Sunteți pe pagina 1din 3

WATER APPLICATION VALUE ENGINE

DOW WATER & PROCESS SOLUTIONS

RO Summary Report
RO System Flow Diagram

# Description Flow TDS Pressure


(m³/h) (mg/L) (bar)
1 Raw Feed to Pump 17.14 2,051 0.00
2 Net Feed to Pass 1 17.13 2,052 11.04
4 Total Concentrate from Pass 1 5.14 6,745 9.11
6 Total Permeate from Pass 1 12.00 36.85 0.00

RO System Overview
Total # of Trains 1 Online = 1 Standby = 0 RO Recovery 70.00 %
System Flow Rate (m³/h) Net Feed = 17.14 Net Product = 12.00

Pass Pass 1
Stream Name Stream 1
Water Type Well Water (SDI < 3)
Number of Elements 12
Total Active Area (m²) 445.93
Feed Flow per Pass (m³/h) 17.13
&ĞĞĚd^࣊ (mg/L) 2,052
Feed Pressure (bar) 11.04
Flow Factor 0.85
Permeate Flow per Pass (m³/h) 12.00
Pass Average flux (LMH) 26.9
WĞƌŵĞĂƚĞd^࣊ (mg/L) 36.85
Pass Recovery 70.1 %
Average NDP (bar) 7.67
Specific Energy (kWh/m³) 0.55
Temperature (°C) 30.0
pH 7.57
Chemical Dose
RO System Recovery 70.0 %
Net RO System Recovery 70.0%
Footnotes:
࣊dŽƚĂůŝƐƐŽůǀĞĚ^ŽůŝĚƐŝŶĐůƵĚĞƐŝŽŶƐ͕^ŝKЇand B(OH)Ј͘It does not include NHЈand COЇ

Project Name: Untitled Created: 08/03/2018 Page 1 of 3


WATER APPLICATION VALUE ENGINE
DOW WATER & PROCESS SOLUTIONS

RO Flow Table (Stage Level) - Pass 1


Feed Concentrate Permeate
Stage Elements #PV #Els Feed Recirc Feed Boost Conc Conc Press Perm Avg Flux Perm Perm
per Flow Flow Press Press Flow Press Drop Flow Press TDS
PV
PV (m³/h) (m³/h) (bar) (bar) (m³/h) (bar) (bar) (m³/h) (LMH) (bar) (mg/L)
1 BW30-400 2 4 17.13 0.00 10.73 0.00 8.31 10.05 0.68 8.83 29.7 0.00 26.36
2 BW30-400 1 4 8.31 0.00 9.85 0.00 5.14 9.11 0.73 3.17 21.4 0.00 66.05

RO Solute Concentrations - Pass 1


Concentrations (mg/L as ion)
Concentrate Permeate
Feed Stage1 Stage2 Stage1 Stage2 Total

NHЉЀ 0.00 0.00 0.00 0.00 0.00 0.00


<Ѐ 8.90 18.21 29.23 0.13 0.35 0.19
EĂЀ 419.00 856.46 1,374 7.07 17.86 9.93
DŐЀ² 106.00 217.82 351.11 0.71 1.75 0.98
ĂЀ² 128.00 263.06 424.05 0.83 2.08 1.16
^ƌЀ² 0.00 0.00 0.00 0.00 0.00 0.00
ĂЀ² 0.00 0.00 0.00 0.00 0.00 0.00
COЈЁ² 1.19 4.98 11.57 0.00 0.00 0.00
HCOЈЁ 206.02 416.17 660.72 3.38 8.22 4.66
NOЈЁ 28.20 55.49 86.01 2.51 6.00 3.43
ůЁ 767.00 1,571 2,525 9.68 24.74 13.67
&Ё 0.00 0.00 0.00 0.00 0.00 0.00
SOЉЁ² 387.00 795.82 1,284 2.04 5.04 2.83
SiOЇ 0.00 0.00 0.00 0.00 0.00 0.00
Boron 0.00 0.00 0.00 0.00 0.00 0.00
COЇ 5.50 6.96 9.16 5.82 7.52 6.27
d^࣊ 2,051 4,199 6,745 26.36 66.05 36.85
pH 7.57 7.72 7.75 5.94 6.19 6.04
Footnotes:
࣊dŽƚĂůŝƐƐŽůǀĞĚ^ŽůŝĚƐŝŶĐůƵĚĞƐŝŽŶƐ͕^ŝKЇand B(OH)Ј͘It does not include NHЈand COЇ

