Railway Power Supply Systems


Moscow
Electric train equipment for
EMU800 and TEMU2000 Auxiliary power system for
of Taiwan Railway Administration MTA New York City Transit
Traction system,
auxiliary power system and
Germany
train information system for
Line 1 of Wuhan Metro Group
Co., Ltd.

Bulk Substation for Taiwan High


Speed Rail Corporation

Thailand
Traction system,
Traction system, auxiliary power system
auxiliary power system and and air conditioning system
train information system for Scott-connected for IFE EMU2000 and
Tianjin Binhai Mass Transit transformers for EMU3000 Series
Development Co., Ltd. Western Dedicated
Freight Corridor
Electric train equipment for
LRTA Line No. 2

Auxiliary power system, train


information system and
air-conditioning system for LRTA
Air conditioning system for Line No. 1 Traction system for BCRTC,
Beijing Mass Transit Railway Vancouver
Corporation, Line No. 13
Traction system for
DC electric trains Traction system for DC electric trains
Electric locomotives
Auxiliary power system
Electric train equipment for Diesel electric locomotives
Train information system
Thai Purple Line Air-conditioning system Traction system,
Air conditioning system
auxiliary power system,
train information system
for Central

PCC, main transformer, Substation system for Central


traction motor for
HXD3G electric locomotive
AC electric train for ROCA line

Diesel electric locomotive DC traction power substation


for KTMB equipment
Air conditioning system

Traction motors for Line 1 of


Auxiliary power system for City Rail
Companhia do Metropolitano
Substation equipment for ROCA line de Sao Paulo

Traction system and


auxiliary power system
for Salvador CTS

PMSM Propulsion System for


C151 Refurbishment

Air conditioning system for C751B,


C151A and Changi Airport Sky Train

Auxiliary power system for Changi


Electric train equipment for Electric train equipment for Electric train equipment for Airport Sky Train and SBS-Transit
Cairo Metro Line 1 Cairo Metro Line 2 Cairo Metro Line 3 Sengkang-Punggol LRT

Headquarters (Kawasaki, Japan) Toshiba International Corporation (Houston, U.S.A.)


Motors, adjustable speed drives (inverters), UPSs, switchgears, transportation systems, etc.
Toshiba Transmission & Distribution Systems (India) Pvt. Ltd. (Telangana, India)
Convertor/inverter system, Auxiliary convertors, Train control and monitoring system, Control electronics
Fuchu Complex (Tokyo, Japan)
Electric locomotives, traction control equipment, auxiliary power supply equipment, Toshiba Transmission & Distribution Systems Asia Sdn. Bhd. (Petaling Jaya, Malaysia)
traction motor, train information system, ATC/ATS system, etc. MV Switchgears, EPC of Substations

Mie Operations (Mie, Japan)


Transformers, motor control centers
Hamakawasaki Operations (Kawasaki, Japan)
Transformers, switchgears, surge arresters Toshiba China Co., Ltd. (Dalian, China)
Kashiwazaki Operations (Kashiwazaki, Japan) Toshiba Electronic Components Taiwan Corporation (Taipei, Taiwan)
Rechargeable Battery Toshiba Asia Pacific Pte Ltd (Singapore)
Toshiba Carrier Corporation (Fuji, Japan) Toshiba India Private Ltd. (Gurgaon, India)
Air-conditioning systems
PT. Toshiba Asia Pacific Indonesia (Jakarta, Indonesia)
Dalian Toshiba Locomotive Electric Equipment Co., Ltd. (Dalian, China)
Drive systems for locomotives, DC train drive systems, Toshiba International Corporation Pty Ltd (Sydney, Australia)
auxiliary power supply, traction motor, train information system, etc.
Toshiba Africa (Pty) Ltd. (Sandton, South Africa)
Guangzhou Toshiba Baiyun Electrical Equipment Co., Ltd. (Guangzhou, China) Toshiba Rus LLC (Moscow, Russia)
MV Switchgears

Sales & Engineering Office


Toshiba Railway Europe GmbH (Kiel/Düsseldorf, Germany)
Hybrid Locomotive

Find out more about Toshiba transportation solutions on http://toshiba-railway.com

●The information contained herein is as of August 1, 2018.


●The information contained herein is subject to change without notice.
●The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringements of patents
or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TOSHIBA or others.
●TOSHIBA products should not be embedded to the downstream products which are prohibited to be produced and sold, under any law and regulations.
●TOSHIBA does not take any responsibility for incidental damage (including loss of business profit, business interruption, loss of business information, and other pecuniary damage)

arising out of the use or disability to use TOSHIBA products.


●The products described in this document may include products subject to the foreign exchange and foreign trade laws.

●The products described in this document may contain components made in the United States and subject to export control of the U.S. authorities. Diversion contrary to the U.S.

law is prohibited.

2018.08
1 Railway Power Supply Systems DC Electrification Systems Control Center
・Rectifier Transformer ・Supervisory Control And Data Acquisition (SCADA)
・Traction Rectifier
・Regenerative Inverter
Rail transport has been evaluated as an environment-friendly transportation system, helping to solve environmental ・DC Switchgear
・Protection Relay
pollution, energy resources shortage, and chronic traffic congestion problems in developing countries. ・HSVCB
Since Toshiba started manufacturing traction motor and propulsion systems in 1899, we have made continuous ・Package-Type DC Substation
・Traction Energy Storage System (TESS) with SCiB™
technological innovations which led to the creation of new transportation systems, including power supply
systems. We have now expanded our business to supply advanced technologies on a global scale.
In the pursuit of technological innovation, global environmental issues are important, and demand is high for the
creation of a new product value aimed at reducing environmental impact while ensuring safety and comfort.
We offer products and systems to support your organization’s activities aimed at protecting the environment,
thus contributing to the creation of a sustainable, eco-friendly society.

AC Electrification Systems Transmission Systems


・Traction Transformer ・Gas Insulated Switchgear (GIS)
・Auto-transformer ・Gas Insulated Transformer (GIT)
・Feeding Circuit Breaker ・Gas Circuit Breaker (GCB)
・Feeding Switchgear(GIS,C-GIS,SIS) ・Cubicle Type Gas Insulated Switchgear (C-GIS)
・Changeover Switch ・Solid Insulated Switchgear (SIS)
・Control / Relay Panel
・AC Feeding Protection Relay

1 2
2 System Integration
Route map Timetable Our long histor y of engineering
Toshiba has been continuously striving to provide customers with advanced, optimal solutions. We are able railway system projects has given
us extensive expertise in designing
to provide not only the latest environmentally-friendly products from all over the world but also consulting
railway power supply systems. Our in-
services like energy simulation and construction works as well. house simulator is able to calculate
various railway system conditions
w i t h re m a r k a b l e a c c u r a c y. O u r
Substation experienced engineers are also there
Voltage to provide consultation and offer
customer-oriented solutions.
Current

Power

Train

Example of Power Supply Simulation

Toshiba is able to supply transmission and distribution products from


Engineering
our bases all over the world, using our worldwide distributors to offer
customer-oriented solutions at a competitive price.

Procurement
& Manufacturing
Construction
Solid Insulated Switchgear

Taiwan High Speed Railway Project

Vegetable Oil Transformer

Traction Energy Storage System (TESS) with SCiB™

Having started in the transportation business in 1899, Toshiba has extensive experience in offering innovative railway system products. For In addition to supplying products, Toshiba also provides customers with FTK solutions. One representative example of our FTK, the Taiwan High
power supply systems, our current products such as the Solid Insulated Switchgear, Vegetable Oil Transformer and Traction Energy Storage Speed Railway, wherein Toshiba built and supplied essential products for railway electrification.
System (TESS) with SCiB™, are environment friendly solutions which contribute to a more sustainable environment.
3 4
3 Transmission Systems
3-1 Gas Insulated Switchgear (GIS)
Railway Power Supply equipment must be highly reliable and safe. In addition, today's equipment must The Gas Insulated Switchgear (GIS) is an integrated switchgear which uses SF6 insulation gas. It is used mainly in 72.5kV or higher
also be economically efficient to accommodate installation in limited space and in a short period of time. systems. Toshiba has a long history for developing and manufacturing GIS.
Therefore, Toshiba developed the highly reliable SF6 Gas Insulated Switchgear (GIS) which can simplify site
work and reduce land footprint by up to 92%. For the main transformer, Toshiba offers a non-flammable
Gas Insulated Transformer (GIT)
for a more compact substation
solution. As for Toshiba’s product
l i n e - u p fo r m i d d l e vo l t a g e
switchgears, we developed the
Cubicle t ype G as I nsulated
Switchgear (C-GIS) and SF6 gas
free Solid Insulated Switchgear
(SIS).

168kV GIS 170kV GIS

Ratings
P6 Features
P12上

Transmission Systems Rated Voltage [kV] 72.5 ~ 252 Rated Voltage [kV] 36 / 72
Rated Interrupting Current [kA] 25 ~ 63 Rated Bus Current [A] 1200
Rated Lightning Impulse Withstand Voltage [kV] 325 ~ 1050
•Rated
Compact Design
Breaking Current [kA] 16 / 25
Can be installed in indoor and underground substations
Rated Power Frequency Withstand Voltage [kV] 140 ~ 460 Lightning Impulse [kV] 200 / 350
Typical space for AIS+OIT Applicable Standards JEC / IEC
Rated Withstand Voltage
• Outdoor Compatibility
Power Frequency [kV] 70 / 140
2,236m2 Applicable
ProtectionStandards
against pollution JEC / IEC
OIT
• Safe Operation
Electrified parts are enclosed in the earthed tank
P13上
P7上
52m •Rated
LowVoltage
Maintenance
[kV] 42
GSR GSM / GSP Rated Current [A] 1200
OIT Rated Voltage [kV] 240 / 300 72 / 84 / 168 Between Main Circuit and Earth 200
Lightning
Method of Operation Hydraulic Motor Spring Rated Impulse [kV] Between Main Circuit Terminals 250
Safe Withstand
Tank Dead Tank Power Between Main Circuit and Earth 70 – 1mi
Using safe material Voltage
Lighting (LTO) Frequency [kV] Between Main Circuit Terminals 100 – 10m
Rated 900 / 1050 350 / 400 / 750
Impulse [kV]
Low Temperature High Effective
Withstand

Gas Insulated Transformer (GIT)


