PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 450 504 548
Air Pressure Drop (bar) 0,13 0,16 0,19
Air Temperature at Dryer Outlet (°C) 26,4 27,0 27,3
Adsorbed power (kW) * 0,90 0,95 1,00
Condenser Heat Rejected (kW) 3,90 4,09 4,30
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 2830 / 1
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 55
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Pistons / 1
Refrigerant Quantity (kg) 1,45
Capacity Control Hot Gas by-pass
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 1
Separator Type Demister
Drain Type Timed or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet 1½” BSP - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 703
Height (mm) 945
Depth (mm) 562
Weight (kg) 83
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 230V / 1Ph / 50Hz
L.R.A. Current (Amps) 30
F.L.A. Current (Amps) 7,3
Total Installed Power (kW) 1,4
Control Type Electronic
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD95HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 570 635 688
Air Pressure Drop (bar) 0,21 0,25 0,29
Air Temperature at Dryer Outlet (°C) 25,9 26,4 26,7
Adsorbed power (kW) * 1,38 1,41 1,45
Condenser Heat Rejected (kW) 5,04 5,32 5,58
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 2830 / 1
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 58
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Pistons / 1
Refrigerant Quantity (kg) 1,18
Capacity Control Hot Gas by-pass
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 1
Separator Type Demister
Drain Type Timed or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet 1½” BSP - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 703
Height (mm) 945
Depth (mm) 562
Weight (kg) 83
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 230V / 1Ph / 50Hz
L.R.A. Current (Amps) 51
F.L.A. Current (Amps) 10,0
Total Installed Power (kW) 2,0
Control Type Electronic
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD120HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 720 784 881
Air Pressure Drop (bar) 0,13 0,15 0,19
Air Temperature at Dryer Outlet (°C) 26,4 26,7 27,3
Adsorbed power (kW) * 1,13 1,16 1,19
Condenser Heat Rejected (kW) 5,86 6,14 6,50
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 2800 / 1
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 58
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 1,7
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 1
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet 2” BSP - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 706
Height (mm) 1064
Depth (mm) 1046
Weight (kg) 145
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 26,6
F.L.A. Current (Amps) 4,1
Total Installed Power (kW) 2,4
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD140HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 840 947 1033
Air Pressure Drop (bar) 0,18 0,22 0,27
Air Temperature at Dryer Outlet (°C) 26,0 26,4 26,9
Adsorbed power (kW) * 1,14 1,17 1,20
Condenser Heat Rejected (kW) 6,73 7,15 7,48
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 2800 / 1
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 58
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 1,7
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 1
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet 2” BSP - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 706
Height (mm) 1064
Depth (mm) 1046
Weight (kg) 145
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 26,6
F.L.A. Current (Amps) 4,1
Total Installed Power (kW) 2,4
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD180HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 1080 1198 1326
Air Pressure Drop (bar) 0,23 0,28 0,34
Air Temperature at Dryer Outlet (°C) 26,4 26,7 27,1
Adsorbed power (kW) * 1,46 1,48 1,50
Condenser Heat Rejected (kW) 8,54 9,00 9,50
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 4000 / 1
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 58
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 2,2
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 1
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet 2” BSP - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 706
Height (mm) 1064
Depth (mm) 1046
Weight (kg) 155
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 34,6
F.L.A. Current (Amps) 5,2
Total Installed Power (kW) 3,0
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD220HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 1320 1480 1640
Air Pressure Drop (bar) 0,09 0,11 0,14
Air Temperature at Dryer Outlet (°C) 28,2 28,6 28,8
Adsorbed power (kW) * 1,68 1,70 1,72
Condenser Heat Rejected (kW) 9,07 9,65 10,17
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 7050 / 1
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 58
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 4,2
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 1
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet 2½” BSP - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 806
Height (mm) 1316
Depth (mm) 1166
Weight (kg) 230
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 37,75
F.L.A. Current (Amps) 6,3
Total Installed Power (kW) 3,4
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD260HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 1560 1753 1945
Air Pressure Drop (bar) 0,13 0,17 0,20
Air Temperature at Dryer Outlet (°C) 27,8 28,2 28,4
Adsorbed power (kW) * 2,19 2,22 2,25
Condenser Heat Rejected (kW) 11,31 12,00 12,67
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 7050 / 1
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 58
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 4,1
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 1
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet 2½” BSP - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 806
Height (mm) 1316
Depth (mm) 1166
Weight (kg) 240
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 51,75
F.L.A. Current (Amps) 8,2
Total Installed Power (kW) 4,5
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD300HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 1800 1982 2196
Air Pressure Drop (bar) 0,17 0,20 0,25
Air Temperature at Dryer Outlet (°C) 27,4 27,7 28,1
Adsorbed power (kW) * 2,41 2,44 2,47
Condenser Heat Rejected (kW) 13,40 14,28 14,98
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 7050 / 1
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 58
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 4,3
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 1
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet 2½” BSP - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 806
Height (mm) 1316
Depth (mm) 1166
Weight (kg) 245
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 55,75
F.L.A. Current (Amps) 11,2
Total Installed Power (kW) 5,3
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD350HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 2100 2325 2550
Air Pressure Drop (bar) 0,24 0,28 0,34
Air Temperature at Dryer Outlet (°C) 27,0 27,3 27,7
Adsorbed power (kW) * 3,06 3,09 3,11
Condenser Heat Rejected (kW) 16,2 17,2 17,9
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 7050 / 1
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 58
