Sunteți pe pagina 1din 16

Stream Name 1 Liquid Phase Vapour Phase

Vapour / Phase Fraction 0 1 0


Temperature [C] 34.3702980352 34.370298035 34.370298035
Pressure [kg/cm2] 1.7 1.7 1.7
Molar Flow [kgmole/h] 641.0442225831 641.04422258 0
Mass Flow [kg/h] 42000 42000 0
Std Ideal Liq Vol Flow [m3/h] 64.0631529141 64.063152914 0
Molar Enthalpy [kJ/kgmole] -23138.0348652046 -23138.03487 -46920.67582
Molar Entropy [kJ/kgmole-C] 68.994953754 68.994953754 141.03709763
Heat Flow [kJ/h] -14832503.5722655 -14832503.57 0
Liq Vol Flow @Std Cond [m3/h] 63.7921699885 63.792169988 0

Stream Name 1 Liquid Phase Vapour Phase


Molecular Weight 65.5181008118 65.518100812 62.864297164
Molar Density [kgmole/m3] 9.7325961491 9.7325961491 6.87E-02
Mass Density [kg/m3] 637.6612156581 637.66121566 4.316285559
Act. Volume Flow [m3/h] 65.8656963426 65.865696343 0
Mass Enthalpy [kJ/kg] -353.1548469587 -353.154847 -746.3803452
Mass Entropy [kJ/kg-C] 1.0530670593 1.0530670593 2.243516654
Heat Capacity [kJ/kgmole-C] 144.3968133479 144.39681335 105.47744853
Mass Heat Capacity [kJ/kg-C] 2.2039224513 2.2039224513 1.677859346
Lower Heating Value [kJ/kgmole] <empty> <empty> <empty>
Mass Lower Heating Value [kJ/kg] <empty> <empty> <empty>
Phase Fraction [Vol. Basis] <empty> 1 <empty>
Phase Fraction [Mass Basis] 2.12199579145934e-314 1 0
Partial Pressure of CO2 [kg/cm2] 0 <empty> <empty>
Cost Based on Flow [Cost/s] 0 0 0
Act. Gas Flow [ACT_m3/h] <empty> <empty> <empty>
Avg. Liq. Density [kgmole/m3] 10.0064419783 10.006441978 9.9991716231
Specific Heat [kJ/kgmole-C] 144.3968133479 144.39681335 105.47744853
Std. Gas Flow [STD_m3/h] 15157.1290940356 15157.129094 0
Std. Ideal Liq. Mass Density [kg/m3] 655.6030743021 655.6030743 628.59089631
Act. Liq. Flow [m3/s] 1.83E-02 1.83E-02 <empty>
Z Factor <empty> 6.70E-03 0.9496488801
Watson K 12.3631525702 12.36315257 12.758476723
User Property <empty> <empty> <empty>
Cp/(Cp - R) 1.061097646 1.061097646 1.0855707317
Cp/Cv 1.255902775 1.255902775 1.1030445991
Heat of Vap. [kJ/kgmole] 24644.043865874 24644.043866 24644.043866
Kinematic Viscosity [cSt] 0.28114925 0.28114925 1.6952588681
Liq. Mass Density (Std. Cond) [kg/m3] 658.3880123155 658.38801232 631.5368033
Liq. Vol. Flow (Std. Cond) [m3/h] 63.7921699885 63.792169988 0
Dados da simulação (HYSYS)
Temperatura [°C] 34.37029804
Massa específica [kg/m3] 637.6612157
Viscosidade Cinemática [St] 0.002811492 Viscosidade Cinemática [m²/s]
Viscosidade [kg/(ms)] 0.000179278 Viscosidade [cP]

Dados fornecidos
Pressão no vaso [kgf/cm²abs] 2.733
Pressão no vaso [kgf/cm²man] 1.7
g [m/s²] 9.8 Pela tabela de velocidade recomenda
Vazão mássica [Kg/h] 42000 viscosidade média (µ < 10 cp) têm-se
Low Level Liquid (LLL) [m] 0.2 recomendada na sucçção de 0,9 a 1,8
Velocidade recomendada sucção [m/s²] 1.8
Peso especifico [kg/(ms²)] 6249.079913
e (rugosidade) [m] 0.000046