Operation Capacity Rated Short Time Withstand 12.5 – 2sec.
Voltage Power 200-265-200(1min)/
AIS 140 / 160 / 325
3-2
Current [kA]
FrequencyAttractive
Usable in extremely [kV] 250-330-250(1min)
features are realized by High amount of actual
cold enviroments
Applicable Standards
usable energy over
JEC / IEC wide range of SOC
using Lithium Titanate Oxide Mechanical 200,000 times
(-30˚C) Switching Lifetime
(LTO) in its anode Electrical 100,000 times
The Gas Insulated Transformer (GIT) uses SF 6 gas for insulation and cooling instead of mineral oil and is suitable for indoor and
underground substations. GIT development and manufacturing at Toshiba also has a long history.
P8
Rapid High P19上
16m Recharging Input & Output
Rated Voltage [kV] 24 36 40.5 72 84
Recharges Usable with Features
Rated Voltage [V] DC 750 , 1500
43m Rated
in approx. 6 minutes
Lightning Impulse [kV] 125 170 185 high current
350 400
Withstand Rated Current [A] 3000 , 4000
Long Life
Voltage Power Frequency [kV] 50 70 95 140 160 Rated Breaking Capacity [kA] 50 (at 3×106A / sec), 100 (at 10×10 6A / sec)
GIT Over 6,000 charge-
discharge630
cycles
/ 1250 / 1250 /
•Rated
Non-flammability
Short Time Current [kA] 50-1sec , 100-1sec
GIS Rated Current [A] 800 / 1250 SF6 gas isStandard
used instead of mineral oil,bealleviating
2000 2000 Applicable JIS (To developedthe
forneed
IEC)
for a fire fighting system. This also allows the installation in
Rated Short Time Withstand
25 / 31.5 the same room with the GIS for a more compact substation
11m Current [kA]
layout.
GIT Applicable Standard JEC / IEC / GB
• Non-explosive
P19下
No pressure relief device is needed.
Specifications Applicable equipments
• Compact Design Air Insulated type or
A compact solution with GIS and GIT Our GIS+GIT - Sample Layout MV Switchgear Unit 7.2 / 24 / 36kV
Conservator and pressure relief device are not required thus type
Solid Insulated
AIS : Air Insulated Swithgear 176m2 (8% of AIS + OIT land footprint) lowering the height to less than that of OITs.
TR : Epoxy Resin Molded D
OIT : Oil Insulated Transformer 12-Pulse Rectifier Unit Up to 2,000kW / Liquid Silicone
P10上 SR : Heat-pipe Self-coolin
GIS : Gas Insulated Switchgear
GIT : Gas Insulated Transformer Example of Scott Connected Transformer DC Switchgear Unit DC 600V, DC1500V HSCB or HSVCB
GIT Auxiliary Power DC 110V,
5 T-type Bushing Busbar Rated Voltage [kV] 220/27.5 x 2 ; 132/27.5 x 2 6 Battery
Lead Storage
Supply Unit AC 105V / 210V
ES EVT Cooling Type ONAN / ONAF / OFAF
Rated Power [MVA] 60 / 80 / 100
3-3 Gas Circuit Breaker (GCB) 3-5 Solid Insulated Switchgear (SIS)
Mineral Oil Liquid Silicone
Toshiba supplies Vegetable
many typesOil Epoxy Resin
of Gas Circuit Breakers (GCB) for 72kV or higher voltage. Solid Insulated Switchgear (SIS) utilizes high-performance epoxy resin independently developed as the insulating material for SIS.
Applicable for up to 6MW Rectifier
OIT This epoxy resisn provides remarkable improvement in strength, flexibility, heat-resistance and dielectric strength. With the use
∼ 77kV ∼ 35kV
Applicable for DC600V / 750V / 1500V / 3000V
of this material for switchgear insulation, size was reduced while maintaining the equipment's high reliability. Installation space
JEC / IEC
required for SIS is smaller than our conventional air-insulated switchgear. For the 24/36kV SIS, Balanced Magnetic Acutator (BMA)
for the VCB is utilized which further reduces the size and weight of the SIS without
P6 P12上compromising its performance.
52m
Rated Voltage [kV] OIT 72.5 ~ 252 Rated Voltage [kV] 36 / 72
Rated Interrupting Current [kA] 25 ~ 63 Rated Bus Current [A] 1200
Rated Lightning Impulse Withstand Voltage [kV] 325 ~ 1050 Rated Breaking Current [kA] Safe Busbar 16 / 25
P6 P12上 Rated Power Frequency Withstand Voltage [kV] 140 ~ 460 VDS Using safe
Lightning material[kV]
Impulse 200 / 350
P16上 Rated Withstand Voltage (LTO)
Applicable Standards JEC / IEC Operation
Low Temperature
Power Frequency [kV] 70 / 140
High Effec
Rated Voltage [kV] 72.5 ~ 252 Rated Voltage [kV] 36 / 72 Mechanism
Applicable Standards
Operation JEC / Capacit
IEC
Rated Interrupting Current [kA] 25 ~ 63 Rated Bus Current [A] AIS 1200 Cooling and Insulating Method Gas Mineral Oil Liquid Silicone Usable in extremely
Vegetable Oil Epoxy Resin
Attractive features are realized by High amount of
Rated Lightning Impulse Withstand Voltage [kV] 325 ~ 1050 Rated Breaking Current [kA] 16 / 25 Rated Power Protection
Applicable for up to 6MW Rectifier
cold enviroments usable energy
Relay (-30˚C)
using Lithium Titanate Oxide wide range of
Rated Power Frequency Withstand Voltage [kV] 140 ~ 460 Lightning Impulse [kV] 200 / 350 anode VD
Rated Withstand Voltage Primary ∼ 77kVP13上 (LTO) in
∼its35kV
Applicable Standards JEC / IEC Power Frequency [kV] 70 / 140 Rated Voltage
P7上
Secondary Applicable for DC600V / 750V / 1500V / 3000V
Applicable Standards JEC / IEC Rated Voltage [kV] 42
Applicable Standard GSR GSM / GSP JEC / IEC ES
Rated Current [A] 1200
240kV GCB 72kV GCB VCB
Rated Voltage [kV] 240 / 300 72 / 84 / 168 Between Main Circuit and Earth 200
Lightning
P13上 Method of Operation Hydraulic Motor Spring Rated Rapid Impulse [kV] High
Between Main Circuit Terminals 250
16mP16下
Ratings
P7上 Tank Dead Tank Recharging
Withstand
Voltage RechargesPower
Input & Ou
Main Cable
Between Main Circuit and Earth 70 – 1mi
Rated Voltage [kV] 42 Cooling Method Lighting Vertical heat-pipe self cooling Usable wit
GSR GSM / GSP Features • Easy Installation
Rated Current [A] 43m 1200 Rated
Rated Power Impulse [kV]
900 / 1050 350 / 400 / 750 in approx. 6 Frequency
minutes [kV] Between Main Circuit
CT Terminals 100
high –curre
10m
~ 6 MW
Rated Voltage [kV] 240 / 300 72 / 84 / 168 Withstand Rated Short Time Withstand Long Life
• Low NoiseBetween Main Circuit and Earth 200
Lightning Rated Voltage Power DC 600V 200-265-200(1min)/
/ 750V / 1500V
GIT 140 / 160 / 325 Current [kA]
12.5 – 2sec.
Over 6,000 charge-
Method of Operation Hydraulic Motor Spring Rated Impulse [kV] Between Main Circuit Terminals 250 Frequency [kV] 250-330-250(1min)
Withstand Applicable Standard JEC / IEC discharge cycles
1,000kW‐continuousTank
rating Dead Tank GIS
Applicable Standards JEC / IEC 24kV SIS Mechanical 200,000 times
ode Voltage Power Between Main Circuit and Earth 70 – 1min. Switching Lifetime
3,000kW‐1minute or 4,500kW-30seconds
Lighting Frequency [kV] Electrical 100,000 times
Rated 900 / 1050 350 / 400 / 750 Between Main Circuit Terminals 100 – 10min.
1,000kW‐continuous rating only Impulse [kV]
Withstand Rated Short Time Withstand 11m
Voltage Power 200-265-200(1min)/ 12.5 – 2sec. GIT
140 / 160 / 325 Current [kA]
Frequency [kV] 250-330-250(1min)
ke a selection for your operation )
8% output regulation Applicable Standards JEC / IEC Switching Lifetime
Mechanical 200,000 times Ratings
P8
Electrical 100,000 times P19上
ol
Rated Voltage [kV] 24 36 40.5 72 84 Features • SF6 gas-less due to epoxy-
Rated Voltage [V] DC 750 , 1500
Rated Lightning Impulse [kV] 125 170 185 350 400 resin coating
Cubicle Type Gas Insulated Switchgear (C-GIS) Withstand Rated Current [A] 3000 , 4000
* 2Bridge

3-4 Rated Breaking •Capacity


Compact Design
nfiguration by Transformer P8 Voltage Power Frequency [kV] 50 70 95 140 160 [kA] 50 (at 3×106A / sec), 100 (at 10×10 6A / sec)
P19上 P21 Rated Short Time Current [kA] 50-1sec , 100-1sec
1200FXF1US53(P) 630 / 1250 / 1250 /
Rated Voltage [kV] 24 36 40.5 72 84
Rated Current [A]
2000 2000
800 / 1250 • Outdoor Compatibility
Applicable Standard JIS (To be developed for IEC)
natural cooling type) Rated Voltage [V] DC 750 , 1500
* 2,900H The CubicleLightning
Rated Type Gas Insulated
Impulse [kV] Switchgear
125 170 (C-GIS)
185 is350an integrated
400 switchgearRated
which uses
Current [A]SF 6 3000 , 4000
Rated Short Time Withstand
Current [kA]
25 / 31.5 1,000kW‐continuous rating • Safe Operation
Withstand Regenerating Inverter mode
00W * 1,000D * 2,300H insulation gas. It is used mainly
Power Frequency [kV] in 36kV
50 to
70 84kV95systems.
140 Toshiba
160 spent many years developing Capacity 3,000kW‐1minute or 4,500kW-30seconds
0D * 2,500H
Voltage
and manufacturing high quality C-GIS. Vacuum circuit breakers (VCB) are used for
Rated Breaking Capacity [kA]
theShort
C-GIS.
50 (at 3×106A / sec), 100 (at 10×10 6A / sec) Applicable Standard JEC / IEC / GB • Low Maintenance
630 / 1250 / 1250 / Rated Time Current [kA] T-type Bushing
50-1sec , 100-1sec Busbar Powering Converter mode 1,000kW‐continuous rating only
Rated Current [A] 800 / 1250
2000 2000 Applicable Standard JIS (To be developed forES
IEC) EVT 1,500VDC
P19下 • High Reliability
Rated Short Time Withstand TT Output control mode (Make a selection for your operation ) Specifications Applicable equipments
25 / 31.5 DS Rated Input Voltage
Current [kA] -1) Load control: To 6% or 8% output regulation
Applicable Standard JEC / IEC / GB ES DS -2) Constant voltage control MV Switchgear Unit 7.2 / 24 / 36kV Air Insulated type or
VCB Solid Insulated type
Rated P8 の図
36 40.5 72 84 P19下 P13 の図 VCB Output Voltage
CHD
1,200VAC
170 185 350 400
Eco-Friendly Design
MainP10上
1Series * 2Parallel * 6Arm * 2Bridge
Circuit Configuration
Safe Design
12-Pulse Rectifier Unit Up to 2,000kW
TR : Epoxy Resin Molded D
/ Liquid Silicone
Specifications Applicable equipments ES Double bridge parallel configuration by Transformer
70 95 140 160 SR : Heat-pipe Self-coolin
CHD
Device IGBT (3,300V-1,200A) / MG1200FXF1US53(P)
30, 1250, 2500 630, 1250, 2000 800, 1250 800, 1250 MV Switchgear Unit 7.2 / 24 / 36kV Air Insulated type or
Example
CoolingofSystem
Scott Connected Transformer The Greenhouse Effect
C-GIStype) DC Switchgear Unit DC 600V, DC1500V HSCB or HSVCB
25, 31.5 25, 31.5 20, 25, 31.5 20, 25, 31.5
Solid Insulated type
ES Device
Sun
Rated Voltage [kV]
Heat-pipe in pure water (natural cooling
220/27.5 x 2* ;2,200D
Inverter-2,700W 132/27.5 x2
* 2,900H Auxiliary Power DC 110V, Lead Storage Battery
JEC / IEC DSResin Molded Dry
TR : Epoxy CT Supply Unit AC 105V / 210V
12-Pulse Rectifier Unit Up to 2,000kW / Liquid Silicone Cooling Type
Dimension ONAN
Control / ONAF
Panel / OFAF
of Inverter-800W * 1,000D * 2,300H
P10上 ES
SR : Heat-pipe Self-cooling Rated Power [MVA] 60 / 80 / 100 * 2,000D * 2,500H
DC Reacrtor-2,800W
CT
Example of Scott Connected Transformer DC Switchgear Unit DC 600V, DC1500V HSCB or HSVCB Overload 150% (15mins), 200% (5mins) @ONAN Rating
Connection Scott Atmo Zero SF6 5kg 0kg
Rated Voltage [kV] 220/27.5 x 2 ; 132/27.5 x 2
72kV C-GIS Cross-section
Auxiliary Power
Supply Unit
DC 110V, Lead Storage Battery
Applicable Standard IEC Green sph P13
Half Weight 1,900kg 850kg
Cooling Type ONAN / ONAF / OFAF
AC 105V / 210V
h ous er
Ratings
Rated Power [MVA]
新P7下 60 / 80 / 100
P7下 Note: JEC Standards is also applicable
e Ga
e 21F
Half Components
Distance Protection
2500pcs 1200pcs
51F Overcurrent Protection
Overload 150% (15mins), 200% (5mins) @ONAN Rating Rated Voltage [kV] 36 se 40.5 Protection Function
72 84
Rated Voltage [kV] Features • 21F
Compact Design s 37% Less Volume Voltage
27F 2.7m3Protection
1.7m3
27.5 Connection Scott 36 40.5 72 84 50F Lightning Impulse [kV] 170 185 350 400
P13 Rated Withstand Voltage 79 Automatic Reclose
Rated
1250
Withstand
Lightning Impulse [kV]
Applicable Standard IEC 170 185 350 400 • Outdoor Compatibility P10中 Power Frequency [kV] 70 95 140 160
250 Note: JEC
Voltage Power
Standards Frequency
is also applicable [kV] 70 95 140 160 21F
• Safe Operation
Distance Protection Rated Current [A] Earth
630, 1250, 2500 630, 1250, 2000 800, 1250 800, 1250
(Comparing with TOSHIBA products at 24kV)
95 630 / 630 / 51F Overcurrent Protection RatedExample ofWithstand
Short Time Roof-delta Connected
Current [kA] Transformer 25, 31.5 25, 31.5 20, 25, 31.5 20, 25, 31.5
800 / 800 / Protection Function
Rated Current [A] 1250 / 1250 / 27F Voltage Protection SIS BusbarJEC
Compartment
25
2500 2000
1250 1250 • Low Maintenance RatedStandards
Applicable Voltage [kV] 220kV / 60kV×2 / IEC
IEC 79 Automatic Reclose SFCooling
6 gas Type
is evaluated as the ONAN
most potent greenhouse gas and it SIS has an "Internal arc-free" feature which promotes safe
P10中
Rated Short Time Withstand
Current [kA]
25 /
31.5
25 /
31.5
20 / 25 / 20 / 25 /
31.5 31.5
• Easy Cable Withstand poses negative
Rated Power [MVA]effects in the
120environment. As part of Toshiba’s operation. Busbar and devices in each phase of the main
Example ofStandards
Applicable Roof-delta Connected Transformer JEC / IEC Voltage Test Overload
drive for the development of300%more2min
eco-friendly products, Toshiba circuit P11
are completely insulated with earthed layer of
Rated Voltage [kV] 220kV / 60kV×2 introduced
Connection a new material which possesses high dielectric strength.
Roof-delta Toshiba'sRated
unique epoxy
Voltage [kV] resin mold 27.5
coating.
Applicable Standard JEC
7 Cooling Type ONAN Rated Lightning 200 (to earth and across open8 contacts)
Note: IEC Standards is also applicable 新P7下Withstand
Rated Power [MVA] 120 新 P12 下 Impulse [kV] 220 (across isolating distance)
Voltage
Overload 300% 2min P11
P8