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 6
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 1
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet 2½” BSP - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 806
Height (mm) 1316
Depth (mm) 1166
Weight (kg) 250
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 71,3
F.L.A. Current (Amps) 13,6
Total Installed Power (kW) 6,26
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD460HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 2760 3050 3437
Air Pressure Drop (bar) 0,14 0,17 0,21
Air Temperature at Dryer Outlet (°C) 27,9 28,2 28,8
Adsorbed power (kW) * 3,14 3,16 3,18
Condenser Heat Rejected (kW) 19,21 20,46 21,70
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 7050 / 1
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 58
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 7,5
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 2
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN 16 - DN 100
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 1690
Depth (mm) 1097
Weight (kg) 470
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 71,3
F.L.A. Current (Amps) 13,6
Total Installed Power (kW) 6,26
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD520HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 3120 3420 3817
Air Pressure Drop (bar) 0,18 0,21 0,26
Air Temperature at Dryer Outlet (°C) 27,6 28,0 28,3
Adsorbed power (kW) * 3,54 3,56 3,58
Condenser Heat Rejected (kW) 22,4 23,7 24,9
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 7050 / 1
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 58
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 8
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 2
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN 16 - DN 100
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 1723
Depth (mm) 1097
Weight (kg) 490
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 79,8
F.L.A. Current (Amps) 13,3
Total Installed Power (kW) 7,46
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD630HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 3780 4155 4648
Air Pressure Drop (bar) 0,26 0,31 0,38
Air Temperature at Dryer Outlet (°C) 27,3 27,6 27,9
Adsorbed power (kW) * 4,64 4,65 4,67
Condenser Heat Rejected (kW) 27,58 29,30 30,90
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 14100 / 2
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 69
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 9,5
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 2
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN 16 - DN 100
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 1722
Depth (mm) 1657
Weight (kg) 580
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 110,5
F.L.A. Current (Amps) 19,3
Total Installed Power (kW) 9,92
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD750HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 4500 4950 5540
Air Pressure Drop (bar) 0,16 0,20 0,24
Air Temperature at Dryer Outlet (°C) 27,8 28,1 28,7
Adsorbed power (kW) * 5,73 5,76 5,77
Condenser Heat Rejected (kW) 32,7 34,7 36,6
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 14100 / 2
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 69
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 12,0
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 3
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN 16 - DN 150
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 1722
Depth (mm) 1657
Weight (kg) 670
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 134,5
F.L.A. Current (Amps) 22,3
Total Installed Power (kW) 11,32
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD900HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 5400 5905 6484
Air Pressure Drop (bar) 0,23 0,27 0,33
Air Temperature at Dryer Outlet (°C) 27,4 27,7 28,1
Adsorbed power (kW) * 7,63 7,65 7,67
Condenser Heat Rejected (kW) 42,85 44,70 46,90
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 19000 / 2
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 69
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 11,0
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 3
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN 16 - DN 150
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 1722
Depth (mm) 1657
Weight (kg) 690
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 180,5
F.L.A. Current (Amps) 29,7
Total Installed Power (kW) 16,26
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD1210HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 7260 7990 8800
Air Pressure Drop (bar) 0,19 0,23 0,28
Air Temperature at Dryer Outlet (°C) 27,5 27,8 28,2
Adsorbed power (kW) * 8,92 8,94 8,96
Condenser Heat Rejected (kW) 55,07 58,08 61,13
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 19000 / 2
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 69
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 15,5
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 4
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN 16 - DN 150
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 2048
Depth (mm) 1657
Weight (kg) 830
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 211,5
F.L.A. Current (Amps) 34,7
Total Installed Power (kW) 19,26
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD1500HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 9000 10073 11136
Air Pressure Drop (bar) 0,20 0,25 0,30
Air Temperature at Dryer Outlet (°C) 27,4 27,6 28,2
Adsorbed power (kW) * 12,35 12,36 12,37
Condenser Heat Rejected (kW) 68,6 72,7 75,9
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 28500 / 3
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 69
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 22,0
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 5
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN 16 - DN 200
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 2208
Depth (mm) 2257
Weight (kg) 1100
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 245,3
F.L.A. Current (Amps) 44,1
Total Installed Power (kW) 25,64
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD1800HS - Air Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 10800 11960 13260
Air Pressure Drop (bar) 0,27 0,33 0,40
Air Temperature at Dryer Outlet (°C) 27,4 27,9 28,2
Adsorbed power (kW) * 15,96 15,98 15,99
Condenser Heat Rejected (kW) 81,90 86,99 90,91
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Ambient Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Condenser Airflow (m³/h) / number of fans 28500 / 3
Maximum Operating Pressure (bar g) 14
Sound Pressure Level (dBA) (1 m free field )** 69
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 23,0
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 6
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN 16 - DN 200
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 2208
Depth (mm) 2257
Weight (kg) 1190
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 292,3
F.L.A. Current (Amps) 56,1
Total Installed Power (kW) 31,04
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
* Compressor Absorbed Power (kW) Max / Min Ambient Temperature (°C): 50 / 5
** Sound pressure level in accordance with ISO 3746 Max / Min Air Inlet Temperature (°C): 65 / 5
*** With Integrated Drain

