The “Juschem Power Plant Chemistry Information Management System” (J-PPCIMS ) is a web-based,
multi-user/role, multi location commercial software that helps power plant chemistry to track data and
performance starting from
• Raw water,
• Water Treatment Plant,
• Effluent Treatment,
• Reverse Osmosis data and analytics,
• steam-water cycle Chemistry,
• coal as received and as fired analysis
• Oil analysis
Manage samples ID and provide up to the minute information to the users and Managers. The software is
designed to comply NABL standards (not editable by general users).
It keep record from sample inward up to dispatch. Provide report, exports in excel. Audits made easy.
“Juschem Power Plant Chemistry Information Management System” (J-PPCIMS )
ELECTRICAL
SWITCH POWER TO
CHIMNEY YARD CONSUMERS
COAL MILL
CONDENSER
FEED WATER
HEATERS CW COOLING
COAL BUNKER
PUMP TOWER
CEP
COAL YARD
7 7 May 2019
Data Entry, view and reports are available
for:
• Steam water cycle – up to 16 units
(Complete lab analysis and SWAS report
can be entered including CPU)
• Cooling Water Chemistry and condenser
report
• Water Treatment plant water chemistry
report including raw water, clarified water,
Filter(s), DM Water Balance, ETP
Parameters, RO monitoring data
•Daily Chemistry data – It will come as a
daily report
•Coal Analysis Data (“as received”, “as
fired”, bulk density and DMR)
• Lube Oil Analysis Report
Data Entry…
Click
Data Entry…
Click to add
new data
New Sheet will open
for data entry,
chemist shall enter
the data in here
After entry, he
should check for Data once saved cannot be changed
wrong entry
if ok the press Save
manually
Data will be saved in rows and columns and chemist can see the data
Then Chemist can go back and either enter for other unit or opt for other
entries viz. cooling water, water treatment plant, coal analysis, oil analysis
etc
Includes: Includes: Includes: This space is kept
•pH, Sp. Cond, CC, •pH, Sp. Cond, TH, •DM Water prod. for daily report
Silica, Iron, Sodium CaH, MgH, Cons.(Consumption configuration,
of all sample points Chlorides, turbidity, by main plant, by DM Includes:
customizable as
i.e. feed, FRC, Zn, PO4 of CW plant internal use, •ADB and ARB coal
analysis data for per manager or
boiler/separator, and MU consumption by CPU
main steam, separately) proximate and GCV of senior
condensate, CPU •Also contains the “as received management
condenser data and •ETP flow and coal(rake/truck) requirement
individual and
tower temperature chemistry
common •Includes bulk density
data
•RO monitoring data data
•Includes mass and data fouling •Include ADB and ARB
Balance profile coal analysis data of
as fired coal (bunker)
Put the date range in search and get all the data for the range instantly
Value addition by providing:
Entry-view-reports of:
• Daily cooling water analysis details
✓ Data View (dataview) can only view data – This will be CCR, Operations or any authorized
person
✓ Manager (manager) can enter, view data, edit data (optional), run reports and export
reports) – This will be HOD Operations and HOD Chemistry
100
103
107
110
113
116
119
123
126
130
133
136
139
142
145
148
151
154
157
160
163
166
0
24
45
50
53
57
66
68
70
74
77
80
82
85
88
91
94
97
CEP O/L Sodium ppb Expon. (CEP O/L Sodium ppb)
100
103
107
110
113
116
119
123
126
130
133
136
139
142
145
148
151
154
157
160
163
166
0
24
45
50
53
57
66
68
70
74
77
80
82
85
88
91
94
97
CPU O/L Sodium ppb CPU O/L CC µS/cm CEP O/L CC µS/cm
Expon. (CPU O/L Sodium ppb) Expon. (CPU O/L CC µS/cm) Expon. (CEP O/L CC µS/cm)
CT Trend Graph 1 (PH / Alkalinity & RSI)
Relationship between pH, Alkalinity & SI of CW
8.5 335
285
8
235
7.5
185
7
135
6.5
85
6 35
22
23
pH
7.3
7.4
7.5
7.6
7.7
7.8
7.9
8.2
8.1
8
01-Dec-09
03-Dec-09
05-Dec-09
07-Dec-09
09-Dec-09
11-Dec-09
13-Dec-09
15-Dec-09
17-Dec-09
19-Dec-09
21-Dec-09
23-Dec-09
25-Dec-09
pH
27-Dec-09
29-Dec-09
31-Dec-09
02-Jan-10
04-Jan-10
COC on Mg-H.
06-Jan-10
08-Jan-10
10-Jan-10
R.S.I
12-Jan-10
14-Jan-10
Relationship between pH, COC & SI
16-Jan-10
18-Jan-10
20-Jan-10
22-Jan-10
24-Jan-10
26-Jan-10
Linear (COC on Mg-H.)
28-Jan-10
30-Jan-10
CT Trend Graph 2 (PH , CoC & RSI)
01-Feb-10
03-Feb-10
05-Feb-10
07-Feb-10
09-Feb-10
1.50
2.50
3.50
4.50
5.50
7.50
8.50
9.50
6.50
COC
24
6.50
6.70
6.90
7.10
7.30
7.70
7.90
8.10
8.30
8.50
7.50
01-Dec-09
03-Dec-09
05-Dec-09
07-Dec-09
09-Dec-09
11-Dec-09
13-Dec-09
15-Dec-09
17-Dec-09
19-Dec-09
21-Dec-09
23-Dec-09
25-Dec-09
27-Dec-09
R.S.I
29-Dec-09
31-Dec-09
02-Jan-10
04-Jan-10
06-Jan-10
08-Jan-10
Relationship between SI & COC
COC on Mg-H.
10-Jan-10
12-Jan-10
14-Jan-10
CT Trend Graph 5 (RSI & CoC)
16-Jan-10
18-Jan-10
20-Jan-10
22-Jan-10
24-Jan-10
26-Jan-10
28-Jan-10
30-Jan-10
1.50
2.00
2.50
3.00
4.00
5.00
5.50
3.50
4.50
25
8.9
6.9
10.9
12.9
14.9
16.9
18.9
20.9
22.9
24.9
01-Dec-09
03-Dec-09
05-Dec-09
07-Dec-09
09-Dec-09
11-Dec-09
13-Dec-09
DRY BULB
15-Dec-09
17-Dec-09
19-Dec-09
21-Dec-09
WET BULB
23-Dec-09
25-Dec-09
27-Dec-09
APPROACH
29-Dec-09
31-Dec-09
02-Jan-10
04-Jan-10
06-Jan-10
TOWER PERFORMANCE % 08-Jan-10
10-Jan-10
12-Jan-10
14-Jan-10
16-Jan-10
Relationship between Dry Bulb, Wet Bulb, Tower Performance & Approach
18-Jan-10
Linear (DRY BULB)
20-Jan-10
22-Jan-10
24-Jan-10
26-Jan-10
28-Jan-10
Linear (WET BULB)
30-Jan-10
01-Feb-10
Process Trend Graph 1 (Dry / Wet Bulb, Tower Perf & Approach)
03-Feb-10
40
45
50
55
60
35
Thank you for decision of
Installing Juschem Tools!