Rated Voltage [kV]


P7上 24 36 40.5 72 84
P8Rated Lightning Impulse [kV] 125 170 185 350 400
Withstand GSR GSM / GSP

4 AC Electrification Systems
Voltage Power
Rated Voltage [kV] Frequency [kV] 50
24024
/ 300 3670 95
40.572 / 84140 160
72 / 168 84
Method
Rated of Operation
Lightning 630 / 1250
Impulse [kV] Hydraulic
125 170/ 1250 / 350
185Motor Spring 400
Rated Current [A] 800 / 1250

AC Traction Transformer Withstand 2000 2000


P11 の図 P15 の図 Tank Dead Tank

4-1
Voltage Power Frequency
Rated Short Time Withstand [kV] 50 70 95 140 160
Lighting 25 / 31.5
Current [kA]
Rated 900630
/ 1050
/ 1250 / 1250350 / / 400 / 750
Rated CurrentImpulse
Withstand [A] [kV] 800 / 1250
Applicable Standard 2000 JEC 2000/ IEC / GB
Voltage Power 200-265-200(1min)/
Toshiba provides a highly-reliable and modernized AC electrification system which consists of elements AC Rated Short Time
feeding power for rolling stock is single-phase power. The AC feeding substation Withstand
Frequency [kV] should therefore convert
250-330-250(1min) 25 / the
140 / 160 / 325
31.5 commercial
Current [kA]
such as large capacity of traction transformers, single phase circuit breakers, surge arrestors, and AC 3-phase into AC single-phase. However in this case, it will cause threeStandards
Applicable phase voltage unbalance at the JEC /primary
IEC side. Scott
Applicable Standard JEC / IEC / GB
Connected and Roof-Delta Connected transformers are used for the AC traction transformer which can reduce the 3-phase
Power Source
changeover switches. Our products are designed with thesubstation
substation advance technology based on our long history
voltage unbalance induced in the primary side.
of development. It contributes to a safe, stable and cost-minimized system operation for a long term.
P8
Sectioning Post Transformer
Ratings
P10上
VS-A VS-B Rated Voltage [kV] 24 36 40.5 72 84
Example
Rated of Scott Connected
Lightning Transformer
Impulse [kV] 125 170 185 350 400
IGBT Withstand
Features • Toshiba can supply various types of transformers and propose the most suitable type of Regenerative
Inverter
P10上
Rated Voltage
Voltage
Escalator [kV] Frequency [kV]
Power
Lighting 220/27.5
50x 2 ; 132/27.5
70 x95
2 140 160
transformer according to customer specification such as voltage, capacity, loss, installation Cooling Type ONAN 630/ ONAF / OFAF
/ 1250 / 1250 /
Example
Rated of Scott
Current Connected Transformer
[A] Facility 800 / 1250
condition, etc. Traction Substation Passenger
Rated PowerStation
[MVA] 60 / 80 / 1002000 2000
Rated
Overload
Rated Voltage [kV]
Short Time Withstand 220/27.5 x 2 ; 132/27.5 x 2
150% (15mins), 200% (5mins) @ONAN Rating
• The changeover switches are used for the phase break point of high speed railway system. Cooling Type ONAN
25 / 31.5
Current
Connection[kA] Scott / ONAF / OFAF
Our product is designed for long time operation under the harsh conditions of high voltages Rated Power [MVA] 60
Applicable
Applicable Standard
Standard IEC/ 80 / 100 JEC / IEC / GB
and repeating surges. Overload 150% (15mins), 200% (5mins) @ONAN Rating
Note: JEC Standards is also applicable
• The control and relay panels supplied by Toshiba are designed with the advance digital Connection Scott
Decelerating / Regeneration by Brake Accelerating
Applicable / Powering
Standard IEC
technologies. They integrate all required functions such as protection, control and monitoring by
the intelligent digital relays, PLCs and the LAN connection network. Scott Connected Transformer
Note: JEC Standards is also applicable
P10中

Example of Roof-delta Connected Transformer


P9 の図 Ratings
P10中
P10上
Rated Voltage [kV] 220kV / 60kV×2
TOSHIBA's POWER SUPPLY SYSTEMS for AC Feeding Substation Cooling Type ONAN
Roof-delta
Example of Scott Connected
Connected Transformer
Transformer
Rated Power [MVA] 120
Rated Voltage [kV]
Overload 220kV / 60kV×2
220/27.5
300% 2min x 2 ; 132/27.5 x 2
Cooling Type ONAN / ONAF / OFAF
P13 の図 Connection
Rated PowerStandard
[MVA]
Roof-delta
120
Applicable 60
JEC/ 80 / 100
Overload
Overload
Note: IEC Standards is also applicable
300% 2min
150% (15mins), 200% (5mins) @ONAN Rating
Connection
TO POWER COMPANY 3 phase NETWORK Roof-delta
Scott
Applicable Standard
P10下 JEC
IEC
Note: IEC
JEC Standards
Standards isis also
also applicable
applicable
Power Company 161kV  3 Example of Autotransformer
27S1,27G1 27S2,27G2 Traction Transformer P10下
Rated Voltage [kV] 60/30
(Scott Connection) Type ONAN
Roof-delta Connected Transformer Example of Autotransformer
P10中
51S1,51G1 51S2,51G2
Rated Self Capacity [MVA] 10
Rated
PowerVoltage
Line [kV]
Capacity [MVA] 60/30
20 Transformer
Example of Roof-delta Connected
Solid Insulated Type
Overload ONAN
300% 2min

SF6 -Gas Insulated


87T1,51T1,50GT1
51GT1
87T2,51T2,50GT2
51GT2
Switchgear

4-2 Autotransformer Rated Voltage


Short Circuit
Cooling
Power
[kV]
Rated Self Capacity [MVA]
LineIntensity
Type
220kV
10 / 60kV×2
Can withstand thermally and mechanically
Capacity [MVA] ONAN
20
for 25 or 35 times of the rated current
Rated PowerStandard
Overload
Applicable [MVA] 120
300% 2min
JEC / IEC
Switchgear (GIS) Mtr1 Mtr2 Overload
Note: IEC Standards is also applicable
300% 2min
Can withstand thermally and mechanically
Short Circuitvoltage
Autotransformer is used for the AT Feeding System which reducesConnection
catenary Intensity drops and electro-magnetic interference. It is
51B1M 51B1T 51B2M 51B2T
Roof-delta
for 25 or 35 times of the rated current
50OT1T 50OT1M 50OT2T 50OT2T
designed with low impedance and to withstand the high short circuit current.
Applicable Standard JEC
JEC / IEC
OT1 OT2 Note: IEC Standards is also applicable

51OT1 51OT2T
Ratings
P10下

Example of Autotransformer
27.5kV VWA-Type Rated Voltage [kV] 60/30
21F41,50F41 21F11,50F11 21F13,50F13 21F12,50F12 21F14,50F14
Vacuum Switch Type ONAN
Rated Self Capacity [MVA] 10
Power Line Capacity [MVA] 20
AT41 AT11 AT13 AT12 AT14
27F41M 27F11 27F13 27F12 27F14
Overload 300% 2min
27F41W VS-A VS-B VS-A VS-B Can withstand thermally and mechanically
Short Circuit Intensity
※5
for 25 or 35 times of the rated current
Applicable Standard JEC / IEC
Note: IEC Standards is also applicable

VS (Vacuum Switch)
Frequently Changeover
Capability
(over 200,000 times)
Control & Relay
Panel Overview
Auto-transformer
9 10
P12上
P16上
5 ~ 252
~ 63
Feeding Circuit Breaker / Switchgear
Rated Voltage [kV]
Rated Bus Current [A]
36 / 72
1200 Cooling and Insulating Method Gas Mineral Oil
Feeding Circuit Breaker / Switchgear
Liquid Silicone Vegetable Oil Epoxy Resin
~ 1050
~ 460 4-3 (Solid Insulated Switchgear)
Rated Breaking Current [kA]

Rated Withstand Voltage


Lightning Impulse [kV]
16 / 25
200 / 350
Rated Power
Primary
4-4 ∼ 77kV (Gas Insulated Switchgear)
Applicable for up to 6MW Rectifier
∼ 35kV
/ IEC Power Frequency [kV] 70 / 140 Rated Voltage
P6 P12上 Secondary Applicable for DC600V / 750V / 1500V / 3000V
Applicable Standards JEC / IEC P16上
Applicable Standard JEC / IEC
Toshiba offers
Rated a single-phase
Voltage [kV] SIS for AC Feeding System.
72.5 ~ This
252 next generation switchgear uses an
Rated Voltage improved insulation
material in 36 / 72
[kV] Dual or single-pole circuit breakers are used for AC outgoing feeders. These must demonstrate a long operating life and have a reclosing
place of theInterrupting
Rated conventional SF[kA]
Current 6 gas which further enhances
25 ~ 63 its functionality and reliability.
Rated Using epoxy
Bus Current [A] resin material for insulation 1200 function. Individual
Cooling and gas
Insulating circuit breakers (GCB),
Method Gas gas insulated switchgears
Mineral Oil (GIS), orLiquid
cubicle type gas insulated
Silicone switchgears
Vegetable Oil (C-GIS) are used.
Epoxy Resin
P13上 Rated Lightning Impulse Withstand Voltage [kV]
also allows both installation even in harsh environment and drastic reduction inP16下
325 ~ 1050 space
Rated requirement.
Breaking Current [kA]Furthermore, SIS has a 16 / 25 Rated Power Applicable for up to 6MW Rectifier
modular composition
Rated Rated Power
Voltage which
[kV] Frequency 42enables
Withstand easier
Voltage [kV]replacement, maintenance and customization.
140 ~ 460
Cooling Method
Rated Withstand Voltage
Lightning Impulse [kV]
Vertical heat-pipe self cooling
200 / 350 Primary ∼ 77kV ∼ 35kV
Rated Voltage
GSM / GSP Rated Applicable
Current [A]Standards 1200 JEC / IEC
Rated Power
Power Frequency [kV]
~ 6 MW
70 / 140 Secondary Applicable for DC600V / 750V / 1500V / 3000V
72 / 84 / 168 Between Main Circuit and Earth 200 Applicable Standards JEC / IEC Applicable Standard JEC / IEC
Lightning Rated Voltage DC 600V / 750V / 1500V
Motor Spring Rated Impulse [kV] Between Main Circuit Terminals 250
Withstand Applicable Standard
Operation JEC / IEC
Power Between Main Circuit and Earth 70 – 1min.
Voltage P13上 mechanism VDS P16下
Frequency [kV] Between Main Circuit Terminals 100 – 10min.
350 / 400 / 750 P7上 Bus
Rated Short Time Withstand Rated Voltage [kV] 42 Cooling Method Vertical heat-pipe self cooling
12.5 – 2sec. GSR GSM / GSP
140 / 160 / 325 Current [kA] Rated Current [A] 1200 Rated Power ~ 6 MW
Rated Voltage [kV] Mechanical240 / 300 times
200,000 72 / 84 / 168 Between Main Circuit and Earth 200
Lightning Rated Voltage DC 600V / 750V / 1500V
Switching Lifetime
Method of Operation Hydraulic Motor Spring Rated Impulse [kV]
Electrical 100,000 times Between Main Circuit Terminals 250 Applicable Standard JEC / IEC
Withstand
Tank Dead Tank Power Between Main Circuit and Earth 70 – 1min.
Voltage
Lighting Frequency [kV] Between Main
Rated Impulse [kV]
900 / 1050 350 / 400 / 750 ESCircuit Terminals 100 – 10min.
Withstand Rated Short Time Withstand
Voltage Power 200-265-200(1min)/ 12.5 – 2sec. C-GIS for AC Traction Circuit GIS for AC Traction Circuit GCB for AC Traction Circuit
140 / 160 / 325 Current [kA]
P21
P19上 Frequency [kV] 250-330-250(1min)
72 84 Applicable Standards JEC / IEC Mechanical 200,000 times
Switching Lifetime