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD220HSW - Water Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 1320 1481 1653
Air Pressure Drop (bar) 0,09 0,11 0,14
Air Temperature at Dryer Outlet (°C) 28,0 28,5 28,8
Compressor Absorbed Power (kW) 1,61 1,59 1,58
Condenser Heat Rejected (kW) 9,00 9,60 10,20
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Inlet Condenser Water Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Water Flow (m³/h) 0,54 0,58 0,62
Water Pressure Drop* (bar) 0,01 0,01 0,01
Condensing Temperature (°C) 40
Max / Min Inlet Condenser Water Temperature (°C) 48 / 10
Maximum Operating Pressure (bar g) 14
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 3,4
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 1
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet 2½” BSP - F
Water Connections Inlet / Outlet 3/4” BSPT - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 806
Height (mm) 1214
Depth (mm) 1166
Weight (kg) 230
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 32
F.L.A. Current (Amps) 5,1
Total Installed Power (kW) 2,8
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*The total pressure drop, including the water regulator valve, is about 1,7÷2 bar Max / Min Ambient Temperature (°C): 50 / 5
*** With Integrated Drain Max / Min Air Inlet Temperature (°C): 65 / 5

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD260HSW - Water Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 1560 1764 1979
Air Pressure Drop (bar) 0,13 0,17 0,21
Air Temperature at Dryer Outlet (°C) 27,8 28,1 28,4
Compressor Absorbed Power (kW) 2,28 2,26 2,24
Condenser Heat Rejected (kW) 11,3 12,0 12,7
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Inlet Condenser Water Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Water Flow (m³/h) 0,70 0,75 0,81
Water Pressure Drop* (bar) 0,02 0,02 0,02
Condensing Temperature (°C) 40
Max / Min Inlet Condenser Water Temperature (°C) 48 / 10
Maximum Operating Pressure (bar g) 14
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 3,5
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 1
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet 2½” BSP - F
Water Connections Inlet / Outlet 3/4” BSPT - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 806
Height (mm) 1214
Depth (mm) 1166
Weight (kg) 240
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 46
F.L.A. Current (Amps) 7
Total Installed Power (kW) 3,86
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*The total pressure drop, including the water regulator valve, is about 1,7÷2 bar Max / Min Ambient Temperature (°C): 50 / 5
*** With Integrated Drain Max / Min Air Inlet Temperature (°C): 65 / 5