RO Design Warnings
Design Warning Limit Value Pass Stage Element Product
Element Recovery > Maximum Limit (%) 19.00 19.30 1 1 4 BW30-400

Project Name: Untitled Created: 08/03/2018 Page 2 of 3


WATER APPLICATION VALUE ENGINE
DOW WATER & PROCESS SOLUTIONS

RO Flow Table (Element Level) - Pass 1


Stage Element Element Name Recovery Feed Flow Feed Press Feed TDS Conc Flow Perm Flow Perm Flux Perm TDS
(%) (m³/h) (bar) (mg/L) (m³/h) (m³/h) (LMH) (mg/L)
1 1 BW30-400 14.07 8.57 10.73 2,052 7.36 1.21 32.4 17.18
1 2 BW30-400 15.50 7.36 10.49 2,385 6.22 1.14 30.7 22.10
1 3 BW30-400 17.24 6.22 10.30 2,818 5.15 1.07 28.9 29.08
1 4 BW30-400 19.30 5.15 10.16 3,398 4.16 0.99 26.7 39.46
2 1 BW30-400 10.91 8.31 9.85 4,199 7.41 0.91 24.4 48.32
2 2 BW30-400 11.23 7.41 9.61 4,707 6.58 0.83 22.4 59.09
2 3 BW30-400 11.50 6.58 9.42 5,294 5.82 0.76 20.3 72.84
2 4 BW30-400 11.66 5.82 9.25 5,970 5.14 0.68 18.3 90.69

Footnotes:
࣊dŽƚĂůŝƐƐŽůǀĞĚ^ŽůŝĚƐŝŶĐůƵĚĞƐŝŽŶƐ͕^ŝKЇand B(OH)Ј͘It does not include NHЈand COЇ

RO Solubility Warnings
Warning Pass No
Langelier Saturation Index > 0 1
Anti-scalants may be required. Consult your anti-scalant manufacturer for dosing and maximum allowable system recovery. 1

RO Chemical Adjustments
Pass 1 ZKϭ॰ࣞ
Feed Pass Conc

pH 7.57 7.75
Langelier Saturation Index 0.46 1.64
Stiff & Davis Stability Index 0.52 1.24
d^࣊;ŵŐͬůͿ 2,051 6,745
Ionic Strength (molal) 0.05 0.15
HCOЈЁ;ŵŐͬ>Ϳ 206.02 660.72
COЇ(mg/l) 5.50 9.16
COЈЁ² (mg/L) 1.19 11.57
CaSOЉ;йsaturation) 7.12 36.94
BaSOЉ;йsaturation) 0.00 0.00
SrSOЉ;йsaturation) 0.00 0.00
CaFЇ;йsaturation) 0.00 0.00
SiOЇ;йsaturation) 0.00 0.00
Mg(OH)Ї;йsaturation) 0.02 0.24

Footnotes:
࣊dŽƚĂůŝƐƐŽůǀĞĚ^ŽůŝĚƐŝŶĐůƵĚĞƐŝŽŶƐ͕^ŝKЇand B(OH)Ј͘It does not include NHЈand COЇ

Information provided is offered in good faith, but without guarantees. Users of such information assume all risk and liability and expressly release The
Dow Chemical Company and its subsidiaries, officers and agents from any and all liability. Because use conditions and applicable laws may differ from
one location to another and may change with time, users of information set forth herein or generated during use of WAVE are responsible for
determining suitability of the information. Neither The Dow Chemical Company nor its subsidiaries assume any liability for results obtained or damages
incurred from the use of information provided and TO THE FULLEST EXTENT PERMITTED BY LAW, EXPRESSLY DISCLAIM ALL WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Users will not export or re-export any information
or technology received from The Dow Chemical Company or its subsidiaries, or the direct products or designs based upon such information or technology
in violation of the export-control or customs laws or regulations of any country, including those of the United States of America.

Project Name: Untitled Created: 08/03/2018 Page 3 of 3

S-ar putea să vă placă și