1700
Rated Voltage [V] DC 750 , 1500 Electrical
350 400 P6 VCB 100,000 times Ratings (C-GIS)
P12上
Rated Current [A] 3000 , 4000 1,000kW‐continuous rating
Regenerating Inverter mode P16上
140 160 Rated Breaking Capacity [kA] 50 (at 3×106A / sec), 100 (at 10×10 6A / sec) Capacity
Rated Voltage [kV] 72.5 ~ 252
3,000kW‐1minute or 4,500kW-30seconds
Rated Voltage [kV] 36 / 72 Features • Compact Design
/ Rated Short Time Current [kA] 50-1sec , 100-1sec Powering Converter mode 1,000kW‐continuous rating only
0
800 / 1250 P8
Rated Interrupting Current [kA]
CT
25 ~ 63 Rated Bus Current [A] 1200 Cooling •and
Outdoor Compatibility Gas
Insulating Method
Applicable Standard JIS (To be developed for IEC) P21
P19上 Rated Lightning Impulse Withstand
1,500VDC Voltage [kV] 325 ~ 1050 Rated Breaking Current [kA] 16 / 25 Rated Power
1.5 Rated Voltage [kV] 24 36 40.5 72 84 RatedRated
Input Voltage OutputVoltage
Power Frequency Withstand control [kV]
mode (Make 140a selection
~ 460 for your operation ) Lightning Impulse [kV] 200 / 350 • Safe Operation
Primary
Rated Voltage [V] -1) Load
DC 750 , 1500control: To 6% or 8% output regulation Rated Withstand Voltage
Rated Voltage
Applicable Standards -2) Constant voltage control JEC / IEC Power Frequency [kV] 70 / 140
/ GB Rated Lightning Impulse [kV] 125 170 185 15350
00
400
Rated Current [A] 3000 , 4000 1,000kW‐continuous rating • Low Maintenance
Secondary
Withstand Applicable Standards Regenerating Inverter mode
JEC / IEC Applicable Standard
Voltage Power Frequency [kV] 50 70 95 140 160 RatedBreaking
Rated Capacity [kA] 50 1,200VAC
Output Voltage (at 3×106A / sec), 100 (at 10×10 6A / sec) Capacity 3,000kW‐1minute or 4,500kW-30seconds
P19下 600
Rated 1Series * 2Parallel * 6Arm * 2Bridge Powering Converter mode 1,000kW‐continuous rating only
Rated Current [A]
630 / 1250 / 1250 /
800 / 1250 Main Short
CircuitTime Current [kA] 50-1sec
Configuration , 100-1sec
Specifications Applicable 2000
2000 equipments Double bridge parallel configuration by Transformer P13上
Applicable Standard JIS (To be developed for IEC) 1,500VDC P16下
Rated Short27.5kV
Time SIS
Withstand Air Insulated Cross Section Device
P7上 IGBT (3,300V-1,200A) / MG1200FXF1US53(P)
Side View
MV Switchgear Unit 7.2 / 24 / 36kV 25type or
/ 31.5 Rated Voltage
Rated Input Voltage
[kV]
Output control mode (Make a selection for your operation )
42-1) Load control: To 6% or 8% output regulation
Current [kA] Solid Insulated type Device Cooling System Heat-pipe in pure water (natural cooling type) Cooling Method Vertical heat-pipe self cooling
GSR GSM / GSP Rated Current [A] -2) Constant voltage control
1200
Applicable Standard JEC / IEC / GB Inverter-2,700W * 2,200D * 2,900H Rated Power ~ 6 MW
TR : Epoxy Resin Molded Dry

Single Phase Vacuum Circuit Breaker


Rated Voltage [kV] 240 / 300 72 / 84 / 168 Between Main Circuit and Earth 200
12-Pulse Rectifier Unit Up to 2,000kW / Liquid Silicone Dimension Control Panel of Inverter-800W * 1,000D * 2,300H Rated OutputLightning
Voltage 1,200VAC Rated Voltage DC 600V / 750V / 1500V
Single Line Diagram
DC Switchgear Unit DC 600V, DC1500V
SR : Heat-pipe Self-cooling

HSCB or HSVCB
P19下 Method of Operation
Tank
Specifications
Hydraulic
DC Reacrtor-2,800W * 2,000D * 2,500H
Dead Tank
Motor Spring

Applicable equipments
4-5 Rated
Withstand
Voltage
Impulse [kV]
Main Circuit Configuration
Power
Between Main Circuit Terminals 250
1Series * 2Parallel * 6Arm * 2Bridge
Between
Double Main
bridgeCircuit andconfiguration
parallel Earth 70 – 1min.
by Transformer
Applicable Standard JEC / IEC

Lighting Frequency [kV] Between Main Circuit Terminals 100 – 10min.


2-Phase
Auxiliary AC27.5kV
Power Rated 900 / Air
1050Insulated type 350
or / 400 / 750 Device IGBT (3,300V-1,200A) / MG1200FXF1US53(P)
DC 110V, Lead Storage Battery MV Switchgear UnitImpulse 7.2[kV]
/ 24 / 36kV Toshiba's VCB designed for 27.5kV single phase AC feeding system uses high performance vacuum switches that are able to
Supply Unit AC 105V / 210V Withstand Solid Insulated type DeviceShort
Cooling
TimeSystem Heat-pipe
Power 200-265-200(1min)/
Rated
withstand
Withstand 12.5 – 2sec. in pure water (natural cooling type)
GPS
P7下 Voltage 140 / 160 / 325 Current [kA]high voltages and extensive switching cycles.
Inverter-2,700W * 2,200D * 2,900H
Antennae Frequency [kV] 250-330-250(1min) TR : Epoxy Resin Molded Dry
12-Pulse Rectifier Unit
Applicable Up to 2,000kW
Standards / Liquid
JEC /Silicone
IEC Dimension Mechanical 200,000
Control Panel times
of Inverter-800W * 1,000D * 2,300H
ns) @ONAN Rating P10上 Remote Terminal Unit Rated Voltage [kV] 36 40.5 Switching Lifetime
72 84
SR : Heat-pipe Self-cooling Electrical 100,000 times
DC Reacrtor-2,800W * 2,000D * 2,500H
Lightning Impulse [kV] 170 185 350 400
P13 Rated
DC Withstand
Switchgear VoltageDC 600V, DC1500V
Unit HSCB or HSVCB
Example of Scott Connected Transformer Control/Status Signal
Power Frequency [kV] 70 95 140 160
Rated Voltage [kV] 21F Distance
220/27.5 x 2Protection
; 132/27.5
Control x2
Display Current Input
DMS
Auxiliary Power[A]
Rated Current
SW-HUB PC
DC 110V, 630,
Lead Storage 1250, 2500
Battery 630, 1250, 2000 800, 1250 800, 1250 Features • High Voltage Withstand
Supply Unit AC 105V / 210V
 
Voltage Input
Cooling Type 51F Overcurrent
FIONAN / ONAF /Protection
OFAF RatedP8Short Time Withstand Current [kA] 25, 31.5 25, 31.5 P7下 20, 25, 31.5 20, 25, 31.5 Capability
Protection Function P19上 This vacuum circuit P21
Rated Power [MVA] 27F 60Voltage Protection
/ 80 / 100 Applicable Standards JEC / IEC
Receiving,Feeding Rated Voltage [kV] 24 36 40.5 72 84 breaker can be supplied In order to withstand the
Overload 79 Automatic
150% Reclose
(15mins), 200% (5mins) @ONAN Rating Digital Digital [kV]
Rated Voltage [V] DC 750 , 1500 36 40.5 72 84
AT Distribution Line Relay(G2) Relay(G2)
Rated Lightning Impulse [kV]VT Panel
125 170 185 350 400 with or without excessive voltage at the phase
Connection
VT Panel Feeder
LocatorPanel Scott Incoming Panel Bus Tie Panel System 1 Incoming Panel
System 2 Feeder Panel Rated Current [A]Voltage Lightning Impulse [kV]
3000 , 4000 170 185 350 400
Interlock Circuit P13 Withstand Rated Withstand withdrawable trolley. 6 break point, two vacuum
Regenerating Inverter mode
Applicable Standard IEC (Relay Sequence) Voltage Power Frequency [kV] 50 70 95 140 160 Power Frequency
6 [kV]
Rated Breaking Capacity [kA] 50 (at 3×10 A / sec), 100 (at 10×1070
A / sec) 95 Capacity 140 160
21F Distance Protection interrupters are provided in series
Note: JEC Standards is also applicable
630 / 1250 / 1250 / Rated Short
Rated Current [A] Current [kA] 50-1sec , 100-1sec
Time 630, 1250, 2500 630, 1250, 2000 800, 1250 800, 1250
Powering Converter mode
SW
Trip,Reclose, Rated Current [A] 51F Overcurrent Protection 800 / 1250 for the switch.
Fault display 2000 2000 Rated ShortStandard
Applicable Time Withstand Current be developed for IEC) 25, 31.5
[kA]
JIS (To 25, 31.5 20, 25, 31.5 20, 25, 31.5
Protection Function 1,500VDC
27F Voltage Protection JEC / IEC
Clamp
CT
Rated Short Time Withstand
新 P12Current
下 25 / 31.5 新P7下Applicable Standards • Long
Rated Input VoltageLife Operation
Output control mode (Make a sel
[kA] 79 Automatic Reclose -1) Load control: To 6% or 8% ou
Ratings
P11 P10中 27.5kV Vacuum Circuit Breaker
-2) Constant voltage control
Aiming at long life operation,
RatedApplicable Standard JEC27.5
/ IEC / GB Rated Voltage [kV] 36 40.5 72 84
Control Display I
Voltage [kV]
Rated Voltage [kV]
Example 27.5
of Roof-delta Connected Transformer FeaturesRated Current
• SF6[A]gas-less due to epoxy- 1250
Rated Lightning Impulse [kV] 170 185 350 400 a simple
Rated Output Voltageelectro-magnetic
1,200VAC
Main Circuit P19下
Withstand
Rated Lightning
Rated Voltage [kV]
200 (to earth and across
220kV / 60kV×2
open contacts)
Equipment V resin coatingLightning Impulse [kV] 250 Voltage Power Frequency [kV] 70 95 140 160 operation mechanism
Main Circuit Configuration
is*used.
1Series 2Parallel * 6Arm * 2Bridg
Withstand Impulse [kV] 220 (across isolating distance) Rated Withstand Voltage Specifications Applicable equipments Double bridge parallel configurat
Power Frequency [kV] 95 630 / 630 /
VoltageCooling Type ONAN • Compact Design 800 / 800 /
(Line to Power
Rated Power [MVA]
95 (to earth and across open contacts)
120 Rated Short Time Withstand Current [kA] 25 Rated Current [A]
Ratings
MV Switchgear
新 P12 下 Unit 1250 /
7.2 / 24 / 36kV
1250Air/ Insulated
1250 type or
1250 新P7下Device IGBT (3,300V-1,200A) / MG1200FX
Frequency [kV] 110 (across isolating distance) 2500 2000Solid Insulated type Device Cooling System
Earth)
Overload 300% 2min • Outdoor
P11Applicable Standard Compatibility IEC
Rated Short Time Withstand 25 / 25 / 20 / 25 / 20 / 25 /
Heat-pipe in pure water (natural
Rated Current [A] 1250 / 2000 Rated Rated Voltage [kV] 36 40.5 * 2,200D
Inverter-2,700W 72 * 2,900 84
Current [kA] Voltage [kV] 31.5 31.5TR : Epoxy 27.5 Molded
31.5Resin 31.5 Dry
Connection
Rated Applicable
Short TimeStandard
Withstand
Roof-delta
RatedP10上 • Safe
Voltage [kV] Operation27.5 12-Pulse Rectifier
Rated Current [A] Unit Up to 2,000kW / Liquid 1250
Silicone Rated Dimension
Lightning Impulse [kV] 170
Control 185 of Inverter-800W
Panel 350 400
*
31.5 JEC Applicable Standards JEC
SR :/Heat-pipe
IEC Self-cooling Withstand
Current [kA] Rated • Low DC
70 Reacrtor-2,800W * 2,000D *160
2,
Note: IEC Standards is also applicable Maintenance
Lightning
Withstand Impulse [kV]
200 (to earth and across open contacts)
220 (across isolating distance) Rated Withstand Voltage
Lightning Impulse [kV] 250 Voltage Power Frequency [kV] 95 140
Applicable Standard IEC Example of Scott Connected Transformer DC Switchgear Unit DC 600V,
PowerDC1500V HSCB or HSVCB
Frequency [kV] 95 630 / 630 /
Voltage 800 / 800
• High Reliability
Power [kV]
(Line toRated Voltage 95 (to earth and xacross
220/27.5 open contacts)
2 ; 132/27.5 x2 Auxiliary Power
Rated Short Time Withstand
DC Current
110V, [kA] 25Battery
Lead Storage
Rated Current [A] 1250 / 1250 / 1250 125
P10下 Frequency [kV] 110 (across isolating distance) 2500 2000
Earth) Supply UnitStandard
Applicable AC 105V / 210V IEC
Cooling Type ONAN / ONAF / OFAF RatedP7下
Short Time Withstand 25 / 25 / 20 / 25 / 20 / 2
nd mechanically Example of Autotransformer Rated Current [A]
Rated Power [MVA] 1250 / 2000
60 / 80 / 100 Current [kA] 31.5 31.5 31.5 31.
ted current 11 Rated Voltage [kV] 60/30 Rated Short Time Withstand
Overload 150% (15mins), 200% (5mins) @ONAN Rating Rated
Applicable Voltage [kV]
Standards
12
JEC / IEC 3
31.5
Current [kA]
Type ONAN Connection Scott Lightning Impulse [kV] 17
P13 の図 P8 の図