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD300HSW - Water Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 1800 2016 2286
Air Pressure Drop (bar) 0,17 0,21 0,26
Air Temperature at Dryer Outlet (°C) 27,5 28,0 28,2
Compressor Absorbed Power (kW) 2,77 2,77 2,78
Condenser Heat Rejected (kW) 13,3 14,1 15,0
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Inlet Condenser Water Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Water Flow (m³/h) 0,79 0,84 0,90
Water Pressure Drop* (bar) 0,01 0,01 0,01
Condensing Temperature (°C) 40
Max / Min Inlet Condenser Water Temperature (°C) 48 / 10
Maximum Operating Pressure (bar g) 14
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 3
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 1
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet 2½” BSP - F
Water Connections Inlet / Outlet 3/4” BSPT - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 806
Height (mm) 1214
Depth (mm) 1166
Weight (kg) 245
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 50
F.L.A. Current (Amps) 10
Total Installed Power (kW) 4,66
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*The total pressure drop, including the water regulator valve, is about 1,7÷2 bar Max / Min Ambient Temperature (°C): 50 / 5
*** With Integrated Drain Max / Min Air Inlet Temperature (°C): 65 / 5

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD350HSW - Water Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 2100 2369 2616
Air Pressure Drop (bar) 0,23 0,29 0,35
Air Temperature at Dryer Outlet (°C) 27,0 27,5 27,8
Compressor Absorbed Power (kW) 3,49 3,50 3,50
Condenser Heat Rejected (kW) 15,97 17,04 17,94
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Inlet Condenser Water Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Water Flow (m³/h) 0,97 1,05 1,12
Water Pressure Drop* (bar) 0,01 0,02 0,02
Condensing Temperature (°C) 40
Max / Min Inlet Condenser Water Temperature (°C) 48 / 10
Maximum Operating Pressure (bar g) 14
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 2,8
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 1
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet 2½” BSP - F
Water Connections Inlet / Outlet 3/4” BSPT - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 806
Height (mm) 1214
Depth (mm) 1166
Weight (kg) 250
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 65,5
F.L.A. Current (Amps) 12,4
Total Installed Power (kW) 5,65
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*The total pressure drop, including the water regulator valve, is about 1,7÷2 bar Max / Min Ambient Temperature (°C): 50 / 5
*** With Integrated Drain Max / Min Air Inlet Temperature (°C): 65 / 5

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD460HSW - Water Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 2760 3079 3439
Air Pressure Drop (bar) 0,11 0,13 0,16
Air Temperature at Dryer Outlet (°C) 28,1 28,4 28,7
Compressor Absorbed Power (kW) 3,39 3,39 3,39
Condenser Heat Rejected (kW) 19,8 21,1 22,5
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Inlet Condenser Water Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Water Flow (m³/h) 1,18 1,27 1,37
Water Pressure Drop* (bar) 0,04 0,05 0,06
Condensing Temperature (°C) 40
Max / Min Inlet Condenser Water Temperature (°C) 48 / 10
Maximum Operating Pressure (bar g) 14
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 6,6
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 2
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN16 DN100
Water Connections Inlet / Outlet 1” BSPT - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 1586
Depth (mm) 1245
Weight (kg) 470
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 65,5
F.L.A. Current (Amps) 12,4
Total Installed Power (kW) 5,65
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*The total pressure drop, including the water regulator valve, is about 1,7÷2 bar Max / Min Ambient Temperature (°C): 50 / 5
*** With Integrated Drain Max / Min Air Inlet Temperature (°C): 65 / 5

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD520HSW - Water Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 3120 3461 3843
Air Pressure Drop (bar) 0,14 0,17 0,21
Air Temperature at Dryer Outlet (°C) 27,8 28,1 28,4
Compressor Absorbed Power (kW) 3,87 3,87 3,87
Condenser Heat Rejected (kW) 22,70 24,08 25,52
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Inlet Condenser Water Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Water Flow (m³/h) 1,39 1,50 1,61
Water Pressure Drop* (bar) 0,06 0,07 0,08
Condensing Temperature (°C) 40
Max / Min Inlet Condenser Water Temperature (°C) 48 / 10
Maximum Operating Pressure (bar g) 14
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 5,2
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 2
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN16 DN100
Water Connections Inlet / Outlet 1” BSPT - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 1586
Depth (mm) 1245
Weight (kg) 490
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 74
F.L.A. Current (Amps) 12,1
Total Installed Power (kW) 6,85
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*The total pressure drop, including the water regulator valve, is about 1,7÷2 bar Max / Min Ambient Temperature (°C): 50 / 5
*** With Integrated Drain Max / Min Air Inlet Temperature (°C): 65 / 5

