Sunteți pe pagina 1din 3

182 Chrysler

41TES/42RLE
2007 - Up Solenoid, Switch and VLP Circuit Test with the
“Relay Installed” andElectrical Circuit Test
the NGC “Disconnected”
KEY OFF 41TES/42LE 42RLE VLP Transmission Circuit Test
UNPLUG Typical Wire Diagram 87/A: Battery Power
30/B: Pins 16, 17 TCM &
85/C: Ground

NGC (2007 & Up) Pin 4 Solenoid Block


86/D: TCM Power

CONNECTOR Type 1 Type 2


B B
(GREEN FACE) (Wire Diagrams May Vary Per Model & Year, All Diagrams
Should Be Verified With Manufacturer When Possible) D C D C
Variable Line Pressure (VLP)
Pressure Control Solenoid
A
Line Pressure Sensor (Model Dependent)
HOT AT ALL TIMES A
Step 1: Key Off Unplug TCM C4 Green Face No Relay Has IPM
(NGC) Connector
FUSE
C1 Step 2: Jump 12 Volts to Pin 18 (with fused
INTERGRATED
link)
New POWER
Step 3: Check Voltage at Pins 1, 2, 6, 10, 11, FUSE MODULE
Generation C2
19, 22, 28, 29, 30, & 38 BLOCK
Computer
(single WARNING!
controller) C3 DO NOT PERFORM AN
AMPERAGE TEST ON
PRESSURE SWITCH CIRCUITS!
VOLTAGE TEST ONLY!
C4 C4
22 22 USE EXTREME
O/D PRESS SW
30 30 CAUTION WHEN
2/4 PRESS SW
29
BACK PROBING THIS
29
L/R PRESS SW LATE MODEL TYPE
1 1 CONNECTOR WITHOUT
O/D SOL CTRL
U/D SOL CTRL 2 2 USING A BREAKOUT
10 10
BOX THESE PINS ARE
L/R TCC SOL CTRL EASILY DAMAGED
6 6
2-4 SOL CTRL
11 11
PRESS SOL CTRL
38 38 PINS 1, 2, 6, 10, 11, 19, 22, 28, 29, 30 & 38
TRANS RELAY OUT
TRANS RELAY OUT
28 28 SHOULD HAVE 12 VOLTS
19 19
TRANS RELAY OUT
31 31
PRESS SEN SIG
18 18
TRANS RELAY CTR

JUMP PIN 12V TO PIN 18


(With Fusible Link)
Fusible
Link

DC Volts
Solenoids = approx. 1.5 - 2.5 ohms / 4 - 8 amps
+
12
AUTO DC

mV
+ + 6 4 5 6 7 8
V
RPM
mA
A PRESS TRANS U/D O/D 2-4 L/R TCC
mA
BATTERY SOLENOID CTRL RLY SOLENOID SOLENOID SOLENOID SOLENOID
V A
RELAY OUTPUT
OFF
POWER SOLENOID ASSEMBLY
V + PRESS
A mA COM RPM
C4 CONNECTOR PRESS SENSOR O/D 2-4 L/R
FACE (GREEN) SOLENOID SIGNAL PRESS SW PRESS SW PRESS SW
5 3 3 1 2

Source Voltage VLP CONNECTOR SOLENOID CONNECTOR


Amperage Check TRANSMISSION ASSEMBLY
Switch the meter to 10 1 SOLENOID CONNECTOR
DC Amps and move 19 11 VLP CONNECTOR
the red lead to the
amps jack. 28 20 5 1 3 2 1
(Solenoids Only) 38 29 1 2 3 4 5 6 10 9 8 7 6
Jump (w/fused link)
FACE VIEW
12 Volt/Amps FACE VIEW

© 2011 ATRA. All Rights Reserved.

Chrysler2011.indd 182 2/10/2014 9:46:27 AM


Chrysler 183

41TES/42RLE
2007 - Up Solenoid, Switch and VLP Circuit Test with the
“Relay Installed” and the NGC “Connected”
Electrical Circuit Test
ATTENTION: This computer can not be back probed, you must use Miller tool 8815
and 8815-1 the monitor the signal.
41TES/42LE 42RLE VLP Transmission Circuit Test
Typical Wire Diagram 87/A: Battery Power 85/C: Ground

Engine Running
30/B: Pins 16, 17 TCM &
86/D: TCM Power
(2007 & Up) Pin 4 Solenoid Block
Type 2
Type 1

New B B
(Wire Diagrams May Vary Per Model & Year, All Diagrams
Generation Should Be Verified With Manufacturer When Possible) D C D C
Computer
(single A
(Model Dependent)
controller) HOT AT ALL TIMES
No Relay Has IPM
A

(NGC) Variable Line Pressure (VLP)


C1
Pressure Control Solenoid FUSE

27
Line Pressure Sensor Test INTERGRATED
PRESS SEN 5 VOLTS POWER
MODULE
C2 Sensor Voltage Varies Pin 31 Conn C4:
PRESS SEN GRD
27 0.35V - 4.75V
C3

