This document contains a list of fault codes for the RBS 6000, divided into two classes:
Class 1A faults include resets from automatic recovery, power on, switches, or watchdog failures as well as faults involving timing units, corrupted databases, hardware and software inconsistencies, and high temperatures.
Class 2A faults involve issues like exceeded VSWR limits, diversity and timing bus faults, missing loadfiles, sensor faults, high temperatures, low voltages, incompatible hardware, and lost communication between components. Several faults indicate degraded performance or loss of service due to environmental conditions.
This document contains a list of fault codes for the RBS 6000, divided into two classes:
Class 1A faults include resets from automatic recovery, power on, switches, or watchdog failures as well as faults involving timing units, corrupted databases, hardware and software inconsistencies, and high temperatures.
Class 2A faults involve issues like exceeded VSWR limits, diversity and timing bus faults, missing loadfiles, sensor faults, high temperatures, low voltages, incompatible hardware, and lost communication between components. Several faults indicate degraded performance or loss of service due to environmental conditions.
This document contains a list of fault codes for the RBS 6000, divided into two classes:
Class 1A faults include resets from automatic recovery, power on, switches, or watchdog failures as well as faults involving timing units, corrupted databases, hardware and software inconsistencies, and high temperatures.
Class 2A faults involve issues like exceeded VSWR limits, diversity and timing bus faults, missing loadfiles, sensor faults, high temperatures, low voltages, incompatible hardware, and lost communication between components. Several faults indicate degraded performance or loss of service due to environmental conditions.
CF I1A:1 - Reset, Power On CF I1A:2 - Reset, Switch CF I1A:3 - Reset, Watchdog CF I1A:4 - Reset, SW Fault CF I1A:5 - Reset, RAM Fault CF I1A:6 - Reset, Internal Function Change CF I1A:8 - Timing Unit VCO Fault CF I1A:9 - Timing Bus Fault CF I1A:15 - IDB Corrupted CF I1A:16 - RU Database Corrupted CF I1A:17 - HW and IDB Inconsistent CF I1A:18 - Internal Configuration Failed CF I1A:19 - HW and SW Inconsistent CF I1A:21 - HW Fault CF I1A:22 - Air Time Counter Lost CF I1A:24 - Temperature Close to Destructive Limit
CF Internal Fault Map Class 2A
CF I2A:8 - VSWR Limits Exceeded
CF I2A:12 - RX Maxgain/Mingain Violated CF I2A:13 - Timing Unit VCO Ageing CF I2A:13 - Timing Unit VCO Ageing CF I2A:16 - Indoor Temp Out of Normal Conditional Range CF I2A:19 - Power and Climate System in Standalone Mode CF I2A:22 - Battery Backup Capacity Reduced CF I2A:23 - Climate Capacity Reduced CF I2A:24 - HW Fault CF I2A:25 - Loadfile Missing in DXU or ECU CF I2A:26 - Climate Sensor Fault CF I2A:30 - Bus Fault CF I2A:31 - High Frequency of Software Fault CF I2A:33 - RX Diversity Lost CF I2A:34 - Output Voltage Fault CF I2A:36 - RU Database Corrupted CF I2A:38 - Default Values Used CF I2A:41 - Lost Communication to TRU CF I2A:43 - Internal Configuration Failed CF I2A:45 - High Temperature CF I2A:46 - DB Parameter Fault CF I2A:47 - Antenna Hopping Failure CF I2A:48 - GPS Synch Fault CF I2A:50 - RBS Running on Battery CF I2A:51 - TMA Supervision/Communications Lost CF I2A:53 - HW and IDB Inconsistent CF I2A:54 - Timing Bus Fault CF I2A:57 - RX Path Imbalance CF I2A:58 – Disconnected CF I2A:59 - Operating Temperature Too High, Main Load CF I2A:60 - Operating Temperature Too High, Battery CF I2A:61 - Operating Temperature Too High, Capacity Reduced CF I2A:62 - Operating Temperature Too Low, Capacity Reduced CF I2A:63 - Operating Temperature Too High, No Service CF I2A:64 - Operating Temperature Too Low, Communication lost CF I2A:65 - Battery Voltage Too Low, Main Load Disconnected CF I2A:66 - Battery Voltage Too Low, Prio Load Disconnected CF I2A:67 - System Undervoltage CF I2A:68 - System Overvoltage CF I2A:69 - Cabinet Product Data Mismatch CF I2A:70 - Battery Missing CF I2A:71 - Low Battery Capacity CF I2A:72 - Software Load of RUS Failed CF I2A:73 - Degraded or Lost Communication to Radio Unit CF I2A:79 - Configuration Fault of CPRI System CF I2A:80 - Antenna System DC Power Supply Overloaded CF I2A:81 - Primary Node Disconnected CF I2A:82 - Radio Unit Incompatible CF I2A:83 - Radio Unit Connection Fault