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD630HSW - Water Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 3780 4201 4674
Air Pressure Drop (bar) 0,20 0,24 0,30
Air Temperature at Dryer Outlet (°C) 27,4 27,7 28,0
Compressor Absorbed Power (kW) 5,05 5,05 5,04
Condenser Heat Rejected (kW) 28,3 30,1 32,0
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Inlet Condenser Water Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Water Flow (m³/h) 1,86 2,03 2,23
Water Pressure Drop* (bar) 0,10 0,12 0,14
Condensing Temperature (°C) 40
Max / Min Inlet Condenser Water Temperature (°C) 48 / 10
Maximum Operating Pressure (bar g) 14
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 6,3
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 2
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN16 DN100
Water Connections Inlet / Outlet 1” BSPT - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 1586
Depth (mm) 1245
Weight (kg) 580
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 99
F.L.A. Current (Amps) 17
Total Installed Power (kW) 8,7
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*The total pressure drop, including the water regulator valve, is about 1,7÷2 bar Max / Min Ambient Temperature (°C): 50 / 5
*** With Integrated Drain Max / Min Air Inlet Temperature (°C): 65 / 5

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD750HSW - Water Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 4500 5008 5582
Air Pressure Drop (bar) 0,12 0,14 0,18
Air Temperature at Dryer Outlet (°C) 27,9 28,2 28,5
Compressor Absorbed Power (kW) 6,20 6,19 6,17
Condenser Heat Rejected (kW) 33,13 35,21 37,37
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Inlet Condenser Water Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Water Flow (m³/h) 1,95 2,09 2,23
Water Pressure Drop* (bar) 0,04 0,04 0,05
Condensing Temperature (°C) 40
Max / Min Inlet Condenser Water Temperature (°C) 48 / 10
Maximum Operating Pressure (bar g) 14
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 8,5
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 3
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN16 DN150
Water Connections Inlet / Outlet 1½” BSPT - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 1586
Depth (mm) 1807
Weight (kg) 670
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 123
F.L.A. Current (Amps) 20
Total Installed Power (kW) 10,1
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*The total pressure drop, including the water regulator valve, is about 1,7÷2 bar Max / Min Ambient Temperature (°C): 50 / 5
*** With Integrated Drain Max / Min Air Inlet Temperature (°C): 65 / 5

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD900HSW - Water Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 5400 6002 6688
Air Pressure Drop (bar) 0,16 0,20 0,24
Air Temperature at Dryer Outlet (°C) 27,5 27,8 28,1
Compressor Absorbed Power (kW) 8,87 8,90 8,92
Condenser Heat Rejected (kW) 42,0 44,5 47,2
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Inlet Condenser Water Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Water Flow (m³/h) 2,56 2,75 2,97
Water Pressure Drop* (bar) 0,06 0,07 0,08
Condensing Temperature (°C) 40
Max / Min Inlet Condenser Water Temperature (°C) 48 / 10
Maximum Operating Pressure (bar g) 14
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 8,3
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 3
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN16 DN150
Water Connections Inlet / Outlet 1½” BSPT - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 1586
Depth (mm) 1807
Weight (kg) 690
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 167
F.L.A. Current (Amps) 27
Total Installed Power (kW) 14,7
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*The total pressure drop, including the water regulator valve, is about 1,7÷2 bar Max / Min Ambient Temperature (°C): 50 / 5
*** With Integrated Drain Max / Min Air Inlet Temperature (°C): 65 / 5

