26 kpa Section 204 table 204-2
1.3 ME
II. LIVE LOADS
ROOF DECK 4 kpa 3.8 kpa Section 205 table 205-1

FOURTH FLOOR-GROUND FLOOR ( TYPICAL )


I.DEAD LOADS
1.1 CONCRETE
Slab per 100 mm thickness 24 kn/cu.m 23.6 kn/cu.m Section 204 table 204-1
NOTE: Slab thickness in ground floor is 200 mm.
1.2 FLOORING
Plain cement finish 1.7 kpa 1.53 kpa Section 204 table 204-2
Waterproofing 0.007 kpa 0.005 kpa Section 204 table 204-2
1. 3 WALL PARTITIONS
Exterior wall (200 mm thk CHB) 4.36 kpa 3.59 kpa Section 204 table 204-1
Interior wall (150 mm thk CHB) 3.3 kpa 2.63 kpa Section 204 table 204-1
II. LIVE LOADS
FOURTH FLOOR
Reading rooms 3 kpa 2.9 kpa Section 205 table 205-1
Restrooms 2.5 kpa 2.4 kpa Section 205 table 205-1
Exit facilities 5 kpa 4.8 kpa Section 205 table 205-1
THIRD FLOOR - SECOND FLOOR
Classrooms 4 kpa 3.8 kpa Section 205 table 205-1
Restrooms 2.5 kpa 2.4 kpa Section 205 table 205-1
Exit facilities 5 kpa 4.8 kpa Section 205 table 205-1
GROUND FLOOR
Classrooms 5 kpa 4.8 kpa Section 205 table 205-1
Exit facilities 5 kpa 4.8 kpa Section 205 table 205-1
Restrooms 2.5 kpa 2.4 kpa Section 205 table 205-1
Storage (Light) 6.2 kpa 6 kpa Section 205 table 205-1
DING

SECTION

ction 204 table 204-1

ction 204 table 204-2


ction 204 table 204-2

ction 205 table 205-1

ction 204 table 204-1

ction 204 table 204-2


ction 204 table 204-2

ction 204 table 204-1


ction 204 table 204-1

ction 205 table 205-1


ction 205 table 205-1
ction 205 table 205-1

ction 205 table 205-1


ction 205 table 205-1
ction 205 table 205-1

ction 205 table 205-1


ction 205 table 205-1
ction 205 table 205-1
ction 205 table 205-1

S-ar putea să vă placă și