Changeover Switch 4-8 Control / Relay


The Greenhouse Effect Panel
4-6 Sun
P11 の図 P15 の図
Toshiba manufactures single pole vacuum switches (VS) for power switching at phase break points in The integrated control and relay panels are provided for AC feeding substations. They are designed with the advanced digital
AC high speed railway systems. technology and consist of elements such as a digital protection relay, programmable logic controller (PLC), colored LCD touch
A tconnection.
screen, Ethernet LAN mo
Green sph
h ous er
substation substation e Ga
e Power Source

se
s
21F 50F Features • Colored LCD Touch Screen
P12上
Power supply ranges 100 - 250Vdc
Sectioning Post Transformer for Human Interface
Inputs / outputs Digital input 18*
P16上 Earth
5103 / VS-A VS-B
~ 252 Rated Voltage [kV]
Digital output 18*
36 / 72 • Redundant System
~ 63 Rated Bus Current [A] 1200 IGBT
uguese
~ 1050 Rated Breaking Current [kA]
Analog input 4*
16 / 25
Cooling and Insulating Method Gas Mineral Oil Liquid Silicone Vegetable Oil Epoxy Resin Regenerative
Inverter
• Self-monitoring
Escalator and Self-
Lighting
Rated Power Applicable for up to 6MW Rectifier
~ 460
Communication ModbusImpulse
Lightning / IEC61850
[kV]/ IEC60870-5-103
200 / 350 / Primary ∼ 77kV ∼ 35kV
diagnosis Function
protocol & Interface
Rated Withstand Voltage Web browser DNP3.0 etc. Traction Substation Passenger Station Facility
/ IEC Power Frequency [kV] 70 / 140 Rated Voltage
Changeover Switch Relay W205×D187.8×H255.9
ChangeoverJECSwitch
Secondary Applicable for DC600V / 750V / 1500V / 3000V • Alarms and Commands
Dimensions
Applicable Standards / IECin Cubicle Application of Changeover Switch
tection MIMIC W149×D 23.8×H278.5 Applicable Standard JEC / IEC Logs Function
(4 stages) LCD language English / Chinese / Japanese / Portuguese
ction (3 stages) Ratings
P13上
• Measuring Data (voltage,
*Maximum value P16下
(2 stages) current, power, power factor
Rated Voltage [kV] 42 FeaturesCooling •Method
High Voltage Withstand Decelerating / Regeneration by Brake Accelerating / Powering
n (2 stages) △I Current surge protection Vertical heat-pipe self cooling etc.)
n
GSM / GSP Rated Current [A] 1200
di / dt Current rate of rise protection  
Rated PowerCapability ~ 6 MW
72 / 84 / 168
Lightning Between
50 Main Circuitprotection
Overcurrent and Earth (4
200
stages) In order to withstand
Rated Voltage the excessive
DC 600V voltage
/ 750V / 1500V • Connection with Remote
Motor Spring Protection Function
Rated at the phase break point, two vacuum
Impulse [kV]
Control Center (SCADA)

1700
Between
49 Main Circuit
Thermal Terminals
overload 250(2 stages)
protection Applicable Standard JEC / IEC
Withstand interrupters are provided in series for the
Voltage Power Between
59 Main Circuitprotection
Overvoltage and Earth (3
70stages)
– 1min. P9 の図
switch.
Frequency [kV] Between Main Circuit Terminals
350 / 400 / 750 27 Undervoltage protection100 – 10min.
(3 stages)
Rated Short Time Withstand Multi-shots
• Long Life Operation
12.5 – 2sec. auto-reclosing function 21F 50F
140 / 160 / 325 Current [kA] Aiming for long life operation, a simple
Line test Function
Controll Function electro-magnetic operation mechanism is
Switching Lifetime
Mechanical
Interbreaking200,000 times
Function** used. Control/Relay Panel P13 の図
Electrical
Controlling100,000 times
Function(SWGR, CB)
15
00
Metering Function I, V, +Wh, -Wh, Impedance
TO POWER COMPANY 3 phase NETWORK
CB state condition
600
Trip circuit supervision Substation Monitoring System
Power Company 161kV  3
P21
P19上 Trip counter monitoring
Monitoring Function Toshiba offers Substation Monitoring System by DMS (Digital Monitoring System) for Control/Relay systems. DMS stores and displays
72 84 CB operate time

AC Feeding Protection Relay (GRY-200 Series)


27S1,27G1 27S2,27G2
Rated Voltage [V] DC 750 , 1500 21F 50F data of current, voltage, operation count, fault waveform, etc. System monitoring helps maintenance planning activities by utilizing

4-7
350 400 ΣI alarm
Rated Current [A] 3000 , 4000 1,000kW‐continuous rating
tendency information of equipment in substations such as daily and monthly energy status reports, fault history, etc.
Self supervision 51S1,51G1 Regenerating Inverter mode
51S2,51G2
ions140
are required.
160 Rated Breaking Capacity [kA] 50 (at 3×106A / sec), 100 (at 10×10 6A / sec) Capacity 3,000kW‐1minute or 4,500kW-30seconds
Event records Powering Converter mode 1,000kW‐continuous rating only
/ Rated Short Time Current [kA] 50-1sec , 100-1sec
800 / 1250 Record Function Fault records Toshiba's latest IED series
0 GRY-200
ApplicableProtection
Standard Relay JIS
is part
(To beof
developed for IEC) 21F 87T1,51T1,50GT1 50F 87T2,51T2,50GT2 21F 50F
Disturbancevent records requirement. It Load current with 51GT1 51GT2 1,500VDC Load current with
1.5
specifically designed to meet global market Thyristor Controlled
Rated InputCarsVoltage Output control mode (Make a selection for your operation ) Thyristor Controlled Cars
boasts of high functionality
*Communicationand flexibility.
line between Furthermore,
the substation this
is requiered -1) Load control: To 6% or 8% output regulation
m)
Angle

Angle
Mtr1 Mtr2
10 nt

10 nt
-2) Constant voltage control
ce rre

ce rre
/ GB
oh

relay also includes protection functions applied in highly reliable

o
X X
tan Cu

tan Cu
GPS
g Line

g Line
sis ult

sis ult
Antennae
Japanese high speed railway system. X1 Rated Output Voltage
51B1M 51B1T 51B2M 1,200VAC
51B2T X1
Re Fa

Re Fa
Zone1 Zone1
P19下
ult um

ult um
Feedin

Feedin
50OT1T 50OT1M 50OT2T 50OT2T
Detected
1Series Rise Current(Ifv)
* 2Parallel * 6Arm * 2Bridge Dete
(Fa inim

(Fa inim
Main
When aCircuit Configuration Remote Terminal Unit
OT1 X2 train
Double bridge parallelOT2
on 50F
configuration by Transformer X2 When a train on 5
Specifications Applicable equipments
M

M
Zone2 comes, Ifv=√(If 2+IL 2−2×If Zone2 comes, Ifv=
impedance ×IL×coslf~IL) impedance ×IL×
Air Insulated type or
51OT1
Device
zone changes IGBT (3,300V-1,200A) 51OT2T
/ MG1200FXF1US53(P) zone changes
If

If
urrent Control/Status Signal
MV Switchgear Unit 7.2 / 24 / 36kV Load C
Ratings Solid Insulated type um
Device Cooling System Maxim in pure water (natural cooling type)
Heat-pipe Current Input Max
新P13下 IL Control Display IL
DMS SW-HUB PC
TR : Epoxy Resin Molded Dry Failure
Load current of PWM
Inverter-2,700W * 2,200D * 2,900H Voltage Input Failure
Load current of PWM
Zone FI Zone
DC900 / 1800 12-Pulse Rectifier Unit 21F Distance Protection/ Liquid Silicone
Up to 2,000kW Dimension
Controlled Cars Control Panel of Inverter-800W * 1,000D * 2,300H Controlled Cars

4000 ~ 12000 51F SR : Heat-pipe Self-cooling


Overcurrent Protection 21F41,50F41 R2 R121F11,50F11 R 21F13,50F13 21F12,50F12 21F14,50F14 R2 R1 R
DC Reacrtor-2,800W * 2,000D * 2,500H
The Greenhouse Effect
Receiving,Feeding Digital Digital
80 Protection Function 27F Voltage
DC 600V, Protection
DC1500V HSCB or HSVCB
DC Switchgear Unit AT Distribution Line Relay(G2) Relay(G2)
Locator
Automatic Reclose System 1 System 2
Sun
20 79 Interlock Circuit
9.2
Auxiliary Power DC 110V,
50F Instantaneous Lead Storage
Overcurrent Battery AT41
Protection 27F41M
AT11
27F11
AT13
27F13
AT12
27F12
AT14
27F14 (Relay Sequence)
Supply Unit AC 105V / 210V
JIS / IEC Multi-shots auto-reclosing function 27F41W P7下
VS-A VS-B VS-A VS-B
SW
Trip,Reclose,
Control Function Inter breaking function * ※5 Fault display
ns) @ONAN Rating
Controlling function (SWGR, CB) FeaturesRated Voltage
• Compact
[kV] Design 36 40.5 72 84 Clamp
Lightning Impulse [kV] 170 185 350 400 CT
P13
Metering Function I, V, W, +Wh, Impedance
Event records
• Colored
Rated Withstand LCD touch
Voltage screen for
Power Frequency [kV] 70 95 Atmosphere
140 160
Control Display I
21F Distance Protection human interface
Monitoring Function Fault records
Rated Current [A] 630, 1250, 2500 630, 1250, 2000 Greenhouse Gases
800, 1250 800, 1250
51F Overcurrent Protection • Flexible
Rated Short Installation
Time Withstand Current [kA] 25, 31.5 25, 31.5 20, 25, 31.5 Main Circuit20, 25, 31.5
Protection Function Disturbance records Equipment V
27F Voltage Protection Applicable(The touch panel and the main
Standards JEC / IEC
CB and DS status
79 Automatic Reclose
CB and DS response monitoring unit are separated.)
Earth
Record Function Trip circuit supervision • Support a wide range of
Trip counter monitoring categorized by breaking level communication protocol
Self-supervision LCD panel (31.5 inch)
*Communication lines between the substations are required.
13 新 P12 下 新P7下 14
P11
Rated Voltage [kV] 36 40.5 72 84
5 DC Electrification Systems
5-1 Rectifier Transformer
Toshiba also provides a highly-reliable and modernized DC electrification system. In addition to
conventional equipment like rectifier transformers, rectifiers, and high speed circuit breaker (HSCB), a lot
of new equipment has been developed with power electronics and digital technology. Toshiba presents
P15 の図
innovative solutions to meet customers’ needs.

