DISCRIMINATOR CLEARANCE PROCEDURE
FOR INTERNAL USE ONLY 2 (4)
DISCRIMINATOR CLEARANCE
PROCEDURE
A) Discriminator clearance Steps
ZDDS:;
ZL:2
ZLE:2,EXODUSGX
2
D:1,DEAD
After performing the above, ensure that all are 0000 except for “Windows currently in use”, by
using the following commands and exit:
S:1
S:2
S:3
S:4
SAMPLE OUTPUT
*************************************
Windows currently in use = 0001
Last window written to disk = 0000
Number of records in the que = 0000
Amount of bytes used = 0000
Identifier of the first record = 0000
Identifier of the last record = 0000
Last ULA record written = 0000
*************************************
Now, delete the Dissiminator Extension, using the command “L:2” and exit the service terminal
using “ZE”.
FOR INTERNAL USE ONLY 3 (4)
Please check ZEEK (it should be clear) and if still problem exists please restart
below given process on OMU as well as both active MCMU's and check.
D) Restart Process in OMU
ZDDS:OMU;
0-MAN>ZOKR:1CF
0-MAN>ZOKR:6B2
0-MAN>ZOKR:21F
0-MAN>ZE
ZQDI;
Lock CMISE applications
ZQDG:BSC938784A,UNL;
ZQDG:BSC938784EHA,UNL;
ZQDG:OMC000000D1,UNL;
ZQDG:OMC000000BP,UNL;
Now put this MCMU in SP-EX mode and restart the MCMU (C=DSK) and repeat the same for another
MCMU and check the ZEEK output using below commond.
<ZEEK;
output should be