DISCRIMINATOR CLEARANCE PROCEDURE
FOR INTERNAL USE ONLY 2 (4)

Bharti FM-BSS 29-Dec-2011


Alok Gangwar

DISCRIMINATOR CLEARANCE

Discriminator clearance activity can be performed during below given scenario-


1) RNW Network Plan Database state is “INTERRUPTED BY SYSTEM”. Use ZEEK command to check the
same.

2) Sometimes when MO Upload getting failed.

MUST REMEMBER BEFOR ACTIVITY


1) Plan the activity during maintenance window with proper outage approval.
2) Remember to make a valid FALLBACK
3) Stop command Calendar and resume after completion of activity

PROCEDURE
A) Discriminator clearance Steps
ZDDS:;
ZL:2
ZLE:2,EXODUSGX
2
D:1,DEAD
After performing the above, ensure that all are 0000 except for “Windows currently in use”, by
using the following commands and exit:

S:1
S:2
S:3
S:4

SAMPLE OUTPUT
*************************************
Windows currently in use = 0001
Last window written to disk = 0000
Number of records in the que = 0000
Amount of bytes used = 0000
Identifier of the first record = 0000
Identifier of the last record = 0000
Last ULA record written = 0000
*************************************
Now, delete the Dissiminator Extension, using the command “L:2” and exit the service terminal
using “ZE”.
FOR INTERNAL USE ONLY 3 (4)

Bharti FM-BSS 29-Dec-2011


Alok Gangwar

B) Change plan database state to clear in active database (BSDATA)


ZDDS:;
ZLE:Q,DAEMONGX
ZQD:6390000,4505,19B
ZQM:412,T:00,XD5CEF,XD5CEF,XD5CEF

Wait for 5 min and then go to the next step

C) Change at last plan database state in plan database (PDDATA)


ZQD:BA6002A,4505,6AE
ZQM:231,T:00,XD5CEF,XD5CEF,XD5CEF

Now, Perform OMU restart from Disk( C= DSK)

Please check ZEEK (it should be clear) and if still problem exists please restart
below given process on OMU as well as both active MCMU's and check.
D) Restart Process in OMU
ZDDS:OMU;

0-MAN>ZOKR:1CF
0-MAN>ZOKR:6B2
0-MAN>ZOKR:21F
0-MAN>ZE

E) Restart Process in working MCMU


ZDDS:OMU;
0-MAN>ZOKR:1B5
0-MAN>ZOKR:1CF
0-MAN>ZOKR:6B2
0-MAN>ZOKR:21F
0-MAN>ZE
F) Restart CMISE applications

ZQDI;
Lock CMISE applications

ZQDG:BSC938784A,LOC; (change ‘C’ number of BSC, marked in red color)


ZQDG:BSC938784EHA,LOC;
ZQDG:OMC000000D1,LOC;
ZQDG:OMC000000BP,LOC;
FOR INTERNAL USE ONLY 4 (4)

Bharti FM-BSS 29-Dec-2011


Alok Gangwar

Unlock CMISE applications

ZQDG:BSC938784A,UNL;
ZQDG:BSC938784EHA,UNL;
ZQDG:OMC000000D1,UNL;
ZQDG:OMC000000BP,UNL;

G) Perform OMU code loading restart ZUSU:OMU:C=DSK;

Now put this MCMU in SP-EX mode and restart the MCMU (C=DSK) and repeat the same for another
MCMU and check the ZEEK output using below commond.

<ZEEK;
output should be

BSC3i BSC23JAY 2011-01-21 10:21:45

RADIO NETWORK PLAN DATABASE STATES IN BSC:

RNW PLAN DATABASE STATE ............................ CLEAR


RNW CONFIGURATION ID ............................... 2334
RNW PLAN CONFIGURATION ID .......................... 2334
RNW FALLBACK CONFIGURATION ID ...................... 2100