Power Source
Features • For better environmental friendliness, a liquid silicone transformer or vegetable oil transformer can
be used for the rectifier transformer.
• Heat pipe Rectifier has a very high thermal efficiency and can be installed outdoors. Gas Insulated Transformer Liquid Silicone Transformer Epoxy Resin Molded Dry Transformer

Transformer • High Speed Vacuum Circuit Breaker (HSVCB) has high reliability, safety and can reduce
maintenance
• Regenerative Inverter is a good energy saving solution for the efficient use of regenerative braking Features • Nonflammable SF6 Gas Insulated
IGBT
Regenerative power from Escalator
rolling stocks.
Lighting Transformer is suitable for indoor use.
Inverter
• Traction Energy Storage System (TESS) with SCiB™ is a regenerative energy storage solution • Noncombustible liquid silicone
Traction Substationwhich Passenger
is not only Station
useful forFacility
energy saving, but also for promoting power peak cut, line voltage transformer and vegetable
compensation and emergency power supply. oil transformer are friendly to
environment.
• Package Type Substation saves space and construction works.
Vegetable Oil Transformer

P6 P12上
P16上
TOSHIBA's POWER SUPPLY SYSTEMS
Decelerating / Regeneration by Brake
Rated Voltage [kV]
for DC Feeding Substation Rated Voltage [kV]
Accelerating / Powering
72.5 ~ 252 36 / 72 Ratings
Rated Interrupting Current [kA] 25 ~ 63 Rated Bus Current [A] 1200 Cooling and Insulating Method Gas Mineral Oil Liquid Silicone Vegetable Oil Epoxy Resin
Rated Lightning Impulse Withstand Voltage [kV] 325 ~ 1050 Rated Breaking Current [kA] 16 / 25 Rated Power Applicable for up to 6MW Rectifier
Rated Power Frequency Withstand Voltage [kV] 140 ~ 460 Lightning Impulse [kV] 200 / 350
Rated Withstand Voltage Primary ∼ 77kV ∼ 35kV
Applicable Standards JEC / IEC Power Frequency [kV] 70 / 140 Rated Voltage
Secondary Applicable for DC600V / 750V / 1500V / 3000V
Applicable Standards JEC / IEC Applicable Standard JEC / IEC

Regenerative Inverter Heat-pipe cooled Silicon Rectifier SF6 -Gas Insulated Switchgear(GIS) P13上 P16下
P6 P12上
P7上
P13 の図 Power Transformer SF6 -Gas Insulated P16上

Traction Rectifier
Rated(Oil
Voltage [kV]
immersed) 42
Transformer Cooling Method Vertical heat-pipe self cooling
Rated Voltage [kV] 72.5 ~ 252 Rated Voltage [kV] 36 / 72

5-2
GSR GSM / GSP Rated Current [A] 1200
Rated Interrupting Current [kA] 25 ~ 63 Rated Bus Current [A] 1200 Rated Power ~ 6 MW
Rated Voltage [kV] 240 / 300 72 / 84 / 168 Between Main Circuit and Earth 200 Cooling and Insulating Method Gas Mineral Oil Liquid Silicone Vegetable Oil Epoxy Resin
TO POWER
Rated Lightning Impulse COMPANY 3 phase
Withstand Voltage [kV]NETWORK
325 ~ 1050 Rated Breaking Lightning
Current [kA] 16 / 25 Rated Voltage DC 600V / 750V / 1500V
Method of Operation Hydraulic Motor Spring Rated Impulse [kV] Rated Power Applicable for up to 6MW Rectifier
Between Main Circuit Terminals 250 Applicable Standard JEC / IEC
Rated Power Frequency Withstand Voltage [kV] 140 ~ 460 Withstand Lightning Impulse [kV] 200 / 350
Tank Dead Tank Rated Withstand Voltage Primary ∼ 77kV ∼ 35kV
Applicable Standards JEC / IEC Voltage Power Between Main Circuit and Earth 70 – 1min.
Power Frequency [kV] 70 / 140 Toshiba manufactures vertical heat pipe self-cooling
Rated Voltage rectifiers. This rectifier has a large cooling capacity which makes it suitable
Lighting Frequency [kV] Between Main Circuit Terminals 100 – 10min. Secondary Applicable for DC600V / 750V / 1500V / 3000V
Rated Impulse [kV]
900 / 1050 350 / 400 / 750 Applicable Standards JEC / IEC for systems with repetitive overload current and for outdoor installation.
Withstand Applicable Standard JEC / IEC
Rated Short Time Withstand 12.5 – 2sec.
Voltage Power 200-265-200(1min)/
140 / 160 / 325 Current [kA] Traction Energy Storage System (TESS)
Frequency [kV] 250-330-250(1min)
Applicable Standards JEC / IEC P13上
Switching Lifetime
Mechanical 200,000 times Ratings
P16下
P7上 Electrical 100,000 times
Rated Voltage [kV] 42 Cooling Method Vertical heat-pipe self cooling
GSR GSM / GSP
P14~の図
Rated Current [A] 1200 Rated Power 6 MW
Rated Voltage [kV] 240 / 300 72 / 84 / 168 Between Main Circuit and Earth 200
Lightning Rated Voltage DC 600V / 750V / 1500V
P8Method of Operation Hydraulic Motor Spring Rated Impulse [kV] Between Main Circuit Terminals 250
Withstand Applicable Standard JEC / IEC
Tank Dead Tank P19上 P21
Voltage Cubicle type SFBetween
Power 6 -Gas Insulated
Main Circuit and Earth 70 – 1min.
Rated Voltage [kV]
Lighting 24 36 40.5 72 84 Switchgear(C-GIS)
Frequency [kV] Between Main Circuit Terminals 100 – 10min.
Rated 900 / 1050 350 / 400 / 750 Rated Voltage [V] DC 750 , 1500
Rated Impulse [kV]
Withstand Lightning Impulse [kV] 125 170 185 350 400 Heat 1,000kW‐continuous rating
Current
Rated Short [A] Withstand
Time 3000–, 2sec.
4000
Withstand Power
Voltage 200-265-200(1min)/ 12.5 Theory of Heat Pipe Cooling
Regenerating Inverter mode Radiation
95 140 / 140
160 / 325160

Condensation
Voltage Power Frequency [kV] 50 70 Current [kA]
Rated Breaking Capacity [kA] 50 (at 3×106A / sec), 100 (at 10×10 6A / sec) Capacity 3,000kW‐1minute or 4,500kW-30seconds
Frequency [kV] 250-330-250(1min) Fin
Applicable Standards 630 / 1250JEC
/ / 1250
IEC / Rated Short
Switching Time Current [kA] Mechanical
Lifetime
200,000 times
50-1sec , 100-1sec Powering Converter mode 1,000kW‐continuous rating only
Rated Current [A] 800 / 1250 Heat radiation
2000 2000 Applicable Standard Electrical
JIS (To be100,000 times
developed for IEC) => condensation 1,500VDC

Condensation
Rated Short Time Withstand Output control mode (Make a selection for your operation )
25 / 31.5 Rated Input Voltage Maintenance
Current [kA] Heat convection by -1) Load control: To 6% or 8% output regulation PC
-2) Constant voltage control

Vapor Flow
Applicable Standard JEC / IEC / GB Solid Insulated 24kV Metal-clad pressure difference
P8

Liquid Flow

Liquid Flow
Switchgear(SIS) Switchgear P21
P19上 Rated Output Voltage 1,200VAC
P19下 Pressure rise by
Rated Voltage [kV] 24 36 40.5 72 84 evaporation 1Series * 2Parallel * 6Arm * 2Bridge
Rated Voltage [V] DC 750 , 1500 Main Circuit Configuration
Specifications Applicable equipments Double bridge parallel configuration by Transformer
Evaporate
Rated Lightning Impulse [kV] 125 170 185 350 400 1,000kW‐continuous rating
Rated Current [A] 3000 , 4000 Device IGBT (3,300V-1,200A) / MG1200FXF1US53(P) Syste
Withstand MV Switchgear Unit Air Insulated type or Regenerating Inverter mode
7.2 / 24 / 36kV Capacity Coolant evaporation by
Voltage Power Frequency [kV] 50 70 95 140 160 Rated Breaking Capacity [kA] 50 (at 3×106A / sec),
Solid100 (at 10×10
Insulated 6A / sec)
type Device Cooling System
heat Heat-pipe in pure water (natural cooling3,000kW‐1minute
type) or 4,500kW-30seconds
Syst
Rated Short Time Current [kA] 50-1sec , 100-1sec Powering Converter mode* 2,900H 1,000kW‐continuous rating only

Evaporation
630 / 1250 / 1250 / TR : Epoxy Resin Molded Dry Inverter-2,700W * 2,200D
Rated Current [A] 800 / 1250 High Purity
2000 2000 Applicable Standard JIS (To be developed/ for IEC)Silicone Dimension Coolant and element

Heat
12-Pulse Rectifier Unit Up to 2,000kW Liquid Control Panel
1,500VDC of Inverter-800W * 1,000D * 2,300H
Water
P10上 SR : Heat-pipe Self-cooling heat exchange Base Clock
Rated Short Time Withstand Output control mode*(Make
DC Reacrtor-2,800W 2,000Da *selection
2,500H for your operation )
25 / 31.5 Rated Input Voltage
Current [kA] -1) Load control: To 6% or 8% output regulation
Example ofStandard
Scott Connected Transformer DC Switchgear Unit DC 600V, DC1500V HSCB or HSVCB -2) Constant voltage control
MV/LV Metal-clad Applicable
SF6 -Gas Insulated JEC / IEC / GB
Liquid Silicone Transformer DC Switchgear DC Switchgear (HSVCB)
Switchgear Rated Voltage [kV]
Transformer 220/27.5 x 2 ; 132/27.5 x 2 Auxiliary Power DC 110V,
Supply Unit AC 105V / 210V
Lead Storage Battery Rated Output Voltage 1,200VAC Principle of Heat-pipe Self Cooling Heat-pipe Rectifier
Cooling Type ONAN / ONAF / OFAF P19下
15 P7下
Main Circuit Configuration
1Series * 2Parallel * 6Arm * 2Bridge 16 PS
Rated Power [MVA] 60 / 80 / 100 Specifications Applicable equipments Double bridge parallel configuration by Transformer
Overload 150% (15mins), 200% (5mins) @ONAN Rating Rated Voltage [kV]
Device 36
IGBT (3,300V-1,200A) / MG1200FXF1US53(P) 40.5 72 84 PS
Monitoring Function
CB operate time Metering Function I, V, +Wh, -Wh, Impedance
System LAN-A(HUB)
ΣI alarm CB state condition
System LAN-B(HUB) Self supervision Trip circuit supervision
Visual Signal Trip counter monitoring
Event records Monitoring Function
Total Monitoring PCs Operator Console 1 Operator Console 2 Operator CB
Console 3 time
operate
Base Clock Record
Main Server A Function
Main Server B FaultServer
Main records
C
Disturbance records ΣI alarm
Self supervision

5-3 DC Switchgear * Communication lines between the substations are required.

Record Function
Event records
Fault records 5-4 Protection Relay (GRX-200 Series)
PS LAN-A(HUB) Disturbancevent records

PS LAN-B(HUB)
Toshiba offers HS6 Type DC Switchgear with its ownFeeder DC Protection
Panel Variations Relay which satisfies global *Communication
market requirements. Thisthehighly
line between substation is requiered
Negative DS
reliable Incoming
DC Switchgear efficientlyFeeder
undertakes with
itsDScritical role
with bypass DS
in railwaywithpower
Main Bus
DS and bypass
supplyBypass HSCB
systems while ensuring user safety and easy
Main Bus Main Bus Main Bus Main Bus
Ratings
新P18下

maintenance. MTU MTU Back Up Console


DS DS Line
test
HSCB Line
test
HSCB Line
test
HSCB Line
test
HSCB Line
test
HSCB
Power Supply Ranges 100 ~ 250 Vdc
Device Device Device Device Device

HSCB
R
Power Supply System LANR R R R Communication Modbus / IEC61850 / IEC60870-5-103 /
RTU
Protocol & Interface Web browser / DNP3.0 etc
LCD Language English / Chinese / Japanese
GRX200
GRX200 GRX200 GRX200 GRX200 GRX200

Ratings
GRX200
RTU RTU RTU
P16 GRX200 DS
Bypass Bus Bypass Bus
新P13下 GRX200 Applicable Standard IEC
Substations DS DS DS

Features • Compact Design


M M M M

Rated Voltage [V] DC900 / 1800 Bypass Bus 21F Distance Protection
Rated Bus Current [A]Main Bus 4000 ~DS12000 51F Overcurrent Protection
• Combined with
U> 64 DS DS DS
⊿I Delta I protection
Rated Short-circuit Making and Breaking
SAR Current [kA]
SAR
DC DC
80
DC
SAR
DC
SAR Protection Function 27F Voltage Protection
DC Protection Relay Current rate of rise protection
GRX200 GRX200 GRX200 GRX200
N
di / dt
Lightning Impulse [kV] 20 79 Automatic Reclose 50 Over current protection (4 stages)
Rated Withstand Voltage
Power Frequency [kV] 9.2 • User-friendly
50F Instantaneous Overcurrent Protection 49 Thermal overload protection (3 stages)
Applicable Standard JIS / IEC Protection
Human Interface
Multi-shots auto-reclosing function 32 Reverse Overcurrent protection (4 stages)
P16 の図 Control Function Inter breaking function * 64 Grounding overvoltage protection (2 stages) GRX-200 Relay
Controlling function (SWGR, CB) 59 Over voltage protection (2 stages)
Typical Configuration Metering Function I, V, W, +Wh, Impedance 27 Under voltage protection (2 stages)
Event records Multi-shots auto-reclosing function
Negative DS Incoming Feeder with DS
Feeder Panel Variations
with bypass DS Monitoring
with DS and bypass Function
Bypass HSCB
Various
Fault panel configurations
records Line test function
Main Bus Main Bus Main Bus Main Bus Main Bus
Disturbance feeder
such as records panels with Control Inter breaking function *
CB and DS status DS and bypass
DS, bypass
Features
HSCB HSCB HSCB HSCB HSCB
• Compact Design
DS DS Line Line Line Line Line
test test test test test Controlling function (SWGR, CB)
CBHSCB,
and DScan be manufactured.
Device Device Device Device Device