Pela tabela de velocidade recome


viscosidade média (µ < 10 cp) têm
recomendada na descarga de 1,5

Dados do Isométrico
Sucção
Z flange de sucção [m] 0.3
Lreto da succção [m] 25.485
Z bomba/vaso [m] 7.28

Acidentes Quantidade L eq [m]


n° de curvas de 90° sucção 9 28.8
n° de curvas de 45° sucção 1
n° de reduções sucção 1 1.22
n° de Vál. Gave. sucção 1 1.98
n° de filtro em Y 1 3.05
n° de Tê sucção 1 3.05
Saida de vaso 1 5.49
Entrada da bomba 1 4
n° de Tê ramal 1 9.15
soma 56.74

Cálculo da vazão volumétrica


m
Q=
ρ
Q [m3/h] 65.86569634
Q [m3/s] 0.018296027

Cálculo da velocidade e do diâmentro da tubulação na sucção

3 in sch 40 De acordo com a norma

D=
√ 4Q
πv
Re=
ρ∗V∗D
μ
1°- Utilizando a velocidade recomendada

D calc [m] 0.113761995 D comercial [in]


D calc [in] 4.478818708 D comercial [m]
Vcal [m/s]
ΔP/100 m [kgf/cm²]

Cálculo da perda de carga no flange de sucção


2
Leq. Total [m] 82.225 L V
ΔP= f ∗ ∗
ΔP Total [kgf/cm²] 0.047341445 D 2∗g

Cálculo da pressão no flange de sucção


Pfs /peso especifico [m] 49.39732639
Pfs [kgf/cm²] 3.14987592

P coluna
Cálculo do Head sucção H= ( γ
+Z d + ΔPd

hs [m] 52.39681891

Cálculo do NPSHd sucção

NPSHd [m] 9.687015421

Cálculo do NPSHr sucção


NPSHr 8.187015421
2.8114924998633E-07
0.1792779725

cidade recomendada para óleos com


µ < 10 cp) têm-se a faixa de velocidade
ucçção de 0,9 a 1,8 m/s.

velocidade recomendada para óleos com


dia (µ < 10 cp) têm-se a faixa de velocidade
na descarga de 1,5 a 2,4 m/s.
0,05 Kgf/cm2 < ΔP/100<0,09 Kgf/cm2

2.228 e/D 0.000813


0.057 Re 1464135 f
7.2739296967 Re^0,9 354016.1
0.058 (e/D)/3,7 0.00022
f(0) 0.019001
f 0.018928
Leq [m] 82.425
ΔP/100 m [m] 0.902917

[ ]
1
f=
ε/ D 2,51
−2.log
( +
3,7 Re. f (0)0,5 )   / D 5,74 
2

f  0   0,25log  
v 2−v 2   3,7 Re 0, 9 
P vaso
luna
γ )(
+Z d + ΔPd −
γ
+Z s − ΔPs +) fd
2g
fs
+Z fd −Z fs
Iterações de Erro
0.018928 7.323E-05
0.018928 -4.68E-07
0.018928 3E-09
0.018928 -1.93E-11
0.018928 1.236E-13
0.018928 -7.95E-16

2
5,74 

Re 0, 9 
0
Dados da simulação (HYSYS)
Temperatura [°C] 34.37029804
Massa específica [kg/m3] 637.6612157
Viscosidade Cinemática [St] 0.002811492
Viscosidade [kg/(ms)] 0.000179278

Dados fornecidos
Pressão no vaso [kgf/cm²abs] 2.733
Pressão no vaso [kgf/cm²man] 1.7
g [m/s²] 9.8
Vazão mássica [Kg/h] 42000
Hight Level Liquid (HLL) [m] 0.2
Velocidade recomendada sucção [m/s²] 2.4
Peso especifico [kg/(ms²)] 6249.079913
e (rugosidade) [m] 0.000046
ΔP condensador [kgf/cm²] 0.144

