Sunteți pe pagina 1din 2

DATA SHEET-SHUT DOWN VALVES

TITLE ITEM/TAG No. DATA SHEET Doc. No.


SHUT DOWN VALVE 1019-DPP-ELE-DTS-003
PROJECT DESCRIPTION : PROJECT No PAGE REV
TWENTY 20 DIRIO CENTRAL PROVINCE POWER PLANT GAS PIPING of A
VENDOR PURCHASE ORDER No. REQUISITION No. SPECIFICATION No.

CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
Allara Energy A JOS 13-10-2019 NR/PKS/ANA ISSUED FOR IDC

CLIENT'S REF.
P.O. 0250
ORIGINATOR ORIG. DATE
JOS 13-Oct-19
UNITS:- Pressure bar g kg/cm2 g MPa g psig
o o
Temp C F
1 GENERAL 57 ACTUATOR - Motor Operated
2 Tag Number SDV-001 58 TYPE MOTOR OPERATED.
3 FLUID GAS 59 Make . TBA
4 SERVICE FUEL GAS 60 Model No VTA
5 LINE No 200-FG-001-6A1 61 SIZE VTA
6 l-lazardous Area Classification ZONE'1, Gr. llA, T3 62 lngress Protection / Explosion Protection IP 65 / EEx'd'
7 LINE SIZE AND SCHEDULE (mm) 200 NB API5L X52 8.18MM THK 63 MATERIAL VTA
8 PROCESS CONDITIONS 64 FIRE-SAFE Suitable for Zone 2 Group IIA, T3
9 DESIGN TEMPERATURE 57deg. C max
(-) 29 deg. C min 65 AIR FAILURE - SPRING TO : Not applicable
10 DESIGN PRESSURE 9 Mpa(g) / 90 barg 66 ACT ORIENTATION AXIAL
11 APPLICABLE CODES AND SPECIFICATIONS 67 HANDWHEEL TYPE YES, SIDE MOUNTED
12 DESIGN CODE API 6D / ASME B16.34 68 AVAILABLE AIR PR. MIN /MAX. NA
13 FIRE-SAFE API 6FA / BS 6755 69 BREAK TORQUE RUN TORQUE VTA VTA
14 SEAT LEAKAGE CLASS (MIN) TSO, Class V I 70 MAX TIME OPEN/CLOSE 1 sec per inch of valve size
15 VALVE 71 POSITION INDICATION (LOCAL) Required - Analog Type
16 TYPE VTA 72 POSITION INDICATION (REMOTE) Required, Fully Closed & Fully Open
17 DESIGN STANDARD API 6D / tSO 14313 73 Power Suppty / Power (kw) 415V, AC, 50 HZ / VTA
18 SIZE / RATING (in) NB 200 NB 600 # 74 ACCUMULATOR Not Applicable
19 FLANGE FACE FINISH SM 75 Action on Power Failure Fail to Close (EFSA by Vendor)
20 CONFIGURATION WN RF 76 Mdthod of Motor Starting / lnching Duty Integral, Direct-on-Line / Yes
21 MATERIAL BODY ASTM 216 /A 105N 77 ACTUATOR COLOUR CODE VTA
22 Ball / Disc / Gate Material ASTM LA 182 F316L 78 Motor Type / nsulation Class SQUIRREL CAGE INDUCTION / F
23 STEM/TRUNION A 182 F316L / 17-4 PH SS 79 Torque (Nm) / Nominal Current (Arnp VTA / VTA
24 TRUNION BEARING INCONEL 625
25 1 Max. Diff. Pressure for Actuator Size 8MPa(g)
26 2 ELECTRICAL CONNECTIONS
27 3 Signal & Control Cable EExd CABLE GLANDS
28 4 Power Cable EExd CABLE GLANDS
29 5
A 182 F316L + PTFE(VIRGIN
LIMIT SWITCHES
30 PRIMARY SEATiING REINFORCED) 6
31 PACKING VITON B / GF 7 TAG No. ZSC001 & ZSO 001
32 BOLT / NUT ASTM 4320 Gr L7M / A1 94 Gr 7M 8 TYPE NON-CONTACT,PROXIMITY
33 DESIGN Zero leak, Tight shut off 9 SWITCHBOX MNF/MODEL VTA
34 BODY CONSTRUCTION FULL WELDED BODY 10 SWITCH MFR/MODEL VTA
35 BREAK TORQUE VTA 11 ACTUATION POINTS FULLY CLOSED / FULLY OPEN
36 RUN TORQUE VTA 12 ENCLOSURE EEx'd', IP66
37 LIMIT STOPS YES 13 INTEGRAL TERMINAL BOX Yes
38 VALVE COLOUR CODE VTA 14
39 MFR TBA 15 AIR FILTER REGULATOR
40 MODEL VTA 16
41 ADDITIONAL INFORMATION 17
42 Fugitive Emission Tightness Class CLASS B 18
43 Leakase Classl TSO (AS PER ISO 5208 RATE 19
44 Fire Safe Desiqn IYES (API6FA) 20
45 LOCATION PIG LAUNCHER AREA 21
46 PNEUMATIC CONN. SIZE VTA 22
47 ALL CABLE ENTRIES ISO M20 23 SOLENOID VALVE
48 TUBING AND TUBING FITTINGS SWAGELOK DOUBLE FERRULE 24 TAG No.
49 COMPRESSION SS316 (Min Mo 25 QTY
50 CONTENT 2.5%) 26 TYPE
51 NACE MR-01-75 (WETTED PARTS) NO 27 POWER SUPPLY
52 ANTISTATIC VALVE CONSTRUCTION YES 28 ENCLOSURE
53 VALVE STEM SEALANT INJECTION YES 29 MFR & MODEL
54 EXTENDED BONNET NO 30 MANUAL RESET
55 31 MATERIAL BODY
56 32 INTEGRAL TERMINAL BOX
NOTES:
33 1. Valve and Limit Switches to be provided with individual st. stl. 316 tag plates with tag no. permanently inscribed.

34 2. Valve & Actuator to be painted suitable for outdoor installation in a high humidity and dusty environment.

35 3. Documentation required :- Hazardous Area Certificate, Ingress Protection Certificate, Functional Test Certificate, Fire Safe Certificate, Hydrotest Certificate,
36 4. Material Certificates , Operating & Maintenance Instructions & Spare Parts List

37 5. All mounting accessories (brackets, mounting plates, screws etc. to be SS316 or better.

38 6. Solenoid valves, if used, to be with manual reset of the safety type which prohibits reset without power supply.

39 7. Power supply for Proximity switches is 24 VDC non IS to be generated internally

40 8. Proximity swich shall be rated minimum for use in Zone 2, Gas Group IIB andTemperature Class T3

41 9. Power supply cable will be given directly at theproximity of the MOV. Vendor shall ensure to provide local ON/OFF PB along with LOCAL/REMOTE

42 selector in built in the MOV or as a separate EEXd rated box.

43 * VTA-- VENDOR TO PROVIDE INFORMATION

D:\Project\Dirio 2019_RG-\DIRIO Deliverables\IDC Internal\[1019-DPP-ELE-DTS-003 SDV Data sheet.xlsx]SDV-001

S-ar putea să vă placă și