HSCB
R R R R R
response monitoring Section compensation function
Record Function Trip circuit supervision • Colored LCD Touch Screen for
Metering I, V, W, +Wh, -Wh, Impedance
GRX200
GRX200 GRX200 GRX200 GRX200 GRX200 Trip counter monitoring categorized by breaking level Human Interface
GRX200
Event records
Bypass Bus Bypass Bus
GRX200 DS GRX200 Self-supervision Record Fault records • Flexible Installation (The touch panel
DS DS DS
M M M M

Bypass Bus Disturbance records and the main unit are separated.)
U> 64 DS DS DS DS CB and DS status
Main Bus
• Wide Range of Communication
CB and DS response monitoring
DC DC DC DC
SAR SAR SAR SAR
Protocol Supported
N GRX200 GRX200 GRX200 GRX200

Monitoring Trip circuit supervision


Trip counter monitoring categorized by breaking level • Various Protection Elements
Front View Side View of Feeder Panel Self-supervision

Negative Incoming Feeder1 Feeder2 Feeder3 Feeder4 Standby


* Communication lines between the substations are required.
75

75
CONTROL
DUCT VENTILATION OPENING

CONTROL
DEVICES
CONTROL
DEVICES
CONTROL
DEVICES
CONTROL
DEVICES
CONTROL
DEVICES
CONTROL
DEVICES
CONTROL
Section Compensation Function Human Interface
DEVICES

600
650

RELAY
PANEL When the train passes the section, sudden Through the relay ’s user-
RELAY RELAY RELAY RELAY RELAY RELAY
change of current might cause unnecessary trip. friendly HMI screen the circuit
PANEL PANEL PANEL PANEL PANEL PANEL
HSCB I n order to avoid this situation, sec tion breaker can be operated and
2225

compensation function is provided. switchgear conditions can be


2000

600
525

checked.
625

600
125

125

800 600 600 600 600 600 600 70 70


1700
4400
Feeder Relay Mimic

Back View Fault waveforms can be recorded, monitored and generated using the
PC tool. This data can be used for detailed fault analysis during fault
occurances.

LINE TEST DEVICE LINE TEST DEVICE LINE TEST DEVICE LINE TEST DEVICE LINE TEST DEVICE
*1 *2 *1 *2 *1 *2 *1 *2 *1 *2

89FZ1
DS M
89FZ1 89FZ2 89FZ3 89FZ4 HCT
4000A DS DS DS DS
M M M M
4000A 4000A 4000A 4000A HCT

SR(N) DCVT
*1 *1 *1 *1 *1
DS-1 DS-1 DS-1 DS-1

54F1 54F2 54F3 54F4 54FZ


HSCB HSCB HSCB HSCB HSCB
HCT 4000A DCVT 4000A DCVT 4000A DCVT 4000A DCVT 4000A

1500V
64P DC Switchgear
54P
HSCB
HCT HCT HCT HCT

4000A *2 *2 *2 *2 *2

DCSAR DCSAR DCSAR DCSAR


RAIL

Section Compensation Principle PC Tool for Fault Waveform Function


17 18
800 600 600 600 600 600 600
Condensation
Maintenance Energy Printer Printer
Heat convection by PC Management PC (Monochrome) (Color)

Vapor Flow
pressure difference

Liquid Flow

Liquid Flow
RGB Matrix Switch
Pressure rise by
evaporation Other Video Sources
Evaporate
P6 P12上
System LAN-A(HUB)
P16上

High Speed Vacuum Circuit Breaker (HSVCB) Traction Energy Storage System with SCiB™
Coolant evaporation by
Rated Voltage [kV] heat 72.5 ~ 252 Rated Voltage [kV] 36 / 72

5-5 5-7
System LAN-B(HUB)

Evaporation
Rated Interrupting Current [kA] 25 ~High
63 Purity Rated Bus Current [A] 1200 Cooling and Insulating Method Gas
Visual Signal
Mineral Oil Liquid Silicone Vegetable Oil Epoxy Resin
Coolant and element

Heat
Rated Lightning Impulse Withstand Voltage [kV] 325 ~Water
1050 Rated Breaking Current [kA] 16 / 25 Rated
Total Monitoring PCs Operator Console 1
Applicable for up to 6MW Rectifier
Operator Console 2 Operator Console 3
heat exchange Base Clock Main Server A Power
Main Server B Main Server C
Rated Power Frequency Withstand Voltage [kV] 140 ~ 460 Lightning Impulse [kV] 200 / 350
The HSVCB consists of VCB, Capacitor, Control and Protection units.
Applicable Standards JEC / IEC
RatedHSVCB configuration
Withstand Voltage eliminates the use of arc chute and
Power Frequency [kV] 70 / 140 Rated Voltage System
Primary Overview Ratings
∼ 77kV
and Specifications
∼ 35kV
contactor promoting safe operation and easy maintenance. Secondary Applicable for DC600V / 750V / 1500V / 3000V
Applicable Standards JEC / IEC Applicable StandardToshiba developed Traction Energy Storage System (TESS)JEC / IEC Item Rating / Function
Capacitor Unit with SCiB™, an energy saving solution with Toshiba’s own DC 750V
PS LAN-A(HUB) Rated Line Voltage (DC 600V and DC 825V DC 1500V
battery technology of high quality. TESS efficiently charges
P13上 Features P16下 are also available)
P7上 PS LAN-B(HUB) and discharges surplus regenerative energy to/from Rated Power 500kW - 2000kW 1000kW - 4000kW
Control and Protection Unit Rated Voltage [kV] 42 Cooling Method SCiB™.Vertical
TESS is installed
heat-pipe with Toshiba’s patented advance
self cooling Class I, IV, VI - IX (IEC 62924)
GSR GSM / GSP Rated Current [A] 1200 MTU MTU Applicable Class I - IX (IEC 62924) 0.5(p.u.) 60s + 0.25(p.u.)
• Safe OperationBetween Main Circuit and Earth 200 Rated Power V-SOC~(Voltage-State-of-Charge)
6 MW control system which Back Up Console
Load Pattern 0.75(p.u.) continuous
Rated Voltage [kV] 240 / 300 72 / 84 / 168 240s (cycle time: 300s)
Lightning Rated Voltage DC 600V / 750V /
allows flexible control of charge-discharge characteristics
1500V
Method of Operation Hydraulic Motor Spring Rated No Impulse
arc occurs during current breaking due to VCB application.
[kV] Power Supply System LAN RTU Rated Capacity 146kW - 777kW
Between Main Circuit Terminals 250 Applicable Standardin accordance
JEC / IEC to the battery’s State-of-Charge (SOC). This
Withstand
Tank Dead Tank Rated Battery Voltage DC 600V (530V ~ 713V)
Voltage • Low Noise Between Main Circuit and Earth 70 – 1min.
Power
Lighting RTU allows
RTU significant increase in battery lifetime. This system RTU is
Frequency [kV] Between Main Circuit Terminals 100 – 10min. 1. V-SOC Mode
Rated 900 / 1050 350 / 400 / 750 useful not only for energy saving, but for various purposes
Impulse [kV] VCB application allows low noise.
Substations  -Charge and Discharge corresponding with
Withstand Rated Short Time Withstand such as regenerated energy absorption, peak cut, line   feeding voltage and SOC.
P17 の図 140 / 160 / 325
Power 200-265-200(1min)/ VCB Unit 12.5 – 2sec.
Voltage
• Low Maintenance
Current [kA] Operation Mode   Voltage stabilization of transient fluctuation
Frequency [kV] 250-330-250(1min) voltage compensation and emergency power supply.   is also available.
Applicable Standards JEC / IEC Mechanical
Maintenance is free from aerial arc200,000 times
chute and the contactor.
Switching Lifetime 2. Emergency Power Supply Mode
Outline of HSVCB Electrical 100,000 times  -Discharge energy without power from grid.
External Interface 1. V-SOC Control
DC-BUS Receiving 2. Monitoring
P16 の図
Open Command 3. Sequence Control
Detecting Control Function
P8 4. Schedule Control
Overcurrent
Control and Ratings
P19上 P21 5. Data Logging (Option)
P6Rated Voltage [kV] HCT 24 36
Protection Unit
40.5 (HSTC)
72 84 P12上
High performance SCiB™ 6. Remote Maintenance (Option)
Rated Voltage [V] DC 750 , 1500 P16上 Applicable Standard IEC / JEC
Rated
Rated
Lightning Impulse [kV]
Voltage [kV] Sub 125 170 185 350 400
72.5 ~ 252 Turn on the Rated Voltage
Rated Current [kV]
[A] 3000 , 4000 36 / 72 TESS utilizes Toshiba’s own high performance SCiB™.
1,000kW‐continuous
Feeder Panel Variations rating Safe
Withstand Valve Negative DS Regenerating
IncomingFeeder Inverter
with DSmode with bypass DS with DS and bypass Bypass HSCB
Voltage
Rated PowerCurrent
Interrupting Frequency
[kA] [kV]
close 50 Open
70 Both25 Thyristor
95~ 63 140 160Switch Rated Bus
Rated Breaking Capacity
Current [A] [kA] 50 (at 3×106A / sec), 100 (at 10×10
1200 6A / sec)
Capacity This battery has various outstanding characteristics.
Main Bus
3,000kW‐1minute or 4,500kW-30seconds
Main Bus Main Bus Main Bus Main Bus
Valves Cooling and Insulating Method Gas Mineral Oil Liquid Silicone Vegetable Oil Epoxy Resin
Rated Lightning Impulse Withstand Rated Breaking
Rated Short Time Current
Current [kA] 50-1sec , 100-1sec
[kA] 16 / 25 By using unique
Poweringoxide materials,
Converter mode SCiB™ holds1,000kW‐continuous
high resistance rating only
Rated Current [A] openVoltage
630 [kV]
/ 1250 / 1250 325 ~ / 1050
800 / 1250 Rated Power
DS DS Line HSCB Line
Applicable for up to 6MW Rectifier
HSCB Line HSCB Line HSCB Line HSCB

against thermal runaway caused by internal short circuiting Safe


test test test test test
2000 2000
Capacitor Charger

Rated Power Frequency Withstand Voltage [kV] 140 ~ 460 Applicable Standard JIS (To Impulse
Lightning be developed
[kV] for IEC)
200 / 350 1,500VDC
Device Device Device Device Device

Rated Withstand Voltage Primary ∼ 77kV ∼ safe


35kV
- Uses highly
HSCB
Rated ShortStandards
Applicable Time Withstand Main
25JEC / IEC
/ 31.5 Power Frequency [kV] 70 / 140 Rated Voltage brought
Rated Input Voltage Secondary about
Outputby physical
control stresses.
mode
R
(Make a selection for your
R
operation )
R R

lithium titanium
R

Current [kA] Valve


Applicable Standards JEC / IEC
Applicable
-1) Load control: To 6% or 8% output regulation for DC600V / 750V / 1500V Low
/ 3000V
oxide (LTO)
close +
Temperature
GRX200

Applicable Standard JECoff/ IECon/ GB ApplicableGRX200


Standard -2) Constant
GRX200
voltage control
GRX200 GRX200
JEC / IEC
GRX200 GRX200

open
When control and protection unit detects the over current or receives open command Bypass Bus Bypass Bus
Operation Wide Effective
from external devices, the both valves trip and the thyristor switch of capacitor unit is SOC Range
DS GRX200
GRX200 DS DS DS
Rated Output Voltage 1,200VAC M M M M
Can be used at
VCB Unit P19下the current of capacitor unit is in the opposite direction of the load/fault
turned on. Since
Thyristor Capacitor P13上 P16下 1Series * 2Parallel * 6Arm * 2Bridge temperatures
Bypass Bus Provides a large
current, the zero-cross point of DC current can be achieved. Therefore, the DC load/fault Main
U> Circuit64 Configuration as low as -30°C available capacity
P7上 Switch Unit Specifications Applicable equipments
DS
Double bridge parallel
DS
configuration
DS
by Transformer
DS

current can be broken with high reliability and safety. Main Bus
Rated Voltage [kV] 42 Cooling
DC DC DC DC

Device Method Vertical heat-pipe self


SAR SARcoolingGRX200 SAR SAR
IGBT (3,300V-1,200A) / MG1200FXF1US53(P)
GRX200 GRX200 GRX200
Air Insulated type or
N