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD1210HSW - Water Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 7260 8070 8900
Air Pressure Drop (bar) 0,18 0,22 0,26
Air Temperature at Dryer Outlet (°C) 27,5 27,8 28,1
Compressor Absorbed Power (kW) 10,12 10,09 10,07
Condenser Heat Rejected (kW) 54,3 57,6 61,0
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Inlet Condenser Water Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Water Flow (m³/h) 3,59 3,92 4,29
Water Pressure Drop* (bar) 0,11 0,13 0,16
Condensing Temperature (°C) 40
Max / Min Inlet Condenser Water Temperature (°C) 48 / 10
Maximum Operating Pressure (bar g) 14
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 7,7
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 4
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN16 DN150
Water Connections Inlet / Outlet 1½” BSPT - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 1586
Depth (mm) 1807
Weight (kg) 830
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 198
F.L.A. Current (Amps) 32
Total Installed Power (kW) 17,7
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*The total pressure drop, including the water regulator valve, is about 1,7÷2 bar Max / Min Ambient Temperature (°C): 50 / 5
*** With Integrated Drain Max / Min Air Inlet Temperature (°C): 65 / 5

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD1500HSW - Water Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 9000 9989 11108
Air Pressure Drop (bar) 0,19 0,23 0,28
Air Temperature at Dryer Outlet (°C) 27,5 27,8 28,1
Compressor Absorbed Power (kW) 14,09 14,15 14,21
Condenser Heat Rejected (kW) 69,28 73,42 77,81
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Inlet Condenser Water Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Water Flow (m³/h) 4,28 4,61 4,98
Water Pressure Drop* (bar) 0,06 0,07 0,08
Condensing Temperature (°C) 40
Max / Min Inlet Condenser Water Temperature (°C) 48 / 10
Maximum Operating Pressure (bar g) 14
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 11,0
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 5
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN16 DN200
Water Connections Inlet / Outlet 1½” BSPT - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 1616
Depth (mm) 2257
Weight (kg) 1100
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 225
F.L.A. Current (Amps) 40
Total Installed Power (kW) 23,3
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*The total pressure drop, including the water regulator valve, is about 1,7÷2 bar Max / Min Ambient Temperature (°C): 50 / 5
*** With Integrated Drain Max / Min Air Inlet Temperature (°C): 65 / 5

www.CompAir.com www.GardnerDenver.com
Engineering Data
Rev 32 - 17/02/2011

Engineering Data GDD1800HSW - Water Cooled

PERFORMANCE DATA
Pressure Dew Point (°C) 3 5 7
Airflow Capacity (m³/h FAD 20°C) 10800 12016 13389
Air Pressure Drop (bar) 0,21 0,26 0,32
Air Temperature at Dryer Outlet (°C) 27,5 27,8 28,1
Compressor Absorbed Power (kW) 17,33 17,40 17,45
Condenser Heat Rejected (kW) 83,5 88,7 94,1
REFERENCE DATA
Working Pressure (bar g) 7
Inlet Air Temperature (°C) 35
Inlet Condenser Water Temperature (°C) 25
Relative Humidity (%) 100
GENERAL DATA
Water Flow (m³/h) 5,50 6,01 6,59
Water Pressure Drop* (bar) 0,10 0,12 0,14
Condensing Temperature (°C) 40
Max / Min Inlet Condenser Water Temperature (°C) 48 / 10
Maximum Operating Pressure (bar g) 14
Refrigerant Type R407C
Fridge Compressor Type / n° Hermetic Scroll / 1
Refrigerant Quantity (kg) 13,5
Capacity Control Cycling
Expansion System Capillary Tube
Air-to-air Heat Exchanger Aluminium plate fins
Air-to-refrigerant Heat Exchanger Aluminium plate fins
Number of Heat Exchangers 6
Separator Type Demister
Drain Type Integrated or Electronic
PIPING CONNECTIONS
Air Inlet / Outlet PN16 DN200
Water Connections Inlet / Outlet 1½” BSPT - F
Condensate Drain Inlet ½” BSP - F
Condensate Drain Outlet *** 3/8” BSP - F
DIMENSIONS + WEIGHT
Width (mm) 1007
Height (mm) 1616
Depth (mm) 2257
Weight (kg) 1190
ELECTRICAL DATA
Electrical Supply (+/- 10%) (AC) 400V / 3Ph / 50Hz
L.R.A. Current (Amps) 272
F.L.A. Current (Amps) 52
Total Installed Power (kW) 28,7
Control Type Microprocessor
Electrical Protection Class (Std.) IP44
PERFORMANCE IN ACCORDANCE WITH ISO 7183 Operating limits:
*The total pressure drop, including the water regulator valve, is about 1,7÷2 bar Max / Min Ambient Temperature (°C): 50 / 5