Sunteți pe pagina 1din 2

Republic of the Philippines

Region Vll, Central Visayas


DIVISION OF CEBU PROVINCE
CALAPE NATIONAL HIGH SCHOOL
Calape, Daanbantayan Cebu

2nd Periodical Test in TLE-Grade X

NAME: ________________________Year&Section:______________Date:_________
1. Choose the letter of the correct answer and write the letter on the space provided.
_______1. It is any associated material for connecting end of stock securely.
a. Fitting b. Ground c. rigid d. wire ways
_______2. It is used for mounting a convenience outlet on walls.
a. Junction box b. Frames c. Utility Box d. strap
_______3. It is used for splitting conductors and splices.
a. Utility Box b. Fastening Device c. Junction Box d. Adhesive
_______4. It is a bend used to adopt the conduit from the surface to a particular box or fittings.
a. Bending b. Offset c. Conduit bending d. Strap
_______5. It is a process of removing sharp edges or burns left after.
a. shaping b. reaming c. finishing d. smoothing
_______6. What is the tool used to bend a metallic conduit?
a. Hacksaw b. Hickey c. Hammer d. Reamer
_______7. How many degrees is a quarter angle bend?
a. 45 degrees b. 90 degrees c. 180 degrees d. 135 degrees
_______8. What type of conduit is designed to lessen or eliminate fire hazard and electrical accident?
a. Electrical Metallic Tubing b. Rigid Steel Conduit c. Polyvinyl Chloride d. Armored Cable (BX)
_______9. How many quarter bends are allowed in a one run of electrical metallic and nonmetallic conduit
as allowed by the code?
a. 2 b. 3 c. 4 d. 6
_______10. What type of fitting is used to secure EMT to metallic boxes?
a. connector b. condulets c. adaptor with locknut d. coupling
_______11. What is the type of bend that makes one quarter turn?
a. offset b. elbow c. saddle d. goose neck
_______12. What is the standard length of Rigid Metallic Conduit?
a. 10 ft. b. 12 ft. c. 14 ft. d. 20 ft.
_______13. A neutral conductor shall be placed within the _________?
a. same conduit b. the other conduit c. anywhere
_______14. It is the minimum size of conduit which can be installed in industrial occupancies
a. ½” b. 3/4” c. 1” d. 1
_______15. It is type of fitting which is used to change direction.
a. connector b. coupling c. adaptor d. elbow
_______16. It is a short length conduit or tubing which is used to extend a conduit system and used
between conduit and tubing such as boxes or enclosures between two boxes.
a. connector b. coupling c. nipple d. condulets
_______17. It is type of bend which is used for circuit homerun.
a. offset b. elbow c. saddle d. goose neck
_______18. What electrical materials are used for the installation of electrical wiring fixtures like switches,
receptacles and for making electrical termination?
a. Utility Box b. Square Box c. Junction Box d. electrical Boxes
_______19. What code is responsible for setting the rules and regulations which govern all electrical wiring
installations wherein standard and specifications must be followed?
a. Municipal code b. Local code c. Philippine Electrical code d. National Electrical Code
_______20. What types of electrical conduit re designed to protect the electrical wiring of building from
electrical hazard due to faulty wiring?
a. Electrical Metallic Tubing b. Rigid Steel Conduit c. Polyvinyl Chloride d. Flexible Metallic T
_______21. It is any associated material for connecting end of stock securely.
a. Fitting b. Frames c. Rigid d. wire ways
_______22. It is used for mounting a convenience outlet on walls
a. Junction Box b. Frames c. Utility Box d. Fitting
_______23. It is used for splitting conductors and splices.
a. Utility Box b. Fastening Device c. Junction Box d. Adhesive
_______24. It is bend used to adopt the conduit from the surface to a particular box or fittings.
a. Bending b. offset c. conduit bending d. strap
_______25. It is a process of removing sharp edges or burns left after cutting the pipe.
a. shaping b. reaming c. finishing d. smoothing
_______26. What is the tool used to bend a metallic conduit?
a. Hacksaw b. hickey c. hammer d. reamer
_______27. How many degrees is a quarter angle bend?
a. 45 degrees b. 90 degrees c. 180 degrees d. 135 degrees
_______28. What type of conduit is designed to lessen or eliminate fire hazard and electrical accident?
a. Electrical Metallic Tubing b. Rigid Steel Conduit c. polyvinyl Chloride d. Armored Cable (BX)
_______29. How many quarter bends are allowed in a one run of electrical metallic and nonmetallic as
allowed by the code?
a. 2 b. 3 c. 4 d. 6
________30. What type of fitting is used to secure EMT to metallic?
a. connector b. condulets c. adapter with locknut d. coupling

ll. Matching type. Match column A to Column B


______1. PEC a. cutting
______2. RSC b. reaming
______3. Standard size of RSC c. elbow
______4. Standard size of EMT d. nipples
______5. Process of bend using hickey e. coupling
______6. Process of the conduit using hacksaw and pipe bender f. condulets
______7. Removing of burns after cutting g. bending
______8. Process of bent section of conduit used to change the raceway h. ½, ¾ ,1, 1 ¼
______9. Short length use to extend conduit system i. ½ , ¾ , 1 up to 6”
______10. Device connecting two pieces of pipes in order to extend j. rigid steel conduit
the length. k. Philippine Electrical Code

lll. Make the ACTUAL connection and write the different ELECTRICAL materials to be use of this circuit. 5pts
each.

S-ar putea să vă placă și