Output Tube Bias Adjustment position, and for low fan speed move

both tabs to the downward position. For


As shipped from the factory, the output
maximum cooling and extended tube
‘bias’ adjustments are set for a nominal
life, use the highest fan speed possible.
65mA per KT120 tube. Under these idle
Be sure to first turn off and unplug the
conditions the tubes are each
Reference 150 from its power
dissipating approximately 27 watts of
their 60 watt rating. This point of receptacle before unscrewing the top
operation provides ‘enriched’ Class AB1, cover to access the switch. Refasten the
and will satisfy the most critical listener. top cover before resuming operation.
For best results, operate and adjust the Do not operate the Reference 150 with
Reference150 at 120VAC. Adjustment fans disconnected or if one or both fans
must be made under zero-signal should stop running.
conditions after at least 15-20 minutes of
Hour Meter
uninterrupted stabilization time.
An LCD hour meter of elapsed tube
A digital voltmeter capable of accurate
operating time can be viewed through
measurements with 0.lmVDC resolution is
the top cover near the front, mounted
preferred for accurate adjustment (must
on the right main circuit board. This
have 31/2 digit display). Use the plastic
displays accumulated hours of vacuum
alignment tool provided to make the
tube service life. If the amplifier is
adjustment. The measurement points are
unplugged from A.C. supply, total
yellow and black banana test jacks next
accumulated hours are retained. May
to each output tube. Adjust the ‘bias’
be reset by qualified technician.
for a voltage reading of 65mVDC (.065
Contact Audio Research Customer
Volt DC) at the blue bias pot for one of
Service for more information about reset
each output tube pair as follows, noting
procedure.
the voltage setting of the larger V
number tube in each pair is slaved to Servicing
the adjustment setting of its lower V Because of its careful design and
number companion tube: Adjust V5 for exacting standards of manufacture,
65mVDC and measure its companion your Reference 150 amplifier should
tube V7 to verify a reading of 57 to normally require only minimal service to
73mVDC. Repeat procedure by
maintain its high level of performance.
adjusting and measuring V9 to read
Caution: The Reference 150 amplifier
65mVDC and verify V11 reads 57-
contains sufficient levels of voltage and
73mVDC; adjust and measure V6 to
current to be lethal. Do not tamper with
read 65mVDC and verify V8 reads 57-
a component or part inside the unit.
73mVDC, and finally adjust and measure Even with the power turned off, a
V10 to read 65mVDC and verify that V12 charge remains in the energy storage
reads 57-73 mVDC. capacitors for some time. Refer any
needed service to your authorized
Cooling Fan Speed Audio Research dealer or other qualified
Adjustment technician. Additional questions
The two D.C. cooling fans located at the regarding the operation, maintenance
rear of the Reference 150 are adjustable or servicing of your amplifier may be
in speed. Locate the red colored referred to the Customer Service
dipswitch under the top cover at the top Department of Audio Research
near the center of the back panel. For Corporation at 763.577.9700 (CST). When
highest fan speed move both white tabs ordering a service manual from Audio
on the red dip switch to the upward Research or an authorized dealer, be
position; for medium fan speed move sure to identify the serial number on your
either one of the tabs to the downward amplifier.

(! !