C4
22
O/D PRESS SW
2/4 PRESS SW 30
DC Volts
29
L/R PRESS SW
1
O/D SOL CTRL AUTO DC

U/D SOL CTRL 2 0.35 V

L/R TCC SOL CTRL 10

2-4 SOL CTRL 6 mV


+
V
11 RPM
mA
A
PRESS SOL CTRL mA
38 V A
TRANS RELAY OUT OFF
28
TRANS RELAY OUT V +
19 A mA COM RPM
TRANS RELAY OUT +
31
PRESS SEN SIG
18
TRANS RELAY CTR

+
BATTERY
USE EXTREME
CAUTION WHEN
BACK PROBING THIS
LATE MODEL TYPE
CONNECTOR WITHOUT
USING A BREAKOUT Solenoids = approx. 1.5 - 2.5 ohms / 4 - 8 amps
BOX THESE PINS ARE
EASILY DAMAGED

C4 CONNECTOR 1 5 4 5 6 7 8
WIRE (GREEN) NOT PRESS TRANS U/D O/D 2-4 L/R TCC
USED SOLENOID CTRL RLY SOLENOID SOLENOID SOLENOID SOLENOID
RELAY OUTPUT
POWER
SOLENOID ASSEMBLY
PRESS PRESS PRESS
PRESS SENSOR SENSOR SENSOR O/D 2-4 L/R
SOLENOID 5 VOLTS SIGNAL GROUND PRESS SW PRESS SW PRESS SW
1 10 6 2 3 4 3 1 2

11 19
VLP CONNECTOR SOLENOID CONNECTOR

20 28 TRANSMISSION ASSEMBLY
SOLENOID CONNECTOR
29 38
VLP CONNECTOR

5 1 3 2 1

1 2 3 4 5 6 10 9 8 7 6

FACE VIEW
FACE VIEW

© 2011 ATRA. All Rights Reserved.

Chrysler2011.indd 183 2/10/2014 9:46:27 AM


184 Chrysler

41TES/42RLE
Electrical Circuit Test
2007 - Up VLP Circuit Test with the NGC “Connected”
41TES/42LE 42RLE VLP Transmission Circuit Test
Typical Wire Diagram 87/A: Battery Power 85/C: Ground

Engine Running
30/B: Pins 16, 17 TCM &
86/D: TCM Power
(2007 & Up) Pin 4 Solenoid Block
Type 2
Type 1

New B B
(Wire Diagrams May Vary Per Model & Year, All Diagrams
Generation Should Be Verified With Manufacturer When Possible) D C D C
Computer
(single A
(Model Dependent)
controller) HOT AT ALL TIMES
No Relay Has IPM
A

(NGC) Variable Line Pressure (VLP)


C1
Pressure Control Solenoid FUSE

27
Line Pressure Sensor Test INTERGRATED
PRESS SEN 5 VOLTS POWER
MODULE
C2 Solenoid Duty Cycle Pin 11 Conn C4:
PRESS SEN GRD
27 On Min. Line: 62% = 60 psi.
Off Max. Line: 5% = 120-135 psi.
C3

C4
22
O/D PRESS SW
2/4 PRESS SW 30
Duty Cycle
29
L/R PRESS SW
1
O/D SOL CTRL AUTO DC

U/D SOL CTRL 2 62 %

L/R TCC SOL CTRL 10

2-4 SOL CTRL 6 mV


+
V
11 RPM
mA
A
PRESS SOL CTRL mA
38 V A
TRANS RELAY OUT OFF
28
TRANS RELAY OUT V +
19 A mA COM RPM
TRANS RELAY OUT +
31
PRESS SEN SIG
18
TRANS RELAY CTR

+
BATTERY
USE EXTREME
CAUTION WHEN
BACK PROBING THIS
LATE MODEL TYPE
CONNECTOR WITHOUT
USING A BREAKOUT Solenoids = approx. 1.5 - 2.5 ohms / 4 - 8 amps
BOX THESE PINS ARE
EASILY DAMAGED

C4 CONNECTOR 1 5 4 5 6 7 8
WIRE (GREEN) NOT PRESS TRANS U/D O/D 2-4 L/R TCC
USED SOLENOID CTRL RLY SOLENOID SOLENOID SOLENOID SOLENOID
RELAY OUTPUT
POWER
SOLENOID ASSEMBLY
PRESS PRESS PRESS
PRESS SENSOR SENSOR SENSOR O/D 2-4 L/R
SOLENOID 5 VOLTS SIGNAL GROUND PRESS SW PRESS SW PRESS SW
1 10 6 2 3 4 3 1 2

11 19
VLP CONNECTOR SOLENOID CONNECTOR

20 28 TRANSMISSION ASSEMBLY
SOLENOID CONNECTOR
29 38
VLP CONNECTOR

5 1 3 2 1

1 2 3 4 5 6 10 9 8 7 6

FACE VIEW
FACE VIEW

© 2011 ATRA. All Rights Reserved.

Chrysler2011.indd 184 2/10/2014 9:46:28 AM

S-ar putea să vă placă și