User: Canal WinFlume32 - Version 1.06.

0006
\\...\VERTEDEROS\1) Santa Delfina\SANTA DELFINA.Flm - Revision 13
SANTA DELFINA
Rating Equation Report, Printed: 12/10/2019 01:19:49 p. m.
Page 1

------------------------------------------------------------------------------
h1 Q Q_fit D=Q_fit-Q (D/Q)*100%
Sill Curve Fit
Referenced Theoretical Equation
Head at Gage Discharge Discharge Difference Difference
meters cu. m/s cu. m/s cu. m/s % Warnings
------------------------------------------------------------------------------
0.085 0.050 0.050 0.000 +0.53
0.130 0.100 0.099 -0.001 -0.74
0.166 0.150 0.149 -0.001 -0.55
0.196 0.200 0.200 0.000 -0.25
0.224 0.250 0.250 0.000 -0.01
0.249 0.300 0.301 +0.001 +0.18
0.272 0.350 0.351 +0.001 +0.28
0.293 0.400 0.401 +0.001 +0.34
0.313 0.450 0.452 +0.002 +0.36
0.332 0.500 0.502 +0.002 +0.34
0.351 0.550 0.552 +0.002 +0.31
0.368 0.600 0.602 +0.002 +0.25
0.385 0.650 0.651 +0.001 +0.17
0.401 0.700 0.701 +0.001 +0.08
0.416 0.750 0.750 0.000 -0.02
0.431 0.800 0.799 -0.001 -0.13
0.445 0.850 0.848 -0.002 -0.25
0.459 0.900 0.897 -0.003 -0.37
0.473 0.950 0.945 -0.005 -0.50

Equation: Q_fit = K1 * (h1 + K2) ^ u


Parameters: K1 = 3.59581
K2 = 0.018598
u = 1.88130
Coefficient of determination: 0.99998011
Theoretical discharge (Q) is determined by the WinFlume model, using
hydraulic theory and empirical relationships determined from laboratory
testing. It is the most accurate estimate of discharge. Curve fit discharge
(Q_fit) is computed with the equation above, which was fitted to the
theoretical discharge values. The 'difference' columns show the difference
between the flow rates computed from the simplified equation and those
obtained from the theoretical WinFlume model.

Summary of Warning Messages


---------------------------
No warnings.