subject RETAINING WALL job ………… move n pick

CALCULATION SHEET ………………………….. job no ……………………….


computed PP date ……… 1/7/2013
checked ………………………….. page 1 of
pages

REF CALCULATION OUTPUT

DESIGN OF RETAINING WALL

DIMENTIONS

ret ht :- H= 7.15 m
depth :- D= 12 m
depth to water table :- Dw = 2.3 m
submerged depth :- Dsub = 16.85 m
total ht :- H= 19.2 m

soil report wall tkness:- 300 mm


Base tkness 0 mm

d wall :- 225 mm
d Base :- 0 mm

DATA
soil density :- ysoil = 18 kN/m3
saturated soil density :- ysat = 21 kN/m3
density of concrete :- ycon = 24 kN/m3
water density :- yw = 9.81 kN/m3
friction angle :- q= 30 deg
coeff. of active pressure :- ka = 0.33
surcharge :- q= 100 kN/m2
water ht. :- Hw= 16.85 m

loads on wall
Active Forces Force Ht. from base BM
kN/ m run m kNm
Force due to soil:- F1 = 1/2*kaysoilh2 = 15.7 17.617 276.78
Force due to submerged soil:- F2 = kaysoilh*Dsub = 230.20 8.425 1939.47
Force due to submerged soil:- F3 = 1/2*kaysubh2 = 524.22 5.617 2944.37
Force due to surcharge:- F4 = kaqh = 631.95 9.575 6050.92
Force due to water:- Fwa = ywh = 1392.64 5.617 7821.99
19033.54

GIVE
moment :- MT = 0 kNm
Mmax (ser)= 26646.96 kNm
Mmax (ult)= 39970.44 kNm
subject RETAINING WALL job …………………………..
CALCULATION SHEET ………………………….. job no ……………………….
computed PP date …………………………..
checked ………………………….. page of
pages

REF CALCULATION OUTPUT

U1
Mmax (ult)= 39970.44 kNm
M/bd2 = 789.54
GIVE p= 0.130
As = 293 mm2

S1
Mmax (ser)= 26646.96 kNm
M/bd =2
526.36
GIVE p= 0.0020
As = 450 mm2

S3
GIVE dia. of thermal r/f :- 10 mm
P= 0.0034
As = 503 mm2