Dados do Isométrico Descarga


Sucção
Z flange de descarga [m] 0.8
Lreto da descarga [m] 50
Z bomba/coluna [m] 42.945

Acidentes Quantidade L eq [m]


n° de curvas de 90° descarga 19 60.8
n° de reduções descarga 3 3.66
n° de Vál. Retenção 1 9
n° de Vál. Gave. Descarga 3 5.94
n° de Tê ramal descarga 2 10
Entrada de vaso 1 5.49
Saida da bomba 1 4
soma 98.89

Cálculo da vazão volumétrica


m
Q=
ρ
Q [m3/h] 65.86569634
Q [m3/s] 0.018296027

Cálculo da velocidade e do diâmentro da tubulação na descarga

1,5 in sch 40

D=
√ 4Q
πv

1°- Utilizando a velocidade recomendada

D calc [m] 0.098520778


D calc [in] 3.87877078

Cálculo da pressão da coluna

Obs: considerar a perda de carga na linha despresivel e a perda de carga do condensador é 2 pisi

Pcoluna [kgf/cm²] 2.877

Cálculo da perda de carga no flange de descarga


Leq. Total [m] 148.89 L V2
ΔP Total [kgf/cm²]
ΔP = f ∗ ∗
0.467768405 D 2∗g

Cálculo da pressão no flange de descarga


Pfd /peso especifico [m] 95.3986905
Pfd [kgf/cm²] 6.083204495

Cálculo do Head descarga


hd [m] 106.0987857
Viscosidade Cinemática [m²/s] 2.8114924998633E-07
Viscosidade [cP] 0.1792779725

Pela tabela de velocidade recomendada para óleos com


viscosidade média (µ < 10 cp) têm-se a faixa de velocidade
recomendada na sucçção de 0,9 a 1,8 m/s.

Pela tabela de velocidade recomendada para óleos com


viscosidade média (µ < 10 cp) têm-se a faixa de velocidade
recomendada na descarga de 1,5 a 2,4 m/s.
ção na descarga

De acordo com a norma

ρ∗V∗D
Re= 0,35 Kgf/cm2 < ΔP/100<0,50 Kgf/cm2
μ

D comercial [in] 1.61 e/D 0.001125


D comercial [m] 0.041 Re 2026144
Vcal [m/s] 13.9298910658 Re^0,9 474245.6
ΔP/100 m [kgf/cm²] 0.314 (e/D)/3,7 0.000304
f(0) 0.020406
f 0.020351
Leq [m] 149.09
ΔP/100 m [m] 4.926918
a do condensador é 2 pisi

L V2
ΔP = f ∗ ∗
D 2∗g


f  0   0,25log
P coluna P vaso v 2−v 2 
H= ( γ )(
+Z d + ΔPd −
γ
+Z s − ΔPs + )fd
2g
fs
+Z fd −Z fs
Iterações de Erro
f 0.020351 5.516E-05
0.020351 -1.89E-07
0.020351 6.518E-10
0.020351 -2.24E-12
0.020351 7.72E-15
0.020351 0

[ ]
1
f=
ε/ D 2,51
  / D
0   0,25log
  3,7

5,74
Re 0,9



2 −2.log
( +
3,7 Re. f (0)0,5 )
0
Calculo do Head da bomba
hd
179.2852
119.2669
98.97902
81.9197
81.74603
81.74324
Curva

Chart Title
140

120

100

80

60

40

20

0
0 20 40 60 80 100 120 140 160 180
hs H [m] Q [m3/s]
61.56579 117.7194 156.8231
54.71118 64.55571 97.23031
52.39682 46.5822 65.8657
50.4586 31.4611 6.58657
50.43997 31.30605 0.784115
50.43975 31.30349 0.015682