GSR Load / Fault Current


GSM / GSP MV Switchgear
Rated Unit
Current [A] 7.2 / 241200
/ 36kV High Input /
Rated Voltage [kV] 240 / 300
Solid Insulated type Rated
DevicePower
Cooling System ~ 6 MWHeat-pipe in pure water (natural cooling type) Rapid Output
Principle of Cutting off DC72 / 84 / 168
Current by HSVCB Lightning Between Main Circuit and Earth 200 Rated Voltage DC 600V / 750V / 1500V Charging
Rated TR : Epoxy Resin Molded Dry Inverter-2,700W * 2,200D * 2,900H Chargeable at large
Method of Operation Hydraulic Motor Spring Impulse [kV] Between Main Circuit Terminals 250
12-Pulse Rectifier Unit Up to 2,000kW
Withstand / Liquid Silicone Applicable
Dimension Standard JEC / IEC
Control Panel of Inverter-800W * 1,000D * 2,300H can be fully charged current and provides
P10上
Tank Dead Tank Between Main Circuit and EarthSelf-cooling
SR : Heat-pipe 70 – 1min. in 6 minutes* large current output
Voltage Power
Lighting Frequency [kV] Between Main Circuit Terminals 100 – 10min.
DC Reacrtor-2,800W * 2,000D * 2,500H Long Life
Package-Type DC Substation
Rated 900 / 1050 350 / 400 / 750 DC Switchgear Unit DC 600V, DC1500V HSCB or HSVCB can be operated up to
Example of Scott
ImpulseConnected
[kV] Transformer

5-6
Withstand Rated Short Time Withstand 15,000 charge-discharge cycles
Voltage Power
Rated Voltage [kV] 200-265-200(1min)/
220/27.5 x 2 ; 132/27.5 x 2 140 / 160 / 325 Auxiliary Power DC 12.5 – 2sec.
110V,
Current [kA] Lead Storage Battery
Frequency [kV] 250-330-250(1min) Supply Unit AC 105V / 210V
Cooling Type ONAN / ONAF / OFAF Crush Test for SCiB™ Cell Battery
Applicable Standards JEC / IEC Mechanical 200,000 times P7下
Rated Power [MVA] 60 / 80 / 100 Switching Lifetime *Results of cell level tests under certain conditions.
Toshiba has developed the compact “Package-Type DC Electrical 100,000
Substation”. It is suitable for small-capacity times and temporary
substations Not a guaranteed performance.
Overload 150% (15mins), 200% (5mins) @ONAN Rating Rated Voltage [kV] 36 40.5 72 84
substations during rehabilitation work, and it reduces substation space.
Connection Scott Lightning Impulse [kV]
P13 System
Rated Withstand Voltage Outline 170 185 350 400
Applicable Standard IEC Power Frequency [kV] 70 95 140 160
P8 21F Distance Protection
Note: JEC Standards is also applicable
FRONT VIEW Rated Current [A]
P21 630, 1250, 2500 630, 1250, 2000 800, 1250 800, 1250
P19上
51F Overcurrent Protection Rated Short Time Withstand Current [kA] 25, 31.5 25, 31.5 20, 25, 31.5 20, 25, 31.5
Rated Voltage [kV] 24 36 40.5 72 84 Protection Function
Rated
Features
Rated Voltage [V] • Compactness Voltage Protection
27FDC 750 , 1500 Applicable Standards JEC / IEC
Lightning Impulse [kV] 125 170 185 350 400 79 3000 , 4000
Automatic Reclose 1,000kW‐continuous rating
Rated Current [A]
Withstand Regenerating Inverter mode
P10中
Voltage Power Frequency [kV] 50 70 95 140 160 • Flexible
Rated Breaking Capacity [kA]
Layout
50 (at 3×10 A / sec), 100 (at 10×10 A / sec)
6 6 Capacity 3,000kW‐1minute or 4,500kW-30seconds
Rated Short Time Current•[kA]
Control Panel
Powering Converter mode 1,000kW‐continuous rating only Converter
Example of Roof-delta
Rated Current [A]
630 / 1250 / 1250 /
Connected Transformer 800 / 1250 Short Construction
50-1sec , 100-1sec Period
2000 2000 Applicable Standard JIS (To be developed for IEC) 500W × 600D × 2100H 600W x 1700D x 2200H
Rated Voltage [kV] 220kV / 60kV×2 1,500VDC
Rated Short Time Withstand × 2 Panel (3000W x 2380D x 2300H
25 / 31.5 DC Rated Input Voltage Output control mode (Make a selection for your operation )
Cooling[kA]
Current Type ONAN for 1000kW - DC 1500V)
switchgear -1) Load control: To 6% or 8% output regulation
DC auxiliary -2) Constant voltage control 新P7下
Rated Power
Applicable [MVA]
Standard 120 JEC / IEC / GB (Negative 新 P12 下
Power
Overload 300% 2min panel) P11 DC600V

Connection Roof-delta
Ratings
P19下
Rated
Rated Output
VoltageVoltage
[kV] 1,200VAC 27.5 Rated Voltage [kV] 36 40.5 72 84
Rated Voltage [kV] 27.5 1Series * 2Parallel * 6Arm *1250
2Bridge Rated Lightning Impulse [kV] 170 185 350 400
Rated Current [A]
Main Circuit Configuration
Applicable Standard JEC Double bridge parallel configuration by Transformer Withstand
Note: IEC Standards is also applicable
Rated Lightning
Specifications Applicable equipments
200 (to earth and across open contacts)
Rated Withstand Voltage
Battery Panel
Lightning Impulse [kV] 250 Voltage Power Frequency [kV] 70 95 DC 140
Switchgear
160
Withstand Impulse [kV] 220 (across isolating
Air distance)type or
Insulated Device IGBT (3,300V-1,200A) / MG1200FXF1US53(P)
MV Switchgear Unit
Voltage 7.2 / 24 / 36kV
Solid Insulated type 600WPower
× 650DFrequency
× 2100H[kV] 95 630 / 630 /600W800 × 1700D
/ × 2100H
800 /
Device Cooling System Heat-pipe in pure water (natural cooling type) Rated Current [A] 1250 / 1250 /× 2 Panel
(Line to Power 95 (to earth and across open contacts) × 8 Panel
Rated Short Time Withstand Current [kA] 25 1250 1250
P10下 Frequency [kV] 110 (across isolating distance) Inverter-2,700W * 2,200D * 2,900H 2500 2000
Earth) TR : Epoxy Resin Molded Dry Applicable Standard IEC
/ Liquid Silicone Dimension Rated Short Time Withstand 25 / 25 / 20 / 25 / 20 / 25 /
Example of Autotransformer
P10上
12-Pulse
Rated Current [A] Unit Up to 2,000kW
Rectifier 1250 / 2000 Control Panel of Inverter-800W * 1,000D * 2,300H
SR : Heat-pipe Self-cooling Current [kA] 31.5 31.5 31.5 31.5
DC Reacrtor-2,800W * 2,000D * 2,500H
Rated Voltage [kV]Auxiliary AC switchgear
60/30 Rated Short Time Withstand 31.5 Applicable Standards JEC / IEC
Example of Scott Connected Rectifier DC switchgear DC Switchgear
[kA] Unit DC 600V, DC1500V HSCB or HSVCB
Type Power Supply Transformer
(Power Receiving ONAN
Current
equipment (Feeder panel) DC750V
panel panel) Auxiliary
ApplicablePower
Standard DC 110V,
Rated Voltage [kV] 220/27.5 x 2 ; 132/27.5 x 2 IEC Lead Storage Battery
Rated Self Capacity [MVA] 10 Supply Unit AC 105V / 210V *Dimensions of 500kW TESS for DC 750V Railway System
Cooling Type
Power Line Capacity [MVA] ONAN
20 / ONAF Outline of Package-Type DC Substation
/ OFAF P7下
1
19 Rated Power [MVA]
Overload 60 / 80 2min
300% / 100 20
Overload 150% (15mins), 200%
Can withstand (5mins)
thermally and@ONAN Rating
mechanically Rated Voltage [kV] 36 40.5 72 84
Short Circuit Intensity
Connection for 25 or 35 times of the rated current
Scott Lightning Impulse [kV] 170 185 350 400
6 Power SCADA
5-8 Regenerative Inverter
The regenerative inverter is P15 の図
a solution for regenerative braking power from rolling stocks. It converts the DC regenerative power
back to AC power and supplies it to the auxiliary system for passenger stations. Toshiba supplies the IGBT inverters with heat pipe
Overview
cooling systems.
Features
Toshiba produces Supervisory Control And Data Acquisition (SCADA)
systems for railway power supply systems with ICT which enables
stable and highly-reliable train operations. Toshiba’s abundant 1. High Reliability by Triple Servers
Power Source
The triple-server system enables highly reliable operation. It can allow
expertise allows for production of user-friendly systems. For instance, duplex servers operation even while maintenance and training. Of
when a fault occurs on the distribution network, many fault signals course, each of the three servers can be changed automatically or
Features will be sent simultaneously from some substations to the SCADA manually to service, standby or simulation mode.
server in the Control Center. The operator would subsequently
Transformer
become confused by the many faults and alarms. Our system
2. Server-less Manual Control on Console
The performance of the IGBT inverters has been The substation monitoring and the individual manual control functions are
therefore collects related information and displays what originally installed in the Console PC. These functions are therefore available even if
upgraded in comparison with conventional
IGBT happened, and then activates recovery control or shows the recovery the connection between the servers and Remote Terminal Unit (RTU) fails.
Regenerative Escalator Lighting thyristor inverters.
Inverter procedure to the operator. In addition, the simulation function
provides training for immediate and exact recovery. 3. Remote Back-up Console for Emergencies
Traction Substation Passenger Station Facility
• Reduces Harmonics Toshiba takes customers requirements into account in its flexible Installing the Console PC in the substation makes remote back up
control possible from the substations.
Harmonics distortion can be reduced due to the advanced approach to producing SCADA systems.
gate control.
4. Registered Sequential Control
• High Power Factor This function controls multiple local equipment sequentially with one
action. The operator can define and register the condition, equipment
The power factor is close to 1.0. to be controlled, and sequence depending on their usability.
Decelerating / Regeneration by Brake Accelerating / Powering

• Low Loss 5. Fault Recovery Control


In case of a fault in some substations or the distribution network, the
• Easy Operation and Maintenance fault recovery control (consisting of reclosing tripped circuit breakers,
P16上
A touch screen on the panel for operation and maintenance. fault location control, etc.) will be done automatically or manually while
displaying recovery procedure to facilitate immediate and exact recovery.
Cooling and Insulating Method Gas Mineral Oil Liquid Silicone Vegetable Oil Epoxy Resin
Rated Power Applicable for up to 6MW Rectifier
6. Simulation (Training)
50 This function provides training for operators and conducts test for
Primary ∼ 77kV ∼ 35kV
0 Rated Voltage maintenance with a pair of servers and with the operator console in off-
Secondary P13 の図 Applicable for DC600V / 750V / 1500V / 3000V line status with all substations. Playing the “Simulation Scenario” which
EC Applicable Standard JEC / IEC can be made from actual event logs simulates faults and circuit breakers
P14 の図 P18 の図 tripped as if actual accidents had happened. This allows the operator to
experience training that is effective for immediate and exact recovery.
TO POWER COMPANY 3 phase NETWORK
P16下

Cooling Method Vertical heat-pipe self cooling


Rated Power ~ 6 MW
Heat
00 Rated Voltage DC 600V /Theory
750V / 1500V Total Monitoring Display
of Heat Pipe Cooling Radiation
Condensation

50 Fin
Applicable Standard JEC / IEC
0 – 1min. Heat radiation
00 – 10min. => condensation
Liquid Crystal Displays
Condensation

Maintenance Energy Printer Printer


Heat convection by PC Management PC (Monochrome) (Color)
Vapor Flow

pressure difference
Liquid Flow

Liquid Flow

Regenerative Inverter RGB Matrix Switch


Pressure rise by
evaporation Other Video Sources
Evaporate
System LAN-A(HUB)
Coolant evaporation by
heat System LAN-B(HUB)
P21
Evaporation

Ratings Coolant and element


High Purity Visual Signal
Heat

Water Total Monitoring PCs Operator Console 1 Operator Console 2 Operator Console 3
heat exchange Base Clock Main Server A Main Server B Main Server C
1,000kW‐continuous rating
Regenerating Inverter mode
A / sec) Capacity 3,000kW‐1minute or 4,500kW-30seconds
Powering Converter mode 1,000kW‐continuous rating only

1,500VDC
Rated Input Voltage Output control mode (Make a selection for your operation ) PS LAN-A(HUB)
-1) Load control: To 6% or 8% output regulation
-2) Constant voltage control PS LAN-B(HUB)

Rated Output Voltage 1,200VAC MTU MTU Back Up Console


1Series * 2Parallel * 6Arm * 2Bridge
Main Circuit Configuration
pments Double bridge parallel configuration by Transformer Power Supply System LAN RTU
or Device IGBT (3,300V-1,200A) / MG1200FXF1US53(P)
pe Device Cooling System Heat-pipe in pure water (natural cooling type) RTU RTU RTU

olded Dry Inverter-2,700W * 2,200D * 2,900H Substations


ne
-cooling
Dimension
P17 の図
Control Panel of Inverter-800W * 1,000D * 2,300H
DC Reacrtor-2,800W * 2,000D * 2,500H Typical System Configuration
21 22
ery External Interface